Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 17 de 17
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Magn Reson Med Sci ; 23(2): 146-152, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-36740257

RESUMO

PURPOSE: To evaluate the feasibility of breath-hold (BH) high-resolution (HR) T1-weighted gradient echo hepatobiliary phase (HBP) imaging using compressed sensing (CS) in gadoxetic acid-enhanced liver MRI in comparison with standard HBP imaging using parallel imaging (PI). METHODS: The study included 122 patients with liver tumors with hypointensity in the HBP who underwent both HR HBP imaging with CS and standard HBP imaging with PI. Two radiologists evaluated the liver edge sharpness, hepatic vessel conspicuity, bile duct conspicuity, image noise, and overall image quality, as well as the lesion conspicuity on HR and standard HBP imaging and the contrast-enhanced (CE) MR cholangiography (MRC) image quality reconstructed from HBP images. As a quantitative analysis, the SNR of the liver and the liver to lesion signal intensity ratio (LLSIR) were also determined. RESULTS: The liver edge sharpness, hepatic vessel conspicuity, bile duct conspicuity, and overall image quality as well as the lesion conspicuity and the LLSIR on HR HBP imaging with CS were significantly higher than those on standard HBP imaging (all of P < 0.001). The image quality of CE-MRC reconstructed from HR HBP imaging with CS was also significantly higher than that from standard HBP imaging (P < 0.001). Conversely, the SNR of liver in standard HBP was significantly higher than that in HR HBP with CS (P < 0.001). CONCLUSION: BH HR HBP imaging with CS provided an improved overall image quality, lesion conspicuity, and CE-MRC visualization when compared with standard HBP imaging without extending the acquisition time.


Assuntos
Meios de Contraste , Imageamento Tridimensional , Humanos , Imageamento Tridimensional/métodos , Fígado/diagnóstico por imagem , Fígado/patologia , Gadolínio DTPA , Imageamento por Ressonância Magnética/métodos , Aumento da Imagem/métodos , Estudos Retrospectivos
2.
Curr Med Imaging ; 2023 Oct 14.
Artigo em Inglês | MEDLINE | ID: mdl-37881086

RESUMO

BACKGROUND: Non-neoplastic liver lesions show low signal intensity in the hepatobiliary phase (HBP) of gadoxetic acid-enhanced magnetic resonance imaging (EOB-MRI) after biliary stenting and require differentiation from liver metastases. OBJECTIVE: The study aimed to evaluate the imaging findings and clinical association of non-neoplastic liver lesions showing hypointensity in the HBP of EOB-MRI after biliary stenting, and assess their differentiation from liver metastases. METHODS: This study included 30 patients who underwent EOB-MRI after biliary stenting for pancreaticobiliary malignancies. Among these, 7 patients had pathologically diagnosed non-neoplastic liver lesions, which appeared hypointense in the HBP, and were categorized into the non-neoplastic group. The remaining 23 patients without non-neoplastic liver lesions were included in the control group. Additionally, 29 patients with liver metastasis were included in the liver metastasis group. Clinical associations and imaging features were compared between the groups. RESULTS: A history of cholangitis and two or more biliary interventional procedures were significantly more frequently observed in the non-neoplastic group (p=0.002 and p=0.01, respectively) than in the control groups. Regarding the imaging findings, the liver-to-lesion signal intensity ratio in the HBP in the liver metastasis group was significantly higher than that in the non-neoplastic group (2.13 vs. 1.53, p=0.002). Additionally, liver metastases were visualized significantly more clearly on diffusion-weighted images (p=0.033) and HBP images (p<0.001) in comparison to non-neoplastic lesions. CONCLUSION: Non-neoplastic liver lesions due to biliary inflammation may be observed in the HBP of EOB-MRI in patients after biliary stenting. These lesions may be associated with a history of cholangitis and repeated biliary intervention procedure, and need to be differentiated from liver metastases.

