Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 22
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Water Res ; 260: 121858, 2024 May 30.
Artigo em Inglês | MEDLINE | ID: mdl-38936269

RESUMO

Wastewater treatment plants (WWTPs) provide vital services to the public by removing contaminants from wastewater prior to environmental discharge or reuse for beneficial purposes. WWTP workers occupationally exposed to wastewater can be at risk of respiratory or gastrointestinal diseases. The study objectives were to: (1) quantify pathogens and pathogen indicators in wastewater aerosols near different WWTP processes/unit operations, (2) develop a QMRA model for multi-pathogen and multi-exposure pathway risks, and (3) create a web-based application to perform and communicate risk calculations for wastewater workers. Case studies for seven different WWTP job tasks were performed investigating infection risk across nine different enteric and respiratory pathogens. It was observed that the ingestion risk among job tasks was highest for "walking the WWTP," which involved exposure from splashing, bioaerosols, and hand-to-mouth contact from touching contaminated surfaces. There was also a notable difference in exposure risk during peak (5:00am-9:00am) and non-peak hours (9:00am- 5:00am), with risks during the peak flow hours of the early morning assumed to be 5 times greater than non-peak hours. N95 respirator usage reduced median respiratory risks by 77 %. The developed tool performs multiple QMRA calculations to estimate WWTP workers' infection risks from accidental ingestion or inhalation of wastewater from multiple pathogens and exposure scenarios, which can inform risk management strategies to protect occupational health. However, more data are needed to reduce uncertainty in model estimates, including comparative data for pathogen concentrations in wastewater during peak and non-peak hours. QMRA tools will increase accessibility of risk models for utilization in decision-making.

2.
Water Res ; 246: 120644, 2023 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-37844338

RESUMO

Concerns of fecal-aerosol transmission of coronavirus disease 2019 (COVID-2019) coupled with increased transmissibility and disease severity of Delta and Omicron variants of concern (VOC) of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2), suggest studies on survival of VOC in wastewater are warranted. To the best of our knowledge, this is the first study to investigate the survivability of Delta and Omicron VOC in filtered and unfiltered raw wastewater, and secondary effluent at room temperature (23 °C). The time required for 90 % inactivation (T90) of Delta and Omicron VOC in unfiltered raw wastewater was calculated as 17.7 and 15.3 h, respectively. Rapid inactivation of VOC in wastewater and inability to isolate SARS-CoV-2 in wastewater suggest risks from fecal-aerosol transmission are low. Nevertheless, high transmissibility of VOC cautions overruling fecal-aerosol transmission of COVID-19. Future studies on survival of SARS-CoV-2 in wastewater should attempt viral culture by spiking feces collected from COVID-19 infected patients into wastewater to match the real-world scenario.


Assuntos
COVID-19 , SARS-CoV-2 , Humanos , Águas Residuárias , Aerossóis e Gotículas Respiratórios
3.
Food Environ Virol ; 15(3): 262-264, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37421543

RESUMO

Severe Acute Respiratory Syndrome Coronavirus-2 (SARS-CoV-2) is present in both respiratory secretions and feces, creating its potential for transmission by swimming pools. Recreational water activity is known to be at increased risk of respiratory infections and respiratory viruses have caused been detected and have caused outbreaks in swimming pools. However, little is known regarding the chlorine inactivation of SARS-CoV-2 in water typical of swimming pools in the USA. In this study, the inactivation of SARS-CoV-2 Isolate hCoV-19/USA-WA1/2020 was observed in water by chlorination. All experiments were conducted within a BSL-3 laboratory at room temperature. Our results show that the virus was reduced by 3.5 log (> 99.9%) after 30 s of 2.05-mg/L free chlorine contact and greater than 4.17 log (limit of detection) (> 99.99%) within 2 min.


