Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 12 de 12
Filtrar
1.
Transl Med UniSa ; 17: 19-21, 2017 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-30050876

RESUMO

Elevated left atrial (LA) pressures are associated with poor prognosis in heart failure (HF). Invasive monitoring of LA-pressures and direct mechanical LA-decompression are associated with functional improvement in patients suffering from HF both with reduced and preserved ejection fraction. We aim to review the current available percutaneously implantable sensors for haemodynamic telemonitoring of LA-pressures (direct LAP sensor device-HeartPOD; right ventricular device-Chronicle; pulmonary artery device-CardioMEMs).

2.
Minerva Chir ; 62(4): 305-7, 2007 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-17641590

RESUMO

Acute aortic dissection (AAD) is an uncommon lethal cardiovascular emergency demanding prompt diagnosis and aggressive therapeutic intervention. Although it usually affects males over 60 years of age, it may also occur in young adults with specific risk factors such as Marfan syndrome, bicuspid aortic valve and larger aortic dimensions. Moreover, it should be underlined that it is frequently associated with unusual presentation and that the mortality risk is similar to older AAD patients. Thus ''a call to arms'' of the medical community is needed to better understand the spectrum of acute aortic syndromes and to define appropriate diagnostic and therapeutic pathways. We report a series of 6 young patients with type A - AAD referred over the past years at our institute.


Assuntos
Aneurisma da Aorta Torácica/cirurgia , Dissecção Aórtica/cirurgia , Doença Aguda , Adulto , Dissecção Aórtica/mortalidade , Aneurisma da Aorta Torácica/mortalidade , Seguimentos , Humanos , Masculino , Estudos Retrospectivos , Fatores de Risco , Análise de Sobrevida , Resultado do Tratamento , Procedimentos Cirúrgicos Vasculares/métodos
3.
G Ital Cardiol ; 29(10): 1137-41, 1999 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-10546123

RESUMO

The accuracy of transesophageal echocardiography in the diagnosis and surgical management of acute aortic dissection was determined in 54 patients who underwent surgery for acute aortic dissection. Results of the investigations were compared to the surgical assessment. From April 1993 to November 1997, we operated 54 patients (44 male and 10 female) for acute aortic dissection. Mean age was 60 +/- 9 years. At surgery, a De Bakey type I aortic dissection was diagnosed in 30 patients, type II in 23 and type III retrograde in 1. Operating procedures were: replacement of ascending aorta (24 cases), replacement of ascending aorta and aortic arch (17 cases), replacement of ascending aorta and aortic valve replacement (2 cases), Bentall procedure (6 cases) and end-to-end anastomosis of the ascending aorta (4 cases). Initial diagnosis, performed in emergency wards, was done on a clinical basis in 6 patients, on CT scan in 19, on transthoracic echocardiography in 14, and on TEE basis in 12. Three patients underwent angiography before our evaluation. As per our protocol, all patients underwent confirmation of the diagnosis by TEE. Seven patients needed additional instrumental investigations, 2 with CT scan and 5 with angiography. TEE confirmed the diagnosis of aortic dissection in all cases but one. Moreover, it described the site of the intimal tear, the extension of the dissecting process and accessory findings, such as pericardial effusion, aortic incompetence and left ventricular function. The interval between patient presentation and skin incision was a maximum of 70 minutes. At surgery, diagnosis of De Bakey classification was confirmed in 98% of cases; in 90.7% of cases exact location of the entry site was confirmed. In one case, an entry site in the arch diagnosed by TEE but not recognized at surgery, was observed at necropsy. Intraoperatively, we routinely used TEE to monitor retrograde systemic perfusion and correct implant of the vascular prosthesis. One case of malperfusion of the thoracic aorta through the false lumen was observed and managed. In one case we diagnosed acute obstruction of the prosthesis by bleeding in the wrapped aorta, which required reoperation. Assessment of ventricular function was obtained in all patients: in two cases, observation of low right ventricular function led us to perform aortocoronary by-pass to the right coronary artery. In conclusion, the high level of correspondence between TEE diagnosis and surgical anatomy prompted us to perform transesophageal echocardiography as the primary and often sole diagnostic procedure in acute aortic dissection. TEE, in experienced hands, has proven to be a highly reliable, safe and low-cost diagnostic tool. It can be performed at the patient's bedside within just a few minutes of the suspected diagnosis, thereby lowering the mortality rate of the natural history. Again, it can also be used in the operating theatre as an "on-line examination" as well as for assessment of correct surgical repair. Other diagnostic procedures do not yield more information and can cause dangerous delays in intervention.