3.
Eur J Radiol ; 168: 111138, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37832196

RESUMO

PURPOSE: Modified reduced FOV diffusion-weighted imaging (DWI) using spatially-tailored 2D RF pulses with tilted excitation plane (tilted r-DWI) has been developed. The purpose of this study was to evaluate the impact on image quality and quantitative apparent diffusion coefficient (ADC) values of tilted r-DWI for pancreatic ductal adenocarcinomas (PDAC) in comparison to conventional full-FOV DWI (f-DWI). METHODS: This retrospective study included 21 patients (mean 70.7, range 50-85 years old) with pathologically confirmed PDAC. All MR images were obtained using 3 T systems. Two radiologists evaluated presence of blurring or ghost artifacts, susceptibility artifacts, and aliasing artifacts; anatomic visualization of the pancreas; interslice signal homogeneity; overall image quality; and conspicuity of the PDAC. For quantitative analysis, contrast-to-noise ratio (CNR), signal-to-noise ratio (SNR), signal-intensity ratio (SIR) and ADC values were measured using regions of interest. RESULTS: All image quality scores except aliasing artifacts in tilted r-DWI were significantly higher than those in f-DWI (p < 0.01). The CNR and SIR of PDAC were significantly higher in tilted r-DWI than in f-DWI (6.7 ± 4.4 vs. 4.7 ± 3.9, 2.02 ± 0.72 vs. 1.72 ± 0.60, p < 0.01). Conversely, the SNR of PDAC in tilted r-DWI was significantly lower than that in f-DWI (56.0 ± 33.1 vs. 113.6 ± 67.3, p < 0.01). No significant difference was observed between mean ADC values of the PDAC calculated from tilted r-DWI (tilted r-ADC) and those from f-DWI (f-ADC) (1225 ± 250 vs. 1294 ± 302, p = 0.11). CONCLUSION: The r-DWI using 2D RF techniques with a tilted excitation plane was shown to significantly improve the image quality and CNR and reduce image artifacts compared to f-DWI techniques in MRI evaluations of PDAC without significantly affecting ADC values.


Assuntos
Adenocarcinoma , Carcinoma Ductal Pancreático , Neoplasias Pancreáticas , Humanos , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Neoplasias Pancreáticas/diagnóstico por imagem , Adenocarcinoma/diagnóstico por imagem , Estudos Retrospectivos , Imagem de Difusão por Ressonância Magnética/métodos , Imageamento por Ressonância Magnética , Carcinoma Ductal Pancreático/diagnóstico por imagem , Reprodutibilidade dos Testes , Imagem Ecoplanar/métodos , Neoplasias Pancreáticas
4.
Tomography ; 9(5): 1568-1576, 2023 08 23.
Artigo em Inglês | MEDLINE | ID: mdl-37736978

RESUMO

This study investigated the feasibility of both a reduced radiation dose and a 50% of contrast dose in multiphasic CT of the liver with a 70 kVp protocol compared with a standard-tube-voltage protocol derived from dual-energy (DE) CT (blended DE protocol) with a full-dose contrast-agents in the same patient group. This study included 46 patients who underwent multiphasic contrast-enhanced dynamic CT of the liver with both a 70 kVp and a blended DE protocols. For quantitative analysis, median CT values for the liver, aorta, and portal vein, as well as signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR), were measured and calculated. In addition, as a qualitative analysis, the contrast effect and overall image quality of the abdominal organs were evaluated on a five-point scale. CNR and SNR of the hepatic parenchyma were not significantly different between the 70kV protocol and the Blended DE protocol in all phases. The 70 kVp protocol showed significantly better image quality compared with the blended DE protocol in the arterial phase (p = 0.035) and the equilibrium layer phase (p = 0.016). A 70 kVp CT protocol in combination with a reduced radiation dose and half-dose iodine load is feasible for multiphasic dynamic CT of the liver by maintaining the contrast enhancement effects and image quality in comparison with the blended DE CT protocol.


Assuntos
Artérias , Fígado , Humanos , Estudos de Viabilidade , Fígado/diagnóstico por imagem , Doses de Radiação , Tomografia Computadorizada por Raios X
5.
Radiol Med ; 128(10): 1192-1198, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37606795

