Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
1.
Radiat Prot Dosimetry ; 200(2): 149-154, 2024 Feb 16.
Artigo em Inglês | MEDLINE | ID: mdl-37987214

RESUMO

The aim of this study was to estimate the administered dosage of 81mKr noble gas as calculated by the radioactivity of 81Rb-rubidium hydroxide (81RbOH). The administered dosage was regarded as the total amount of 81mKr noble gas. The radioactivity of 81mKr was calculated using the radioactivity of 81RbOH at the examination, the beginning of inhalation, the inhalation duration and the attenuation volume from the generator to the patient for 81mKr noble gas. In addition, we created an Internet survey and asked National University Hospital in Japan to respond to questions regarding the parameters of concern. Survey responses were provided by 38 hospitals (response rate was 90.5%). Twenty-seven hospitals (64.3%) examined lung ventilation scintigraphy using 81mKr noble gas. The mean administered dosage and the effective dose of lung ventilation scintigraphy using 81mKr noble gas were 35.8 ± 22.1 GBq and 0.97 ± 0.60 mSv, respectively.


Assuntos
Pulmão , Rubídio , Humanos , Cintilografia , Pulmão/diagnóstico por imagem , Japão
2.
Ann Nucl Med ; 37(8): 470-477, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-37306918

RESUMO

OBJECTIVE: This study was aimed at determining the minimum acquisition count to provide diagnosable image quality (DIQ) and investigating the usefulness of preset count acquisition (PCA) for planar images of pediatric 99mTc-dimercaptosuccinic acid (DMSA) scintigraphy. METHODS: First, we calculated a coefficient of variation (CV) for DIQ with the shortest acquisition time through visual evaluation in 12 pediatric patients who underwent 99mTc-DMSA scintigraphy. Second, a minimum acquisition count to achieve the CV for DIQ was determined with the single regression analysis using CV as an explanatory variable and the total acquisition count as an objective variable in 81 pediatric patients. Finally, we compared PCA images based on the minimum acquisition count and preset time acquisition (PTA) images for 5 min in terms of the acquisition time, CV, and renal uptake ratio in another 23 pediatric patients. RESULTS: The visual evaluation showed that the CV corresponding to DIQ with the shortest acquisition time was 27.1%. The total acquisition count corresponding to DIQ was revealed to be 299,764 in the single regression analysis and was determined to be 300,000 after rounding. The CV and its standard deviation in PCA at 300,000 counts and PTA for 5 min were 26.4 ± 0.6% and 24.8 ± 1.3%, respectively. The standard deviation of CV in PCA at 300,000 counts was smaller than that in PTA for 5 min, indicating little variation in image quality between cases. The acquisition time in PCA at 300,000 counts (3.1 ± 0.7 min) was shorter than that in PTA for 5 min (5.0 ± 0.0 min). The intraclass correlation coefficient between renal uptake ratios for PCA and PTA was 0.98, indicating an extremely high concordance. CONCLUSIONS: The minimum acquisition count required for the DIQ was 300,000. In addition, PCA at 300,000 counts was demonstrated to be useful by providing stable image quality at the shortest acquisition time.


Assuntos
Rim , Ácido Dimercaptossuccínico Tecnécio Tc 99m , Criança , Humanos , Cintilografia , Rim/diagnóstico por imagem , Análise de Regressão , Transporte Biológico , Compostos Radiofarmacêuticos
3.
Eur J Radiol ; 135: 109477, 2021 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-33401111

