Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 63
Filtrar
1.
Opt Quantum ; 2(2): 72-84, 2024 Apr 25.
Artigo em Inglês | MEDLINE | ID: mdl-38741706

RESUMO

In a popular integration process for quantum information technologies, localization microscopy of quantum emitters guides lithographic placement of photonic structures. However, a complex coupling of microscopy and lithography errors degrades registration accuracy, severely limiting device performance and process yield. We introduce a methodology to solve this widespread but poorly understood problem. A new foundation of traceable localization enables rapid characterization of lithographic standards and comprehensive calibration of cryogenic microscopes, revealing and correcting latent systematic effects. Of particular concern, we discover that scale factor deviation and complex optical distortion couple to dominate registration errors. These novel results parameterize a process model for integrating quantum dots and bullseye resonators, predicting higher yield by orders of magnitude, depending on the Purcell factor threshold as a quantum performance metric. Our foundational methodology is a key enabler of the lab-to-fab transition of quantum information technologies and has broader implications to cryogenic and correlative microscopy.

3.
Eur Rev Med Pharmacol Sci ; 26(13): 4809-4815, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-35856373

RESUMO

OBJECTIVE: Acute exacerbations of chronic obstructive pulmonary disease (AECOPDs) accelerate the progressive impairment of lung function and general health. Together with maintenance therapy for chronic obstructive pulmonary disease (COPD), N-acetylcysteine (NAC) and natural propolis have demonstrated pharmacological properties that address crucial pathophysiological processes underlying COPD and may prevent AECOPDs. This study aims at responding to dose-dependent efficacy and safety concerns regarding a propolis-NAC combination for the reduction of COPD exacerbation rates. PATIENTS AND METHODS: This was a single-center, randomized, double-blind, phase IV trial with three treatment arms: Placebo and two active substance groups, one (AS-600) received 600 mg of NAC + 80 mg of propolis while the other (AS-1,200) received 1,200 mg of NAC + 160 mg of propolis. Following an AECOPD, frequent-exacerbation phenotype patients (n=46) were assigned a once-daily three-month therapy with the study drug and one year follow-up. The primary endpoint was the COPD exacerbation incidence rate during the follow-up period as a measure of dose-dependent efficacy of NAC-propolis combination compared to placebo. RESULTS: There was a statistically significant difference in the AECOPD incidence rate: 52.6% in patients that received placebo, 15.4% that received AS-600 and only 7.1% that received AS-1,200 (Fisher's exact test, p = 0.013). Compared to placebo, AECOPD frequency was significantly lower only in AS-1,200 (p=0.009). Compared to placebo, the relative risk for exacerbation was 0.29 in AS-600 and 0.13 in AS-1,200. No adverse events related to the treatment were reported. CONCLUSIONS: Oral combination of natural propolis with NAC confirmed formulation efficiency with a favorable safety profile. Our results need to be confirmed by larger clinical trials.


Assuntos
Própole , Doença Pulmonar Obstrutiva Crônica , Acetilcisteína/efeitos adversos , Progressão da Doença , Método Duplo-Cego , Humanos , Própole/uso terapêutico
4.
Eur Rev Med Pharmacol Sci ; 26(3): 927-934, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-35179759