Assuntos
COVID-19 , SARS-CoV-2 , Humanos , Água , Halogenação , Cloro/farmacologia
4.
Infect Prev Pract ; 5(3): 100293, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37359396

RESUMO

Background: Hand hygiene is critical to lower the potential for the spread of SARS-CoV-2 and other infectious agents by direct contact. When running water and soap are not available for hand hygiene, ethanol-based hand sanitizers are currently the recommended standard of care [1-3]. Though recently published data showed comparable in vitro effectiveness of benzalkonium chloride (BAK)-based and ethanol-based hand sanitizers against SARS-CoV-2 virus, a paucity of peer-reviewed data on the effectiveness of these formulations against other types of infective coronaviruses remains. This work assessed human coronavirus HCoV-229E (genus Alphacoronavirus) concurrently with SARS-CoV-2, Isolate USA-WA1/2020 (genus Betacoronavirus) to fill this gap. Methods: The test was conducted according to EN14476:2013-A2:2019 [EN14476] Quantitative Suspension Test for the Evaluation of Virucidal Activity in the Medical Area [4]. Two BAK-based hand sanitizers, five ethanol-based hand sanitizers, and an 80% ethanol reference formulation were tested for antiviral activity against SARS-CoV-2 and HCoV-229E at 15- and 30- second contact times. Results: Both SARS-CoV-2 and HCoV-229E were reduced by greater than 4.00-log10 within 15 seconds of contact. Virus decay constants (k) following first-order kinetics were similar for BAK and ethanol-based formulations against both test viruses. The SARS-CoV-2 results reported herein mirrored previous data reported by Herdt et al. (2021). Conclusion: BAK and ethanol hand sanitizer formulations inactivate SARS-CoV-2 and HCoV-229E at similar rates. This data supports previously published effectiveness data for both chemistries and indicates that additional coronavirus strains and variants would demonstrate similar inactivation trends.

5.
Water Sci Technol ; 87(9): 2304-2314, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-37186632

RESUMO

Microfiltration (MF) has been widely adopted as an advanced treatment process to reduce suspended solids and turbidity in treated wastewater effluents designated for potable reuse. Although microfilter pores are much larger than viruses, the addition of a coagulant upstream of a microfilter system can achieve stable virus removal. Ceramic membranes have a narrow pore size distribution to achieve the high removal of contaminants. This study aims to evaluate virus log reduction using bench-scale coagulation and ceramic membrane MF. To investigate the effects of differences in net surface hydrophobicity, 18 sewage-derived F-specific RNA phages (FRNAPHs) were used for batch hydrophobicity and coagulation-MF tests. The capability of bench-scale coagulation and ceramic membrane MF under continuous automated long-term operation was tested to remove the lab reference strain MS2 and three selected FRNAPH isolates which varied by surface property. Median virus log reduction values (LRVs) exceeding 6.2 were obtained for all three isolates and MS2. Although coagulation and hydrophobicity were positively correlated, the virus isolate demonstrating the lowest level of hydrophobicity and coagulation (genogroup I) still exhibited a high LRV. Thus, coagulation and ceramic membrane MF systems may serve as viable options for virus removal during water reclamation and advanced treatment.


Assuntos
Fagos RNA , Vírus , Purificação da Água , Ultrafiltração , Cerâmica/química , Membranas Artificiais
6.
Water Res ; 240: 120019, 2023 Jul 15.
Artigo em Inglês | MEDLINE | ID: mdl-37216784

RESUMO

Membrane distillation (MD) is a thermally-driven process that can treat high concentration streams and provide a dual barrier for rejection and reduction of pathogens. Thus, MD has potential applications in treating concentrated wastewater brines for enhancing water recovery and potable water reuse. In bench-scale studies, it was demonstrated that MD can provide high rejection of MS2 and PhiX174 bacteriophage viruses, and when operating at temperatures greater than 55 °C, can reduce virus levels in the concentrate. However, bench-scale MD results cannot directly be used to predict pilot-scale contaminant rejection and removal of viruses because of the lower water flux and higher transmembrane hydraulic pressure difference in pilot-scale systems. Thus far, virus rejection and removal have not been quantified in pilot-scale MD systems. In this work, the rejection of MS2 and PhiX174 at low (40 °C) and high (70 °C) inlet temperatures is quantified in a pilot-scale air-gap MD system using tertiary treated wastewater. Both viruses were detected in the distillate which suggests the presence of pore flow; the virus rejection at a hot inlet temperature of 40 °C for MS2 and PhiX174 were 1.6-log10 and 3.1-log10, respectively. At 70 °C, virus concentrations in the brine decreased and were below the detection limit (1 PFU per 100 mL) after 4.5 h, however, viruses were also detected in the distillate in that duration. Results demonstrate that virus rejection is lower in pilot-scale experiments because of increased pore flow that is not captured in bench-scale experiments.


