Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 33
Filtrar
1.
Malar J ; 22(1): 323, 2023 Oct 25.
Artigo em Inglês | MEDLINE | ID: mdl-37880774

RESUMO

BACKGROUND: Indoor residual spraying (IRS) is a common vector control strategy in countries with high malaria burden. Historically, social norms have prevented women from working in IRS programmes. The Bioko Island Malaria Elimination Project has actively sought to reduce gender inequality in malaria control operations for many years by promoting women's participation in IRS. METHODS: This study investigated the progress of female engagement and compared spray productivity by gender from 2010 to 2021, using inferential tests and multivariable regression. Spray productivity was measured by rooms sprayed by spray operator per day (RSOD), houses sprayed by spray operator per day (HSOD), and the daily productivity ratio (DPR), defined as the ratio of RSOD to HSOD, which standardized productivity by house size. RESULTS: The percentage of women participating in IRS has increased over time. The difference in DPR comparing male and female spray operators was only statistically significant (p < 0.05) for two rounds, where the value was higher for women compared to men. Regression analyses showed marginal, significant differences in DPR between men and women, but beta coefficients were extremely small and thus not indicative of a measurable effect of gender on operational performance. CONCLUSIONS: The quantitative analyses of spray productivity are counter to stigmatizing beliefs that women are less capable than male counterparts during IRS spray rounds. The findings from this research support the participation of women in IRS campaigns, and a renewed effort to implement equitable policies and practices that intentionally engage women in vector control activities.


Assuntos
Inseticidas , Malária , Humanos , Masculino , Feminino , Guiné Equatorial , Controle de Mosquitos , Malária/prevenção & controle
2.
Malar J ; 22(1): 60, 2023 Feb 20.
Artigo em Inglês | MEDLINE | ID: mdl-36803858

RESUMO

BACKGROUND: Rapid diagnostic tests (RDTs) are effective tools to diagnose and inform the treatment of malaria in adults and children. The recent development of a highly sensitive rapid diagnostic test (HS-RDT) for Plasmodium falciparum has prompted questions over whether it could improve the diagnosis of malaria in pregnancy and pregnancy outcomes in malaria endemic areas. METHODS: This landscape review collates studies addressing the clinical performance of the HS-RDT. Thirteen studies were identified comparing the HS-RDT and conventional RDT (co-RDT) to molecular methods to detect malaria in pregnancy. Using data from five completed studies, the association of epidemiological and pregnancy-related factors on the sensitivity of HS-RDT, and comparisons with co-RDT were investigated. The studies were conducted in 4 countries over a range of transmission intensities in largely asymptomatic women. RESULTS: Sensitivity of both RDTs varied widely (HS-RDT range 19.6 to 85.7%, co-RDT range 22.8 to 82.8% compared to molecular testing) yet HS-RDT detected individuals with similar parasite densities across all the studies including different geographies and transmission areas [geometric mean parasitaemia around 100 parasites per µL (p/µL)]. HS-RDTs were capable of detecting low-density parasitaemias and in one study detected around 30% of infections with parasite densities of 0-2 p/µL compared to the co-RDT in the same study which detected around 15%. CONCLUSION: The HS-RDT has a slightly higher analytical sensitivity to detect malaria infections in pregnancy than co-RDT but this mostly translates to only fractional and not statistically significant improvement in clinical performance by gravidity, trimester, geography or transmission intensity. The analysis presented here highlights the need for larger and more studies to evaluate incremental improvements in RDTs. The HS-RDT could be used in any situation where co-RDT are currently used for P. falciparum diagnosis, if storage conditions can be adhered to.


