Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 18 de 18
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
2.
Prog Orthod ; 23(1): 11, 2022 Apr 04.
Artigo em Inglês | MEDLINE | ID: mdl-35368222

RESUMO

BACKGROUND: Mini-screws are widely used as temporary anchorages in orthodontic treatment, but have the disadvantage of showing a high failure rate of about 10%. Therefore, orthodontic mini-screws should have high biocompatibility and retention. Previous studies have demonstrated that the retention of mini-screws can be improved by imparting bioactivity to the surface. The method for imparting bioactivity proposed in this paper is to sequentially perform anodization, periodic pre-calcification, and heat treatments with a Ti-6Al-4V ELI alloy mini-screw. MATERIALS AND METHODS: A TiO2 nanotube-structured layer was formed on the surface of the Ti-6Al-4V ELI alloy mini-screw through anodization in which a voltage of 20 V was applied to a glycerol solution containing 20 wt% H2O and 1.4 wt% NH4F for 60 min. Fine granular calcium phosphate precipitates of HA and octacalcium phosphate were generated as clusters on the surface through the cyclic pre-calcification and heat treatments. The cyclic pre-calcification treatment is a process of immersion in a 0.05 M NaH2PO4 solution and a saturated Ca(OH)2 solution at 90 °C for 1 min each. RESULTS: It was confirmed that the densely structured protrusions were precipitated, and Ca and P concentrations, which bind and concentrate endogenous bone morphogenetic proteins, increased on the surface after simulated body fluid (SBF) immersion test. In addition, the removal torque of the mini-screw fixed into rabbit tibias for 4 weeks was measured to be 8.70 ± 2.60 N cm. CONCLUSIONS: A noteworthy point in this paper is that the Ca and P concentrations, which provide a scaffold suitable for endogenous bone formation, further increased over time after SBF immersion of the APH group specimens. The other point is that our mini-screws have a significantly higher removal torque compared to untreated mini-screws. These results represent that the mini-screw proposed in this paper can be used as a mini-screw for orthodontics.


Assuntos
Temperatura Alta , Osseointegração , Ligas , Animais , Materiais Biocompatíveis , Parafusos Ósseos , Humanos , Coelhos , Titânio
3.
Biosens Bioelectron ; 197: 113782, 2022 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-34814029

RESUMO

Rodents have a well-developed sense of smell and are used to detect explosives, mines, illegal substances, hidden currency, and contraband, but it is impossible to keep their concentration constantly. Therefore, there is an ongoing effort to infer odors detected by animals without behavioral readings with brain-computer interface (BCI) technology. However, the invasive BCI technique has the disadvantage that long-term studies are limited by the immune response and electrode movement. On the other hand, near-infrared spectroscopy (NIRS)-based BCI technology is a non-invasive method that can measure neuronal activity without worrying about the immune response or electrode movement. This study confirmed that the NIRS-based BCI technology can be used as an odor detection and identification from the rat olfactory system. In addition, we tried to present features optimized for machine learning models by extracting six features, such as slopes, peak, variance, mean, kurtosis, and skewness, from the hemodynamic response, and analyzing the importance of individuals or combinations. As a result, the feature with the highest F1-Score was indicated as slopes, and it was investigated that the combination of the features including slopes and mean was the most important for odor inference. On the other hand, the inclusion of other features with a low correlation with slopes had a positive effect on the odor inference, but most of them resulted in insignificant or rather poor performance. The results presented in this paper are expected to serve as a basis for suggesting the development direction of the hemodynamic response-based bionic nose in the future.


Assuntos
Técnicas Biossensoriais , Bulbo Olfatório , Animais , Hemodinâmica , Aprendizado de Máquina , Odorantes , Ratos , Olfato
4.
JMIR Mhealth Uhealth ; 8(10): e17881, 2020 10 16.
Artigo em Inglês | MEDLINE | ID: mdl-33064097