Assuntos
Águas Residuárias , Purificação da Água , Destilação/métodos , Purificação da Água/métodos , Osmose , Membranas Artificiais , Água
7.
Sci Total Environ ; 882: 163049, 2023 Jul 15.
Artigo em Inglês | MEDLINE | ID: mdl-36990233

RESUMO

The ongoing pandemic of Coronavirus disease 2019 (COVID-19) has affected >600 million people with >6 million deaths. Although Severe Acute Respiratory Syndrome-Coronavirus-2 (SARS-CoV-2), the etiologic agent of COVID-19, is transmitted via respiratory droplets or direct contact, isolation of viable SARS-CoV-2 in feces has been reported. Therefore, there is a need for understanding the persistence of SARS-CoV-2 and emerging variants in wastewater. In this study, the survival of SARS-CoV-2 isolate hCoV-19/USA-WA1/2020 was observed in three wastewater matrices - filtered and unfiltered raw wastewater, and secondary effluent. All experiments were conducted within a BSL-3 laboratory at room temperature. The time required for inactivation of 90 % (T90) of SARS-CoV-2 was 10.4, 10.8, and 18.3 h for unfiltered raw, filtered raw, and secondary effluent, respectively. Progressive decline in infectivity of the virus following first order kinetics was noted in these wastewater matrices. To the best of our knowledge, this is the first study to describe the survival of SARS-CoV-2 in secondary effluent.


Assuntos
COVID-19 , SARS-CoV-2 , Humanos , Águas Residuárias , Pandemias , Fezes
8.
Infect Control Hosp Epidemiol ; 44(3): 507-509, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-34852869

RESUMO

The surface environment in rooms of coronavirus disease 2019 (COVID-19) patients may be persistently contaminated despite disinfection. A continuously active disinfectant demonstrated excellent sustained antiviral activity following a 48-hour period of wear and abrasion exposures with reinoculations. Reductions of >4-log10 were achieved within a 1-minute contact time for severe acute respiratory coronavirus virus 2 (SARS-CoV-2) and the human coronavirus, 229E.


Assuntos
COVID-19 , Coronavirus Humano 229E , Desinfetantes , Humanos , Coronavirus Humano 229E/fisiologia , COVID-19/prevenção & controle , SARS-CoV-2 , Desinfetantes/farmacologia , Antivirais
9.
Infect Control Hosp Epidemiol ; 44(2): 335-337, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-34612187

RESUMO

Respiratory viruses can be transmitted by fomite contact, but no data currently exist on the transfer of enveloped viruses. The transfer efficiency of human coronavirus from various hard surfaces ranged from 0.46% to 49.0%. This information can be used to model the fomite transmission of enveloped viruses.


Assuntos
Coronavirus Humano 229E , Vírus , Humanos , Fômites , Mãos , Pele
10.
Photochem Photobiol ; 99(3): 975-982, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36129750

RESUMO

Germicidal ultraviolet (UV) devices have been widely used for pathogen disinfection in water, air, and on food and surfaces. Emerging UV technologies, like the krypton chloride (KrCl*) excimer emitting at 222 nm, are rapidly gaining popularity due to their minimal adverse effects on skin and eyes compared with conventional UV lamps emitting at 254 nm, opening opportunities for UV disinfection in occupied public spaces. In this study, inactivation of seven bacteria and five viruses, including waterborne, foodborne and respiratory pathogens, was determined in a thin-film aqueous solution using a filtered KrCl* excimer emitting primarily at 222 nm. Our results show that the KrCl* excimer can effectively inactivate all tested bacteria and viruses, with most microorganisms achieving more than 4-log (99.99%) reduction with a UV dose of 10 mJ cm-2 . Compared with conventional UV lamps, the KrCl* excimer lamp exhibited better disinfection performance for viruses but was slightly less effective for bacteria. The relationships between UV sensitivities at 222 and 254 nm for bacteria and viruses were evaluated using regression analysis, resulting in factors that could be used to estimate the KrCl* excimer disinfection performance from well-documented UV kinetics using conventional 254 nm UV lamps. This study provides fundamental information for pathogen disinfection when employing KrCl* excimers.