RESUMO

PURPOSE: To evaluate the image quality qualitatively and quantitatively, as well as apparent diffusion coefficient (ADC) values of modified reduced field-of-view diffusion-weighted magnetic resonance imaging (MRI) using spatially tailored two-dimensional radiofrequency pulses with tilted excitation plane (tilted r-DWI) based on single-shot echo planar imaging (SS-EPI) compared with full-size field-of-view DWI (f-DWI) using readout segmented (RS)-EPI in patients with rectal cancer. MATERIALS AND METHODS: Twenty-two patients who underwent an MRI for further evaluation of rectal cancer were included in this retrospective study. All MR images were analyzed to compare image quality, lesion conspicuity, and artifacts between f-DWI with RS-EPI and tilted r-DWI with SS-EPI. Signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and ADC values were also compared. The Wilcoxon signed-rank test or paired t test was performed to compare the qualitative and quantitative assessments. RESULTS: All image quality scores, except aliasing artifacts, were significantly higher (p < 0.01 for all) in tilted r-DWI than f-DWI with RS-EPI. CNR in tilted r-DWI was significantly higher than in f-DWI with RS-EPI (p < 0.01), while SNR was not significantly different. Regarding the ADC values, no significant difference was observed between tilted r-DWI and f-DWI with RS-EPI (p = 0.27). CONCLUSION: Tilted r-DWI provides a better image quality with fewer artifacts and higher rectal lesion conspicuity than f-DWI with RS-EPI, indicating the feasibility of this MR sequence in evaluating rectal cancer in clinical practice.


Assuntos
Imagem Ecoplanar , Neoplasias Retais , Humanos , Imagem Ecoplanar/métodos , Estudos Retrospectivos , Razão Sinal-Ruído , Neoplasias Retais/diagnóstico por imagem , Imagem de Difusão por Ressonância Magnética/métodos , Reprodutibilidade dos Testes
6.
Eur J Radiol ; 160: 110688, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-36630843

RESUMO

PURPOSE: This study aimed to evaluate the association of portal flow hemodynamics with lobar hepatic steatosis by means of dynamic contrast-enhanced (DCE) CT. METHODS: The study population consisted of 235 patients, 77 with lobar hepatic steatosis (right, n = 67; left, n = 10), 158 with diffuse hepatic steatosis with (n = 76) and without (n = 82) a focal fatty spared area. CT attenuation values (Hounsfield units: HU) of the liver with and without hepatic steatosis were measured in unenhanced and arterial-phase CT. The contrast enhancement (CE) values were calculated as the difference in HU values between unenhanced and arterial-phase CT. RESULTS: In 67 patients with lobar steatosis of the right lobe, the median CE values of the areas of right lobar steatosis were significantly lower than those of the non-fatty left lobe (13 [IQR 7-19] vs 23 [13-33] HU, P < 0.01), suggesting dominant SMV flow to the right lobe with lobar hepatic steatosis. Conversely, in 10 patients with lobar steatosis of the left lobe, the median CE values of the areas of left lobar steatosis were lower than those of the non-fatty right lobe (15.5 [11.75-21.5] vs 16 [14.5-22] HU); however, this difference was not statistically significant (P = 0.20). In 76 patients with a focal fatty spared area, there were significant differences in the median CE values between hepatic steatosis areas and focal fatty spared areas in the gallbladder fossa group (P = 0.01) and in the segment IV group (P < 0.01). CONCLUSION: Lobar hepatic steatosis may be associated with regional changes of the portal flow hemodynamics (i.e., predominant perfusion from the SMV flow to the lobes with steatosis).


Assuntos
Fígado Gorduroso , Humanos , Fígado Gorduroso/diagnóstico por imagem , Fígado , Tomografia Computadorizada por Raios X , Estudos Retrospectivos
7.
Tomography ; 8(6): 2806-2814, 2022 11 24.
Artigo em Inglês | MEDLINE | ID: mdl-36548526

RESUMO

This study investigated the relationship between the severity of pneumonia based on chest CT findings and that of pancreatic steatosis assessed using an automated volumetric measurement of the CT fat volume fraction (CT-FVF) of the pancreas, using unenhanced three-dimensional CT in polymerase chain reaction (PCR)-confirmed COVID-19 patients. The study population consisted of 128 patients with PCR-confirmed COVID-19 infection who underwent CT examinations. The CT-FVF of the pancreas was calculated using a histogram analysis for the isolation of fat-containing voxels in the pancreas. The CT-FVF (%) of the pancreas had a significantly positive correlation with the lung severity score on CT (ρ = 0.549, p < 0.01). CT-FVF (%) of the pancreas in the severe pneumonia group was significantly higher than that of the non-severe pneumonia group (21.7% vs. 7.8%, p < 0.01). The area under the curve of CT-FVF (%) of the pancreas in predicting the severity of pneumonia on CT was calculated to be 0.82, with a sensitivity of 88% and a specificity of 68% at a threshold for the severity score of 12.3. The automated volumetric measurement of the CT-FVF of the pancreas using unenhanced CT can help estimate disease severity in patients with COVID-19 pneumonia based on chest CT findings.