RESUMO

BACKGROUND: Dental diseases can be prevented through the management of dental plaques. Dental plaque can be identified using the light-induced fluorescence (LIF) technique that emits light at 405 nm. The LIF technique is more convenient than the commercial technique using a disclosing agent, but the result may vary for each individual as it still requires visual identification. OBJECTIVE: The objective of this study is to introduce and validate a deep learning-based oral hygiene monitoring system that makes it easy to identify dental plaques at home. METHODS: We developed a LIF-based system consisting of a device that can visually identify dental plaques and a mobile app that displays the location and area of dental plaques on oral images. The mobile app is programmed to automatically determine the location and distribution of dental plaques using a deep learning-based algorithm and present the results to the user as time series data. The mobile app is also built with convergence of naive and web applications so that the algorithm is executed on a cloud server to efficiently distribute computing resources. RESULTS: The location and distribution of users' dental plaques could be identified via the hand-held LIF device or mobile app. The color correction filter in the device was developed using a color mixing technique. The mobile app was built as a hybrid app combining the functionalities of a native application and a web application. Through the scrollable WebView on the mobile app, changes in the time series of dental plaque could be confirmed. The algorithm for dental plaque detection was implemented to run on Amazon Web Services for object detection by single shot multibox detector and instance segmentation by Mask region-based convolutional neural network. CONCLUSIONS: This paper shows that the system can be used as a home oral care product for timely identification and management of dental plaques. In the future, it is expected that these products will significantly reduce the social costs associated with dental diseases.


Assuntos
Aplicativos Móveis , Algoritmos , Fluorescência , Humanos , Higiene Bucal
5.
Polymers (Basel) ; 11(9)2019 Sep 02.
Artigo em Inglês | MEDLINE | ID: mdl-31480664

RESUMO

Polymer-based micro-electrode arrays (MEAs) are gaining attention as an essential technology to understand brain connectivity and function in the field of neuroscience. However, polymer based MEAs may have several challenges such as difficulty in performing the etching process, difficulty of micro-pattern generation through the photolithography process, weak metal adhesion due to low surface energy, and air pocket entrapment over the electrode site. In order to compensate for the challenges, this paper proposes a novel MEA fabrication process that is performed sequentially with (1) silicon mold preparation; (2) PDMS replica molding, and (3) metal patterning and parylene insulation. The MEA fabricated through this process possesses four arms with electrode sites on the convex microstructures protruding about 20 µm from the outermost layer surface. The validity of the convex microstructure implementation is demonstrated through theoretical background. The electrochemical impedance magnitude is 204.4 ± 68.1 kΩ at 1 kHz. The feasibility of the MEA with convex microstructures was confirmed by identifying the oscillation in the beta frequency band (13-30 Hz) in the electrocorticography signal of a rat olfactory bulb during respiration. These results suggest that the MEA with convex microstructures is promising for applying to various neural recording and stimulation studies.

6.
PLoS One ; 13(2): e0192629, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29438432

RESUMO

Although several studies have been performed to detect cancer using canine olfaction, none have investigated whether canine olfaction trained to the specific odor of one cancer is able to detect odor related to other unfamiliar cancers. To resolve this issue, we employed breast and colorectal cancer in vitro, and investigated whether trained dogs to odor related to metabolic waste from breast cancer are able to detect it from colorectal cancer, and vice versa. The culture liquid samples used in the cultivation of cancerous cells (4T1 and CT26) were employed as an experimental group. Two different breeds of dogs were trained for the different cancer odor each other. The dogs were then tested using a double-blind method and cross-test to determine whether they could correctly detect the experimental group, which contains the specific odor for metabolic waste of familiar or unfamiliar cancer. For two cancers, both dogs regardless of whether training or non-training showed that accuracy was over 90%, and sensitivity and specificity were over 0.9, respectively. Through these results, it was verified that the superior olfactory ability of dogs can discriminate odor for metabolic waste of cancer cells from it of benign cells, and that the specific odor for metabolic waste of breast cancer has not significant differences to it of colorectal cancer. That is, it testifies that metabolic waste between breast and colorectal cancer have the common specific odor in vitro. Accordingly, a trained dogs for detecting odor for metabolic waste of breast cancer can perceive it of colorectal cancer, and vice versa. In order to the future work, we will plan in vivo experiment for the two cancers and suggest research as to what kind of cancers have the common specific odor. Furthermore, the relationship between breast and colorectal cancer should be investigated using other research methods.