Assuntos
Bactérias , Desinfecção , Desinfecção/métodos , Bactérias/efeitos da radiação , Água , Raios Ultravioleta , Criptônio
11.
Int J Environ Health Res ; 33(12): 1591-1603, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-35951754

RESUMO

Propolis is a resinous substance collected by bees (Apis mellifera). It is used for its biological properties. This natural product is available as a safe therapeutic option. Herein, we report the antiviral effects of brown propolis extract from Mexico and green and red propolis extracts from Brazil, as well as their phenolic compounds (quercetin, caffeic acid, and rutin) in preventing infection of MRC-5 cells by HCoV-229E. Normal human fibroblast lung cells (MRC-5) were used to determine the cytotoxicity of the compounds. All samples studied showed antiviral activity. Green and brown propolis extracts, and quercetin exhibited the best EC50 values with values of 19.080, 11.240, and 77.208 µg/mL against HCoV-229E, respectively, and with TC50 of 62.19, 29.192, and 298 µg/mL on MRC-5 cells, respectively. These results are the first in vitro study of the effects of propolis on HCoV-229E and provide the basis for the development of natural formulations against other coronavirus strains.


Assuntos
Coronavirus Humano 229E , Própole , Humanos , Animais , Própole/farmacologia , Brasil , Quercetina/farmacologia , México , Fenóis/farmacologia , Antivirais/farmacologia
12.
Am J Infect Control ; 49(12): 1569-1571, 2021 12.
Artigo em Inglês | MEDLINE | ID: mdl-34499978

RESUMO

The COVID-19 pandemic has accelerated the demand for alternatives to standard cleaning and disinfection practices. Antiviral coatingsmay provide an alternative to common surface treatments. A newly developed quaternary ammonium polymer coating was applied to stainless steel coupons and evaluated for efficacy against human coronavirus 229E and SARS-CoV-2. The polymer coating reduced levels of both test viruses by greater than 99.9% relative to non-coated stainless steel coupons during a 2-hour contact time.


Assuntos
COVID-19 , Coronavirus Humano 229E , Antivirais , Humanos , Pandemias , SARS-CoV-2
13.
Environ Sci Technol Lett ; 8(8): 713-718, 2021 Jan 10.
Artigo em Inglês | MEDLINE | ID: mdl-37566318

RESUMO

The persistence of pathogenic microorganisms in treated wastewater effluent makes disinfection crucial to achieve wastewater reuse. Membrane processes such as ultrafiltration and reverse osmosis (RO) have shown promising results for virus and other contaminant removal from treated wastewater effluents for reuse application. However, RO produces a concentrate stream which contains high concentrations of pathogens and contaminants that often requires treatment and volume reduction before disposal. Membrane distillation (MD) is a treatment process that can reduce RO concentrate volume while augmenting the potable water supply. MD is also a dual barrier approach for virus removal as it operates at a high temperature and permeates only the vapor phase through the membrane interface. The effects of temperature on viable virus concentration and membrane rejection of viruses in MD are investigated in this study using two nonenveloped phages frequently used as enteric virus surrogates (MS2 and PhiX174) and an enveloped pathogenic virus (HCoV-229E). At typical MD operating temperatures (greater than 65 °C), viable concentrations of all three viruses were reduced by thermal inactivation by more than 6-log10 for MS2 and PhiX174 and more than 3-log10 for HCoV-229E. Also, membrane rejection was greater than 6-log10 for MS2 and PhiX174 and greater than 2.5-log10 for HCoV-229E.

