Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Talanta ; 238(Pt 2): 123056, 2022 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-34801912

RESUMO

We report the use of a laser-based fabrication process in the creation of paper-based flow-through filters that when combined with a traditional lateral flow immunoassay provide an alternative pathway for the detection of a pre-determined analyte over a wide concentration range. The laser-patterned approach was used to create polymeric structures that alter the porosity of the paper to produce porous flow-through filters, with controllable levels of porosity. When located on the top of the front end of a lateral flow immunoassay the flow-through filters were shown to block particles (of known sizes of 200 nm, 500 nm, 1000 nm and 3000 nm) that exceed the effective pore size of the filter while allowing smaller particles to flow through onto a lateral flow immunoassay. The analyte detection is based on the use of a size-exclusive filter that retains a complex (∼3 µm in size) formed by the binding of the target analyte with two antibodies each of which is tagged with different-sized labels (40 nm Au-nanoparticles and 3 µm latex beads), and which is larger than the effective pore size of the filter. This method was tested for the detection of C-reactive protein in a broad concentration range from 10 ng/ml to 100,000 ng/ml with a limit-of-detection found at 13 ng/ml and unlike other reported methods used for analyte detection, with this technique we are able to counter the Hook effect which is a limiting factor in many lateral flow immunoassays.


Assuntos
Proteína C-Reativa , Imunoensaio , Nanopartículas , Anticorpos , Proteína C-Reativa/isolamento & purificação , Imunoensaio/instrumentação , Imunoensaio/métodos , Lasers
3.
Fresenius J Anal Chem ; 370(4): 426-8, 2001 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-11495068

RESUMO

A new ion chromatographic (IC) technique has been developed for the determination of inorganic cations in biological fluids with direct sample injection. This involved the use of a mixed zwitterionic-micelle/electrolyte solution as an eluent. The proteins in the sample became bound to the zwitterionic micelles in the eluent and were thus eliminated from the column. The cations were separated by cation exchange. This method is ideal for the online, simultaneous determination of common inorganic cations (Na+, NH4+, K+, Mg2+, and Ca2+) in urine and serum samples. Such an application was demonstrated experimentally. Non-suppressed conductivity was used for analyte detection. The detection limits obtained using this IC system were 2.94, 5.22, 34.9, 32.6, and 56.7 microg/L for Na+, NH4+, K+, Mg2+, and Ca2+, respectively.


Assuntos
Cátions/análise , Cátions/sangue , Cátions/urina , Cromatografia Líquida de Alta Pressão , Condutividade Elétrica , Humanos , Indicadores e Reagentes , Micelas , Proteínas/química , Solubilidade , Solventes
4.
Analyst ; 126(6): 821-4, 2001 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-11445944

RESUMO

An ion chromatographic (IC) method was developed for the high-resolution determination of a sample's free hydrogen ion concentration (H+). Highly purified lithium dodecyl sulfate was used as the stationary phase, a slightly acidified aqueous LiCl solution was used as the mobile phase and conductivity was used for analyte detection. An electrical double layer (EDL) containing H+ was established on the stationary phase by using a slightly acidified electrolyte solution as the eluent. H+ in the EDL protonated any weak acid groups (i.e., silanols) on the stationary phase so that H+ from the sample could be retained/separated purely by dodecyl sulfate. The optimum molar ratio of H+:Li+ in the EDL for this IC system was obtained by using an aqueous solution containing 40.0 mM LiCl and 0.07 mM H2SO4 as the eluent. After separation, H+ was detected by direct conductimetric measurement. An H+ detection limit of better than 8.2 x 10(-6) M was obtained from the analysis of standard aqueous H2SO4 solutions. Other monovalent cations could also be separated with this method, giving detection limits of 7.4 x 10(-5), 4.3 x 10(-5) and 4.2 x 10(-5) M for Na+, NH4+ and K+, respectively. The method was applied to the simultaneous determination of H+, Na+, NH4+ and K+ in acid rain. The results obtained showed a significant improvement in reproducibility when compared with those from a conventional pH-meter. Acid rain samples with a pH < 5 could be analyzed with this IC system.

5.
Fresenius J Anal Chem ; 370(1): 48-51, 2001 May.
Artigo em Inglês | MEDLINE | ID: mdl-11393236

RESUMO

An ion chromatographic (IC) method has been developed for determination of hydrogen ion (H+). It is based on the use of sulfonated cation-exchange resin as stationary phase, aqueous ethylenediamine-N,N,N',N'-tetraacetic acid (dipotassium salt, EDTA-2K, written as K2H2Y) solution as mobile phase, and conductivity for detection. H+ was separated mainly by cation-exchange, but its elution was accelerated by the presence of EDTA. The order of elution for the model cations was H+ > Li+ > Na+ > NH4+ > Ca2+ > > Mg2+. A sharp and highly symmetrical peak was obtained for H+ and this was attributed to the capacity of H2Y2(2-) to receive and bind H+. H+ was detected conductiometrically and detector response (reduction in conductivity as a result of H+ +H2Y2- --> H3Y-) was linearly proportional to the concentration of H+ in the sample. The detection limit for H+ with this IC system was better than 4.7 micromol L(-1). A significant advantage of this method was the ability to separate and determine, in one step, H+ and other cations. The successful determination of H+ and other cation species in real acid-rain samples demonstrated the usefulness of this method.