Assuntos
Aneurisma Aórtico/cirurgia , Dissecção Aórtica/cirurgia , Ecocardiografia Transesofagiana , Adulto , Idoso , Idoso de 80 Anos ou mais , Dissecção Aórtica/diagnóstico por imagem , Aneurisma Aórtico/diagnóstico por imagem , Aneurisma da Aorta Torácica/diagnóstico por imagem , Aneurisma da Aorta Torácica/cirurgia , Valva Aórtica/cirurgia , Feminino , Implante de Prótese de Valva Cardíaca , Humanos , Masculino , Pessoa de Meia-Idade
4.
Tex Heart Inst J ; 25(4): 303-5, 1998.
Artigo em Inglês | MEDLINE | ID: mdl-9885108

RESUMO

We report the case of a 74-year-old woman who underwent an elective procedure to replace her mitral valve with a 27-mm CarboMedics bileaflet valve (CarboMedics, Inc.; Austin, Tex) to correct mitral incompetence. Massive thrombosis of the prosthesis was clinically evident on the 6th postoperative day, despite administration of warfarin therapy according to our usual protocol. After an unsuccessful attempt at thrombolysis with recombinant tissue plasminogen activator, the mechanical prosthesis was replaced with a bioprosthesis. The cause of the thrombosis is unknown, but transient suboptimal anticoagulation is assumed to be responsible. Although very early massive valve thrombosis is a rare occurrence, it is a known risk of prosthetic valve implantation. Antiplatelet therapy, in addition to the usual warfarin anticoagulation, can help to prevent it. If thrombosis is diagnosed, it can be managed by thrombolysis or, when thrombolysis is unsuccessful, by reoperation. Transesophageal echocardiography is fundamental in the diagnosis and management of this sequela.


Assuntos
Trombose Coronária/etiologia , Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Mitral/cirurgia , Complicações Pós-Operatórias , Idoso , Anticoagulantes/uso terapêutico , Bioprótese , Feminino , Humanos , Reoperação , Varfarina/uso terapêutico
6.
J Heart Valve Dis ; 5(1): 114-6, 1996 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-8834734

RESUMO

We report four cases of one leaflet immobilization which occurred early after mitral valve replacement with a Carbomedics bileaflet valve. The first case was diagnosed incidentally six days after surgery and did not require reoperation because of the spontaneous normalization of the valve movements the day before the scheduled reoperation. Since then, we have been using intraoperative transesophageal echocardiography in mitral procedures routinely (both valve repair or replacement). We were able to detect malfunctions which required reorientation in three other prostheses. We emphasize the importance of performing intraoperative transesophageal echocardiography routinely in these procedures; its high sensitivity and low risk can help to avoid a late reoperation.


Assuntos
Próteses Valvulares Cardíacas , Insuficiência da Valva Mitral/cirurgia , Estenose da Valva Mitral/cirurgia , Complicações Pós-Operatórias/cirurgia , Cardiopatia Reumática/cirurgia , Ecocardiografia Doppler , Ecocardiografia Transesofagiana , Feminino , Seguimentos , Humanos , Pessoa de Meia-Idade , Insuficiência da Valva Mitral/diagnóstico por imagem , Estenose da Valva Mitral/diagnóstico por imagem , Complicações Pós-Operatórias/diagnóstico por imagem , Desenho de Prótese , Falha de Prótese , Reoperação , Cardiopatia Reumática/diagnóstico por imagem
7.
Thorac Cardiovasc Surg ; 43(1): 40-3, 1995 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-7540327

