Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Europace ; 25(9)2023 08 02.
Artigo em Inglês | MEDLINE | ID: mdl-37748089

RESUMO

AIMS: Left bundle branch area pacing (LBBAP) is a potential alternative to His bundle pacing. This study aimed to investigate the impact of different septal locations of pacing leads on the diversity of QRS morphology during non-selective LBBAP. METHODS AND RESULTS: Non-selective LBBAP and left ventricular septal pacing (LVSP) were achieved in 50 and 21 patients with atrioventricular block, respectively. The electrophysiological properties of LBBAP and their relationship with the lead location were investigated. QRS morphology and axis showed broad variations during LBBAP. Echocardiography demonstrated a widespread distribution of LBBAP leads in the septum. During non-selective LBBAP, the qR-wave in lead V1 indicated that the primary location for pacing lead was the inferior septum (93%). The non-selective LBBAP lead was deployed deeper than the LVSP lead in the inferior septum. The Qr-wave in lead V1 with the inferior axis in aVF suggested pacing lead placement in the anterior septum. The penetration depth of the non-selective LBBAP lead in the anterior septum was significantly shallower than that in the inferior septum (72 ± 11 and 87 ± 8%, respectively). In lead V6, the deep S-wave indicated the time lag between the R-wave peak and the latest ventricular activation in the coronary sinus trunk, with pacemaker leads deployed closer to the left ventricular apex. CONCLUSION: Different QRS morphologies and axes were linked to the location of the non-selective LBBAP lead in the septum. Various lead deployments are feasible for LBBAP, allowing diversity in the conduction system capture in patients with atrioventricular block.


Assuntos
Bloqueio Atrioventricular , Septo Interventricular , Humanos , Bloqueio Atrioventricular/diagnóstico , Bloqueio Atrioventricular/terapia , Septo Interventricular/diagnóstico por imagem , Sistema de Condução Cardíaco , Ventrículos do Coração/diagnóstico por imagem , Doença do Sistema de Condução Cardíaco
2.
Heart Vessels ; 37(1): 110-114, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-34216250

RESUMO

The temporal changes in ambulatory monitoring findings after cryoballoon (CB) ablation of atrial fibrillation (AF) have not been well elucidated. This study aims to compare the details of ambulatory monitoring after CB and radiofrequency catheter (RFC) ablation for AF. Of 724 consecutive AF patients who underwent initial ablation using a CB or RFC, 508 (254 pairs) were selected using propensity score matching. Ambulatory monitoring was performed at 1, 3, 6, 12, 24 and 36 months after the procedure. After 1, 3 and 6 months, the number of total heart beats (THBs) was larger in the CB group than in the RFC group. It gradually decreased and became significantly similar by 12 months after ablation. THBs significantly increased 1, 3, 6 and 12 months after ablation in both the RFC and CB groups and became statistically similar by 24 months after ablation. The atrial premature contraction burden was higher in the RFC group than in the CB group at 3 months after ablation. THB and APC burden after AF ablation were significantly different between the RF and CB groups. THBs returned to statistically similarity by 2 years after ablation in both groups.


Assuntos
Fibrilação Atrial , Complexos Atriais Prematuros , Ablação por Cateter , Veias Pulmonares , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Complexos Atriais Prematuros/diagnóstico , Criocirurgia/efeitos adversos , Frequência Cardíaca , Humanos , Veias Pulmonares/cirurgia , Recidiva , Resultado do Tratamento
3.
Sci Rep ; 11(1): 23591, 2021 12 08.
Artigo em Inglês | MEDLINE | ID: mdl-34880293

RESUMO

The optimal ablation strategy for persistent atrial fibrillation (PsAF) remains to be defined. We sought to compare very long-term outcomes between linear ablation and electrogram (EGM)-guided ablation for PsAF. In a retrospective analysis, long-term arrhythmia-free survival compared between two propensity-score matched cohorts, one with pulmonary vein isolation (PVI) and linear ablation including roof/mitral isthmus line (LINE-group, n = 52) and one with PVI and EGM-guided ablation (EGM-group; n = 52). Overall, 99% of patients underwent successful PVI. Complete block following linear ablation was achieved for 94% of roof lines and 81% of mitral lines (both lines blocked in 75%). AF termination by EGM-guided ablation was accomplished in 40% of patients. Non-PV foci were targeted in 7 (13%) in the LINE-group and 5 (10%) patients in the EGM-group (p = 0.76). During 100 ± 28 months of follow-up, linear ablation was associated with superior arrhythmia-free survival after the initial and last procedure (1.8 ± 0.9 procedures) compared with EGM-group (Logrank test: p = 0.0001 and p = 0.045, respectively). In multivariable analysis, longer AF duration and EGM-guided ablation remained as independent predictors of atrial arrhythmia recurrence. Linear ablation might be a more effective complementary technique to PVI than EGM-guided ablation for PsAF ablation.