14.
Am J Vet Res ; 81(6): 506-513, 2020 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-32436797

RESUMO

OBJECTIVE: To determine whether exposure to UV germicidal irradiation (UVGI) reduces concentrations of viable aerosolized microorganisms (attenuated strains of common veterinary pathogens) in a simulated heating, ventilation, and air conditioning (HVAC) system. SAMPLE: 42 air samples seeded with bacteriophage MS2 or attenuated strains of Bordetella bronchiseptica, feline calicivirus, feline herpesvirus-1, canine parvovirus, or canine distemper virus (6/microorganism) or with no microorganisms added (6). PROCEDURES: A simulated HVAC unit was built that included a nebulizer to aerosolize microorganisms suspended in phosphate-buffered water, a fan to produce airflow, 2 UVGI bulb systems, and an impinger for air sampling. Ten-minute trials (3 with UVGI, 3 without UVGI, and 1 negative control) were conducted for each microorganism. Impingers collected microorganisms into phosphate-buffered water for subsequent quantification with culture-based assays. Results for samples yielding no target microorganisms were recorded as the assay's lower limit of detection. Statistical analysis was not performed. RESULTS: The UVGI treatment resulted in subjectively lower concentrations of viable MS2, B bronchiseptica, and canine distemper virus (arithmetic mean ± SD log10 microorganism reduction, 2.57 ± 0.47, ≥ 3.45 ± 0.24, and ≥ 1.50 ± 0.25, respectively) collected from air. Feline herpesvirus-1 was detected in only 1 sample without and no samples with UVGI treatment. Feline calicivirus and canine parvovirus were not detectable in any collected samples. CONCLUSIONS AND CLINICAL RELEVANCE: Results for some surrogates of veterinary pathogens suggested a potential benefit to supplementing manual disinfection practices with UVGI-based air cleaning systems in animal care environments. Further research is needed to investigate the utility of UVGI in operating HVAC systems.


Assuntos
Microbiologia do Ar , Raios Ultravioleta , Animais , Gatos , Desinfecção , Ventilação
15.
Risk Anal ; 39(12): 2608-2624, 2019 12.
Artigo em Inglês | MEDLINE | ID: mdl-31524301

RESUMO

Middle Eastern respiratory syndrome, an emerging viral infection with a global case fatality rate of 35.5%, caused major outbreaks first in 2012 and 2015, though new cases are continuously reported around the world. Transmission is believed to mainly occur in healthcare settings through aerosolized particles. This study uses Quantitative Microbial Risk Assessment to develop a generalizable model that can assist with interpreting reported outbreak data or predict risk of infection with or without the recommended strategies. The exposure scenario includes a single index patient emitting virus-containing aerosols into the air by coughing, leading to short- and long-range airborne exposures for other patients in the same room, nurses, healthcare workers, and family visitors. Aerosol transport modeling was coupled with Monte Carlo simulation to evaluate the risk of MERS illness for the exposed population. Results from a typical scenario show the daily mean risk of infection to be the highest for the nurses and healthcare workers (8.49 × 10-4 and 7.91 × 10-4 , respectively), and the lowest for family visitors and patients staying in the same room (3.12 × 10-4 and 1.29 × 10-4 , respectively). Sensitivity analysis indicates that more than 90% of the uncertainty in the risk characterization is due to the viral concentration in saliva. Assessment of risk interventions showed that respiratory masks were found to have a greater effect in reducing the risks for all the groups evaluated (>90% risk reduction), while increasing the air exchange was effective for the other patients in the same room only (up to 58% risk reduction).


Assuntos
Infecções por Coronavirus/transmissão , Coronavírus da Síndrome Respiratória do Oriente Médio , Modelos Biológicos , Aerossóis , Microbiologia do Ar , Simulação por Computador , Infecções por Coronavirus/epidemiologia , Infecções por Coronavirus/virologia , Infecção Hospitalar/epidemiologia , Infecção Hospitalar/prevenção & controle , Infecção Hospitalar/transmissão , Surtos de Doenças/estatística & dados numéricos , Pessoal de Saúde , Humanos , Transmissão de Doença Infecciosa do Paciente para o Profissional/prevenção & controle , Transmissão de Doença Infecciosa do Paciente para o Profissional/estatística & dados numéricos , Máscaras , Método de Monte Carlo , República da Coreia/epidemiologia , Medição de Risco/métodos , Medição de Risco/estatística & dados numéricos , Gestão de Riscos , Saliva/virologia
16.
Sensors (Basel) ; 18(7)2018 Jul 16.
Artigo em Inglês | MEDLINE | ID: mdl-30012989