Assuntos
COVID-19 , Pneumonia , Humanos , COVID-19/diagnóstico por imagem , Pulmão/diagnóstico por imagem , Pâncreas/diagnóstico por imagem , Tomografia Computadorizada de Feixe Cônico
8.
Tomography ; 8(2): 815-823, 2022 03 16.
Artigo em Inglês | MEDLINE | ID: mdl-35314644

RESUMO

BACKGROUND: A variety of pathophysiological changes in the biliary system occur in patients with cholelithiasis, but the changes in the bile flow dynamics in those patients remain unclear. The purpose of this study was to elucidate the changes in the bile flow dynamics in patients with cholelithiasis using cine-dynamic magnetic resonance cholangiopancreatography (MRCP) with a spatially selective inversion-recovery (IR) pulse. METHODS: We retrospectively examined 25 patients with gallstones (gallstone group) and 69 patients without gallstones (non-gallstone group) who underwent abdominal MRI, including in- and opposed-phase T1-weighted images and cine-dynamic MRCP with a spatially selective IR pulse. The frequency and secretion grade of the antegrade and reverse flow of the bile on the cine dynamic MRCP images and the signal intensity ratio (SIR) of the gallbladder in the in- and opposed-phase T1-weighted images were evaluated. RESULTS: The frequency and mean secretion grade of the antegrade bile flow were significantly higher in the gallstone group than in the non-gallstone group (p = 0.011 and p = 0.003), while no significant differences in those values of the reverse bile flow were found between the two groups. The SIR of the gallbladder in the T1-weighted gradient-echo in-phase images was significantly lower in the gallstone group than in the non-gallstone group (p = 0.004). CONCLUSIONS: Cine-dynamic MRCP with a spatially selective IR pulse can noninvasively visualize changes in the bile flow dynamics of patients with gallstones.


Assuntos
Colangiopancreatografia por Ressonância Magnética , Cálculos Biliares , Bile , Colangiopancreatografia por Ressonância Magnética/métodos , Humanos , Imageamento por Ressonância Magnética , Estudos Retrospectivos
9.
Br J Radiol ; 95(1135): 20210854, 2022 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-35348358

RESUMO

OBJECTIVE: Major liver resection is an effective treatment option for patients with liver malignancy. The future liver remnant (FLR) volume and complications after portal vein embolization (PVE) were compared between the ipsilateral right portal vein (PTPE) and transileocolic (TIPE) approaches. METHODS: A total of 42 patients (TIPE, n = 22; PTPE, n = 20) underwent right lobectomy after PVE. CT and hepatobiliary scintigraphy were repeated before and after PVE. The blood examination findings and the FLR values (FLRCT: calculated from CT, %FLRCT: FLRCT ratio, %FLRSPECT: FLR ratio using single photon emission CT, FLRCT/BS: FLRCT to body surface ratio) were compared between two approach sites. The complications and mortality were also analyzed after PVE and major right hepatectomy. RESULTS: There were no significant differences in the patient characteristics, blood examination findings or FLR values between two groups. Adequate liver regeneration was observed without significant differences between PTPE and TIPE (increased ratio of FLRCT: 8.7% vs 19.2%, p = 0.15 [25-75 percentile: 17.1-60.4], %FLRCT: 11.2% vs 8.3%, p = 0.25 [6.3-13.3], %FLRSPECT: 15.4% vs 19.2%, p = 0.09 [16.0-22.4], FLRCT/BS: 33.6% vs 47.1%, p = 0.19 [17.2-60.4], respectively), but TIPE required a significantly longer procedure time than PTPE [181.4 min vs 108.7 min, p < 0.01 (103.3-193.5)]. However, one patient was converted to TIPE due to bleeding during PTPE. After right lobectomy, portal vein stenosis or thrombosis was noted in three patients [two with TIPE (9.1%) and one with PTPE (5%)] and three TIPE patients died within 90 days (13.6%) after right hepatectomy. CONCLUSION: FLR volume significantly increased after PVE, regardless of the approach sites; however, PTPE is a useful technique with a shorter procedure time.