Assuntos
Fibrilação Atrial/cirurgia , Ablação por Cateter/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Pontuação de Propensão , Veias Pulmonares/cirurgia , Recidiva , Estudos Retrospectivos , Fatores de Tempo , Resultado do Tratamento
4.
Sci Rep ; 11(1): 6226, 2021 03 18.
Artigo em Inglês | MEDLINE | ID: mdl-33737633

RESUMO

While phrenic nerve palsy (PNP) due to cryoballoon pulmonary vein isolation (PVI) of atrial fibrillation (AF) was transient in most cases, no studies have reported the results of the long-term follow-up of PNP. This study aimed to summarize details and the results of long-term follow-up of PNP after cryoballoon ablation. A total of 511 consecutive AF patients who underwent cryoballoon ablation was included. During right-side PVI, the diaphragmatic compound motor action potential (CMAP) was reduced in 46 (9.0%) patients and PNP occurred in 29 (5.7%) patients (during right-superior PVI in 20 patients and right-inferior PVI in 9 patients). PNP occurred despite the absence of CMAP reduction in 0.6%. The PV anatomy, freezing parameters and the operator's proficiency were not predictors of PNP. While PNP during RSPVI persisted more than 4 years in 3 (0.6%) patients, all PNP occurred during RIPVI recovered until one year after the ablation. However, there was no significant difference in the recovery duration from PNP between PNP during RSPVI and RIPVI. PNP occurred during cryoballoon ablation in 5.7%. While most patients recovered from PNP within one year after the ablation, PNP during RSPVI persisted more than 4 years in 0.6% of patients.


Assuntos
Angioplastia com Balão/efeitos adversos , Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Paralisia/diagnóstico , Traumatismos dos Nervos Periféricos/diagnóstico , Nervo Frênico/lesões , Idoso , Fibrilação Atrial/patologia , Criocirurgia/instrumentação , Criocirurgia/métodos , Humanos , Masculino , Pessoa de Meia-Idade , Paralisia/etiologia , Paralisia/patologia , Traumatismos dos Nervos Periféricos/etiologia , Traumatismos dos Nervos Periféricos/patologia , Veias Pulmonares/cirurgia , Fatores de Tempo , Resultado do Tratamento
5.
JACC Clin Electrophysiol ; 5(11): 1303-1315, 2019 11.
Artigo em Inglês | MEDLINE | ID: mdl-31753437

RESUMO

OBJECTIVES: This study examined the anatomical or procedural factors associated with severe pulmonary vein (PV) stenosis after cryoballoon PV isolation. BACKGROUND: PV stenosis is a complication associated with cryoballoon ablation. METHODS: The study included 170 consecutive patients with paroxysmal atrial fibrillation who underwent cryoballoon ablation. In addition to factors generally considered to be related to the occurrence of PV stenosis (PV size, cryoballoon application number and time, and minimum freezing temperature), we evaluated the following 4 factors: 1) depth of balloon position; 2) the PV angle (internal angle between each PV and horizontal line); 3) noncoaxial balloon placement (hemispherical occlusion); and 4) contact surface area between the cryoballoon and the PV wall (defined as the balloon contact ratio). RESULTS: Severe PV stenosis (≥75% area reduction) was observed in 9 (1.3%) PVs (6 left superior and 3 right superior PVs) in 9 patients. The PV size, cryoballoon application number and time, minimum freezing temperature, and the depth of cryoballoon position were not significantly associated with occurrence of severe PV stenosis, but the PV angle was significantly smaller in PVs with severe stenosis than it was in those without stenosis (25.6 ± 9.7° vs. 34.2 ± 6.4°; p < 0.001). Hemispherical occlusion was more frequently observed and balloon contact ratio was larger in PVs with severe stenosis (55.6% vs. 14.8%; p = 0.049) than in those without stenosis (0.70 ± 0.06 vs. 0.54 ± 0.08; p < 0.001). CONCLUSIONS: A horizontally connecting PV, noncoaxial placement of cryoballoon, and a larger contact surface area of the cryoballoon were predictors of the occurrence of severe PV stenosis after cryoballoon ablation.


