Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
PLoS Biol ; 16(5): e2004786, 2018 05.
Artigo em Inglês | MEDLINE | ID: mdl-29723197

RESUMO

Clathrin-mediated endocytosis (CME) proceeds through a series of morphological changes of the plasma membrane induced by a number of protein components. Although the spatiotemporal assembly of these proteins has been elucidated by fluorescence-based techniques, the protein-induced morphological changes of the plasma membrane have not been fully clarified in living cells. Here, we visualize membrane morphology together with protein localizations during CME by utilizing high-speed atomic force microscopy (HS-AFM) combined with a confocal laser scanning unit. The plasma membrane starts to invaginate approximately 30 s after clathrin starts to assemble, and the aperture diameter increases as clathrin accumulates. Actin rapidly accumulates around the pit and induces a small membrane swelling, which, within 30 s, rapidly covers the pit irreversibly. Inhibition of actin turnover abolishes the swelling and induces a reversible open-close motion of the pit, indicating that actin dynamics are necessary for efficient and irreversible pit closure at the end of CME.


Assuntos
Vesículas Revestidas por Clatrina/fisiologia , Endocitose , Actinas/metabolismo , Animais , Células COS , Chlorocebus aethiops , Dinaminas/metabolismo , Microscopia de Força Atômica , Microscopia Confocal
2.
Sci Rep ; 7(1): 6462, 2017 07 25.
Artigo em Inglês | MEDLINE | ID: mdl-28743939

RESUMO

The use of cryosectioning facilitates the morphological analysis and immunocytochemistry of cells in tissues in atomic force microscopy (AFM). The cantilever can access all parts of a tissue sample in cryosections after the embedding medium (sucrose) has been replaced with phosphate-buffered saline (PBS), and this approach has enabled the production of a type of high-resolution image. The images resembled those obtained from freeze-etching replica electron microscopy (EM) rather than from thin-section EM. The AFM images showed disks stacked and enveloped by the cell membrane in rod photoreceptor outer segments (ROS) at EM resolution. In addition, ciliary necklaces on the surface of connecting cilium, three-dimensional architecture of synaptic ribbons, and the surface of the post-synaptic membrane facing the active site were revealed, which were not apparent using thin-section EM. AFM could depict the molecular binding of anti-opsin antibodies conjugated to a secondary fluorescent antibody bound to the disk membrane. The specific localization of the anti-opsin binding sites was verified through correlation with immunofluorescence signals in AFM combined with confocal fluorescence microscope. To prove reproducibility in other tissues besides retina, cryosectioning-AFM was also applied to elucidate molecular organization of sarcomere in a rabbit psoas muscle.


Assuntos
Crioultramicrotomia/métodos , Imuno-Histoquímica/métodos , Microscopia de Força Atômica/métodos , Músculos Psoas/citologia , Retina/citologia , Animais , Glutaral , Células Fotorreceptoras de Vertebrados/citologia , Coelhos , Retina/química , Sarcômeros , Sacarose , Inclusão do Tecido/métodos , Xenopus laevis
3.
Sci Rep ; 3: 2131, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-23823461

RESUMO

A hybrid atomic force microscopy (AFM)-optical fluorescence microscopy is a powerful tool for investigating cellular morphologies and events. However, the slow data acquisition rates of the conventional AFM unit of the hybrid system limit the visualization of structural changes during cellular events. Therefore, high-speed AFM units equipped with an optical/fluorescence detection device have been a long-standing wish. Here we describe the implementation of high-speed AFM coupled with an optical fluorescence microscope. This was accomplished by developing a tip-scanning system, instead of a sample-scanning system, which operates on an inverted optical microscope. This novel device enabled the acquisition of high-speed AFM images of morphological changes in individual cells. Using this instrument, we conducted structural studies of living HeLa and 3T3 fibroblast cell surfaces. The improved time resolution allowed us to image dynamic cellular events.


Assuntos
Células , Microscopia de Força Atômica/métodos , Microscopia/métodos , Células 3T3 , Animais , Células HeLa , Humanos , Camundongos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...