RESUMO

Advanced treatment of reclaimed water prior to potable reuse normally results in the inactivation of bacterial populations, however, incremental treatment failure can result in bacteria, including pathogens, remaining viable. Therefore, potential microorganisms need to be detected in real-time to preclude potential adverse human health effects. Real-time detection of microbes presents unique problems which are dependent on the water quality of the test water, including parameters such as particulate content and turbidity, and natural organic matter content. In addition, microbes are unusual in that: (i) viability and culturability are not always synonymous; (ii) viability in water can be reduced by osmotic stress; and (iii) bacteria can invoke repair mechanisms in response to UV disinfection resulting in regrowth of bacterial populations. All these issues related to bacteria affect the efficacy of real-time detection for bacteria. Here we evaluate three different sensors suitable for specific water qualities. The sensor A is an on-line, real-time sensor that allows for the continuous monitoring of particulates (including microbial contaminants) using multi-angle-light scattering (MALS) technology. The sensor B is a microbial detection system that uses optical technique, Mie light scattering, for particle sizing and fluorescence emission for viable bacteria detection. The last sensor C was based on adenosine triphosphate (ATP) production. E. coli was used a model organism and out of all tested sensors, we found the sensor C to be the most accurate. It has a great potential as a surrogate parameter for microbial loads in test waters and be useful for process control in treatment trains.


Assuntos
Desinfecção/normas , Escherichia coli/isolamento & purificação , Microbiologia da Água , Qualidade da Água , Trifosfato de Adenosina/biossíntese , Desinfecção/métodos , Escherichia coli/metabolismo , Escherichia coli/efeitos da radiação , Humanos , Pressão Osmótica , Fatores de Tempo
17.
Sci Total Environ ; 615: 15-19, 2018 Feb 15.
Artigo em Inglês | MEDLINE | ID: mdl-28961437

RESUMO

Micro-scale technology was used to obtain survival data for three animal viruses and two bacteriophages during anaerobic digestion. The data for adenoviruses, MS2 and Φ6 provide the first published reports for survival of these viruses during mesophilic anaerobic digestion. Data were also obtained for thermophilic digestion, which showed greater inactivation of viruses at the higher temperature. Data on the survival of Φ6 are of particular interest since it is a lipid-based virus which has been suggested as a surrogate for the Ebola virus. In contrast, MS2 was found to be an inappropriate surrogate for Ebola.


Assuntos
Adenoviridae/fisiologia , Bacteriófagos/fisiologia , Reatores Biológicos/virologia , Temperatura Alta , Inativação de Vírus , Anaerobiose , Esgotos/virologia
18.
J Dent Hyg ; 90(6): 354-361, 2016 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-29118156

RESUMO

Purpose: The purpose of this study was to characterize the occurrence of heterotrophic plate count bacteria (HPCs), fecal bacterial indicators, and methicillin-resistant Staphylococcus aureus (MRSA) on hard, nonporous surfaces (fomites) commonly found in dental offices, and to assess the impact of a hygienic disinfection intervention on the reduction of these bacteria in the office setting.Methods: Samples of various fomites were collected from dental offices located in Arizona (6) and Illinois (4) and assayed for HPCs, total coliforms, Escherichia coli, and MRSA in order to establish baseline bacterial levels. Dental office personnel were then provided with disposable disinfectant wipes containing hydrogen peroxide to use in the office, and the surfaces were subsequently resampled to assess their impact on the specified bacterial populations.Results: The greatest numbers of HPCs were found on the patients' arm rest and office phones, with dental tool handles and the dentist examination lights yielding the lowest levels. Coliform bacteria and E. coli were also detected on those surfaces demonstrating the highest HPCs, and were cultured from other fomites as well. MRSA was also isolated from 5% of the fomites tested. The use of disinfectant wipes significantly reduced the numbers of HPC bacteria detected on fomites (p=0.002). No total coliforms, E. coli, or MRSA were cultured from disinfected fomites following the hygienic intervention.Conclusion: The use of hydrogen peroxide-impregnated towelettes reduced total bacterial numbers on fomites commonly located in dental offices. Total coliforms, E. coli, and MRSA were reduced to levels below detection.