Assuntos
Fibrilação Atrial/cirurgia , Criocirurgia/métodos , Complicações Pós-Operatórias/epidemiologia , Veias Pulmonares/cirurgia , Estenose de Veia Pulmonar/epidemiologia , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Duração da Cirurgia , Veias Pulmonares/anatomia & histologia , Índice de Gravidade de Doença
6.
J Cardiovasc Electrophysiol ; 30(11): 2310-2318, 2019 11.
Artigo em Inglês | MEDLINE | ID: mdl-31452290

RESUMO

BACKGROUND: The presence of heart failure (HF) has been associated with poorer outcomes in patients undergoing catheter ablation (CA) for atrial fibrillation (AF). However, the effectiveness of CA amongst the subset of patients with tachycardia-induced cardiomyopathy (TIC) remains poorly defined. METHODS AND RESULTS: In a retrospective analysis we compared outcomes of first-time CA for persistent AF in a cohort of patients with previously diagnosed TIC (n = 45; age 58 ± 8 years; 91% male) to those with structurally normal hearts (non-TIC; n = 440; age 55 ± 9 years; 95% male). TIC was defined as an impaired ventricular function (left ventricular ejection function [LVEF] <50%), which was reversed after the treatment of HF. We compared atrial arrhythmias (AAs) recurrence after the CA in the TIC and non-TIC cohorts. In the TIC group, LVEF improved from 35.8% ± 8.1% to 57.5% ± 8.3% after treatment of HF. During 3.3 ± 1.5 years follow-up, AAs-free survival after CA was significantly higher in the TIC group as compared with the non-TIC group (69% vs 42%; P = .001), despite a comparable CA strategy between the two groups. In multivariable analysis, absence of HF with TIC, longer AF duration, and complex fractionated atrial electrogram ablation were independent predictors of arrhythmia recurrence (OR, 1.02; 95% CI, 1.01-1.03; P < .01; OR, 0.40; 95% CI, 0.20-0.79; P < .01 and OR, 2.29; 95%CI; 1.27-4.11; P < .01, respectively). In addition, the outcome after the last procedure was superior in the TIC cohort (89% vs 72%; P = .03) with fewer CA procedures as compared with the non-TIC cohort (1.3 ± 0.5 vs 1.5 ± 0.7; P = .01). CONCLUSIONS: Persistent patients with AF with TIC have a more favorable outcome after the CA as compared with those without.


Assuntos
Fibrilação Atrial/cirurgia , Cardiomiopatias/etiologia , Ablação por Cateter , Potenciais de Ação , Idoso , Fibrilação Atrial/complicações , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/fisiopatologia , Cardiomiopatias/diagnóstico por imagem , Cardiomiopatias/fisiopatologia , Ablação por Cateter/efeitos adversos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Recuperação de Função Fisiológica , Recidiva , Estudos Retrospectivos , Fatores de Risco , Volume Sistólico , Fatores de Tempo , Resultado do Tratamento , Função Ventricular Esquerda
7.
Heart Vessels ; 33(7): 770-776, 2018 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-29357093

RESUMO

Atrial fibrillation (AF), especially asymptomatic cases, is often detected by medical checkups. We investigated the outcome of AF ablation in cases detected by medical checkups. We reviewed the data of 735 patients with AF (56 ± 10 years, paroxysmal: 441 patients) who underwent initial catheter ablation. All patients were divided into two groups based on their AF being diagnosed either by a medical checkup (group M) or not (group NM). AF was diagnosed by medical checkups in 263 (36%) patients. In Group M, the age was younger, time from the diagnosis to ablation shorter, left atrium dimension larger, and left ventricular ejection fraction lower than in Group NM. Male gender, persistent AF, and asymptomatic AF were more frequently seen in Group M than in Group NM. A mean of 13 ± 11 months after the initial ablation procedure, AF recurrence was more frequently observed in group M compared to group NM (P = 0.018). While the AF recurrence rate was similar in both groups in persistent AF patients (P = 0.87), it was more frequently observed in Group M than in Group NM in paroxysmal AF patients (P = 0.005). AF diagnosed by medical checkups was often associated with a worse outcome of catheter ablation, especially in paroxysmal AF patients.


Assuntos
Fibrilação Atrial/diagnóstico , Ablação por Cateter , Taquicardia Paroxística/diagnóstico , Angiografia , Fibrilação Atrial/cirurgia , Ecocardiografia Transesofagiana , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Taquicardia Paroxística/cirurgia , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...