1.
J Radiat Res ; 64(1): 53-62, 2023 Jan 20.
Artigo em Inglês | MEDLINE | ID: mdl-36371757

RESUMO

This study assessed the potential radiological risks associated with the activities on Olusosun dump site on workers and dwellers of Olusosun community. The activity concentrations of 238U, 232Th and 40K from of soil and water samples were determined using High-Purity Germanium (HPGe) detector. The background radiation level of Olusosun dump site was measured using a portable Geiger-Müller counter-Radeye B20 survey meter. The mean value of background radiation was 1.46 mSv/yr. This value is about 46% higher than the recommended reference level of 1.0 mSv/yr for the public. The mean activity concentrations of 238U, 232Th and 40K in the soil samples were 19.1 ± 3.2, 29.1 ± 4.4 and 171.5 ± 6.1 Bq/kg respectively which are about 45.4%, 35.3% and 59.2% lower than the world's average levels. For the water samples, the mean activity concentrations obtained for 238U, 232Th and 40K are 0.4 ± 0.4, 0.8 ± 0.2 and 0.8 ± 0.3 Bq/l respectively. These are about 99.9% and 20% lower than WHO reference levels for 238U and 232Th. The mean absorbed dose rate in air (D), Annual effective dose (AED) outdoor, Radium Equivalent (Req), External hazard index (Hex) internal hazard index (Hin) and Excess lifetime cancer risk (ELCR) from soil samples were 33.6 nGy/h, 41.0 µSv/yr, 73.1 Bq/kg and 0.2, 0.3 and $1.4\times{10}^{-4}$, respectively. Absorbed dose in air D, AED outdoor, Req, Hex, Hin and ELCR are 41.1%, 41.4%, 80.3%, 80%, 75% and 50% lower than their corresponding world's average and references. The estimated AEDw from ingestion of water is 148.9 ± 50.4 µSv/yr, this is about 49% higher than the WHO reference level of 100.0 µSv/y from ingestion of water. The radiological hazard indices estimated from soil samples do not indicate any potential risks to the users. The elevated background radiation level of the dump site, and AEDw from ingestion of water, however, suggest that the activities on Olusosun dump site pose potential radiological risks on workers on the site and the public from consumption of water from Olusosun community.


Assuntos
Rádio (Elemento) , Urânio , Humanos , Tório/análise , Urânio/análise , Nigéria , Rádio (Elemento)/análise , Água , Solo
2.
Int J Hyperthermia ; 32(8): 923-930, 2016 12.
Artigo em Inglês | MEDLINE | ID: mdl-27431435

RESUMO

PURPOSE: To study the efficiency of a dual slot antenna with a floating metallic sleeve on the ablation of different ex vivo bovine tissues. MATERIALS AND METHODS: COMSOL Multiphysics® version 4.4 (Stockholm, Sweden), which is based on finite element methods (FEM), was used to design and simulate monopole and dual slot with sleeve antennas. Power, specific absorption rate (SAR), temperature and necrosis distributions in the selected tissues were determined using these antennas. Monopole and dual slot with sleeve antennas were designed, simulated, constructed and applied in this study based on a semi-rigid coaxial cable. Ex vivo experiments were performed on liver, lung, muscle and heart of bovine obtained from a public animal slaughter house. The microwave energy was delivered using a 2.45 GHz solid-state microwave generator at 40 W for 3, 5 and 10 min. Aspect ratio, ablation length and ablation diameter were also determined on ablated tissues and compared with simulated results. Student's t-test was used to compare the statistically significant difference between the performance of the two antennas. RESULTS: The dual slot antenna with sleeve produces localised microwave energy better than the monopole antenna in all ablated tissues using simulation and experimental validation methods. There were significant differences in ablation diameter and aspect ratio between the sleeve antenna and monopole antenna. Additionally, there were no significant differences between the simulation and experimental results. CONCLUSIONS: This study demonstrated that the dual slot antenna with sleeve produced larger ablation zones and higher sphericity index in ex vivo bovine tissues with minimal backward heating when compared with the monopole antenna.


Assuntos
Técnicas de Ablação/instrumentação , Micro-Ondas , Animais , Bovinos , Desenho de Equipamento , Coração , Fígado/cirurgia , Pulmão/cirurgia , Modelos Teóricos , Músculos/cirurgia