RESUMO

Isolated coronary ostial stenosis is an unusual condition, most often atherosclerotic in origin. Only few cases have been reported as idiopathic. The clinical profile of the latter patients suggests that this group may represent a distinct clinical entity, with peculiar diagnostic and therapeutic features. We present our experience concerning six patients with isolated idiopathic coronary ostial stenosis, who successfully underwent transaortic left main ostioplasty with autologous pericardial patch fixed in glutaraldehyde. A review of previous reports in regard to the surgical management of coronary ostial disease is presented.


Assuntos
Doença das Coronárias/cirurgia , Adulto , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade
8.
Tex Heart Inst J ; 21(4): 314-6, 1994.
Artigo em Inglês | MEDLINE | ID: mdl-7888809

RESUMO

A 70-year-old woman underwent an aortocoronary bypass. Three hours later, she experienced severe pulmonary embolism, diagnosed by transesophageal echocardiography and followed by cardiac arrest. Resuscitation maneuvers were unsuccessful. Autopsy confirmed the diagnosis. When pulmonary embolism occurs after cardiopulmonary bypass for cardiac surgery, it usually occurs in the 2nd postoperative week; and to the best of our knowledge, the literature contains no other reports of cases that occurred during a shorter postoperative interval. Prevention of pulmonary embolism in high-risk patients is mandatory. When embolism occurs, transesophageal echocardiography is an essential tool in making the diagnosis and in guiding the surgeon during intervention.


Assuntos
Ponte Cardiopulmonar , Complicações Pós-Operatórias , Embolia Pulmonar/etiologia , Idoso , Evolução Fatal , Feminino , Humanos , Fatores de Tempo
12.
Int J Cardiol ; 9(4): 399-412, 1985 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-4077299

RESUMO

A clinico-pathologic study was performed in 25 patients undergoing aortic valve replacement because of regurgitation, caused by myxoid degeneration of the valve leaflets. Associated cardiac anomalies were floppy mitral valve (2 cases), floppy mitral valve and idiopathic hypertrophic subaortic stenosis (1), left atrial myxoma (1), and aortic coarctation at the isthmus (1). Three patients died (2 immediately and 1 on the 30th postoperative day). Pathological studies of the explanted valves showed deformities characterized by redundant thin leaflets which appeared soft and gelatinous. On histologic examination the fibrous layer of the leaflets was seen to be infiltrated by myxomatous tissue. Echocardiography showed the aortic root to be dilated in 13 patients and normal in the others. In those with normal aortic root, the histological examination of aortic wall disclosed minimal cystic medial necrosis in two cases. In contrast, more severe forms of cystic medial necrosis were evident in all patients having a dilated aortic root. Aortic valve replacement was performed in all cases. It was accompanied by a Bentall procedure (1 case), repair of ascending aorta dissection (2), replacement of the ascending aorta (1), mitral valve replacement (2), mitral valve replacement and apico-ascending aorta conduit (1) and excision of a left atrial myxoma (1). Our experience suggests that prolapse of the aortic valve due to floppy leaflets is a common degenerative disease which is generally associated with noninflammatory aortic root degeneration. This, together with aortic root dilatation, contributes to valve insufficiency. Nevertheless, the disease, when isolated (with normal aortic root), is liable in itself to produce aortic regurgitation. The need for early diagnosis is stressed, so as to be able to perform valve replacement.


Assuntos
Insuficiência da Valva Aórtica/etiologia , Valva Aórtica , Adulto , Valva Aórtica/cirurgia , Insuficiência da Valva Aórtica/patologia , Estenose da Valva Aórtica/etiologia , Feminino , Doenças das Valvas Cardíacas/complicações , Doenças das Valvas Cardíacas/patologia , Próteses Valvulares Cardíacas , Humanos , Masculino
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...