Assuntos
Embolização Terapêutica , Neoplasias Hepáticas , Embolização Terapêutica/métodos , Hepatectomia/métodos , Humanos , Fígado/diagnóstico por imagem , Fígado/patologia , Fígado/cirurgia , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/cirurgia , Veia Porta/patologia , Resultado do Tratamento
10.
J Magn Reson Imaging ; 55(4): 1234-1240, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-34331482

RESUMO

BACKGROUND: To resolve drawbacks of navigator triggering (NT) three-dimensional (3D) magnetic resonance cholangiopancreatography (MRCP), several approaches were proposed to obtain 3D MRCP within a single breath-hold (BH). However, reduced field-of-view technique in the phase-encoding direction combined with two-dimensional spatially selective radiofrequency excitation pulses has not yet been applied to 3D BH MRCP. PURPOSE: To investigate the feasibility and the complementary value of 3D BH zoomed MRCP to conventional 3D NT MRCP in patients with branch duct intraductal papillary mucinous neoplasms (BD-IPMNs) of the pancreas. STUDY TYPE: Retrospective. POPULATION: A total of 221 patients (116 male and 105 female, median age 73 years) with BD-IPMNs. FIELD STRENGTH/SEQUENCE: 3.0 T/3D turbo spin echo ASSESSMENT: MR images were analyzed by three radiologists (R.M., H.O., M.T., with 1, 13, and 17 years of experience) to compare blurring and motion artifacts, background suppression, visualization of main pancreatic duct (MPD), conspicuity of BD-IPMN, and overall image quality. STATISTICAL TESTS: Wilcoxon-signed rank, Mann-Whitney U, chi-squared or Fisher's exact tests (P < 0.05). RESULTS: Image quality was significantly higher on 3D NT MRCP images than on 3D BH zoomed MRCP (median (interquartile range); background suppression, 4 (4-4) vs. 3 (3-4); visualization of MPD, 4 (3-4) vs. 4 (3-4), conspicuity of BD-IPMN, 4 (3-4) vs. 3 (3-4); and overall image quality, 3 (3-4) vs. 3 (3-3)). However, in 32 (14%) patients, 3D NT MRCP showed a score of 1 or 2 in overall image quality. Regarding the conspicuity of BD-IPMN, a conspicuity score of 1 or 2 was rendered in 31 (14%) patients in 3D NT MRCP group. Conversely, 3D BH zoomed MRCP showed a score of 3 or 4 in 29 (94%) of these 31 patients. DATA CONCLUSION: 3D BH zoomed MRCP plays a complementary role to 3D NT MRCP, and may improve the conspicuity of BD-IPMNs in patients with irregular breathing pattern. LEVEL OF EVIDENCE: 4 TECHNICAL EFFICACY: Stage 2.


Assuntos
Neoplasias Intraductais Pancreáticas , Neoplasias Pancreáticas , Idoso , Suspensão da Respiração , Colangiopancreatografia por Ressonância Magnética/métodos , Feminino , Humanos , Imageamento Tridimensional/métodos , Masculino , Neoplasias Pancreáticas/diagnóstico por imagem , Estudos Retrospectivos
11.
Eur J Radiol ; 146: 110067, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-34847396

RESUMO

PURPOSE: To evaluate the image quality of ultra-high-resolution CT (U-HRCT) in the comparison among four different reconstruction methods, focusing on the gastric wall structure, and to compare the conspicuity of a three-layered structure of the gastric wall between conventional HRCT (C-HRCT) and U-HRCT. METHOD: Our retrospective study included 48 patients who underwent contrast-enhanced U-HRCT. Quantitative analyses were performed to compare image noise of U-HRCT between deep-learning reconstruction (DLR) and other three methods (filtered back projection: FBP, hybrid iterative reconstruction: Hybrid-IR, and Model-based iterative reconstruction: MBIR). The mean overall image quality scores were also compared between the DLR and other three methods. In addition, the mean conspicuity scores for the three-layered structure of the gastric wall at five regions were compared between C-HRCT and U-HRCT. RESULTS: The mean noise of U-HRCT with DLR was significantly lower than that with the other three methods (P < 0.001). The mean overall image quality scores with DLR images were significantly higher than those with the other three methods (P < 0.001). Regarding the comparison between C-HRCT and U-HRCT, the mean conspicuity scores for the three-layered structure of the gastric wall on U-HRCT were significantly better than those on C-HRCT in the fornix (5 [5-5] vs. 3.5 [3-4], P < 0.001), body (4 [3.25-5] vs. 4 [3-4], P = 0.039), angle (5 [4-5] vs. 3 [2-4], P < 0.001), and antral posterior (4 [3.25-5] vs. 2 [2-4], P < 0.001), except for antral anterior (4 [3-5] vs. 3 [3-4], P = 0.230) CONCLUSION: U-HRCT using DLR improved the image noise and overall image quality of the gastric wall as well as the conspicuity of the three-layered structure, suggesting its utility for the evaluation of the anatomical details of the gastric wall structure.


