Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 155
Filtrar
1.
Exp Neurol ; 378: 114843, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38823675

RESUMO

Poststroke neuroinflammation exacerbates disease progression. [11C]PK11195-positron emission tomography (PET) imaging has been used to visualize neuroinflammation; however, its short half-life of 20 min limits its clinical use. [123I]CLINDE has a longer half-life (13h); therefore, [123I]CLINDE-single-photon emission computed tomography (SPECT) imaging is potentially more practical than [11C]PK11195-PET imaging in clinical settings. The objectives of this study were to 1) validate neuroinflammation imaging using [123I]CLINDE and 2) investigate the mechanisms underlying stroke in association with neuroinflammation using multimodal techniques, including magnetic resonance imaging (MRI), gas-PET, and histological analysis, in a rat model of ischemic stroke, that is, permanent middle cerebral artery occlusion (pMCAo). At 6 days post-pMCAo, [123I]CLINDE-SPECT considerably corresponded to the immunohistochemical images stained with the CD68 antibody (a marker for microglia/microphages), comparable to the level observed in [11C]PK11195-PET images. In addition, the [123I]CLINDE-SPECT images corresponded well with autoradiography images. Rats with severe infarcts, as defined by MRI, exhibited marked neuroinflammation in the peri-infarct area and less neuroinflammation in the ischemic core, accompanied by a substantial reduction in the cerebral metabolic rate of oxygen (CMRO2) in 15O-gas-PET. Rats with moderate-to-mild infarcts exhibited neuroinflammation in the ischemic core, where CMRO2 levels were mildly reduced. This study demonstrates that [123I]CLINDE-SPECT imaging is suitable for neuroinflammation imaging and that the distribution of neuroinflammation varies depending on the severity of infarction.


Assuntos
Modelos Animais de Doenças , Tomografia Computadorizada de Emissão de Fóton Único , Animais , Ratos , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Masculino , Ratos Sprague-Dawley , Doenças Neuroinflamatórias/diagnóstico por imagem , Doenças Neuroinflamatórias/patologia , Doenças Neuroinflamatórias/metabolismo , Imageamento por Ressonância Magnética/métodos , Acidente Vascular Cerebral/diagnóstico por imagem , Acidente Vascular Cerebral/patologia , Acidente Vascular Cerebral/metabolismo , Infarto da Artéria Cerebral Média/diagnóstico por imagem , Infarto da Artéria Cerebral Média/patologia , Infarto da Artéria Cerebral Média/metabolismo , Tomografia por Emissão de Pósitrons/métodos , Encéfalo/diagnóstico por imagem , Encéfalo/metabolismo , Encéfalo/patologia
3.
Front Nutr ; 11: 1359330, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38716073

RESUMO

Background: Carotid artery stenosis or occlusion (CASO) is a major cause of vascular cognitive impairment (VCI). There is currently no effective treatment for VCI induced by CASO. Resveratrol, a type of polyphenol, improves cognitive performance in rat CASO models via pleiotropic effects. Furthermore, we previously reported the longevity gene, SIRT1, which can be activated by resveratrol, improves cognitive and cerebral blood flow impairment in mouse CASO models by activating endothelial nitric oxide synthase. However, clinical evidence remains limited. Methods: The REsveratrol for VAscular cognitive impairment investigating cerebral Metabolism and Perfusion (REVAMP) trial is a randomized, double-blind, placebo-controlled trial involving patients with asymptomatic CASO. Each participant will receive either 150 mg/day of resveratrol or a placebo for 35 weeks. The primary objective is to determine whether resveratrol improves cognitive impairment, as assessed using the Alzheimer's disease Assessment Scale-cognitive subscale 13. One of our secondary objectives is to determine whether resveratrol improves cerebral hemodynamic impairment as assessed via 15O-gas positron emission tomography. We will recruit 100 patients (50 per group). Discussion: The REVAMP trial may provide valuable insights into new therapeutic options, as multitarget neuroprotection could potentially improve cognitive function along with enhancements in cerebral hemodynamic status in patients with asymptomatic CASO.Clinical trial registration: The REVAMP trial was prospectively registered in the Japan Registry of Clinical Trials (jRCTs051230013) on April 13, 2023.

