Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
JMIR Mhealth Uhealth ; 9(4): e27336, 2021 04 09.
Artigo em Inglês | MEDLINE | ID: mdl-33835040

RESUMO

BACKGROUND: Vertical jump height is widely used in health care and sports fields to assess muscle strength and power from lower limb muscle groups. Different approaches have been proposed for vertical jump height measurement. Some commonly used approaches need no sensor at all; however, these methods tend to overestimate the height reached by the subjects. There are also novel systems using different kind of sensors like force-sensitive resistors, capacitive sensors, and inertial measurement units, among others, to achieve more accurate measurements. OBJECTIVE: The objective of this study is twofold. The first objective is to validate the functioning of a developed low-cost system able to measure vertical jump height. The second objective is to assess the effects on obtained measurements when the sampling frequency of the system is modified. METHODS: The system developed in this study consists of a matrix of force-sensitive resistor sensors embedded in a mat with electronics that allow a full scan of the mat. This mat detects pressure exerted on it. The system calculates the jump height by using the flight-time formula, and the result is sent through Bluetooth to any mobile device or PC. Two different experiments were performed. In the first experiment, a total of 38 volunteers participated with the objective of validating the performance of the system against a high-speed camera used as reference (120 fps). In the second experiment, a total of 15 volunteers participated. Raw data were obtained in order to assess the effects of different sampling frequencies on the performance of the system with the same reference device. Different sampling frequencies were obtained by performing offline downsampling of the raw data. In both experiments, countermovement jump and countermovement jump with arm swing techniques were performed. RESULTS: In the first experiment an overall mean relative error (MRE) of 1.98% and a mean absolute error of 0.38 cm were obtained. Bland-Altman and correlation analyses were performed, obtaining a coefficient of determination equal to R2=.996. In the second experiment, sampling frequencies of 200 Hz, 100 Hz, and 66.6 Hz show similar performance with MRE below 3%. Slower sampling frequencies show an exponential increase in MRE. On both experiments, when dividing jump trials in different heights reached, a decrease in MRE with higher height trials suggests that the precision of the proposed system increases as height reached increases. CONCLUSIONS: In the first experiment, we concluded that results between the proposed system and the reference are systematically the same. In the second experiment, the relevance of a sufficiently high sampling frequency is emphasized, especially for jump trials whose height is below 10 cm. For trials with heights above 30 cm, MRE decreases in general for all sampling frequencies, suggesting that at higher heights reached, the impact of high sampling frequencies is lesser.


Assuntos
Teste de Esforço , Esportes , Humanos , Extremidade Inferior , Força Muscular , Reprodutibilidade dos Testes
2.
Sensors (Basel) ; 20(18)2020 Sep 22.
Artigo em Inglês | MEDLINE | ID: mdl-32972028

RESUMO

Respiratory monitoring is essential in sleep studies, sport training, patient monitoring, or health at work, among other applications. This paper presents a comprehensive systematic review of respiration sensing systems. After several systematic searches in scientific repositories, the 198 most relevant papers in this field were analyzed in detail. Different items were examined: sensing technique and sensor, respiration parameter, sensor location and size, general system setup, communication protocol, processing station, energy autonomy and power consumption, sensor validation, processing algorithm, performance evaluation, and analysis software. As a result, several trends and the remaining research challenges of respiration sensors were identified. Long-term evaluations and usability tests should be performed. Researchers designed custom experiments to validate the sensing systems, making it difficult to compare results. Therefore, another challenge is to have a common validation framework to fairly compare sensor performance. The implementation of energy-saving strategies, the incorporation of energy harvesting techniques, the calculation of volume parameters of breathing, or the effective integration of respiration sensors into clothing are other remaining research efforts. Addressing these and other challenges outlined in the paper is a required step to obtain a feasible, robust, affordable, and unobtrusive respiration sensing system.


Assuntos
Algoritmos , Monitorização Fisiológica , Respiração , Humanos , Software
3.
Med Biol Eng Comput ; 55(10): 1849-1858, 2017 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-28251444

RESUMO

Research on body-worn sensors has shown how they can be used for the detection of falls in the elderly, which is a relevant health problem. However, most systems are trained with simulated falls, which differ from those of the target population. In this paper, we tackle the problem of fall detection using a combination of novelty detectors. A novelty detector can be trained only with activities of daily life (ADL), which are true movements recorded in real life. In addition, they allow adapting the system to new users, by recording new movements and retraining the system. The combination of several detectors and features enhances performance. The proposed approach has been compared with a traditional supervised algorithm, a support vector machine, which is trained with both falls and ADL. The combination of novelty detectors shows better performance in a typical cross-validation test and in an experiment that mimics the effect of personalizing the classifiers. The results indicate that it is possible to build a reliable fall detector based only on ADL.