Assuntos
Chuva Ácida/análise , Cromatografia por Troca Iônica/métodos , Ácido Edético/química , Concentração de Íons de Hidrogênio , Água/química , Resinas de Troca de Cátion , Cromatografia Líquida de Alta Pressão , Ácidos Sulfúricos/química
6.
Anal Sci ; 17(12): 1401-4, 2001 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-11783789

RESUMO

A unified ion chromatographic (IC) system was developed for the determination of acidity or alkalinity. Separation column used was a reversed-phase ODS packed column, which had been modified by saturating it with lithium dodecylsulfate. A slightly acidified LiCl (50 mM LiCl and 0.05 mM H2SO4) aqueous solution was used as the eluent. By conditioning the separation column in this way, both H+ and Li+ ions became bound to the stationary phase. Dodecylsulfate groups with Li+ counterions acted as cation-exchange sites for the separation of hydrogen ions (free acidity determination). The remaining dodecylsulfate groups, with H+ counterions acted as a titrant, which reacted with basic species (total alkalinity determination). The acidity or alkalinity of each sample was measured according to the change in conductance from the eluent baseline level. A positive peak was observed from those samples with a free acidity greater than their total alkalinity, due to the separation/elution of free H+ ions. A negative peak was observed from those samples with a free acidity less than their total alkalinity. This was due to an equivalent amount of eluent H+ ions being re-supplied to the stationary phase while the "solid titrant" consumed by the acid-base reaction was regenerated. The retention time for the peak corresponding to the acidity or alkalinity was governed by the retention time for H+ ions in this IC system. Samples with a free acidity greater than 2.25 microM (tested by determination of H+ ions in pure water in equilibrium with atmospheric CO2) could be analyzed by this method. A very similar detection level was obtained for alkalinity (tested by analyzing standard aqueous NaHCO3 solutions). Aqueous solutions of some strong-acid/strong-base inorganic salts were found to be slightly alkaline. This was measured as a percentage, relative to an NaHCO3 solution at the same concentration. Solutions of NaClO4, Na2SO4, NaI, NaNO3, and NaCl, gave comparative alkalinity values of 8.75%, 1.83%, 0.42%, 0.35%, and 0.33%, respectively.

7.
J Wound Care ; 2(5): 255, 1993 Sep 02.
Artigo em Inglês | MEDLINE | ID: mdl-27922358

RESUMO

ALCOHOL-BASED CLEANSING SOLUTIONS STERILE GLOVES PROVIDE WOUND MEASURING GRID JOURNAL POLICY.

8.
Dev Biol ; 112(1): 167-76, 1985 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-3932109

RESUMO

High-affinity uptake systems for amino acid neurotransmitter precursors have been highly correlated with the use of the particular amino acid or its derivative as a transmitter. We have found interneurons in the Xenopus embryo spinal cord which accumulate GABA by a high-affinity uptake system. They originate near the end of gastrulation and their ability to accumulate GABA first appears at the early tail bud stage. By position and appearance they are comparable to some of the embryonic interneurons described by A. Roberts and J. D. W. Clarke (1982, Phil. Trans. R. Soc. London Ser. B 296, 195-212). GABA-accumulating neurons also develop in dissociated cell cultures made from the presumptive spinal cord of neural plate stage Xenopus embryos. GABA accumulation in cultured neurons, as in cells in vivo, occurs via a high-affinity uptake system; GABA-accumulating cells have the same time of origin as the cells in vivo, and the ability to accumulate GABA in the population of cultured neurons appears at a time equivalent to that observed in intact sibling embryos. Thus it seems likely that the population of GABA-accumulating neurons developing in cell culture corresponds to the GABA-accumulating interneurons in vivo. The development of these neurons in dissociated cell cultures permits perturbation experiments that would be difficult to perform in vivo. We have examined the development of high-affinity GABA uptake in conditions that permit no electrical impulse activity in the cultures. The onset and extent of development of GABA accumulation in the neuronal population are normal under these conditions.


Assuntos
Neurônios/metabolismo , Medula Espinal/embriologia , Ácido gama-Aminobutírico/metabolismo , Animais , Células Cultivadas , Meios de Cultura , Ácido Egtázico , Magnésio , Medula Espinal/metabolismo , Tetrodotoxina , Timidina/metabolismo , Fatores de Tempo , Xenopus laevis
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...