4.
J Stroke ; 26(1): 64-74, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38326707

RESUMO

BACKGROUND AND PURPOSE: Carotid artery stenosis or occlusion (CASO) is a causative disease of vascular cognitive impairment (VCI) attributed to cerebral hypoperfusion, even without the development of symptomatic ischemic stroke. Preclinically, resveratrol has been demonstrated to play an important role in improving cognitive function in rodent CASO models. This study investigated the association between long-term resveratrol intake and improvements in cognitive and cerebral hemodynamic impairments in patients with CASO. METHODS: A retrospective cohort study was conducted on patients with asymptomatic carotid artery stenosis of ≥50% or occlusion who underwent 15O-gas positron emission tomography (15O-gas PET) and neuropsychological tests such as Montreal Cognitive Assessment (MoCA) and Alzheimer's Disease Assessment Scale-Cognitive Subscale 13 (ADAS-Cog) twice between July 2020 and March 2022 allowing >125-day interval. Patients were administered 30 mg/day resveratrol after the first 15O-gas PET and neuropsychological tests were compared with those who were not. RESULTS: A total of 79 patients were enrolled in this study; 36 received resveratrol and 43 did not. Over a mean follow-up of 221.2 and 244.8 days, long-term resveratrol treatment significantly improved visuospatial/executive function (P=0.020) in MoCA, and memory domain (P=0.007) and total score (P=0.019) in ADAS-Cog. Cerebral blood flow demonstrated improvement in the right frontal lobe (P=0.027), left lenticular nucleus (P=0.009), right thalamus (P=0.035), and left thalamus (P=0.010) on 15O-gas PET. No adverse events were reported. CONCLUSION: Long-term daily intake of oral resveratrol may prevent or treat VCI by improving the cerebral blood flow in asymptomatic patients with CASO.

5.
J Clin Endocrinol Metab ; 109(4): 1033-1040, 2024 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-37955868

RESUMO

CONTEXT: Studies on human renal metabolism are scanty. Nowadays, functional imaging allows the characterization of renal metabolism in a noninvasive manner. We have recently demonstrated that fluorodeoxyglucose F18 (18F FDG) positron emission tomography can be used to analyze renal glucose uptake (GU) rates, and that the renal cortex is an insulin-sensitive tissue. OBJECTIVE: To confirm that renal GU is decreased in people with obesity and to test whether circulating metabolites are related to renal GU. DESIGN, SETTING AND PARTICIPANTS: Eighteen people with obesity and 18 nonobese controls were studied with [18F]FDG positron emission tomography during insulin clamp. Renal scans were obtained ∼60 minutes after [18F]FDG injection. Renal GU was measured using fractional uptake rate and after correcting for residual intratubular [18F]FDG. Circulating metabolites were measured using high-throughput proton nuclear magnetic resonance metabolomics. RESULTS: Cortical GU was higher in healthy nonobese controls compared with people with obesity (4.7 [3.4-5.6] vs 3.1 [2.2-4.3], P = .004, respectively), and it associated positively with the degree of insulin sensitivity (M value) (r = 0.42, P = .01). Moreover, cortical GU was inversely associated with circulating ß-OH-butyrate (r = -0.58, P = .009), acetoacetate (r = -0.48, P = .008), citrate (r = -0.44, P = .01), and free fatty acids (r = -0.68, P < .0001), even when accounting for the M value. On the contrary, medullary GU was not associated with any clinical parameters. CONCLUSION: These data confirm differences in renal cortical GU between people with obesity and healthy nonobese controls. Moreover, the negative correlations between renal cortex GU and free fatty acids, ketone bodies, and citrate are suggestive of substrate competition in the renal cortex.


Assuntos
Resistência à Insulina , Humanos , Ácidos Graxos não Esterificados , Fluordesoxiglucose F18 , Glucose/metabolismo , Insulina , Tomografia por Emissão de Pósitrons , Obesidade , Citratos , Compostos Radiofarmacêuticos
6.
J Cereb Blood Flow Metab ; 44(6): 1024-1038, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38112197

RESUMO

Perinatal hypoxic-ischaemic encephalopathy (HIE) is the leading cause of irreversible brain damage resulting in serious neurological dysfunction among neonates. We evaluated the feasibility of positron emission tomography (PET) methodology with 15O-labelled gases without intravenous or tracheal cannulation for assessing temporal changes in cerebral blood flow (CBF) and cerebral metabolic rate for oxygen (CMRO2) in a neonatal HIE rat model. Sequential PET scans with spontaneous inhalation of 15O-gases mixed with isoflurane were performed over 14 days after the hypoxic-ischaemic insult in HIE pups and age-matched controls. CBF and CMRO2 in the injured hemispheres of HIE pups remarkably decreased 2 days after the insult, gradually recovering over 14 days in line with their increase found in healthy controls according to their natural maturation process. The magnitude of hemispheric tissue loss histologically measured after the last PET scan was significantly correlated with the decreases in CBF and CMRO2.This fully non-invasive imaging strategy may be useful for monitoring damage progression in neonatal HIE and for evaluating potential therapeutic outcomes.