RESUMO

OBJECTIVE: The pathophysiological mechanisms of idiopathic pulmonary fibrosis (IPF) are not well elucidated. It is assumed that oxidative stress and inflammation are the key underlying culprits for its onset and progression. To gain deeper insight into these processes, we have evaluated several oxidative stress parameters, inflammation markers [i.e., high sensitivity C-reactive protein (hsCRP), serum amyloid A1 (SAA1)], soluble programmed cell death-ligand 1 (sPD-L1), and 25-hydroxyvitamin D [25(OH)D] in IPF patients. PATIENTS AND METHODS: Biochemistry analyses were done in 30 consecutive IPF patients and 30 age and gender-matched healthy control group (CG). RESULTS: IPF patients had significantly higher advanced oxidation protein products (p<0.001), pro-oxidant-antioxidant balance (p=0.010), total oxidative status (p<0.001), and ischemia modified albumin (p<0.001) compared to CG. Lower total antioxidant status and total sulfhydryl groups (tSGH) and significantly higher sPD-L1, hsCRP (p<0.001 for all), SAA1 proteins (p=0.014) and [25(OH)D] severe deficiency [11.0 (9.6-15.1) nmol/L] in IPF patients compared to CG were observed. Paraoxonase 1 activity and hsCRP level were lower, while tSHG and sPD-L1 were higher in IPF patients with more severe disease (i.e., II+III stage compared to I stage, p<0.05 for all). CONCLUSIONS: IPF patients are in a state of profound oxidative stress compared to healthy people. The inflammatory component of the disease was confirmed by higher hsCRP and SAA1, but lower [25(OH)D] in IPF than in healthy people. Also, higher levels of sPD-L1 in patients with IPF compared to healthy individuals suggest that sPD-L1 may have a significant role in immune response in IPF.


Assuntos
Fibrose Pulmonar Idiopática , Biomarcadores , Humanos , Fibrose Pulmonar Idiopática/diagnóstico , Fibrose Pulmonar Idiopática/metabolismo , Inflamação , Estresse Oxidativo , Albumina Sérica/metabolismo
5.
Adv Funct Mater ; 32(38)2022 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-36824209

RESUMO

Focused-ion-beam machining is a powerful process to fabricate complex nanostructures, often through a sacrificial mask that enables milling beyond the resolution limit of the ion beam. However, current understanding of this super-resolution effect is empirical in the spatial domain and nonexistent in the temporal domain. This article reports the primary study of this fundamental tradespace of resolution and throughput. Chromia functions well as a masking material due to its smooth, uniform, and amorphous structure. An efficient method of in-line metrology enables characterization of ion-beam focus by scanning electron microscopy. Fabrication and characterization of complex test structures through chromia and into silica probe the response of the bilayer to a focused beam of gallium cations, demonstrating super-resolution factors of up to 6 ± 2 and improvements to volume throughput of at least factors of 42 ± 2, with uncertainties denoting 95% coverage intervals. Tractable theory models the essential aspects of the super-resolution effect for various nanostructures. Application of the new tradespace increases the volume throughput of machining Fresnel lenses by a factor of 75, enabling the introduction of projection standards for optical microscopy. These results enable paradigm shifts of sacrificial masking from empirical to engineering design and from prototyping to manufacturing.

6.
Anal Chem ; 94(2): 678-686, 2022 01 18.
Artigo em Inglês | MEDLINE | ID: mdl-34927410

RESUMO

Gravimetry typically lacks the resolution to measure single microdroplets, whereas microscopy is often inaccurate beyond the resolution limit. To address these issues, we advance and integrate these complementary methods, introducing simultaneous measurements of the same microdroplets, comprehensive calibrations that are independently traceable to the International System of Units (SI), and Monte-Carlo evaluations of volumetric uncertainty. We achieve sub-picoliter agreement of measurements of microdroplets in flight with volumes of approximately 70 pL, with ensemble gravimetry and optical microscopy both yielding 95% coverage intervals of ±0.6 pL, or relative uncertainties of ±0.9%, and root-mean-square deviations of mean values between the two methods of 0.2 pL or 0.3%. These uncertainties match previous gravimetry results and improve upon previous microscopy results by an order of magnitude. Gravimetry precision depends on the continuity of droplet formation, whereas microscopy accuracy requires that optical diffraction from an edge reference matches that from a microdroplet. Applying our microscopy method, we jet and image water microdroplets suspending fluorescent nanoplastics, count nanoplastic particles after deposition and evaporation, and transfer volumetric traceability to the number concentrations of single microdroplets. We expect that our methods will impact diverse fields involving dimensional metrology and volumetric analysis of microdroplets, including inkjet microfabrication, disease transmission, and industrial sprays.


