Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Clin Nephrol ; 63(4): 276-83, 2005 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-15847254

RESUMO

AIMS: Hypotensive episodes are a major complication of hemodialysis. Hypotension during dialysis could be directly related to a reduction in blood volume or to a decrease in cardiovascular activation as a response to decreased cardiac filling. A decreased cardiovascular activation could be due to patient-related or to dialysis-related factors. In order to study the isolated effect of a reduction in filling pressure, lower body negative pressure (LBNP) causes activation of the cardiovascular reactivity with a decrease in cardiac filling, but without the influence of the dialysis procedure that could affect cardiovascular reactivity. METHODS: We studied the relationship between relative blood volume (RBV), central venous pressure (CVP), systolic arterial pressure, heart rate, stroke volume index (SI), and total peripheral resistance index (TPRI) during a combined dialysis/ultrafiltration and during LBNP to -40 mmHg in 21 hemodialysis patients with a high incidence of hypotension. Systolic arterial pressure, heart rate, SI and TPRI were measured by Finapres. CVP was measured after cannulation of the jugular vein. During dialysis RBV was measured by a blood volume monitor (BVM). In order to study the conditions in which hypotension occurred after dialysis, we divided the patients into 2 groups: hypotensive (H) and non-hypotensive (NH) during dialysis. RESULTS: Baseline levels did not show any significant differences. During dialysis systolic arterial pressure declined gradually in the H group from 30 minutes before the onset of hypotension. There was a similar decrease of RBV and increase of heart rate in both groups with a large interindividual variation. At hypotension, H patients showed a significantly smaller increase in TPRI as compared to NH patients. The reduction in SI tended to be greater at hypotension, while CVP decreased to a similar extent in both groups. Moreover, during LBNP, a similar reduction in CVP resulted in a much smaller decrease in SI. Systolic arterial pressure was only slightly lowered due to a much greater increase in TPRI. CONCLUSION: We conclude that dialysis-related hypotension in our patient group did not result from an inability to maintain blood volume or from decreased cardiac filling. Hypotension appeared to result from the inability to adequately increase arteriolar tone and a reduction in left ventricular function. Both vascular tone and left ventricular function appeared to be impaired by the dialysis procedure.


Assuntos
Hipotensão/etiologia , Músculo Liso Vascular/fisiopatologia , Diálise Renal/efeitos adversos , Resistência Vascular/fisiologia , Disfunção Ventricular Esquerda/fisiopatologia , Arteríolas/fisiopatologia , Pressão Sanguínea/fisiologia , Volume Sanguíneo/fisiologia , Pressão Venosa Central/fisiologia , Feminino , Seguimentos , Humanos , Hipotensão/epidemiologia , Hipotensão/fisiopatologia , Incidência , Pressão Negativa da Região Corporal Inferior , Masculino , Pessoa de Meia-Idade , Fatores de Risco , Volume Sistólico/fisiologia , Disfunção Ventricular Esquerda/complicações
2.
J Hum Hypertens ; 19(6): 439-44, 2005 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-15660121

RESUMO

An elevated pulse pressure leads to an increased pulsatile cardiac load, and results from arterial stiffening. The aim of our study was to test whether a reduction in volume overload by ultrafiltration (UF) during haemodialysis (HD) leads to an improvement of aortic compliance. In 18 patients, aortic compliance was estimated noninvasively before and after HD with UF using a pulse pressure method based on the Windkessel model. This technique has not been applied before in a dialysis population, and combines carotid pulse contour analysis by applanation tonometry with aortic outflow measurements by Doppler echocardiography. The median UF volume was 2450 ml (range 1000-4000 ml). The aortic outflow volume after HD (39 ml; 32-53 ml) was lower (P=0.01) than before (46 ml; 29-60 ml). Carotid pulse pressure after HD (42 mmHg; 25-85 mmHg) was lower (P=0.01) than before (46 mmHg; 35-93 mmHg). Carotid augmentation index after HD (22%; 3-30%) was lower (P=0.001) than before (31%; 7-53%). Carotid-femoral pulse wave velocity was not different after HD (8.7 m/s; 5.6-28.9 m/s vs 7.7 m/s; 4.7-36.8 m/s). Aortic compliance after HD (1.10 ml/mmHg; 0.60-2.43 ml/mmHg) was higher (P=0.02) than before (1.05 ml/mmHg; 0.45-1.69 ml/mmHg). The increase in aortic stiffness in HD patients is partly caused by a reversible reduction of aortic compliance due to volume expansion. Volume withdrawal by HD moves the arterial wall characteristics back to a more favourable position on the nonlinear pressure-volume curve, reflected in a concomitant decrease in arterial pressure and improved aortic compliance.


Assuntos
Aorta/fisiopatologia , Hemodiafiltração , Falência Renal Crônica/fisiopatologia , Falência Renal Crônica/terapia , Diálise Renal , Adulto , Idoso , Idoso de 80 Anos ou mais , Pressão Sanguínea , Artérias Carótidas/fisiopatologia , Complacência (Medida de Distensibilidade) , Ecocardiografia Doppler , Humanos , Falência Renal Crônica/diagnóstico por imagem , Pessoa de Meia-Idade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...