Assuntos
Neoplasias da Mama/diagnóstico , Neoplasias Colorretais/diagnóstico , Cães/fisiologia , Odorantes , Olfato , Animais , Neoplasias da Mama/metabolismo , Linhagem Celular Tumoral , Neoplasias Colorretais/metabolismo , Feminino , Humanos , Masculino
7.
J Biophotonics ; 11(3)2018 03.
Artigo em Inglês | MEDLINE | ID: mdl-29215208

RESUMO

In this study, we introduce the novel image-guided recording system (IGRS) for efficient interpretation of neuronal activities in the brain slice. IGRS is designed to combine microelectrode array (MEA) and optical coherence tomography at the customized upright microscope. It allows to record multi-site neuronal signals and image of the volumetric brain anatomy in a single body configuration. For convenient interconnection between a brain image and neuronal signals, we developed the automatic mapping protocol that enables us to project acquired neuronal signals on a brain image. To evaluate the performance of IGRS, hippocampal signals of the brain slice were monitored, and corresponding with two-dimensional neuronal maps were successfully reconstructed. Our results indicated that IGRS and mapping protocol can provide the intuitive information regarding long-term and multi-sites neuronal signals. In particular, the temporal and spatial mapping capability of neuronal signals would be a very promising tool to observe and analyze the massive neuronal activity and connectivity in MEA-based electrophysiological studies.


Assuntos
Encéfalo/citologia , Encéfalo/diagnóstico por imagem , Eletrofisiologia/instrumentação , Neurônios/citologia , Tomografia de Coerência Óptica , Animais , Encéfalo/fisiologia , Espaço Extracelular/metabolismo , Processamento de Imagem Assistida por Computador , Camundongos , Camundongos Endogâmicos C57BL , Microeletrodos , Análise Espaço-Temporal
8.
Nat Commun ; 8(1): 1664, 2017 11 21.
Artigo em Inglês | MEDLINE | ID: mdl-29162854

RESUMO

Soft bioelectronic devices provide new opportunities for next-generation implantable devices owing to their soft mechanical nature that leads to minimal tissue damages and immune responses. However, a soft form of the implantable optoelectronic device for optical sensing and retinal stimulation has not been developed yet because of the bulkiness and rigidity of conventional imaging modules and their composing materials. Here, we describe a high-density and hemispherically curved image sensor array that leverages the atomically thin MoS2-graphene heterostructure and strain-releasing device designs. The hemispherically curved image sensor array exhibits infrared blindness and successfully acquires pixelated optical signals. We corroborate the validity of the proposed soft materials and ultrathin device designs through theoretical modeling and finite element analysis. Then, we propose the ultrathin hemispherically curved image sensor array as a promising imaging element in the soft retinal implant. The CurvIS array is applied as a human eye-inspired soft implantable optoelectronic device that can detect optical signals and apply programmed electrical stimulation to optic nerves with minimum mechanical side effects to the retina.


Assuntos
Dissulfetos/química , Desenho de Equipamento/métodos , Grafite/química , Molibdênio/química , Transistores Eletrônicos , Próteses Visuais , Algoritmos , Animais , Desenho de Equipamento/instrumentação , Humanos , Masculino , Modelos Teóricos , Estimulação Luminosa , Ratos Wistar , Retina/fisiologia , Visão Ocular/fisiologia
9.
Sci Rep ; 7(1): 8083, 2017 08 14.
Artigo em Inglês | MEDLINE | ID: mdl-28808270

RESUMO

A novel three dimensional blood brain barrier (BBB) platform was developed by independently supplying different types of media to separate cell types within a single device. One channel (vascular channel, VC) is connected to the inner lumen of the vascular network while the other supplies media to the neural cells (neural channel, NC). Compared to co-cultures supplied with only one type of medium (or 1:1 mixture), best barrier properties and viability were obtained with culturing HUVECs with endothelial growth medium (EGM) and neural cells with neurobasal medium supplemented with fetal bovine serum (NBMFBS) independently. The measured vascular network permeability were comparable to reported in vivo values (20 kDa FITC-dextran, 0.45 ± 0.11 × 10-6 cm/s; 70 kDa FITC-dextran, 0.36 ± 0.05 × 10-6 cm/s) and a higher degree of neurovascular interfacing (astrocytic contact with the vascular network, GFAP-CD31 stain overlap) and presence of synapses (stained with synaptophysin). The BBB platform can dependably imitate the perivascular network morphology and synaptic structures characteristic of the NVU. This microfluidic BBB model can find applications in screening pharmaceuticals that target the brain for in neurodegenerative diseases.