Assuntos
Microscopia , Água
7.
Nat Commun ; 12(1): 3925, 2021 Jun 24.
Artigo em Inglês | MEDLINE | ID: mdl-34168121

RESUMO

A standard paradigm of localization microscopy involves extension from two to three dimensions by engineering information into emitter images, and approximation of errors resulting from the field dependence of optical aberrations. We invert this standard paradigm, introducing the concept of fully exploiting the latent information of intrinsic aberrations by comprehensive calibration of an ordinary microscope, enabling accurate localization of single emitters in three dimensions throughout an ultrawide and deep field. To complete the extraction of spatial information from microscale bodies ranging from imaging substrates to microsystem technologies, we introduce a synergistic concept of the rigid transformation of the positions of multiple emitters in three dimensions, improving precision, testing accuracy, and yielding measurements in six degrees of freedom. Our study illuminates the challenge of aberration effects in localization microscopy, redefines the challenge as an opportunity for accurate, precise, and complete localization, and elucidates the performance and reliability of a complex microelectromechanical system.

8.
Nat Nanotechnol ; 15(5): 380-389, 2020 05.
Artigo em Inglês | MEDLINE | ID: mdl-32203436

RESUMO

Electronic symmetry breaking by charge disproportionation results in multifaceted changes in the electronic, magnetic and optical properties of a material, triggering ferroelectricity, metal/insulator transition and colossal magnetoresistance. Yet, charge disproportionation lacks technological relevance because it occurs only under specific physical conditions of high or low temperature or high pressure. Here we demonstrate a voltage-triggered charge disproportionation in thin molecular films of a metal-organic complex occurring in ambient conditions. This provides a technologically relevant molecular route for simultaneous realization of a ternary memristor and a binary memcapacitor, scalable down to a device area of 60 nm2. Supported by mathematical modelling, our results establish that multiple memristive states can be functionally non-volatile, yet discrete-a combination perceived as theoretically prohibited. Our device could be used as a binary or ternary memristor, a binary memcapacitor or both concomitantly, and unlike the existing 'continuous state' memristors, its discrete states are optimal for high-density, ultra-low-energy digital computing.

9.
J Res Natl Inst Stand Technol ; 125: 125009, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-35465394

RESUMO

Nanofabrication/characterization facilities enable research and development activities across a host of science and engineering disciplines. The collection of tools and supporting infrastructure necessary to construct, image, and measure micro- and nanoscale materials, devices, and systems is complex and expensive to establish, and it is costly to maintain and optimize. As a result, these facilities are typically operated in a shared-use mode. We discuss the key factors that must be considered to successfully create and sustain such facilities. These include the need for long-term vision and institutional commitment, and the hands-on involvement of managers in facility operations. We consider startup, operating, and recapitalization costs, together with algorithms for cost recovery and tool-time allocation. The acquisition of detailed and comprehensive project and tool-utilization data is essential for understanding and optimizing facility operations. Only such a data-driven decision-making approach can maximize facility impact on institutional goals. We illustrate these concepts using the National Institute of Standards and Technology (NIST) NanoFab as our test case, but the methodologies and resources presented here should be useful to all those faced with this challenging task.