Assuntos
Animais Recém-Nascidos , Circulação Cerebrovascular , Modelos Animais de Doenças , Hipóxia-Isquemia Encefálica , Radioisótopos de Oxigênio , Tomografia por Emissão de Pósitrons , Animais , Tomografia por Emissão de Pósitrons/métodos , Hipóxia-Isquemia Encefálica/metabolismo , Hipóxia-Isquemia Encefálica/diagnóstico por imagem , Ratos , Encéfalo/metabolismo , Encéfalo/diagnóstico por imagem , Oxigênio/metabolismo , Ratos Sprague-Dawley
7.
J Nucl Med ; 64(Suppl 2): 11S-19S, 2023 11.
Artigo em Inglês | MEDLINE | ID: mdl-37918848

RESUMO

Recently, PET systems with a long axial field of view have become the current state of the art. Total-body PET scanners enable unique possibilities for scientific research and clinical diagnostics, but this new technology also raises numerous challenges. A key advantage of total-body imaging is that having all the organs in the field of view allows studying biologic interaction of all organs simultaneously. One of the new, promising imaging techniques is total-body quantitative perfusion imaging. Currently, 15O-labeled water provides a feasible option for quantitation of tissue perfusion at the total-body level. This review summarizes the status of the methodology and the analysis and provides examples of preliminary findings on applications of quantitative parametric perfusion images for research and clinical work. We also describe the opportunities and challenges arising from moving from single-organ studies to modeling of a multisystem approach with total-body PET, and we discuss future directions for total-body imaging.


Assuntos
Imagem de Perfusão , Água , Imagem de Perfusão/métodos , Tomografia por Emissão de Pósitrons/métodos
8.
Cardiovasc Res ; 119(4): 1008-1020, 2023 05 02.
Artigo em Inglês | MEDLINE | ID: mdl-36266737

RESUMO

AIMS: The liver is the major organ shown to remove oxidized low-density lipoprotein (oxLDL) from the circulation. Given increased evidence that thermogenic adipose tissue has anti-effects, we used 123I-labelled oxLDL as a tracer to reveal oxLDL accumulation in the brown adipose tissue (BAT) of mice. We also explored the mechanisms of oxLDL accumulation in BAT. METHODS AND RESULTS: We used high-resolution nanoSPECT/CT to investigate the tissue distribution of 123I-oxLDL and 123I-LDL (control) following intravenous injection into conscious mice. 123I-oxLDL distribution was discovered in BAT at an intensity equivalent to that in the liver, whereas 123I-LDL was detected mostly in the liver. Consistent with the function of BAT related to sympathetic nerve activity, administering anaesthesia in mice almost completely eliminated the accumulation of 123I-oxLDL in BAT, and this effect was reversed by administering ß3-agonist. Furthermore, exposing mice to cold stress at 4°C enhanced 123I-oxLDL accumulation in BAT. Because in 123I-oxLDL, the protein of oxLDL was labelled, we performed additional experiments with DiI-oxLDL in which the lipid phase of oxLDL was fluorescently labelled and observed similar results, suggesting that the whole oxLDL particle was taken up by BAT. To identify the receptor responsible for oxLDL uptake in BAT, we analysed the expression of known oxLDL receptors (e.g. SR-A, CD36, and LOX-1) in cultured brown adipocyte cell line and primary brown adipocytes and found that CD36 was the major receptor expressed. Treatment of cells with CD36 siRNA or CD36 neutralizing antibody significantly inhibited DiI-oxLDL uptake. Finally, CD36 deletion in mice abolished the accumulation of 123I-oxLDL and DiI-oxLDL in BAT, indicating that CD36 is the major receptor for oxLDL in BAT. CONCLUSION: We show novel evidence for the CD36-mediated accumulation of oxLDL in BAT, suggesting that BAT may exert its anti-atherogenic effects by removing atherogenic LDL from the circulation.


