Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Heliyon ; 5(6): e01936, 2019 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-31294104

RESUMO

BACKGROUND: Vision plays a key role in some behavior tests for rats. Okayama University-type retinal prosthesis (OUReP) is a photoelectric dye-coupled polyethylene film which generates electric potential in response to light and stimulates nearby neurons. This study aims to assess vision in retinal dystrophic (RCS) rats, in comparison with normal rats, by selected behavior tests. We also examined whether the tests could detect vision changes in RCS rats with dye-coupled film implantation. METHODS: Data sets were 5 normal rats, 4 untreated RCS rats, 7 RCS rats with dye-coupled films implanted at the age of 7 weeks after excluding unsuccessful implantation at autopsy. Behavior tests chosen were landing foot splay and visual forelimb-placing response in the menu of functional observational battery, operant-conditioning lever-press response and light/dark box test. RESULTS: Normal visual placing response was significantly less frequent in untreated RCS rats at the age of 9 and 11 weeks, compared with normal rats (P = 0.0027, chi-square test) while normal response was significantly more frequent at the age of 9 weeks in RCS rats with dye-coupled film implantation, compared with untreated RCS rats (P = 0.0221). In operant-conditioning lever-press test, the correct response rate was significantly lower in untreated RCS rats than in normal rats at the age of 9 weeks (P < 0.05, Tukey-Kramer test) while the rate was not significantly different between normal rats and RCS rats with dye-coupled film implantation. In light/dark box test, the time to enter dark box was significantly shorter in normal rats, compared with untreated RCS rats or RCS rats with dye-coupled film implantation (P < 0.05, Tukey-Kramer test). CONCLUSIONS: Behavior tests of functional observational battery, operant-conditioning lever-press response and light/dark box test discriminated vision between normal rats and RCS rats. The visual placing response and operant-conditioning lever-press test might have sensitivity to detect vision recovery in RCS rats with OUReP implantation.

2.
J Vet Med Sci ; 80(2): 247-259, 2018 Feb 09.
Artigo em Inglês | MEDLINE | ID: mdl-29311491

RESUMO

Okayama University-type retinal prosthesis (OURePTM) is a photoelectric dye-coupled polyethylene film which generates electric potential in response to light and stimulates nearby neurons. This study aims to test surgical feasibility for subretinal film implantation and to examine functional durability of films in subretinal space. Dye-coupled films were implanted subretinally by vitrectomy in the right eye of normal white rabbits: 8 rabbits for 1 month and 8 rabbits for 6 months. The implanted films were removed by vitrectomy in 4 of these 8 rabbits in 1-month or 6-month implantation group. The films were also implanted in 4 rhodopsin-transgenic retinal dystrophic rabbits. Visual evoked potential was measured before film implantation as well as 1 or 6 months after film implantation, or 1 month after film removal. The films were successfully implanted in subretinal space of retinal detachment induced by subretinal fluid injection with a 38G polyimide tip. The retina was reattached by fluid-air exchange in vitreous cavity, retinal laser coagulation, and silicone oil injection. The ratios of P2 amplitudes of visual evoked potential in the implanted right eye over control left eye did not show significant changes between pre-implantation and post-implantation or post-removal (paired t-test). In Kelvin probe measurements, 4 pieces each of removed films which were implanted for 1 or 6 months showed proportional increase of surface electric potential in response to increasing light intensity. The film implantation was safe and implanted films were capable of responding to light.


Assuntos
Potenciais Evocados Visuais , Próteses Visuais , Animais , Potenciais Evocados Visuais/fisiologia , Masculino , Implantação de Prótese/métodos , Implantação de Prótese/veterinária , Coelhos , Próteses Visuais/veterinária , Vitrectomia/métodos , Vitrectomia/veterinária
3.
J Vet Med Sci ; 79(12): 1939-1946, 2017 Dec 06.
Artigo em Inglês | MEDLINE | ID: mdl-29046507

RESUMO

Okayama University-type retinal prosthesis (OURePTM) is a photoelectric dye-coupled polyethylene film which generates electric potential in response to light and stimulates nearby neurons. This study aims to test surgical feasibility of subretinal implantation and functional durability of dye-coupled films in the subretinal space. The dye-coupled films were implanted subretinally by 25-gauge vitrectomy in the right eye of 11 normal beagle dogs: 2 dogs served for film removal after 5-month film implantation, 3 dogs for film removal after 3-month film implantation, 3 dogs for 3-month film implantation and pathological examination, and 3 dogs for sham surgery. The surface electric potential of the removed dye-coupled films in response to light was measured by the Kelvin Probe system. At surgery, rolled-up dye-coupled films in 5 × 5 mm square size could be inserted into subretinal space of retinal detachment induced by fluid injection with a 38-gauge polyimide tip. Retinal attachment was maintained by silicone oil injection in vitreous cavity. At autopsy, the retina in all dogs maintained the ganglion cell layer, inner and outer nuclear layers while it lost the outer segments in some part. All 5 sheets of removed dye-coupled films maintained the dye color. One sheet of the 5-month implanted film showed proportional increase of surface potential in response to increasing light intensity. Subretinal implantation of OURePTM by vitrectomy was technically feasible in canine eyes, and OURePTM maintained the function of generating light-evoked surface potential after 5 months in subretinal implantation.