RESUMO

PURPOSE: To investigate whether or not 18F-FDG accumulation in normal or less-affected lung fields increased in non-small cell lung cancer (NSCLC) patients with postoperative acute exacerbation (PAE) of interstitial lung disease (ILD) MATERIAL AND METHODS: Thirty-six NSCLC patients with ILD and 50 patients without ILD (non-ILD patients) underwent pre-operative 18F-FDG-PET/CT at 2 institutions. Volume-of-interest (VOI) was placed to measure the mean standardized uptake value (SUVmean) in normal or less-affected lung fields at pre-defined 12 areas on ventral and dorsal locations of both lungs. SUVtissue fraction (TF) was defined as corrected SUVmean by using TF and mean computed tomography density on PET/CT. Harmonized SUVmean (hSUVmean) and SUVTF (hSUVTF) were calculated based on results of phantom study, which was performed to optimize the measured SUV difference among 2 institutions. Both the h-SUVmean and the h-SUVTF were compared between 8 patients with PAE of ILD (PAE group) or remaining 28 patients without PAE of ILD (non-PAE group) and non-ILD patients in each of the 12 areas. RESULTS: The hSUVmean in PAE group was higher in 9 out of 12 locations as compared with non-ILD patients, whereas the hSUVmean was mostly similar between non-PAE group and non-ILD patients. In contrast, the hSUVTF in non-PAE group was similar to that in PAE group, and higher than in non-ILD patients in most locations. CONCLUSION: 18F-FDG-PET/CT demonstrated increased SUVmean along with elevated SUVTF in normal or less-affected lung fields for NSCLC patients with PAE of ILD, which may reflect regional invisible fibrosis and inflammatory change.


Assuntos
Carcinoma Pulmonar de Células não Pequenas , Doenças Pulmonares Intersticiais , Neoplasias Pulmonares , Carcinoma Pulmonar de Células não Pequenas/complicações , Carcinoma Pulmonar de Células não Pequenas/diagnóstico por imagem , Carcinoma Pulmonar de Células não Pequenas/cirurgia , Fluordesoxiglucose F18 , Humanos , Pulmão , Doenças Pulmonares Intersticiais/diagnóstico por imagem , Neoplasias Pulmonares/complicações , Neoplasias Pulmonares/diagnóstico por imagem , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada
4.
Nihon Hoshasen Gijutsu Gakkai Zasshi ; 62(6): 840-7, 2006 Jun 20.
Artigo em Japonês | MEDLINE | ID: mdl-16799412

RESUMO

Attenuation correction is necessary for the reconstruction of SPECT images. One report has mentioned that attenuation correction by X-ray computed tomography (CT) is effective for a non-uniform attenuation body. We examined the effect of attenuation correction on SPECT images by changing the scanning conditions of CT, and evaluated the possibility of attenuation correction by low-dose CT. The phantom was scanned under several X-ray tube conditions varying from 80 kV to 135 kV and from 7.5 mAs to 200 mAs. We obtained equations of attenuation correction based on the Hounsfield Unit (HU) units of each pixel and compared the effects of attenuation correction. The results showed that the equation for attenuation correction under each condition did not vary significantly, and the effects of attenuation correction by the equations did not vary significantly between CT of low dose and that of clinical dose. This result suggest that the attenuation correction obtained by low-dose CT was equal to that obtained by the clinical dose. In conclusion, it seemed that the equation and map of attenuation correction matched with each radionuclide yielded more adequate attenuation correction than conventional methods.


Assuntos
Processamento de Imagem Assistida por Computador/métodos , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Tomografia Computadorizada por Raios X , Processamento de Imagem Assistida por Computador/instrumentação , Imagens de Fantasmas , Doses de Radiação , Tomografia Computadorizada de Emissão de Fóton Único/instrumentação
5.
Nihon Hoshasen Gijutsu Gakkai Zasshi ; 59(4): 514-21, 2003 Apr.
Artigo em Japonês | MEDLINE | ID: mdl-12743523

RESUMO

Societies concerned with radioactive rays and nuclear medicine have recently highlighted the necessity of managing radioactive medical waste resulting from nuclear medicine examinations. We introduce a manual that we have created and explain its use in decision-making and management practices aimed at the reduction of radioactive medical waste at hospitals that have not yet solved this problem. We hope that our manual will help in reducing this medical waste.


Assuntos
Manuais como Assunto , Eliminação de Resíduos de Serviços de Saúde/métodos , Resíduos Radioativos , Japão , Compostos Radiofarmacêuticos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...