Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Materials (Basel) ; 17(13)2024 Jul 02.
Artigo em Inglês | MEDLINE | ID: mdl-38998342

RESUMO

In the present investigation, aluminum metal matrix composites (AMMs) reinforced with aluminum nitride (AlN) nanoparticulates at different volumetric ratios of (0, 0.5, 1, 1.5, and 2 vol.%) were manufactured via a microwave-assisted powder metallurgy technique. The morphological, physical, mechanical, and electrochemical properties of the produced billets were examined to reflect the impact of the successive addition of AlN into the aluminum (Al) matrix. The morphological analysis revealed the high crystalline patterns of the formation of the Al-AlN composites. The microstructural analysis confirmed the presence of the elemental constituents of Al and AlN particles in the fabricated composites, showing an enhanced degree of agglomeration in conjunction with the additional amount of AlN. Positive behavior exhibited by the micro- and nanohardness was noticeable in the Al-AlN composites, especially at the ultimate concentration of AlN in the Al matrix of a 2 vol.%, where it reached 669.4 ± 28.1 MPa and 659.1 ± 11 MPa compared to the pure Al metal at 441.2 ± 20 MPa and 437.5 ± 11 MPa, respectively. A declining trend in the compressive strength was recorded in the reinforced Al samples. The corrosion resistance of the AlN-reinforced Al metal matrix was estimated at 3.5 wt.% NaCl using electrochemical impedance spectroscopy and potentiodynamic polarization. The results reveal that the inclusion of 2.0 vol.%AlN led to the lowest corrosion rate.

2.
Chemosphere ; 346: 140410, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37898467

RESUMO

Enhancing the solar-physical conversion efficacy ability of the nanomaterials is an essential for real-time implementation. We report the enhanced solar-physical efficiency of the BiFeO3 nanospheres via Gd3+ doping and Au nanoparticles decoration. Initially, we have obtained the Bi1-xGdxFeO3 nanospheres were attained via a simple solvothermal technique and then citrate reduction of Au was conducted. Obtained perovskite BiFeO systems were studied for the Gd3+ doping, crystalline phase and elemental purity using the XRD and XPS techniques. Transmission electron microscope had revealed the ∼400 nm sized BiFeO3 nanospheres. Optical absorption spectrum revealed the enhanced visible photon absorption occurring in BiFeO3 for both Gd3+ doping and Au decoration. The bandgap values of pristine, 1%, 3% and 5% Gd3+ doped in BiFeO3 are 2.2 eV, 2.19 eV, 2.17 eV and 2.12 eV, respectively. Conducted photoluminescence revealed the dual electron trapping occurring in BiFeO3 via Gd3+ ions and Au nanoparticles. LED light assisted 72% of piezo-photocatalytic degradation efficiency of Tetracycline is achieved with Bi0 95Fe0 05O3/Au, whereas the photo catalytic is only 65% and piezo catalytic efficiency is 58%. In recyclable studies the Bi0.95Gd0.05FeO3/Au had shown the consistent piezo-photocatalytic efficiency for 3 reaction cycles. Further, fabricated DSSC studies revealed that near 30 % enhanced solar photovoltaic efficiency for Bi0 95Fe0 05O3/Au (η = 6.5%) solar cells on par to the pristine BiFeO3 (η = 5.02%).


Assuntos
Nanopartículas Metálicas , Nanosferas , Ouro , Compostos de Cálcio
3.
Materials (Basel) ; 16(17)2023 Aug 30.
Artigo em Inglês | MEDLINE | ID: mdl-37687652

RESUMO

An understanding of the biomechanical characteristics and configuration of flexible and locked plating in order to provide balance stability and flexibility of implant fixation will help to construct and promote fast bone healing. The relationship between applied loading and implantation configuration for best bone healing is still under debate. This study aims to investigate the relationship between implant strength, working length, and interfragmentary strain (εIFM) on implant stability for femoral midshaft transverse fractures. The transverse fracture was fixed with a fragment locking compression plate (LCP) system. Finite element analysis was performed and subsequently characterised based on compression loading (600 N up to 900 N) and screw designs (conventional and locking) with different penetration depths (unicortical and bicortical). Strain theory was used to evaluate the stability of the model. The correlation of screw configuration with screw type shows a unicortical depth for both types (p < 0.01) for 700 N and 800 N loads and (p < 0.05) for configurations 134 and 124. Interfragmentary strain affected only the 600 N load (p < 0.01) for the bicortical conventional type (group BC), and the screw configurations that were influenced were 1234 and 123 (p < 0.05). The low steepness of the slope indicates the least εIFM for the corresponding biomechanical characteristic in good-quality stability. A strain value of ≤2% promotes callus formation and is classified as absolute stability, which is the minimum required value for the induction of callus and the maximum value that allows bony bridging. The outcomes have provided the correlation of screw configuration in femoral midshaft transverse fracture implantation which is important to promote essential primary stability.