Assuntos
Acelerometria/métodos , Acidentes por Quedas/prevenção & controle , Aceleração , Atividades Cotidianas , Idoso , Algoritmos , Humanos , Monitorização Ambulatorial/métodos , Movimento/fisiologia , Máquina de Vetores de Suporte
4.
Sensors (Basel) ; 16(1)2016 Jan 18.
Artigo em Inglês | MEDLINE | ID: mdl-26797614

RESUMO

The risk of falling is high among different groups of people, such as older people, individuals with Parkinson's disease or patients in neuro-rehabilitation units. Developing robust fall detectors is important for acting promptly in case of a fall. Therefore, in this study we propose to personalize smartphone-based detectors to boost their performance as compared to a non-personalized system. Four algorithms were investigated using a public dataset: three novelty detection algorithms--Nearest Neighbor (NN), Local Outlier Factor (LOF) and One-Class Support Vector Machine (OneClass-SVM)--and a traditional supervised algorithm, Support Vector Machine (SVM). The effect of personalization was studied for each subject by considering two different training conditions: data coming only from that subject or data coming from the remaining subjects. The area under the receiver operating characteristic curve (AUC) was selected as the primary figure of merit. The results show that there is a general trend towards the increase in performance by personalizing the detector, but the effect depends on the individual being considered. A personalized NN can reach the performance of a non-personalized SVM (average AUC of 0.9861 and 0.9795, respectively), which is remarkable since NN only uses activities of daily living for training.


Assuntos
Acelerometria/instrumentação , Acidentes por Quedas/prevenção & controle , Atividades Cotidianas/classificação , Medicina de Precisão/instrumentação , Smartphone , Adulto , Algoritmos , Humanos , Medicina de Precisão/métodos , Adulto Jovem
5.
Med Eng Phys ; 37(9): 870-8, 2015 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-26233258

RESUMO

Falls are one of the leading causes of mortality among the older population, being the rapid detection of a fall a key factor to mitigate its main adverse health consequences. In this context, several authors have conducted studies on acceleration-based fall detection using external accelerometers or smartphones. The published detection rates are diverse, sometimes close to a perfect detector. This divergence may be explained by the difficulties in comparing different fall detection studies in a fair play since each study uses its own dataset obtained under different conditions. In this regard, several datasets have been made publicly available recently. This paper presents a comparison, to the best of our knowledge for the first time, of these public fall detection datasets in order to determine whether they have an influence on the declared performances. Using two different detection algorithms, the study shows that the performances of the fall detection techniques are affected, to a greater or lesser extent, by the specific datasets used to validate them. We have also found large differences in the generalization capability of a fall detector depending on the dataset used for training. In fact, the performance decreases dramatically when the algorithms are tested on a dataset different from the one used for training. Other characteristics of the datasets like the number of training samples also have an influence on the performance while algorithms seem less sensitive to the sampling frequency or the acceleration range.


Assuntos
Acelerometria/métodos , Acidentes por Quedas , Algoritmos , Conjuntos de Dados como Assunto , Acidentes por Quedas/estatística & dados numéricos , Adulto , Feminino , Humanos , Modelos Lineares , Masculino , Pessoa de Meia-Idade , Máquina de Vetores de Suporte , Adulto Jovem
6.
PLoS One ; 9(4): e94811, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-24736626

RESUMO

Despite being a major public health problem, falls in the elderly cannot be detected efficiently yet. Many studies have used acceleration as the main input to discriminate between falls and activities of daily living (ADL). In recent years, there has been an increasing interest in using smartphones for fall detection. The most promising results have been obtained by supervised Machine Learning algorithms. However, a drawback of these approaches is that they rely on falls simulated by young or mature people, which might not represent every possible fall situation and might be different from older people's falls. Thus, we propose to tackle the problem of fall detection by applying a kind of novelty detection methods which rely only on true ADL. In this way, a fall is any abnormal movement with respect to ADL. A system based on these methods could easily adapt itself to new situations since new ADL could be recorded continuously and the system could be re-trained on the fly. The goal of this work is to explore the use of such novelty detectors by selecting one of them and by comparing it with a state-of-the-art traditional supervised method under different conditions. The data sets we have collected were recorded with smartphones. Ten volunteers simulated eight type of falls, whereas ADL were recorded while they carried the phone in their real life. Even though we have not collected data from the elderly, the data sets were suitable to check the adaptability of novelty detectors. They have been made publicly available to improve the reproducibility of our results. We have studied several novelty detection methods, selecting the nearest neighbour-based technique (NN) as the most suitable. Then, we have compared NN with the Support Vector Machine (SVM). In most situations a generic SVM outperformed an adapted NN.


Assuntos
Aceleração , Acidentes por Quedas , Telefone Celular , Monitorização Ambulatorial/métodos , Atividades Cotidianas , Adulto , Algoritmos , Feminino , Humanos , Masculino , Máquina de Vetores de Suporte , Adulto Jovem
7.
Biomed Eng Online ; 12: 66, 2013 Jul 06.
Artigo em Inglês | MEDLINE | ID: mdl-23829390

RESUMO

Since falls are a major public health problem among older people, the number of systems aimed at detecting them has increased dramatically over recent years. This work presents an extensive literature review of fall detection systems, including comparisons among various kinds of studies. It aims to serve as a reference for both clinicians and biomedical engineers planning or conducting field investigations. Challenges, issues and trends in fall detection have been identified after the reviewing work. The number of studies using context-aware techniques is still increasing but there is a new trend towards the integration of fall detection into smartphones as well as the use of machine learning methods in the detection algorithm. We have also identified challenges regarding performance under real-life conditions, usability, and user acceptance as well as issues related to power consumption, real-time operations, sensing limitations, privacy and record of real-life falls.


Assuntos
Acidentes por Quedas , Acelerometria , Telefone Celular , Humanos , Monitorização Fisiológica
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...