Assuntos
Malária Falciparum , Malária , Adulto , Gravidez , Criança , Humanos , Feminino , Plasmodium falciparum , Testes de Diagnóstico Rápido , Sensibilidade e Especificidade , Malária Falciparum/diagnóstico , Malária Falciparum/epidemiologia , Testes Diagnósticos de Rotina/métodos , Antígenos de Protozoários/análise
3.
PLoS One ; 17(11): e0273872, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36413547

RESUMO

Malaria rapid diagnostic tests (RDTs) have been evaluated in the Peruvian Amazon region and their performance has been variable. This region is known for being the first with documented evidence of wild Plasmodium falciparum parasites lacking pfhrp2 and pfhrp3 genes, leading to false-positive results with HRP2-based RDTs. In our attempt to further characterize the deletion pattern of these genes and their evolutionary relationship, 93 P. falciparum samples, collected in different communities from the Peruvian Amazon region between 2009 and 2010, were analyzed in this study. Genomic DNA was used to amplify 18S rRNA, pfmsp2 and pfglurp to confirm the diagnosis and DNA quality, respectively; pfhrp2, pfhrp3, and their flanking genes were amplified by PCR to assess the pattern of the gene deletions. In addition, microsatellite analysis were performed using seven neutral microsatellites (MS) and five microsatellite loci flanking pfhrp2. The data showed the absence of pfhrp3 gene in 53.76% (50/93) of the samples, reflecting a higher frequency than the proportion of pfhrp2 gene deletions (33.33%; 31/93). Among the flanking genes, the highest frequency of deletion was observed in the PF3D7_0831900 gene (78.49%; 73/93) for pfhrp2. MS marker analysis showed the presence of 8 P. falciparum lineages. The lineage Bv1 was the most prevalent among parasites lacking pfhrp2 and pfhrp3 genes. Additionally, using MS flanking pfhrp2 gene, the haplotypes α and δ were found to be the most abundant in this region. This study confirms the presence in this area of field isolates with deletions in either pfhrp2, pfhrp3, or both genes, along with their respective flanking regions. Our data suggest that some pfhrp2/pfhrp3 deletion haplotypes, in special the lineage Bv1, are widely dispersed within the Peruvian Amazon. The persistence of these haplotypes ensures a proportion of P.falciparum parasites lacking the pfhrp2/pfhrp3 genes in this area, which ultimately leads to false-negative results on PfHRP2-detecting malaria RDTs. However, additional studies are needed to not only confirm this hypothesis but also to further delineate the origin and genetic basis for the pfhrp2- and pfhrp3 gene deletions in wild P. falciparum parasites.


Assuntos
Malária Falciparum , Parasitos , Animais , Plasmodium falciparum/genética , Antígenos de Protozoários/genética , Proteínas de Protozoários/genética , Peru , Deleção de Genes , Malária Falciparum/diagnóstico
4.
Am J Trop Med Hyg ; 106(1): 29-32, 2021 11 08.
Artigo em Inglês | MEDLINE | ID: mdl-34749303

RESUMO

In 2010, the World Health Organization changed its guidance on malaria case management, recommending parasitological confirmation of all suspected cases before treatment with an antimalarial. This recommendation was in large part as a result of the availability of quality assured malaria rapid diagnostic tests (RDTs) that made it possible for malaria diagnosis to be performed by laboratory staff in all health facilities irrespective of the facility's place in the tiered health system. Community health workers and other non-laboratory health workers who traditionally did not perform malaria testing due to the technical and logistic demands of smear microscopy were now able to test for malaria. The use of RDTs has led to substantial increases in testing rates, improved quality of case management, as well as more accurate reporting of malaria cases. Although current RDTs have limitations, they remain one of the most important tools in contemporary malaria control. Further improvements to existing products, such as increased sensitivity for non-falciparum tests, diversification of Plasmodium falciparum antigen targets, along with strengthened health system support for current RDTs will further enhance their utility in malaria control and prevention.