Assuntos
Tecido Adiposo Marrom , Lipoproteínas LDL , Animais , Camundongos , Tecido Adiposo Marrom/metabolismo , Lipoproteínas LDL/metabolismo , Antígenos CD36/metabolismo
9.
Metabolism ; 141: 155382, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36565992

RESUMO

BACKGROUND/PURPOSE: Studying renal glucose metabolism non-invasively in humans is an unmet need. Positron emission tomography (PET) is the current gold standard for measuring regional tissue glucose uptake rates, but the most widely used glucose analog ([18F]FDG) is not a good substrate for sodium-glucose cotransporters (SGLTs). As a consequence, [18F]FDG spills over into the urine and [18F]FDG-PET considerably underestimates published rates of whole renal glucose uptake obtained using the arterial-venous difference technique. Our aim was to assess whether [18F]FDG-PET can be used in the study of renal glucose metabolism in humans. METHODS: We measured individual [18F]FDG radioactivity in the urine and estimated intraluminal [18F]FDG radioactivity concentration; these values were used to correct renal [18F]FDG-PET data acquired ∼90 min from tracer injection under fasting conditions and during an insulin clamp in 9 lean and 16 obese subjects. RESULTS: We found that the corrected glucose uptake is consistently higher in the medulla than cortex and that both cortical and medullary glucose uptake are higher in lean than obese participants under both fasting and insulinized conditions. Moreover, cortical but not medullary glucose uptake is increased from the fasting to the insulinized condition. CONCLUSION: The data show for the first time that [18F]FDG-PET can still provide relevant physiological information on regional renal glucose uptake on the condition that [18F]FDG uptake is corrected for tubular radioactivity.


Assuntos
Fluordesoxiglucose F18 , Tomografia Computadorizada por Raios X , Humanos , Tomografia por Emissão de Pósitrons/métodos , Glucose/metabolismo , Obesidade , Compostos Radiofarmacêuticos
10.
Mol Imaging Biol ; 24(4): 641-650, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-35303205

RESUMO

PURPOSE: Recent studies have linked activated spinal glia to neuropathic pain. Here, using a positron emission tomography (PET) scanner with high spatial resolution and sensitivity, we evaluated the feasibility and sensitivity of N,N-diethyl-2-(2-(4-([18F]fluoro)phenyl)-5,7-dimethylpyrazolo[1,5-a] pyrimidin-3-yl)acetamide ([18F]F-DPA) imaging for detecting spinal cord microglial activation after partial sciatic nerve ligation (PSNL) in rats. PROCEDURES: Neuropathic pain was induced in rats (n = 20) by PSNL, and pain sensation tests were conducted before surgery and 3 and 7 days post-injury. On day 7, in vivo PET imaging and ex vivo autoradiography were performed using [18F]F-DPA or [11C]PK11195. Ex vivo biodistribution and PET imaging of the removed spinal cord were carried out with [18F]F-DPA. Sham-operated and PK11195-pretreated animals were also examined. RESULTS: Mechanical allodynia was confirmed in the PSNL rats from day 3 through day 7. Ex vivo autoradiography showed a higher lesion-to-background uptake with [18F]F-DPA compared with [11C]PK11195. Ex vivo PET imaging of the removed spinal cord showed [18F]F-DPA accumulation in the inflammation site, which was immunohistochemically confirmed to coincide with microglia activation. Pretreatment with PK11195 eliminated the uptake. The SUV values of in vivo [18F]F-DPA and [11C]PK11195 PET were not significantly increased in the lesion compared with the reference region, and were fivefold higher than the values obtained from the ex vivo data. Ex vivo biodistribution revealed a twofold higher [18F]F-DPA uptake in the vertebral body compared to that seen in the bone from the skull. CONCLUSIONS: [18F]F-DPA aided visualization of the spinal cord inflammation site in PSNL rats on ex vivo autoradiography and was superior to [11C]PK11195. In vivo [18F]F-DPA PET did not allow for visualization of tracer accumulation even using a high-spatial-resolution PET scanner. The main reason for this result was due to insufficient SUVs in the spinal cord region as compared with the background noise, in addition to a spillover from the vertebral body.