4.
Materials (Basel) ; 16(13)2023 Jun 21.
Artigo em Inglês | MEDLINE | ID: mdl-37444827

RESUMO

Studies on paediatric spines commonly use human adult or immature porcine spines as specimens, because it is difficult to obtain actual paediatric specimens. There are quite obvious differences, such as geometry, size, bone morphology, and orientation of facet joint for these specimens, compared to paediatric spine. Hence, development of synthetic models that can behave similarly to actual paediatric spines, particularly in term of range of motion (ROM), could provide a significant contribution for paediatric spine research. This study aims to develop a synthetic paediatric spine using finite element modelling and evaluate the reliability of the model by comparing it with the experimental data under certain load conditions. The ROM of the paediatric spine was measured using a validated FE model at ±0.5 Nm moment in order to determine the moment required by the synthetic spine to achieve the same ROM. The results showed that the synthetic spine required two moments, ±2 Nm for lateral-bending and axial rotation, and ±3 Nm for flexion-extension, to obtain the paediatric ROM. The synthetic spine was shown to be stiffer in flexion-extension but more flexible in lateral bending than the paediatric FE model, possibly as a result of the intervertebral disc's simplified shape and the disc's weak bonding with the vertebrae. Nevertheless, the synthetic paediatric spine has promising potential in the future as an alternative paediatric spine model for biomechanical investigation of paediatric cases.

5.
Materials (Basel) ; 16(13)2023 Jun 26.
Artigo em Inglês | MEDLINE | ID: mdl-37444917

RESUMO

The powder metallurgy method was used to manufacture three Ti-based alloys: Ti-15%Zr-2%Ta-4%Sn (Ti-Zr-Ta-4Sn), Ti-15%Zr-2%Ta-6%Sn (Ti-Zr-Ta-6Sn), and Ti-15%Zr-2%Ta-8%Sn (Ti-Zr-Ta-8Sn). Electrochemical measurements and surface analyses were used to determine the effect of Sn concentration on the corrosion of these alloys after exposure to a simulated body fluid (SBF) solution for 1 h and 72 h. It was found that the passivation of the alloy surface significantly increased when the Sn content increased from 4% to 6% and then to 8%, which led to a significant reduction in corrosion. The impedance spectra derived from the Nyquist graphs also explained how the addition of Sn significantly improved the alloys' polarization resistances. According to the change in the chronoamperometric current at an applied anodic potential over time, the increase in Sn content within the alloy significantly reduced the currents over time, indicating that the uniform and pitting corrosion were greatly decreased. The formation of an oxide layer (TiO2), which was demonstrated by the surface morphology of the alloys after exposure to SBF solution for 72 h and corrosion at 400 mV (Ag/AgCl) for 60 min, was supported by the profile analysis obtained by an X-ray spectroscopy analyzer. It was clear from all of the findings that the tested alloys have a remarkable improvement in resistance to corrosivity when the Sn content was increased to 8%.

6.
Materials (Basel) ; 15(23)2022 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-36500058

RESUMO

Very often, pure Ti and (α + ß) Ti-6Al-4V alloys have been used commercially for implant applications, but ensuring their chemical, mechanical, and biological biocompatibility is always a serious concern for sustaining the long-term efficacy of implants. Therefore, there has always been a great quest to explore new biomedical alloying systems that can offer substantial beneficial effects in tailoring a balance between the mechanical properties and biocompatibility of implantable medical devices. With a view to the mechanical performance, this study focused on designing a Ti-15Zr-2Ta-xSn (where x = 4, 6, 8) alloying system with high strength and low Young's modulus prepared by a powder metallurgy method. The experimental results showed that mechanical alloying, followed by spark plasma sintering, produced a fully consolidated (α + ß) Ti-Zr-Ta-Sn-based alloy with a fine grain size and a relative density greater than 99%. Nevertheless, the shape, size, and distribution of α-phase precipitations were found to be sensitive to Sn contents. The addition of Sn also increased the α/ß transus temperature of the alloy. For example, as the Sn content was increased from 4 wt.% to 8 wt.%, the ß grains transformed into diverse morphological characteristics, namely, a thin-grain-boundary α phase (αGB), lamellar α colonies, and acicular αs precipitates and very low residual porosity during subsequent cooling after the spark plasma sintering procedure, which is consistent with the relative density results. Among the prepared alloys, Ti-15Zr-2Ta-8Sn exhibited the highest hardness (s340 HV), compressive yield strength (~1056 MPa), and maximum compressive strength (~1470). The formation of intriguing precipitate-matrix interfaces (α/ß) acting as dislocation barriers is proposed to be the main reason for the high strength of the Ti-15Zr-2Ta-8Sn alloy. Finally, based on mechanical and structural properties, it is envisaged that our developed alloys will be promising for indwelling implant applications.