10.
Nat Protoc ; 14(4): 1130-1168, 2019 04.
Artigo em Inglês | MEDLINE | ID: mdl-30903110

RESUMO

Among the different developed solid-state nanopores, nanopores constructed in a monolayer of molybdenum disulfide (MoS2) stand out as powerful devices for single-molecule analysis or osmotic power generation. Because the ionic current through a nanopore is inversely proportional to the thickness of the pore, ultrathin membranes have the advantage of providing relatively high ionic currents at very small pore sizes. This increases the signal generated during translocation of biomolecules and improves the nanopores' efficiency when used for desalination or reverse electrodialysis applications. The atomic thickness of MoS2 nanopores approaches the inter-base distance of DNA, creating a potential candidate for DNA sequencing. In terms of geometry, MoS2 nanopores have a well-defined vertical profile due to their atomic thickness, which eliminates any unwanted effects associated with uneven pore profiles observed in other materials. This protocol details all the necessary procedures for the fabrication of solid-state devices. We discuss different methods for transfer of monolayer MoS2, different approaches for the creation of nanopores, their applicability in detecting DNA translocations and the analysis of translocation data through open-source programming packages. We present anticipated results through the application of our nanopores in DNA translocations and osmotic power generation. The procedure comprises four parts: fabrication of devices (2-3 d), transfer of MoS2 and cleaning procedure (24 h), the creation of nanopores within MoS2 (30 min) and performing DNA translocations (2-3 h). We anticipate that our protocol will enable large-scale manufacturing of single-molecule-analysis devices as well as next-generation DNA sequencing.


Assuntos
Dissulfetos/química , Sequenciamento de Nucleotídeos em Larga Escala/métodos , Microtecnologia/métodos , Molibdênio/química , Nanoporos/ultraestrutura , Nanotecnologia/métodos , DNA/análise , DNA/genética , Diálise/instrumentação , Diálise/métodos , Sequenciamento de Nucleotídeos em Larga Escala/instrumentação , Humanos , Microtecnologia/instrumentação , Nanotecnologia/instrumentação , Imagem Individual de Molécula/instrumentação , Imagem Individual de Molécula/métodos
11.
Rev Sci Instrum ; 89(7): 073902, 2018 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-30068088

RESUMO

We demonstrate the fabrication of ∼1.08 µm deep microfluidic cavities with characteristic size as large as 7 mm × 11 mm or 11 mm diameter, using a silicon-glass anodic bonding technique that does not require posts to act as separators to define cavity height. Since the phase diagram of 3He is significantly altered under confinement, posts might act as pinning centers for phase boundaries. The previous generation of cavities relied on full wafer-bonding which is more prone to failure and requires dicing post-bonding, whereas these cavities are made by bonding a pre-cut piece of Hoya SD-2 glass to a patterned piece of silicon in which the cavity is defined by etching. Anodic bonding was carried out at 425 °C with 200 V, and we observe that pressurizing the cavity to failure (>30 bars pressure) results in glass breaking, rather than the glass-silicon bond separation. In this article, we discuss the detailed fabrication of the cavity, its edges, and details of the junction between the coin silver fill line and the silicon base of the cavity that enables a low internal-friction joint. This feature is important for mass coupling torsional oscillator experimental assays of the superfluid inertial contribution where a high quality factor (Q) improves frequency resolution. The surface preparation that yields well-characterized smooth surfaces to eliminate pinning sites, the use of transparent glass as a cover permitting optical access, low temperature capability, and attachment of pressure-capable ports for fluid access may be features that are important in other applications.

12.
Opt Lett ; 43(12): 2933-2936, 2018 Jun 15.
Artigo em Inglês | MEDLINE | ID: mdl-29905727

RESUMO

We report accurate phase stabilization of an interlocking pair of Kerr-microresonator frequency combs. The two combs, one based on silicon nitride and one on silica, feature nearly harmonic repetition frequencies and can be generated with one laser. The silicon-nitride comb supports an ultrafast-laser regime with three-optical-cycle, 1-picosecond-period soliton pulses and a total dispersive-wave-enhanced bandwidth of 170 THz, while providing a stable phase-link between optical and microwave frequencies. We demonstrate nanofabrication control of the silicon-nitride comb's carrier-envelope offset frequency and spectral profile. The phase-locked combs coherently reproduce their clock with a fractional precision of <6×10-13/τ, a behavior we verified through 2 h of measurement to reach <3×10-16. Our work establishes Kerr combs as a viable technology for applications like optical-atomic timekeeping and optical synchronization.