Assuntos
Microglia , Neuralgia , Animais , Radioisótopos de Flúor , Microglia/patologia , Neuralgia/diagnóstico por imagem , Neuralgia/patologia , Tomografia por Emissão de Pósitrons/métodos , Pirazóis , Pirimidinas , Ratos , Medula Espinal/diagnóstico por imagem , Distribuição Tecidual
11.
J Nucl Cardiol ; 29(4): 1964-1972, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-33948894

RESUMO

In Myocardial Perfusion Imaging (MPI) with Positron Emission Tomography/Computed Tomography (PET/CT) systems, accurate quantification is essential. We assessed flow quantification accuracy over various injected activities using a flow phantom. METHODS: The study was performed on the digital 4-ring Discovery MI (DMI-20) and analog Discovery 690 (D690) PET/CT systems, using 325-1257 MBq of [15O]H2O. PET performance and flow quantification accuracy were assessed in terms of count-rates, dead-time factors (DTF), scatter fractions (SF), time-activity curves (TACs), areas-under-the-curves (AUCs) and flow values. RESULTS: On DMI-20, prompts of 12.8 Mcps, DTF of 2.06 and SF of 46.1% were measured with 1257 MBq of activity. On the D690, prompts of 6.85 Mcps, DTF of 1.57 and SF of 32.5% were measured with 1230 MBq of activity. AUC values were linear over all activities. Mean wash-in flow error was - 9% for both systems whereas wash-out flow error was - 5% and - 6% for DMI-20 and D690. With the highest activity, wash-out flow error was - 12% and - 7% for the DMI-20 and D690. CONCLUSION: DMI-20 and D690 preserved accurate flow quantification over all injected activities, with maximum error of - 12%. In the future, flow quantification accuracy over the activities and count-rates evaluated in this study should be assessed.


Assuntos
Imagem de Perfusão do Miocárdio , Humanos , Imagem de Perfusão do Miocárdio/métodos , Imagens de Fantasmas , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Tomografia por Emissão de Pósitrons/métodos
13.
Eur J Appl Physiol ; 122(1): 81-90, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-34564756

RESUMO

PURPOSE: While brown adipose tissue (BAT) activity is known to be associated with both muscle and adipose tissue volumes, the association between BAT and muscle composition remains unclear, especially in adults. Therefore, the present study aimed to examine the association between BAT parameters (glucose uptake and fat-fraction) and muscle volumes and intramuscular adipose tissue contents among healthy young and middle-aged men. METHODS: BAT glucose uptake was determined using positron emission tomography with [18F]-2-deoxy-2-fluoro-D-glucose (18F-FDG) during cold exposure in 19 young and middle-aged men (36.3 ± 10.7 years). The fat-fraction of BAT was determined from volumes of interest set in cervical and supraclavicular adipose tissue depots using signal fat-fraction maps via magnetic resonance imaging (MRI). Muscle volumes and intramuscular adipose tissue contents of m. tibialis anterior and m. multifidus lumborum were measured using MRI. RESULTS: The fat-fraction of BAT was significantly associated with intramuscular adipose tissue content in m. tibialis anterior (n = 13, rs = 0.691, P = 0.009). A similar trend was also observed in m. multifidus lumborum (n = 19, rs = 0.454, P = 0.051). However, BAT glucose uptake was not associated with intramuscular adipose tissue contents in both muscles, nor were muscle volumes associated with the BAT glucose uptake and fat-fraction. CONCLUSION: The fat-fraction of BAT increases with skeletal muscle adiposity, especially in the lower leg, among healthy young and middle-aged men.


Assuntos
Tecido Adiposo Marrom/metabolismo , Adiposidade , Músculo Esquelético/metabolismo , Tecido Adiposo Marrom/diagnóstico por imagem , Adulto , Fluordesoxiglucose F18 , Glucose/metabolismo , Voluntários Saudáveis , Humanos , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Músculo Esquelético/diagnóstico por imagem , Tomografia por Emissão de Pósitrons , Compostos Radiofarmacêuticos
14.
Kaku Igaku ; 58(1): 19-32, 2021.
Artigo em Japonês | MEDLINE | ID: mdl-33896894

RESUMO

PURPOSE: We developed and validated the accuracy of a method to calculate the arterial input function (AIF) from PET images only, without the need for the arterial blood sampling, in the absolute quantitation of functional parametric values in 15O- gas PET examinations. METHODS: We extended the method reported by Iguchi et al. (2013) to derive the arterial input function, thus absolute quantitative functional parametric images of cerebral perfusion and oxygen metabolism by a reference tissue approach. We compared shapes of the AIF and reproducibility of the absolute functional values. Existing test data that were carried out with the continuous arterial blood sampling were used for this study. RESULTS: The estimated AIF shapes agreed well with those estimated from the continuous arterial blood sampling. The error range of the absolute quantitative values was approximately ±20%, with a fairly well reproducibility in the relative values being less than 3%. CONCLUSION: The AIFs by this method were reproducible. Although the absolute quantitative values varied depending on the assumed functional values in the reference region in individual cases, the relative images showed fairly good agreement with the results from the standard technique that employed the arterial blood sampling. The present technique may provide significant contribution to clinical examination.