Assuntos
Implantação de Prótese/veterinária , Próteses Visuais/veterinária , Corpo Vítreo/cirurgia , Animais , Corantes/química , Cães , Potenciais Evocados Visuais , Estudos de Viabilidade , Masculino , Polietileno , Retina/patologia , Óleos de Silicone , Vitrectomia/veterinária , Corpo Vítreo/patologia , Corpo Vítreo/fisiopatologia
4.
Nature ; 538(7625): 388-391, 2016 Oct 20.
Artigo em Inglês | MEDLINE | ID: mdl-27723741

RESUMO

Induced pluripotent stem cells (iPSCs) constitute a potential source of autologous patient-specific cardiomyocytes for cardiac repair, providing a major benefit over other sources of cells in terms of immune rejection. However, autologous transplantation has substantial challenges related to manufacturing and regulation. Although major histocompatibility complex (MHC)-matched allogeneic transplantation is a promising alternative strategy, few immunological studies have been carried out with iPSCs. Here we describe an allogeneic transplantation model established using the cynomolgus monkey (Macaca fascicularis), the MHC structure of which is identical to that of humans. Fibroblast-derived iPSCs were generated from a MHC haplotype (HT4) homozygous animal and subsequently differentiated into cardiomyocytes (iPSC-CMs). Five HT4 heterozygous monkeys were subjected to myocardial infarction followed by direct intra-myocardial injection of iPSC-CMs. The grafted cardiomyocytes survived for 12 weeks with no evidence of immune rejection in monkeys treated with clinically relevant doses of methylprednisolone and tacrolimus, and showed electrical coupling with host cardiomyocytes as assessed by use of the fluorescent calcium indicator G-CaMP7.09. Additionally, transplantation of the iPSC-CMs improved cardiac contractile function at 4 and 12 weeks after transplantation; however, the incidence of ventricular tachycardia was transiently, but significantly, increased when compared to vehicle-treated controls. Collectively, our data demonstrate that allogeneic iPSC-CM transplantation is sufficient to regenerate the infarcted non-human primate heart; however, further research to control post-transplant arrhythmias is necessary.


Assuntos
Coração/fisiologia , Células-Tronco Pluripotentes Induzidas/citologia , Infarto do Miocárdio/terapia , Miócitos Cardíacos/citologia , Miócitos Cardíacos/transplante , Regeneração/fisiologia , Animais , Diferenciação Celular , Sobrevivência Celular , Feminino , Fibroblastos/citologia , Sobrevivência de Enxerto , Haplótipos , Imunossupressores , Macaca fascicularis , Complexo Principal de Histocompatibilidade/genética , Masculino , Contração Miocárdica/fisiologia , Infarto do Miocárdio/patologia , Infarto do Miocárdio/fisiopatologia , Miócitos Cardíacos/imunologia , Miócitos Cardíacos/metabolismo , Taquicardia Ventricular/etiologia , Taquicardia Ventricular/fisiopatologia , Fatores de Tempo , Transplante Homólogo
5.
Immunogenetics ; 67(10): 563-78, 2015 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-26349955

RESUMO

Although the low polymorphism of the major histocompatibility complex (MHC) transplantation genes in the Filipino cynomolgus macaque (Macaca fascicularis) is expected to have important implications in the selection and breeding of animals for medical research, detailed polymorphism information is still lacking for many of the duplicated class I genes. To better elucidate the degree and types of MHC polymorphisms and haplotypes in the Filipino macaque population, we genotyped 127 unrelated animals by the Sanger sequencing method and high-resolution pyrosequencing and identified 112 different alleles, 28 at cynomolgus macaque MHC (Mafa)-A, 54 at Mafa-B, 12 at Mafa-I, 11 at Mafa-E, and seven at Mafa-F alleles, of which 56 were newly described. Of them, the newly discovered Mafa-A8*01:01 lineage allele had low nucleotide similarities (<86%) with primate MHC class I genes, and it was also conserved in the Vietnamese and Indonesian populations. In addition, haplotype estimations revealed 17 Mafa-A, 23 Mafa-B, and 12 Mafa-E haplotypes integrated with 84 Mafa-class I haplotypes and Mafa-F alleles. Of these, the two Mafa-class I haplotypes, F/A/E/B-Hp1 and F/A/E/B-Hp2, had the highest haplotype frequencies at 10.6 and 10.2%, respectively. This suggests that large scale genetic screening of the Filipino macaque population would identify these and other high-frequency Mafa-class I haplotypes that could be used as MHC control animals for the benefit of biomedical research.


Assuntos
Alelos , Haplótipos , Antígenos de Histocompatibilidade Classe I/genética , Macaca fascicularis/genética , Análise de Sequência de DNA/métodos , Animais , Frequência do Gene , Genótipo , Antígenos de Histocompatibilidade Classe I/classificação , Filipinas , Filogenia , Polimorfismo Genético
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...