Assuntos
Astrócitos/fisiologia , Barreira Hematoencefálica/fisiologia , Permeabilidade Capilar/fisiologia , Animais , Transporte Biológico/fisiologia , Encéfalo/fisiologia , Linhagem Celular , Permeabilidade da Membrana Celular/fisiologia , Técnicas de Cocultura/métodos , Células Endoteliais/fisiologia , Células Endoteliais da Veia Umbilical Humana , Humanos , Técnicas Analíticas Microfluídicas/métodos , Microfluídica/métodos , Neurônios/fisiologia , Ratos , Ratos Sprague-Dawley
10.
Polymers (Basel) ; 9(12)2017 Dec 08.
Artigo em Inglês | MEDLINE | ID: mdl-30965988

RESUMO

Conventional polymer multielectrode arrays (MEAs) have limitations resulting from a high Young's modulus, including low conformability and gaps between the electrodes and neurons. These gaps are not a problem in soft tissues such as the brain, due to the repopulation phenomenon. However, gaps can result in signal degradation when recording from a fiber bundle, such as the spinal cord. Methods: We propose a method for fabricating flexible polydimethylsiloxane (PDMS)-based MEAs featuring plateau-shaped microelectrodes. The proposed fabrication technique enables the electrodes on the surface of MEAs to make a tight connection to the neurons, because the wire of the MEA is fabricated to be plateau-shaped, as the Young's modulus of PDMS is similar to soft tissues and PDMS follows the curvature of the neural tissue due to its high conformability compared to the other polymers. Injury caused by the movement of the MEAs can therefore be minimized. Each electrode has a diameter of 130 µm and the 8-channel array has a center-to-center electrode spacing of 300 µm. The signal-to-noise ratio of the plateau-shaped electrodes was larger than that of recessed electrodes because there was no space between the electrode and neural cell. Reliable neural recordings were possible by adjusting the position of the electrode during the experiment without trapping air under the electrodes. Simultaneous multi-channel neural recordings were successfully achieved from the spinal cord of rodents. We describe the fabrication technique, electrode 3D profile, electrode impedance, and MEA performance in in vivo experiments in rodents.

11.
J Neural Eng ; 13(5): 056005, 2016 10.
Artigo em Inglês | MEDLINE | ID: mdl-27526398

RESUMO

Chronic monitoring of intravesical pressure is required to detect the onset of intravesical hypertension and the progression of a more severe condition. Recent reports demonstrate the bladder state can be monitored from the spiking activity of the dorsal root ganglia or lumbosacral spinal cord. However, one of the most serious challenges for these methods is the difficulty of sustained spike signal acquisition due to the high-electrode-location-sensitivity of spikes or neuro-degeneration. Alternatively, it has been demonstrated that local field potential recordings are less affected by encapsulation reactions or electrode location changes. Here, we hypothesized that local field potential (LFP) from the lumbosacral dorsal horn may provide information concerning the intravesical pressure. LFP and spike activities were simultaneously recorded from the lumbosacral spinal cord of anesthetized rats during bladder filling. The results show that the LFP activities carry significant information about intravesical pressure along with spiking activities. Importantly, the intravesical pressure is decoded from the power in high-frequency bands (83.9-256 Hz) with a substantial performance similar to that of the spike train decoding. These findings demonstrate that high-frequency LFP activity can be an alternative intravesical pressure monitoring signal, which could lead to a proper closed loop system for urinary control.


Assuntos
Potenciais de Ação/fisiologia , Região Lombossacral/fisiologia , Monitorização Fisiológica/instrumentação , Monitorização Fisiológica/métodos , Medula Espinal/fisiologia , Bexiga Urinária/fisiologia , Algoritmos , Anestesia , Animais , Eletrodos , Feminino , Gânglios Espinais/fisiologia , Próteses Neurais , Pressão , Ratos , Ratos Sprague-Dawley , Bexiga Urinária/inervação
12.
Biomed Opt Express ; 7(4): 1614-25, 2016 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-27446678

RESUMO

Despite a potential of infrared neural stimulation (INS) for modulating neural activities, INS suffers from limited light confinement and bulk tissue heating. Here, a novel methodology for an advanced optical stimulation is proposed by combining near-infrared (NIR) stimulation with gold nanorods (GNRs) targeted to neuronal cell membrane. We confirmed experimentally that in vitro and in vivo neural activation is associated with a local heat generation based on NIR stimulation and GNRs. Compared with the case of NIR stimulation without an aid of GNRs, combination with cell-targeted GNRs allows photothermal stimulation with faster neural response, lower delivered energy, higher stimulation efficiency and stronger behavior change. Since the suggested method can reduce a requisite radiant exposure level and alleviate a concern of tissue damage, it is expected to open up new possibilities for applications to optical neuromodulations for diverse excitable tissues and treatments of neurological disorders.