13.
J Appl Phys ; 123(11)2018 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-29910508

RESUMO

Carbon nanotubes (CNTs) have near unity infrared (IR) absorption efficiency, making them extremely attractive in IR imaging devices. Since CNT growth occurs at elevated temperatures, integration of CNTs with IR imaging devices is challenging and has not yet been achieved. Here we show a strategy for implementing CNTs as IR absorbers using differential heating of thermally-isolated microbolometer membranes in a C2H2 environment. During the process, CNTs were catalytically grown on the surface of a locally-heated membrane while the substrate was maintained at an ambient temperature. CNT growth was monitored in situ in real time using optical microscopy. During growth, we measured the intensity of light emission and the reflected light from the heated microbolometer. Our measurements of bolometer performance show that the CNT layer on the surface of the microbolometer membrane increases the IR response by a factor of (2.3 ± 0.1) (mean ± one standard deviation of the least-squares fit parameters). This work opens the door to integrating near unity IR absorption, CNT-based, IR absorbers with hybrid complementary metal-oxide-semiconductor focal plane array architectures.

14.
Nature ; 557(7703): 81-85, 2018 05.
Artigo em Inglês | MEDLINE | ID: mdl-29695870

RESUMO

Optical-frequency synthesizers, which generate frequency-stable light from a single microwave-frequency reference, are revolutionizing ultrafast science and metrology, but their size, power requirement and cost need to be reduced if they are to be more widely used. Integrated-photonics microchips can be used in high-coherence applications, such as data transmission 1 , highly optimized physical sensors 2 and harnessing quantum states 3 , to lower cost and increase efficiency and portability. Here we describe a method for synthesizing the absolute frequency of a lightwave signal, using integrated photonics to create a phase-coherent microwave-to-optical link. We use a heterogeneously integrated III-V/silicon tunable laser, which is guided by nonlinear frequency combs fabricated on separate silicon chips and pumped by off-chip lasers. The laser frequency output of our optical-frequency synthesizer can be programmed by a microwave clock across 4 terahertz near 1,550 nanometres (the telecommunications C-band) with 1 hertz resolution. Our measurements verify that the output of the synthesizer is exceptionally stable across this region (synthesis error of 7.7 × 10-15 or below). Any application of an optical-frequency source could benefit from the high-precision optical synthesis presented here. Leveraging high-volume semiconductor processing built around advanced materials could allow such low-cost, low-power and compact integrated-photonics devices to be widely used.

15.
J Vib Acoust ; 1402018.
Artigo em Inglês | MEDLINE | ID: mdl-31080325

RESUMO

A large array of elastically coupled micro cantilevers of variable length is studied experimentally and numerically. Full-scale finite element modal analysis is implemented to determine the spectral behavior of the array and to extract a global coupling matrix. A compact reduced order model is used for numerical investigation of the array's dynamic response. Our model results show that at a given excitation frequency within a propagation band, only a finite number of beams respond. Spectral characteristics of individual cantilevers, inertially excited by an external piezoelectric actuator, were measured in vacuum using laser interferometry. The theoretical and experimental results collectively show that the resonant peaks corresponding to individual beams are clearly separated when operating in vacuum at the 3rd harmonic. Distinct resonant peak separation, coupled with the spatially-confined modal response, make higher harmonic operation of tailored, variable-length cantilever arrays well suited for a variety of resonant based sensing applications.

16.
Artigo em Inglês | MEDLINE | ID: mdl-31274970

RESUMO

We report on a flow velocity measurement technique based on snap-through detection of an electrostatically actuated, bistable micromechanical beam. We show that induced elecro-thermal Joule heating and the convective air cooling change the beam curvature and consequently the critical snap-through voltage (VST ). Using single crystal silicon beams, we demonstrate the snap-through voltage to flow velocity sensitivity of dV ST/du ≈ 0.13 V s m -1 with a power consumption of ≈ 360 µ W. Our experimental results were in accord with the reduced order, coupled, thermo-electro-mechanical model prediction. We anticipate that electrostatically induced snap-through in curved, micromechanical beams will open new directions for the design and implementation of downscaled flow sensors for autonomous applications and environmental sensors.

