Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Artigo em Japonês | MEDLINE | ID: mdl-36560902

RESUMO

We compared rapid antigen detection kits widely used for the rapid diagnosis of group A streptococcal pharyngitis, evaluating their minimum detection sensitivity and operability in five levels. Five kits based on the immunochromatographic method were used: ImunoAce Strep A (Tauns), ImunoAce Strep A Neo (Tauns), Quick Navi-StrepA2 (Denka), Quick Vue Dipstick Strep A (SB Bioscience) and RapidTesta Strep A (SEKISUI MEDICAL). Thirteen strains were tested: 10 clinical isolates of Streptococcus pyogenes, 2 strains of Streptococcus dysgalactiae subsp. equisimilis (SDSE), and S. pyogenes ATCC 19615. All kits had the same or higher minimum detection sensitivity than previously reported. ImunoAce StrepA Neo had the highest detection sensitivity and the best overall evaluation among the group A streptococcal rapid antigen detection kits used in this study. The detection sensitivity of SDSE with group A polysaccharide antigen was comparable to that of S. pyogenes. Although culture tests are necessary to confirm the causative organism, SDSE may present with clinical symptoms similar to those of S. pyogenes, and detection with a rapid antigen detection kit may be of therapeutic value.


Assuntos
Faringite , Infecções Estreptocócicas , Humanos , Streptococcus pyogenes , Infecções Estreptocócicas/diagnóstico , Faringite/diagnóstico , Faringite/microbiologia , Kit de Reagentes para Diagnóstico
2.
J Clin Monit Comput ; 20(5): 317-27, 2006 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-16941072

RESUMO

OBJECTIVES: The purpose of this study was to develop an interactive software package of alarm sounds to present, recognize and share problems about alarm sounds among medical staff and medical manufactures. METHODS: The alarm sounds were recorded in variable alarm conditions in a WAV file. The alarm conditions were arbitrarily induced by modifying attachments of various medical devices. The software package that integrated an alarm sound database and simulator was used to assess the ability to identify the monitor that sounded the alarm for the medical staff. RESULTS: Eighty alarm sound files (40MB in total) were recorded from 41 medical devices made by 28 companies. There were three pairs of similar alarm sounds that could not easily be distinguished, two alarm sounds which had a different priority, either low or high. The alarm sound database was created in an Excel file (ASDB.xls 170 kB, 40 MB with photos), and included a list of file names that were hyperlinked to alarm sound files. An alarm sound simulator (AlmSS) was constructed with two modules for simultaneously playing alarm sound files and for designing new alarm sounds. The AlmSS was used in the assessing procedure to determine whether 19 clinical engineers could identify 13 alarm sounds only by their distinctive sounds. They were asked to choose from a list of devices and to rate the priority of each alarm. The overall correct identification rate of the alarm sounds was 48%, and six characteristic alarm sounds were correctly recognized by beetween 63% to 100% of the subjects. The overall recognition rate of the alarm sound priority was only 27%. CONCLUSIONS: We have developed an interactive software package of alarm sounds by integrating the database and the alarm sound simulator (URL: http://info.ahs.kitasato-u.ac.jp/tkweb/alarm/asdb.html ). The AlmSS was useful for replaying multiple alarm sounds simultaneously and designing new alarm sounds interactively.


Assuntos
Bases de Dados Factuais , Monitorização Fisiológica , Software , Som , Engenharia Biomédica , Falha de Equipamento , Humanos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...