7.
Materials (Basel) ; 15(24)2022 Dec 09.
Artigo em Inglês | MEDLINE | ID: mdl-36556616

RESUMO

Ti-15%Zr alloy and Ti-15%Zr-2%Ta alloy were fabricated to be used in biomedical applications. The corrosion of these two alloys after being immersed in simulated body fluid for 1 h and 72 h was investigated. Different electrochemical methods, including polarization, impedance, and chronoamperometric current with time at 400 mV were employed. Also, the surface morphology and the compositions of its formed film were reported by the use of scanning electron microscope and energy dispersive X-ray. Based on the collected results, the presence of 2%Ta in the Ti-Zr alloy passivated its corrosion by minimizing its corrosion rate. The polarization curves revealed that adding Ta within the alloy increases the corrosion resistance as was confirmed by the impedance spectroscopy and current time data. The change of current versus time proved that the addition of Ta reduces the absolute current even at high anodic potential, 400 mV. The results of both electrochemical and spectroscopic methods indicated that pitting corrosion does not occur for both Ti-Zr and Ti-Zr-Ta alloys, even after their immersion in SBF solutions for 72 h.

8.
Materials (Basel) ; 9(10)2016 Oct 04.
Artigo em Inglês | MEDLINE | ID: mdl-28773939

RESUMO

A new superelastic Ti-23Hf-3Mo-4Sn biomedical alloy displaying a particularly large recovery strain was synthesized and characterized in this study. Its native passive film is very thick (18 nm) and contains very protective TiO2, Ti2O3, HfO2, MoO2, and SnO2 oxides (XPS analysis). This alloy revealed nobler electrochemical behavior, more favorable values of the corrosion parameters and open circuit potentials in simulated body fluid in comparison with commercially pure titanium (CP-Ti) and Ti-6Al-4V alloy taken as reference biomaterials in this study. This is due to the favorable influence of the alloying elements Hf, Sn, Mo, which enhance the protective properties of the native passive film on alloy surface. Impedance spectra showed a passive film with two layers, an inner, capacitive, barrier, dense layer and an outer, less insulating, porous layer that confer both high corrosion resistance and bioactivity to the alloy. In vitro tests were carried out in order to evaluate the response of Human Umbilical Vein Endothelial Cells (HUVECs) to Ti-23Hf-3Mo-4Sn alloy in terms of cell viability, cell proliferation, phenotypic marker expression and nitric oxide release. The results indicate a similar level of cytocompatibility with HUVEC cells cultured on Ti-23Hf-3Mo-4Sn substrate and those cultured on the conventional CP-Ti and Ti-6Al-4V metallic materials.

9.
Mater Sci Eng C Mater Biol Appl ; 48: 11-20, 2015 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-25579891

RESUMO

A new class of Ti-50Zr base biomedical superelastic alloys was developed in this study. The (Ti-Zr)-Mo-Sn alloys exhibited a shape memory effect and superelastic property by adjusting Mo and Sn contents. The (Ti-Zr)-1.5Mo-3Sn alloy revealed the most stable superelasticity among (Ti-Zr)-(1-2)Mo-(2-4)Sn alloys. The superelastic recovery strain showed a strong dependence on heat treatment temperature after cold working in the (Ti-Zr)-1.5Mo-3Sn alloy. The superelastic recovery strain increased as the heat treatment temperature increased although the critical stress for slip decreased. The (Ti-Zr)-1.5Mo-3Sn alloy heat treated at 1073K exhibited excellent superelastic properties with a large recovery strain as large as 7% which is due to the strong {001}ß<110>ß recrystallization texture.


Assuntos
Ligas/química , Molibdênio/química , Estanho/química , Titânio/química , Zircônio/química , Materiais Biocompatíveis/química , Elasticidade , Teste de Materiais , Microscopia Eletrônica de Varredura , Temperatura , Difração de Raios X
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...