Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Anal Sci ; 2024 May 10.
Artigo em Inglês | MEDLINE | ID: mdl-38727930

RESUMO

Analyzing pharmaceutical products is a quality control requirement in a production facility. This study presents a CuO electrode-based reusable non-enzymatic sensor as an alternative method for rapid analysis of glucose levels in glucose infusions. CuO is extensively employed as an electrode material in non-enzymatic glucose sensors. Conventionally, these electrodes are fabricated using chemical synthesis of CuO followed by immobilization to the electrode substrate. In contrast, here, Cu metal was mechanically modified to create a grooved surface, followed by electrochemical anodization and subsequent annealing process to grow a seamless CuO layer in situ with enhanced catalytic activity. The morphology of the electrodes was characterized using scanning electron microscopy (SEM) and X-ray diffractometry (XRD). The direct electrocatalytic activity of the developed CuO-modified electrode towards glucose oxidation in alkaline media was investigated by cyclic voltammetry in detail. The CuO-modified electrode commenced the oxidation process around 0.10 V vs. Ag pseudo-reference electrode, demonstrating a significant reduction in the overvoltage for glucose oxidation compared to the bare Cu electrode. The sensor is capable of detecting glucose at low oxidation potentials such as 0.2 V with a sensitivity value of 0.37 µA ppm-1, a wide linear range (80-2300 ppm), limit of quantification (LOQ) of 1 ppm, greater repeatability, 1% precision, 3% bias, a short response time (80 s), good reproducibility and excellent reusability (196 consecutive attempts). The enhanced performance and cost-effectiveness make this sensor a promising alternative method for product analysis in glucose injection solutions.

2.
RSC Adv ; 13(10): 6396-6411, 2023 Feb 21.
Artigo em Inglês | MEDLINE | ID: mdl-36845598

RESUMO

This work presents a highly sensitive, economical, flexible, and disposable humidity sensor developed with a facile fabrication process. The sensor was fabricated on cellulose paper using polyemaraldine salt, a form of polyaniline (PAni), via the drop coating method. A three-electrode configuration was employed to ensure high accuracy and precision. The PAni film was characterized using various techniques including ultraviolet-visible (UV-vis) absorption spectroscopy, Fourier transform infrared spectroscopy (FTIR), X-ray diffraction (XRD) and scanning electron microscopy (SEM). The humidity sensing properties were evaluated through electrochemical impedance spectroscopy (EIS) in a controlled environment. The sensor exhibits a linear response with R 2 = 0.990 for impedance over a wide range of (0%-97%) relative humidity (RH). Further, it displayed consistent responsiveness, a sensitivity of 1.1701 Ω/%RH, acceptable response (≤220 s)/recovery (≤150 s), excellent repeatability, low hysteresis (≤2.1%) and long-term stability at room temperature. The temperature dependence of the sensing material was also studied. Due to its unique features, cellulose paper was found to be an effective alternative to conventional sensor substrates according to several factors including compatibility with the PAni layer, flexibility and low cost. These unique characteristics make this sensor a promising option for use in specific healthcare monitoring, research activities, and industrial settings as a flexible and disposable humidity measurement tool.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...