Assuntos
Bactérias/isolamento & purificação , Consultórios Odontológicos , Desinfecção , Peróxido de Hidrogênio , Arizona , Escherichia coli/isolamento & purificação , Humanos , Illinois , Staphylococcus aureus Resistente à Meticilina/isolamento & purificação
19.
Food Environ Virol ; 5(2): 91-6, 2013 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-23412726

RESUMO

Enteric viruses are often present in low numbers in various water matrices. Virus sampling therefore involves multiple concentration steps to condense large samples down to small volumes for detection by cell culture or molecular assays. The NanoCeram® Virus Sampler has been demonstrated to be effective for the recovery of viruses from tap water, surface waters, and seawater. The goal of this study was to evaluate a new method using NanoCeram® filters for the recovery of poliovirus 1 (PV-1) from treated wastewater. Activated sludge effluent samples were spiked with PV-1 and concentrated in side-by-side tests by two methods: (1) NanoCeram® filtration, elution with sodium polyphosphate buffer, secondary concentration via centrifugal ultrafiltration; and (2) 1MDS filtration, elution with beef extract, secondary concentration via organic flocculation. The virus retention and elution efficiencies did not differ significantly between the two methods. In contrast, the secondary concentrate volume was smaller for the NanoCeram® method (8.4 vs. 30 mL) and the secondary concentration efficiencies were different between the two methods with 98 % for centrifugal ultrafiltration (NanoCeram® and 45 % for organic flocculation (1MDS). The overall method efficiencies were significantly different (P ≤ 0.05) with the NanoCeram® method yielding a 57 % and the 1MDS a 23 % virus recovery. In addition, there appeared to be less interference with viral detection via polymerase chain reaction with the NanoCeram® concentrates. This NanoCeram® method therefore is able to efficiently recover PV-1 from large volumes of wastewater and may serve as an inexpensive alternative to the standard 1MDS filter method for such applications.


Assuntos
Poliovirus/isolamento & purificação , Esgotos/virologia , Ultrafiltração/métodos , Águas Residuárias/virologia , Microbiologia da Água , Soluções Tampão , Reação em Cadeia da Polimerase Via Transcriptase Reversa , Ultrafiltração/instrumentação
20.
Food Environ Virol ; 4(2): 41-67, 2012 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-23412811

RESUMO

Enteric viruses are a cause of waterborne disease worldwide, and low numbers in drinking water can present a significant risk of infection. Because the numbers are often quite low, large volumes (100-1,000 L) of water are usually processed. The VIRADEL method using microporous filters is most commonly used today for this purpose. Negatively charged filters require the addition of multivalent salts and acidification of the water sample to effect virus adsorption, which can make large-volume sampling difficult. Positively charged filters require no preconditioning of samples, and are able to concentrate viruses from water over a greater pH range than electronegative filters. The most widely used electropositive filter is the Virosorb 1MDS; however, the Environmental Protection Agency has added the positively charged NanoCeram filters to their proposed Method 1615. Ultrafilters concentrate viruses based on size exclusion rather than electrokinetics, but are impractical for field sampling or processing of turbid water. Elution (recovery) of viruses from filters following concentration is performed with organic (e.g., beef extract) or inorganic solutions (e.g., sodium polyphosphates). Eluates are then reconcentrated to decrease the sample volume to enhance detection methods (e.g., cell culture infectivity assays and molecular detection techniques). While the majority of available filters have demonstrated high virus retention efficiencies, the methods to elute and reconcentrate viruses have met with varying degrees of success due to the biological variability of viruses present in water.


Assuntos
Doenças do Sistema Digestório/virologia , Filtração/métodos , Vírus , Microbiologia da Água , Abastecimento de Água , Humanos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...