13.
J Neural Eng ; 10(5): 056009, 2013 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-23928663

RESUMO

OBJECTIVE: Chronic monitoring of the state of the bladder can be used to notify patients with urinary dysfunction when the bladder should be voided. Given that many spinal neurons respond both to somatic and visceral inputs, it is necessary to extract bladder information selectively from the spinal cord. Here, we hypothesize that sensory information with distinct modalities should be represented by the distinct ensemble activity patterns within the neuronal population and, therefore, analyzing the activity patterns of the neuronal population could distinguish bladder fullness from somatic stimuli. APPROACH: We simultaneously recorded 26-27 single unit activities in response to bladder distension or tactile stimuli in the dorsal spinal cord of each Sprague-Dawley rat. In order to discriminate between bladder fullness and tactile stimulus inputs, we analyzed the ensemble activity patterns of the entire neuronal population. A support vector machine (SVM) was employed as a classifier, and discrimination performance was measured by k-fold cross-validation tests. MAIN RESULTS: Most of the units responding to bladder fullness also responded to the tactile stimuli (88.9-100%). The SVM classifier precisely distinguished the bladder fullness from the somatic input (100%), indicating that the ensemble activity patterns of the unit population in the spinal cord are distinct enough to identify the current input modality. Moreover, our ensemble activity pattern-based classifier showed high robustness against random losses of signals. SIGNIFICANCE: This study is the first to demonstrate that the two main issues of electroneurographic monitoring of bladder fullness, low signals and selectiveness, can be solved by an ensemble activity pattern-based approach, improving the feasibility of chronic monitoring of bladder fullness by neural recording.


Assuntos
Medula Espinal/fisiologia , Bexiga Urinária/fisiologia , Algoritmos , Animais , Interpretação Estatística de Dados , Fenômenos Eletrofisiológicos/fisiologia , Feminino , Modelos Lineares , Estimulação Física , Ratos , Ratos Sprague-Dawley , Reprodutibilidade dos Testes , Sensação/fisiologia , Medula Espinal/citologia , Máquina de Vetores de Suporte , Bexiga Urinária/inervação , Micção
14.
Korean J Physiol Pharmacol ; 17(4): 299-306, 2013 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-23946689

RESUMO

Deep brain stimulation (DBS) of the subthalamic nucleus (STN) has been widely used as a treatment for the movement disturbances caused by Parkinson's disease (PD). Despite successful application of DBS, its mechanism of therapeutic effect is not clearly understood. Because PD results from the degeneration of dopamine neurons that affect the basal ganglia (BG) network, investigation of neuronal responses of BG neurons during STN DBS can provide informative insights for the understanding of the mechanism of therapeutic effect. However, it is difficult to observe neuronal activity during DBS because of large stimulation artifacts. Here, we report the observation of neuronal activities of the globus pallidus (GP) in normal and PD model rats during electrical stimulation of the STN. A custom artifact removal technique was devised to enable monitoring of neural activity during stimulation. We investigated how GP neurons responded to STN stimulation at various stimulation frequencies (10, 50, 90 and 130 Hz). It was observed that activities of GP neurons were modulated by stimulation frequency of the STN and significantly inhibited by high frequency stimulation above 50 Hz. These findings suggest that GP neuronal activity is effectively modulated by STN stimulation and strongly dependent on the frequency of stimulation.

15.
IEEE Trans Biomed Eng ; 59(7): 2085-94, 2012 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-22718688

RESUMO

We proposed a method of making a flexible depth-type neural probe using liquid crystal polymer. Conventional depth neural probes made of metal or silicon have the limitations of a single recording site per shank or the brittleness of the silicon substrate. To avoid these drawbacks, polymer-based depth neural probes have been developed with biocompatible polymers such as polyimides or parylenes. However, those have suffered from the difficulty of inserting the probes into brain tissues due to their high flexibility, requiring mechanical reinforcements. Herein, we report the first attempt to use a flexible material, liquid crystal polymer (LCP), as a substrate for a depth-type neural probe. The LCP-based probe offers a controllable stiffness vs. flexibility and compatibility with thin-film processes in addition to its inherent characteristics such as high reliability and biocompatibility. In the present study, an LCP neural probe was fabricated to have enough stiffness to penetrate the dura mater of rodent brains without a guide tool or additional reinforcement structures. A simultaneous multichannel neural recording was successfully achieved from the somatosensory motor cortex of the rodents. Immunohistochemistry showed that the electrodes could be inserted into the desired regions in the brain.