Assuntos
Algoritmos , Artérias , Artérias/diagnóstico por imagem , Reprodutibilidade dos Testes
15.
J Nucl Med ; 2021 Mar 19.
Artigo em Inglês | MEDLINE | ID: mdl-33741647

RESUMO

The gold standard for imaging the cerebral metabolic rate of oxygen (CMRO2) is positron emission tomography (PET); however, it is an invasive and complex procedure that also requires correction for recirculating 15O-H2O and the blood-borne activity. We propose a noninvasive reference-based hybrid PET/magnetic resonance imaging (MRI) method that uses functional MRI techniques to calibrate 15O-O2-PET data. Here, PET/MR imaging of oxidative metabolism (PMROx) was validated in an animal model by comparison to PET-alone measurements. Additionally, we investigated if the MRI-perfusion technique arterial spin labelling (ASL) could be used to further simplify PMROx by replacing 15O-H2O-PET, and if the PMROx was sensitive to anesthetics-induced changes in metabolism. Methods: 15O-H2O and 15O-O2 PET data were acquired in a hybrid PET/MR scanner (3 T Siemens Biograph mMR), together with simultaneous functional MRI (OxFlow and ASL), from juvenile pigs (n = 9). Animals were anesthetized with 3% isoflurane and 6 mL/kg/h propofol for the validation experiments and arterial sampling was performed for PET-alone measurements. PMROx estimates were obtained using whole-brain (WB) CMRO2 from OxFlow and local cerebral blood flow (CBF) from either noninvasive 15O-H2O-PET or ASL (PMROxASL). Changes in metabolism were investigated by increasing the propofol infusion to 20 mL/kg/h. Results: Good agreement and correlation were observed between regional CMRO2 measurements from PMROx and PET-alone. No significant differences were found between OxFlow and PET-only measurements of WB oxygen extraction fraction (0.30 ± 0.09 and 0.31 ± 0.09) and CBF (54.1 ± 16.7 and 56.6 ± 21.0 mL/100 g/min), or between PMROx and PET-only CMRO2 estimates (1.89 ± 0.16 and 1.81 ± 0.10 mLO2/100 g/min). Moreover, PMROx and PMROxASL were sensitive to propofol-induced reduction in CMRO2 Conclusion: This study provides initial validation of a noninvasive PET/MRI technique that circumvents many of the complexities of PET CMRO2 imaging. PMROx does not require arterial sampling and has the potential to reduce PET imaging to 15O-O2 only; however, future validation involving human participants are required.

16.
Phys Med Biol ; 66(6): 065009, 2021 03 04.
Artigo em Inglês | MEDLINE | ID: mdl-33596555

RESUMO

Positron emission tomography (PET) remains the gold standard for quantitative imaging of the cerebral metabolic rate of oxygen (CMRO2); however, it is an invasive and complex procedure that requires accounting for recirculating [15O]H2O (RW) and the cerebral blood volume (CBV). This study presents a non-invasive reference-based technique for imaging CMRO2 that was developed for PET/magnetic resonance imaging (MRI) with the goal of simplifying the PET procedure while maintaining its ability to quantify metabolism. The approach is to use whole-brain (WB) measurements of oxygen extraction fraction (OEF) and cerebral blood flow (CBF) to calibrate [15O]O2-PET data, thereby avoiding the need for invasive arterial sampling. Here we present the theoretical framework, along with error analyses, sensitivity to PET noise and inaccuracies in input parameters, and initial assessment on PET data acquired from healthy participants. Simulations showed that neglecting RW and CBV corrections caused errors in CMRO2 of less than ±10% for changes in regional OEF of ±25%. These predictions were supported by applying the reference-based approach to PET data, which resulted in remarkably similar CMRO2 images to those generated by analyzing the same data using a modeling approach that incorporated the arterial input functions and corrected for CBV contributions. Significant correlations were observed between regional CMRO2 values from the two techniques (slope = 1.00 ± 0.04, R 2 > 0.98) with no significant differences found for integration times of 3 and 5 min. In summary, results demonstrate the feasibility of producing quantitative CMRO2 images by PET/MRI without the need for invasive blood sampling.