Assuntos
Aprendizado Profundo , Interpretação de Imagem Radiográfica Assistida por Computador , Algoritmos , Humanos , Doses de Radiação , Estudos Retrospectivos , Tomografia Computadorizada por Raios X
12.
J Magn Reson Imaging ; 54(6): 1902-1911, 2021 12.
Artigo em Inglês | MEDLINE | ID: mdl-34121262

RESUMO

BACKGROUND: The physiological flow patterns and the reciprocal relationship between pancreatic juice and bile excretion dynamics have not been clearly elucidated by imaging. PURPOSE: To assess the physiological flow patterns of bile and pancreatic juice simultaneously in order to clarify the pancreatobiliary flow dynamics using cine-dynamic magnetic resonance cholangiopancreatography (MRCP) with a spatial selective inversion recovery (IR) pulse. STUDY TYPE: Retrospective. POPULATION: A total of 85 patients with physiologically normal pancreatobiliary flow without ductal dilatation (normal group) and 19 patients with dilated pancreatic duct. FIELD STRENGTH/SEQUENCE: A 3 T, fast spin echo sequence with IR pulse to nullify the signal of static pancreatic juice and bile. ASSESSMENT: The frequency and secretion grade of the antegrade and reverse flow of the pancreatic juice and bile on cine-dynamic MRCP were visually evaluated. Additionally, the reciprocal relationship between pancreatic juice and bile flow was evaluated based on its flow patterns. STATISTICAL TESTS: Spearman's rank correlation coefficient analysis and the Kruskal-Wallis and Mann-Whitney U tests were used. P values of <0.05 were considered to indicate statistical significance. RESULTS: In the normal group, the antegrade pancreatic juice flow and no bile flow pattern was most frequently observed (29%), followed by the no pancreatic juice flow and no bile flow pattern (23%), the antegrade pancreatic juice flow and antegrade bile flow pattern (22%), and the no pancreatic juice flow and reverse bile flow pattern (9%). The flow of the pancreatic juice and bile were synchronized with each other in 47%, while they were not in 53%. In the dilated pancreatic duct group, the mean secretion grade of the antegrade bile and pancreatic juice flow was significantly lower than in the normal group. DATA CONCLUSION: Cine-dynamic MRCP with a spatially selective IR pulse can visualize the variations of the physiological flow patterns of bile and pancreatic juice including 53% of unsynchronized patterns. LEVEL OF EVIDENCE: 4 TECHNICAL EFFICACY: Stage 5.


Assuntos
Colangiopancreatografia por Ressonância Magnética , Suco Pancreático , Bile , Dilatação Patológica , Humanos , Ductos Pancreáticos/diagnóstico por imagem , Estudos Retrospectivos
13.
Jpn J Radiol ; 39(9): 900-906, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-33963466

RESUMO

PURPOSE: To evaluate the hemodynamic changes in the liver, pancreas, gastric mucosa and abdominal vessels in early-phase dynamic contrast-enhanced (DCE) CT immediately after CT colonography (CTC) with carbon dioxide expansion. MATERIALS AND METHODS: This study included 82 patients with DCE-CT after CTC (CTC group) and 77 patients without CTC (control group). Contrast enhancement values of the gastric mucosa, liver, pancreas, portal vein (PV), splenic vein (SpV), superior mesenteric vein (SMV), and inferior mesenteric vein (IMV) in early-phase CT were measured. The presence of hepatic pseudolesions were also recorded. RESULTS: The mean contrast enhancement values of the gastric mucosa, pancreas and SpV in the CE-CTC group were significantly lower than those in the control group (p < 0.001, p < 0.001, p = 0.014). Conversely, the mean contrast enhancement values of the liver, PV, SMV and IMV in the CE-CTC group were significantly higher than those in the control group (p = 0.003, p = 0.013, p < 0.001, p < 0.001). Hypovascular hepatic pseudolesions were seen in early-phase CT in six patients after CTC, while they were not seen in the control group. CONCLUSIONS: On DCE-CT performed immediately after CTC with carbon dioxide expansion, it is important to be aware of the imaging findings induced by visceral hemodynamic changes.