Assuntos
Encéfalo/fisiologia , Encéfalo/cirurgia , Eletrodos Implantados , Neurônios/fisiologia , Procedimentos Neurocirúrgicos/instrumentação , Polímeros/química , Animais , Ratos , Ratos Sprague-Dawley , Processamento de Sinais Assistido por Computador , Silício/química
16.
Neurosci Lett ; 505(2): 113-8, 2011 Nov 14.
Artigo em Inglês | MEDLINE | ID: mdl-22005581

RESUMO

The purpose of this study was to identify consistent characteristic changes of neuronal activity in basal ganglia (BG) nuclei associated with Parkinson's disease (PD) so that a reliable index of PD can be derived. A simple algorithm for automatic identification of firing patterns was devised as an essential tool to achieve this goal. A detailed quantitative analysis of firing patterns as well as firing rate was performed in three BG nuclei: the subthalamic nucleus (STN), the substantia nigra pars reticulate (SNpr), and the globus pallidus (GP). The results showed that the firing rate of STN neurons was not significantly altered in PD model rats. We also did not find a significant alteration in firing rates in the SNpr and GP between normal and PD model rats. In contrast, consistent changes of firing patterns were observed in all three BG nuclei in that the percentage of neurons with a regular firing pattern decreased whereas those with irregular, mixed, or burst patterns increased. This enables a simple algorithm based on burst detection and the shape of the interspike interval histogram to identify whether the neuronal activity is from normal or PD model rats.


Assuntos
Potenciais de Ação/fisiologia , Neurônios/fisiologia , Transtornos Parkinsonianos/patologia , Transtornos Parkinsonianos/fisiopatologia , Animais , Globo Pálido/patologia , Globo Pálido/fisiopatologia , Masculino , Neurônios/patologia , Oxidopamina/toxicidade , Transtornos Parkinsonianos/diagnóstico , Ratos , Ratos Sprague-Dawley , Substância Negra/patologia , Substância Negra/fisiopatologia , Núcleo Subtalâmico/patologia , Núcleo Subtalâmico/fisiopatologia
17.
IEEE Trans Biomed Eng ; 58(5): 1208-15, 2011 May.
Artigo em Inglês | MEDLINE | ID: mdl-21193366

RESUMO

This paper presents a novel method for inferring the odor based on neural activities observed from rats' main olfactory bulbs. Multichannel extracellular single unit recordings were done by microwire electrodes (tungsten, 50 µm, 32 channels) implanted in the mitral/tufted cell layers of the main olfactory bulb of anesthetized rats to obtain neural responses to various odors. Neural response as a key feature was measured by subtraction of neural firing rate before stimulus from after. For odor inference, we have developed a decoding method based on the maximum likelihood estimation. The results have shown that the average decoding accuracy is about 100.0%, 96.0%, 84.0%, and 100.0% with four rats, respectively.


Assuntos
Eletroencefalografia/métodos , Odorantes , Bulbo Olfatório/fisiologia , Processamento de Sinais Assistido por Computador , Algoritmos , Animais , Eletrodos Implantados , Eletroencefalografia/instrumentação , Potenciais Evocados/fisiologia , Masculino , Modelos Estatísticos , Compostos Orgânicos , Ratos , Ratos Sprague-Dawley , Olfato/fisiologia
18.
Exp Neurobiol ; 20(4): 189-96, 2011 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-22355264

RESUMO

In this study, we characterize the hemodynamic changes in the main olfactory bulb of anesthetized Sprague-Dawley (SD) rats with near-infrared spectroscopy (NIRS, ISS Imagent) during presentation of two different odorants. Odorants were presented for 10 seconds with clean air via an automatic odor stimulator. Odorants are: (i) plain air as a reference (Blank), (ii) 2-Heptanone (HEP), (iii) Isopropylbenzene (IB). Our results indicated that a plain air did not cause any change in the concentrations of oxygenated (Δ[HbO(2)]) and deoxygenated hemoglobin (Δ[Hbr]), but HEP and IB induced strong changes. Furthermore, these odor-specific changes had regional differences within the MOB. Our results suggest that NIRS technology might be a useful tool to identify of various odorants in a non-invasive manner using animals which has a superb olfactory system.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...