17.
Phys Rev Lett ; 121(26): 264301, 2018 Dec 28.
Artigo em Inglês | MEDLINE | ID: mdl-30636140

RESUMO

We investigate the collective dynamics and nondegenerate parametric resonance (NPR) of coplanar, interdigitated arrays of microcantilevers distinguished by their cantilevers having linearly expanding lengths and thus varying natural frequencies. Within a certain excitation frequency range, the resonators begin oscillating via NPR across the entire array consisting of 200 single-crystal silicon cantilevers. Tunable coupling generated from fringing electrostatic fields provides a mechanism to vary the scope of the NPR. Our experimental results are supported by a reduced-order model that reproduces the leading features of our data including the NPR band. The potential for tailoring the coupled response of suspended mechanical structures using NPR presents new possibilities in mass, force, and energy sensing applications, energy harvesting devices, and optomechanical systems.

18.
Light Sci Appl ; 7: 31, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30839614

RESUMO

The common assumption that precision is the limit of accuracy in localization microscopy and the typical absence of comprehensive calibration of optical microscopes lead to a widespread issue-overconfidence in measurement results with nanoscale statistical uncertainties that can be invalid due to microscale systematic errors. In this article, we report a comprehensive solution to this underappreciated problem. We develop arrays of subresolution apertures into the first reference materials that enable localization errors approaching the atomic scale across a submillimeter field. We present novel methods for calibrating our microscope system using aperture arrays and develop aberration corrections that reach the precision limit of our reference materials. We correct and register localization data from multiple colors and test different sources of light emission with equal accuracy, indicating the general applicability of our reference materials and calibration methods. In a first application of our new measurement capability, we introduce the concept of critical-dimension localization microscopy, facilitating tests of nanofabrication processes and quality control of aperture arrays. In a second application, we apply these stable reference materials to answer open questions about the apparent instability of fluorescent nanoparticles that commonly serve as fiducial markers. Our study establishes a foundation for subnanometer localization accuracy in widefield optical microscopy.

19.
Phys Rev B ; 972018.
Artigo em Inglês | MEDLINE | ID: mdl-30997441

RESUMO

Topological effects typically discussed in the context of quantum physics are emerging as one of the central paradigms of physics. Here, we demonstrate the role of topology in energy transport through dimerized micro- and nano-mechanical lattices in the classical regime, i.e., essentially "masses and springs". We show that the thermal conductance factorizes into topological and nontopological components. The former takes on three discrete values and arises due to the appearance of edge modes that prevent good contact between the heat reservoirs and the bulk, giving a length-independent reduction of the conductance. In essence, energy input at the boundary mostly stays there, an effect robust against disorder and nonlinearity. These results bridge two seemingly disconnected disciplines of physics, namely topology and thermal transport, and suggest ways to engineer thermal contacts, opening a direction to explore the ramifications of topological properties on nanoscale technology.

20.
Phys Rev Appl ; 72017 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-28580373

RESUMO

Acoustic wave devices provide a promising chip-scale platform for efficiently coupling radio frequency (RF) and optical fields. Here, we use an integrated piezo-optomechanical circuit platform that exploits both the piezoelectric and photoelastic coupling mechanisms to link 2.4 GHz RF waves to 194 THz (1550 nm) optical waves, through coupling to propagating and localized 2.4 GHz acoustic waves. We demonstrate acousto-optic modulation, resonant in both the optical and mechanical domains, in which waveforms encoded on the RF carrier are mapped to the optical field. We also show opto-acoustic gating, in which the application of modulated optical pulses interferometrically gates the transmission of propagating acoustic pulses. The time-domain characteristics of this system under both pulsed RF and pulsed optical excitation are considered in the context of the different physical pathways involved in driving the acoustic waves, and modelled through the coupled mode equations of cavity optomechanics.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...