1.
Environ Technol ; 40(11): 1476-1484, 2019 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-29300678

RESUMO

Currently, an extractive green palm oil-based emulsion liquid membrane (ELM) has been used for simultaneous extraction and enrichment of Reactive Red 3BS from simulated synthetic dye wastewater. The ELM consists of two main phases, which are organic liquid membrane (LM) and stripping solution. During the extraction process, the ELM was dispersed into the simulated synthetic dye wastewater containing the Reactive Red 3BS complexes. The organic LM contains tridodecylamine (TDA), Sorbitan Monooleate (Span 80) and palm oil as a carrier, surfactant and diluent, respectively. The sodium bicarbonate (NaHCO3) was used as stripping solution for the enrichment process. Several important parameters that affected the simultaneous extraction and enrichment of Reactive Red 3BS, such as carrier and stripping agent concentrations, extraction time and treat ratio, were investigated. The results showed that almost 90% of Reactive Red 3BS ions were successfully extracted with 10 times enrichment in the stripping phase at the optimum conditions of 0.2 M TDA, 0.1 M NaHCO3, 5 min of extraction time and 1:5 of treat ratio. Hence, it can be concluded that palm oil possesses a high potential as green diluent in future technology, especially in ELM process for the removal and recovery of Reactive Red 3BS from synthetic dye wastewater.


Assuntos
Membranas Artificiais , Águas Residuárias , Emulsões , Íons , Tensoativos
2.
Sensors (Basel) ; 10(10): 9512-28, 2010.
Artigo em Inglês | MEDLINE | ID: mdl-22163423

RESUMO

This research investigates the use of charge coupled device (abbreviated as CCD) linear image sensors in an optical tomographic instrumentation system used for sizing particles. The measurement system, consisting of four CCD linear image sensors are configured around an octagonal shaped flow pipe for a four projections system is explained. The four linear image sensors provide 2,048 pixel imaging with a pixel size of 14 micron × 14 micron, hence constituting a high-resolution system. Image reconstruction for a four-projection optical tomography system is also discussed, where a simple optical model is used to relate attenuation due to variations in optical density, [R], within the measurement section. Expressed in matrix form this represents the forward problem in tomography [S] [R] = [M]. In practice, measurements [M] are used to estimate the optical density distribution by solving the inverse problem [R] = [S](-1)[M]. Direct inversion of the sensitivity matrix, [S], is not possible and two approximations are considered and compared-the transpose and the pseudo inverse sensitivity matrices.


Assuntos
Interpretação de Imagem Assistida por Computador/instrumentação , Interpretação de Imagem Assistida por Computador/métodos , Processamento de Imagem Assistida por Computador/instrumentação , Processamento de Imagem Assistida por Computador/métodos , Tamanho da Partícula , Tomografia Óptica/instrumentação , Tomografia Óptica/métodos , Algoritmos