Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
2.
Case Rep Orthop ; 2020: 6842986, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-33029440

RESUMO

A 43-year-old female shiatsu therapist complained of sudden snapping of the metacarpophalangeal joints (MCPjs) of both ring fingers during a specific hand posture. The extensor tendon of the ring finger was dislocated ulnarly when the MCPj of the ring finger was flexed and deviated ulnarly and the MCPj of the middle finger was extended. Surgical exploration revealed an attenuated radial sagittal band. We plicated the juncturae tendinum of the extensor digitorum communis between the middle and ring fingers and released the ulnar sagittal band partially to centralise the extensor tendon excursion. Twenty-six months postoperatively, the patient regained full active and passive range of motion of all fingers without extensor tendon dislocation or snapping in either hand during work.

3.
Tissue Eng Part A ; 23(17-18): 923-934, 2017 09.
Artigo em Inglês | MEDLINE | ID: mdl-28426371

RESUMO

The development of engineered tissues has progressed over the past 20 years from in vitro characterization to in vivo implementation. For musculoskeletal tissue engineering in particular, the emphasis of many of these studies was to select conditions that maximized functional and compositional gains in vitro. However, the transition from the favorable in vitro culture environment to a less favorable in vivo environment has proven difficult, and, in many cases, engineered tissues do not retain their preimplantation phenotype after even short periods in vivo. Our laboratory recently developed disc-like angle-ply structures (DAPS), an engineered intervertebral disc for total disc replacement. In this study, we tested six different preculture media formulations (three serum-containing and three chemically defined, with varying doses of transforming growth factor ß3 [TGF-ß3] and varying strategies to introduce serum) for their ability to preserve DAPS composition and metabolic activity during the transition from in vitro culture to in vivo implantation in a subcutaneous athymic rat model. We assayed implants before and after implantation to determine collagen content, glycosaminoglycan (GAG) content, metabolic activity, and magnetic resonance imaging (MRI) characteristics. A chemically defined media condition that incorporated TGF-ß3 promoted the deposition of GAG and collagen in DAPS in vitro, the maintenance of accumulated matrix in vivo, and minimal changes in the metabolic activity of cells within the construct. Preculture in serum-containing media (with or without TGF-ß3) was not compatible with DAPS maturation, particularly in the nucleus pulposus (NP) region. All groups showed increased collagen production after implantation. These findings define a favorable preculture strategy for the translation of engineered discs seeded with disc cells.


Assuntos
Bioprótese , Técnicas de Cultura de Células/métodos , Disco Intervertebral , Fator de Crescimento Transformador beta3/farmacologia , Animais , Bovinos , Ratos , Ratos Nus , Substituição Total de Disco
4.
Acta Biomater ; 26: 97-104, 2015 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-26248165

RESUMO

Tissue engineering strategies have emerged in response to the growing prevalence of chronic musculoskeletal conditions, with many of these regenerative methods currently being evaluated in translational animal models. Engineered replacements for fibrous tissues such as the meniscus, annulus fibrosus, tendons, and ligaments are subjected to challenging physiologic loads, and are difficult to track in vivo using standard techniques. The diagnosis and treatment of musculoskeletal conditions depends heavily on radiographic assessment, and a number of currently available implants utilize radiopaque markers to facilitate in vivo imaging. In this study, we developed a nanofibrous scaffold in which individual fibers included radiopaque nanoparticles. Inclusion of radiopaque particles increased the tensile modulus of the scaffold and imparted radiation attenuation within the range of cortical bone. When scaffolds were seeded with bovine mesenchymal stem cells in vitro, there was no change in cell proliferation and no evidence of promiscuous conversion to an osteogenic phenotype. Scaffolds were implanted ex vivo in a model of a meniscal tear in a bovine joint and in vivo in a model of total disc replacement in the rat coccygeal spine (tail), and were visualized via fluoroscopy and microcomputed tomography. In the disc replacement model, histological analysis at 4 weeks showed that the scaffold was biocompatible and supported the deposition of fibrous tissue in vivo. Nanofibrous scaffolds that include radiopaque nanoparticles provide a biocompatible template with sufficient radiopacity for in vivo visualization in both small and large animal models. This radiopacity may facilitate image-guided implantation and non-invasive long-term evaluation of scaffold location and performance. STATEMENT OF SIGNIFICANCE: The healing capacity of fibrous musculoskeletal tissues is limited, and injury or degeneration of these tissues compromises the standard of living of millions in the US. Tissue engineering repair strategies for the intervertebral disc, meniscus, tendon and ligament have progressed from in vitro to in vivo evaluation using a variety of animal models, and the clinical application of these technologies is imminent. The composition of most scaffold materials however does not allow for visualization by methods available to clinicians (e.g., radiography), and thus it is not possible to assess their performance in situ. In this work, we describe a radiopaque nanofibrous scaffold that can be visualized radiographically in both small and large animal models and serve as a framework for the development of an engineered fibrous tissue.


Assuntos
Galvanoplastia/métodos , Regeneração Tecidual Guiada/instrumentação , Prótese Articular , Nanofibras/química , Engenharia Tecidual/instrumentação , Alicerces Teciduais , Animais , Bovinos , Desenho de Equipamento , Análise de Falha de Equipamento , Nanofibras/ultraestrutura , Ratos Sprague-Dawley , Rotação , Espalhamento de Radiação , Tomografia Computadorizada por Raios X/métodos , Raios X
5.
J Orthop Res ; 33(1): 140-8, 2015 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-25273831

RESUMO

Magnetic resonance imaging (MRI) with T2-weighting is routinely performed to assess intervertebral disc degeneration. Standard clinical evaluations of MR images are qualitative, however, and do not focus on region-specific alterations in the disc. Utilizing a rabbit needle puncture model, T2 mapping was performed on injured discs to develop a quantitative description of the degenerative process following puncture. To do so, an 18G needle was inserted into four discs per rabbit (L3/L4 to L6/L7) and T2 maps were generated pre- and 4 weeks post-injury. Individual T2 maps were normalized to a disc-specific coordinate system and then averaged for pre- and post-injury population composite T2 maps. We also developed a method to automatically segment the nucleus pulposus by fitting the NP region of the T2 maps with modified 2-D and 3-D Gaussian distribution functions. Puncture injury produced alterations in MR signal intensity in a region-specific manner mirroring human degeneration. Population average T2 maps provided a quantitative representation of the injury response, and identified deviations of individual degenerate discs from the pre-injury population. We found that the response to standardized injury was modest at lower lumbar levels, likely as a result of increased disc dimensions. These tools will be valuable for the quantitative characterization of disc degeneration in future clinical and pre-clinical studies.


Assuntos
Degeneração do Disco Intervertebral/patologia , Vértebras Lombares/patologia , Imageamento por Ressonância Magnética/métodos , Animais , Modelos Animais de Doenças , Degeneração do Disco Intervertebral/diagnóstico por imagem , Vértebras Lombares/diagnóstico por imagem , Distribuição Normal , Coelhos , Radiografia , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...