Assuntos
Dióxido de Carbono , Colonografia Tomográfica Computadorizada , Meios de Contraste , Hemodinâmica , Humanos , Veia Porta
14.
Eur J Radiol ; 141: 109775, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-34020172

RESUMO

PURPOSE: To investigate the clinical value of measuring the ECV fraction of the pancreas by DECT in association with an impaired glucose tolerance (IGT) estimated by the hemoglobin A1C (HbA1C) value in patients with or without cirrhosis. MATERIALS AND METHODS: This retrospective study included patients who underwent contrast-enhanced dynamic CT with dual-energy mode between March 2018 and February 2019. The ECV fraction of the pancreas was calculated from iodine map images created from equilibrium-phase contrast-enhanced DECT images. The cross-sectional areas of the pancreas were also measured. RESULTS: In total, 51 patients were analyzed (median age, 69 years old; 22 women). The ECV fraction of the pancreas showed a significant negative correlation with the HbA1c value in the cirrhotic group (ρ=-0.346, p = 0.048), while there was no significant correlation in the non-cirrhotic group (ρ=-0.086, p = 0.734). In the elevated HbA1C group, the ECV fraction of the pancreas in the cirrhotic patients (median, 0.247; interquartile range [IQR], 0.098) was significantly lower than that in the non-cirrhotic patients (0.332, IQR 0.113) (p = 0.024). In the elevated HbA1C group, the cross-sectional area of the pancreas was significantly larger in the cirrhotic patients than that in the non-cirrhotic patients (median [IQR]; 2945 [904] vs. 1885 [909] mm2, p = 0.019). CONCLUSION: A reduction in the ECV fraction of the pancreas measured by DECT as well as the enlargement of the pancreatic parenchyma was observed in cirrhotic patients with IGT. These findings suggest that the measurement of the pancreatic ECV fraction by DECT may help clarify the pathophysiology of IGT in patients with cirrhosis.


Assuntos
Intolerância à Glucose , Idoso , Meios de Contraste , Feminino , Humanos , Pâncreas/diagnóstico por imagem , Estudos Retrospectivos , Tomografia
15.
J Magn Reson Imaging ; 54(3): 715-720, 2021 09.
Artigo em Inglês | MEDLINE | ID: mdl-33704860

RESUMO

BACKGROUND: Reduced field-of-view diffusion-weighted imaging (rDWI) with tilted two-dimensional radiofrequency (RF) excitation planes has not yet been applied to the imaging of the pancreas although the utility of this technique which allows the acquisition of high-quality images without aliasing artifacts in the phase-encoding direction has been evaluated for brain and spinal cord imaging. PURPOSE: To evaluate the visual image quality of the pancreas by tilting the excitation plane (tilted rDWI) in comparison to conventional DWI (cDWI) and rDWI without using the tilted excitation plane. STUDY TYPE: Retrospective. POPULATION: Thirty-two patients evaluated for suspected pancreatobiliary diseases. FIELD STRENGTH/SEQUENCE: Echo-planar imaging DWI (cDWI, rDWI, and tilted rDWI) acquired at 3 T. ASSESSMENT: Images from each DWI sequence were analyzed by five radiologists to compare image quality (conspicuity of pancreatic edges, interslice signal homogeneity, overall image quality, and conspicuity of focal pancreatic lesions) and artifacts (presence of blurring or ghosting artifacts, susceptibility artifacts, and aliasing artifact). STATISTICAL TESTS: Shapiro-Wilk test was performed to assess whether data were normally distributed. Friedman test followed by Bonferroni-adjusted Wilcoxon signed-rank test for post hoc analysis was performed to compare image quality and artifact scores. RESULTS: The mean scores for conspicuity of pancreatic edges (3.36 vs. 2.37), interslice signal homogeneity (3.14 vs. 2.81), presence of ghosting artifacts (3.32 vs. 2.66), susceptibility artifacts (3.06 vs. 2.30), and aliasing artifacts (3.90 vs. 2.34), and overall image quality (3.49 vs. 2.36) were significantly higher in the tilted rDWI than in the rDWI (P < 0.017 for all parameters). The conspicuity score for focal pancreatic lesions tended to be higher in tilted rDWI than in rDWI (2.44 vs. 2.00, P = 0.07). DATA CONCLUSION: Tilted rDWI had better image quality and reduced artifacts relative to cDWI and rDWI techniques in the pancreas. LEVEL OF EVIDENCE: 4 TECHNICAL EFFICACY: Stage 2.


