1.
Stud Health Technol Inform ; 216: 98-102, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26262018

RESUMO

Smartphones include features that offers the chance to develop mobile systems in medical field, resulting in an area called mobile-health. One of the most common medical examinations is the electrocardiogram (ECG), which allows the diagnosis of various heart diseases, leading to preventative measures and preventing more serious problems. The objective of this study was to develop a wireless reconfigurable embedded system using a FPAA (Field Programmable Analog Array), for the acquisition of ECG signals, and an application showing and storing these signals on Android smartphones. The application also performs the partial FPAA reconfiguration in real time (adjustable gain). Previous studies using FPAA usually use the development boards provided by the manufacturer (high cost), do not allow the reconfiguration in real time, use no smartphone and communicate via cables. The parameters tested in the acquisition circuit and the quality of ECGs registered in an individual were satisfactory.


Assuntos
Amplificadores Eletrônicos , Diagnóstico por Computador/instrumentação , Eletrocardiografia Ambulatorial/instrumentação , Processamento de Sinais Assistido por Computador/instrumentação , Smartphone , Tecnologia sem Fio/instrumentação , Diagnóstico por Computador/métodos , Desenho de Equipamento , Análise de Falha de Equipamento , Aplicativos Móveis , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Interface Usuário-Computador
2.
Artigo em Inglês | MEDLINE | ID: mdl-21095763

RESUMO

Literatures in the health areas are reported frequently on accidents caused by problems with shock during surgery in both patients as the clinical team. It should be noted that most electrical equipment, during use, is often in contact with the patient and / or with medical professionals. Therefore, the electric shock danger always exists in this environment. To avoid this, some equipment has been identified for monitoring IT-system and the use of these normally required by standards. The research described in this paper presents an electrical safety and information system in a critical environment on the hospital that meets the standard. This system has an insulation monitoring device and annunciator, part of the IT-system, with unpublished characteristics.


Assuntos
Redes de Comunicação de Computadores/instrumentação , Traumatismos por Eletricidade/prevenção & controle , Eletricidade , Análise de Falha de Equipamento/instrumentação , Segurança de Equipamentos/instrumentação , Sistemas de Informação Hospitalar , Brasil , Humanos
3.
Rev. bras. eng. biomed ; 18(3): 151-162, set.-dez. 2002. ilus, tab
Artigo em Português | LILACS | ID: lil-358861

RESUMO

A incubadora neonatal é um equipamento médico-assistencial usado para a manutenção da vida de recém-nascidos prematuros. Sua função é proporcionar um ambiente termoneutro que é obtido através do controle da temperatura e da umidade relativa do ar em níveis adequados. Isto permite que o bebê mantenha a temperatura corporal normal a baixas taxas metabólicas. Este ambiente contibui para um desenvolvimento rápido e com uma menor incidência de doenças. No presente trabalho, descreve-se um aparelho eletrônico constuído para testar incubadoras, que verifica as características do ambiente por elas proporcionado ao recém-nascido. O protótipo desenvolvido mede, no interior da incubadora, a temperatura do ar em cinco pontos diferentes, a umidade relativa, o nível sonoro e verifica o estado da velocidade do fluxo de ar. O equipamento pode funcionar no modo de coleta, onde armazena as grandezas citadas a cada minuto, permitindo uma transferência posterior dos dados para um microcomputador PC, ou no modo de teste, onde realiza testes baseados na norma NBR IEC 601-2-19. Neste último, o aparelho instrui o operador através de mensagens no visor e avisos sonoros quando ajustes devem ser feitos nos controles da incubadora, ou quando algum problema é detectado. Os resultados de testes realizados no modo de coleta, em algumas incubadoras, são apresentados.


Assuntos
Análise de Falha de Equipamento/instrumentação , Análise de Falha de Equipamento/normas , Incubadoras para Lactentes , Segurança de Equipamentos/instrumentação , Fatores de Risco , Documentação