Assuntos
Encéfalo/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Imagem Multimodal/métodos , Consumo de Oxigênio , Tomografia por Emissão de Pósitrons/métodos , Adulto , Algoritmos , Encéfalo/metabolismo , Circulação Cerebrovascular , Humanos , Imageamento por Ressonância Magnética/normas , Imagem Multimodal/normas , Tomografia por Emissão de Pósitrons/normas , Padrões de Referência
17.
J Cereb Blood Flow Metab ; 41(7): 1707-1720, 2021 07.
Artigo em Inglês | MEDLINE | ID: mdl-33222596

RESUMO

Perinatal hypoxic ischemic encephalopathy (HIE) results in serious neurological dysfunction and mortality. Clinical trials of multilineage-differentiating stress enduring cells (Muse cells) have commenced in stroke using intravenous delivery of donor-derived Muse cells. Here, we investigated the therapeutic effects of human Muse cells in an HIE model. Seven-day-old rats underwent ligation of the left carotid artery then were exposed to 8% oxygen for 60 min, and 72 hours later intravenously transplanted with 1 × 104 of human-Muse and -non-Muse cells, collected from bone marrow-mesenchymal stem cells as stage-specific embryonic antigen-3 (SSEA-3)+ and -, respectively, or saline (vehicle) without immunosuppression. Human-specific probe revealed Muse cells distributed mainly to the injured brain at 2 and 4 weeks, and expressed neuronal and glial markers until 6 months. In contrast, non-Muse cells lodged in the lung at 2 weeks, but undetectable by 4 weeks. Magnetic resonance spectroscopy and positron emission tomography demonstrated that Muse cells dampened excitotoxic brain glutamatergic metabolites and suppressed microglial activation. Muse cell-treated group exhibited significant improvements in motor and cognitive functions at 4 weeks and 5 months. Intravenously transplanted Muse cells afforded functional benefits in experimental HIE possibly via regulation of glutamate metabolism and reduction of microglial activation.


Assuntos
Diferenciação Celular , Glutamatos/metabolismo , Hipóxia-Isquemia Encefálica/terapia , Transplante de Células-Tronco Mesenquimais/métodos , Células-Tronco Mesenquimais/citologia , Microglia/fisiologia , Animais , Animais Recém-Nascidos , Humanos , Hipóxia-Isquemia Encefálica/etiologia , Hipóxia-Isquemia Encefálica/metabolismo , Hipóxia-Isquemia Encefálica/patologia , Injeções Intravenosas , Microglia/citologia , Ratos , Ratos Wistar
18.
J Nucl Med ; 61(12): 1701-1707, 2020 12.
Artigo em Inglês | MEDLINE | ID: mdl-32948678

RESUMO

PET with 18F-FDG has been increasingly applied, predominantly in the research setting, to study drug effects and pulmonary biology and to monitor disease progression and treatment outcomes in lung diseases that interfere with gas exchange through alterations of the pulmonary parenchyma, airways, or vasculature. To date, however, there are no widely accepted standard acquisition protocols or imaging data analysis methods for pulmonary 18F-FDG PET/CT in these diseases, resulting in disparate approaches. Hence, comparison of data across the literature is challenging. To help harmonize the acquisition and analysis and promote reproducibility, we collated details of acquisition protocols and analysis methods from 7 PET centers. From this information and our discussions, we reached the consensus recommendations given here on patient preparation, choice of dynamic versus static imaging, image reconstruction, and image analysis reporting.


Assuntos
Consenso , Fluordesoxiglucose F18 , Pneumopatias/diagnóstico por imagem , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Guias de Prática Clínica como Assunto , Fluordesoxiglucose F18/administração & dosagem , Humanos , Processamento de Imagem Assistida por Computador , Injeções , Pneumopatias/fisiopatologia , Posicionamento do Paciente , Respiração
19.
BMC Nephrol ; 20(1): 437, 2019 11 27.
Artigo em Inglês | MEDLINE | ID: mdl-31775670