Assuntos
Imagem de Difusão por Ressonância Magnética , Imagem Ecoplanar , Artefatos , Humanos , Imageamento por Ressonância Magnética , Pâncreas/diagnóstico por imagem , Reprodutibilidade dos Testes , Estudos Retrospectivos
16.
Jpn J Radiol ; 39(2): 178-185, 2021 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-32959222

RESUMO

PURPOSE: To compare the occurrence of transient respiratory motion artifacts (TRMAs) in multiple arterial phases on abdominal magnetic resonance (MR) images between those obtained using gadobutrol and gadoxetate disodium. MATERIALS AND METHODS: Two hundred and fourteen abdominal MR examinations (101 with gadoxetate disodium, 113 with gadobutrol) were evaluated. Dynamic three-dimensional contrast-enhanced T1-weighted imaging (CAIPIRINHA-Dixon-TWIST-VIBE) including single-breath-hold six arterial phase acquisitions was performed on a 3.0-T MRI scanner. The TRMAs frequency and the mean TRMA scores were compared between patients assessed with gadoxetate disodium and those assessed with gadobutrol. In addition, the timing of TRMAs appearing for the first time was also recorded and compared between the two groups. RESULTS: The mean TRMA scores in all arterial phases using gadoxetate disodium were significantly worse than in those using gadobutrol (1.49 ± 0.78 vs. 1.18 ± 0.53, P < .001). Regarding the timing of the occurrence of TRMAs, the severe TRMAs frequency after the third arterial phase was significantly higher in patients using gadoxetate disodium (10/101, 10%) than in those using gadobutrol (0/113, 0%) (P < .001). CONCLUSION: In multiple-arterial-phase dynamic MRI, the TRMAs frequency when using gadoxetate disodium increased compared with gadobutrol, due to intolerable respiratory suspension after the third arterial phase.


Assuntos
Abdome/diagnóstico por imagem , Artefatos , Meios de Contraste , Gadolínio DTPA , Fígado/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Compostos Organometálicos , Adulto , Idoso , Idoso de 80 Anos ou mais , Artérias/diagnóstico por imagem , Suspensão da Respiração , Meios de Contraste/administração & dosagem , Feminino , Gadolínio DTPA/administração & dosagem , Humanos , Imageamento Tridimensional , Fígado/irrigação sanguínea , Espectroscopia de Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Movimento (Física) , Compostos Organometálicos/administração & dosagem , Estudos Retrospectivos , Fatores de Risco
17.
Abdom Radiol (NY) ; 45(9): 2779-2785, 2020 09.
Artigo em Inglês | MEDLINE | ID: mdl-32430511

RESUMO

OBJECTIVES: Although it is important to quantify the degree of fatty degeneration of the pancreas, it is difficult to make such a quantification using conventional computed tomography (CT). The present study evaluated the feasibility of pancreatic fat quantification by dual-energy CT (DECT) compared with T2*-corrected six-point Dixon magnetic resonance imaging (MRI). MATERIALS AND METHODS: Twenty-eight patients who underwent both DECT (100 and 150 kVp) and Dixon MRI without the use of contrast agents were analyzed. The region of interest (ROI) was placed at the head and body/tail of the pancreas on fat volume fraction (FVF) maps generated using the multi-material decomposition (MMD) algorithm on DECT. The FVF (%) of pancreatic parenchyma measured by DECT (CT-FVF) was compared with that measured on FVF maps calculated using Dixon MRI (MR-FVF) using the Spearman rank correlation coefficient. RESULTS: The median CT-FVF (%) values of the head and body/tail of the pancreas on DECT were 14.2% (range 0.1-81.2%) and 9.4% (range 0-40.8%), respectively. The median MR-FVF (%) values of the head and body/tail of the pancreas on Dixon MRI were 12.2% (range 1.2-80.9%) and 8.1% (range 0.3-43.7%), respectively. CT-FVF (%) measured by DECT showed a significant correlation with the MR-FVF (%) measured by Dixon MRI in the head of the pancreas (ρ = 0.631, P < 0.001) as well as the body/tail of the pancreas (ρ = 0.526, P = 0.004). CONCLUSION: DECT may be useful for quantifying the degree of fatty degeneration of the pancreas.


Assuntos
Pâncreas , Tomografia Computadorizada por Raios X , Algoritmos , Meios de Contraste , Humanos , Imageamento por Ressonância Magnética , Pâncreas/diagnóstico por imagem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...