RESUMO

BACKGROUND: Despite improvement in short-term outcome of kidney transplants, the long-term survival of kidney transplants has not changed over past decades. Kidney biopsy is the gold standard of transplant pathology but it's invasive. Quantification of transplant blood flow could provide a novel non-invasive method to evaluate transplant pathology. The aim of this retrospective cross-sectional pilot study was to evaluate positron emission tomography (PET) as a method to measure kidney transplant perfusion and find out if there is correlation between transplant perfusion and histopathology. METHODS: Renal cortical perfusion of 19 kidney transplantation patients [average time from transplantation 33 (17-54) months; eGFR 55 (47-69) ml/min] and 10 healthy controls were studied by [15 O]H2O PET. Perfusion and Doppler resistance index (RI) of transplants were compared with histology of one-year protocol transplant biopsy. RESULTS: Renal cortical perfusion of healthy control subjects and transplant patients were 2.7 (2.4-4.0) ml min- 1 g- 1 and 2.2 (2.0-3.0) ml min- 1 g- 1, respectively (p = 0.1). Renal vascular resistance (RVR) of the patients was 47.0 (36.7-51.4) mmHg mL- 1min- 1g- 1 and that of the healthy 32.4 (24.6-39.6) mmHg mL- 1min-1g-1 (p = 0.01). There was a statistically significant correlation between Doppler RI and perfusion of transplants (r = - 0.51, p = 0.026). Transplant Doppler RI of the group of mild fibrotic changes [0.73 (0.70-0.76)] and the group of no fibrotic changes [0.66 (0.61-0.72)] differed statistically significantly (p = 0.03). No statistically significant correlation was found between cortical perfusion and fibrosis of transplants (p = 0.56). CONCLUSIONS: [15 O]H2O PET showed its capability as a method in measuring perfusion of kidney transplants. RVR of transplant patients with stage 2-3 chronic kidney disease was higher than that of the healthy, although kidney perfusion values didn't differ between the groups. Doppler based RI correlated with perfusion and fibrosis of transplants.


Assuntos
Falência Renal Crônica/cirurgia , Transplante de Rim/efeitos adversos , Imagem de Perfusão/métodos , Tomografia por Emissão de Pósitrons/métodos , Circulação Renal , Transplantes , Resistência Vascular , Biópsia/métodos , Correlação de Dados , Estudos Transversais , Feminino , Humanos , Testes de Função Renal/métodos , Transplante de Rim/métodos , Efeitos Adversos de Longa Duração/diagnóstico , Efeitos Adversos de Longa Duração/fisiopatologia , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Transplantes/irrigação sanguínea , Transplantes/diagnóstico por imagem , Transplantes/patologia
20.
Am J Physiol Endocrinol Metab ; 317(5): E871-E878, 2019 11 01.
Artigo em Inglês | MEDLINE | ID: mdl-31550182

RESUMO

Human studies of renal hemodynamics and metabolism in obesity are insufficient. We hypothesized that renal perfusion and renal free fatty acid (FFA) uptake are higher in subjects with morbid obesity compared with lean subjects and that they both decrease after bariatric surgery. Cortical and medullary hemodynamics and metabolism were measured in 23 morbidly obese women and 15 age- and sex-matched nonobese controls by PET scanning of [15O]-H2O (perfusion) and 14(R,S)-[18F]fluoro-6-thia-heptadecanoate (FFA uptake). Kidney volume and radiodensity were measured by computed tomography, cardiac output by MRI. Obese subjects were re-studied 6 mo after bariatric surgery. Obese subjects had higher renal volume but lower radiodensity, suggesting accumulation of water and/or lipid. Both cardiac output and estimated glomerular filtration rate (eGFR) were increased by ~25% in the obese. Total renal blood flow was higher in the obese [885 (317) (expressed as median and interquartile range) vs. 749 (300) (expressed as means and SD) ml/min of controls, P = 0.049]. In both groups, regional blood perfusion was higher in the cortex than medulla; in either region, FFA uptake was ~50% higher in the obese as a consequence of higher circulating FFA levels. Following weight loss (26 ± 8 kg), total renal blood flow was reduced (P = 0.006). Renal volume, eGFR, cortical and medullary FFA uptake were decreased but not fully normalized. Obesity is associated with renal structural, hemodynamic, and metabolic changes. Six months after bariatric surgery, the hemodynamic changes are reversed and the structural changes are improved. On the contrary, renal FFA uptake remains increased, driven by high substrate availability.


Assuntos
Ácidos Graxos/metabolismo , Rim/metabolismo , Obesidade Mórbida/metabolismo , Obesidade Mórbida/fisiopatologia , Circulação Renal , Redução de Peso , Adulto , Cirurgia Bariátrica , Feminino , Taxa de Filtração Glomerular , Hemodinâmica , Humanos , Rim/diagnóstico por imagem , Córtex Renal/irrigação sanguínea , Córtex Renal/diagnóstico por imagem , Córtex Renal/metabolismo , Medula Renal/irrigação sanguínea , Medula Renal/diagnóstico por imagem , Medula Renal/metabolismo , Imageamento por Ressonância Magnética , Pessoa de Meia-Idade , Obesidade Mórbida/cirurgia , Tomografia Computadorizada por Raios X
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...