Assuntos
Testes Diagnósticos de Rotina , Malária , Kit de Reagentes para Diagnóstico/parasitologia , Testes Diagnósticos de Rotina/métodos , Testes Diagnósticos de Rotina/normas , Testes Diagnósticos de Rotina/estatística & dados numéricos , Instalações de Saúde , Malária/diagnóstico , Malária/prevenção & controle
5.
Malar J ; 20(1): 217, 2021 May 12.
Artigo em Inglês | MEDLINE | ID: mdl-33980257

RESUMO

BACKGROUND: The radical cure of Plasmodium vivax requires treatment with an 8-aminoquinoline drug, such as primaquine and tafenoquine, to eradicate liver hypnozoite stages, which can reactivate to cause relapsing infections. Safe treatment regimens require prior screening of patients for glucose-6-phosphate dehydrogenase (G6PD) deficiency to avoid potential life-threatening drug induced haemolysis. Testing is rarely available in malaria endemic countries, but will be needed to support routine use of radical cure. This study investigates end-user perspectives in Bangladesh on the introduction of a quantitative G6PD test (SD Biosensor STANDARD™ G6PD analyser) to support malaria elimination. METHODS: The perspectives of users on the SD Biosensor test were analysed using semi-structured interviews and focus group discussions with health care providers and malaria programme officers in Bangladesh. Key emerging themes regarding the feasibility of introducing this test into routine practice, including perceived barriers, were analysed. RESULTS: In total 63 participants were interviewed. Participants emphasized the life-saving potential of the biosensor, but raised concerns including the impact of limited staff time, high workload and some technical aspects of the device. Participants highlighted that there are both too few and too many P. vivax patients to implement G6PD testing owing to challenges of funding, workload and complex testing infrastructure. Implementing the biosensor would require flexibility and improvisation to deal with remote sites, overcoming a low index of suspicion and mutual interplay of declining patient numbers and reluctance to test. This approach would generate new forms of evidence to justify introduction in policy and carefully consider questions of deployment given declining patient numbers. CONCLUSIONS: The results of the study show that, in an elimination context, the importance of malaria needs to be maintained for both policy makers and the affected communities, in this case by ensuring P. vivax, PQ treatment, and G6PD deficiency remain visible. Availability of new technologies, such as the biosensor, will fuel ongoing debates about priorities for allocating resources that must be adapted to a constantly evolving target. Technical and logistical concerns regarding the biosensor should be addressed by future product designs, adequate training, strengthened supply chains, and careful planning of communication, advocacy and staff interactions at all health system levels.


Assuntos
Testes Diagnósticos de Rotina/estatística & dados numéricos , Deficiência de Glucosefosfato Desidrogenase/diagnóstico , Pessoal de Saúde/estatística & dados numéricos , Malária Vivax/diagnóstico , Bangladesh , Testes Diagnósticos de Rotina/psicologia , Pessoal de Saúde/psicologia , Humanos
6.
Malar J ; 19(1): 392, 2020 Nov 04.
Artigo em Inglês | MEDLINE | ID: mdl-33148265

RESUMO

BACKGROUND: Malaria rapid diagnostic tests (RDTs) have greatly improved access to diagnosis in endemic countries. Most RDTs detect Plasmodium falciparum histidine-rich protein 2 (HRP2), but their sensitivity is seriously threatened by the emergence of pfhrp2-deleted parasites. RDTs detecting P. falciparum or pan-lactate dehydrogenase (Pf- or pan-LDH) provide alternatives. The objective of this study was to systematically assess the performance of malaria RDTs against well-characterized pfhrp2-deleted P. falciparum parasites. METHODS: Thirty-two RDTs were tested against 100 wild-type clinical isolates (200 parasites/µL), and 40 samples from 10 culture-adapted and clinical isolates of pfhrp2-deleted parasites. Wild-type and pfhrp2-deleted parasites had comparable Pf-LDH concentrations. Pf-LDH-detecting RDTs were also tested against 18 clinical isolates at higher density (2,000 parasites/µL) lacking both pfhrp2 and pfhrp3. RESULTS: RDT positivity against pfhrp2-deleted parasites was highest (> 94%) for the two pan-LDH-only RDTs. The positivity rate for the nine Pf-LDH-detecting RDTs varied widely, with similar median positivity between double-deleted (pfhrp2/3 negative; 63.9%) and single-deleted (pfhrp2-negative/pfhrp3-positive; 59.1%) parasites, both lower than against wild-type P. falciparum (93.8%). Median positivity for HRP2-detecting RDTs against 22 single-deleted parasites was 69.9 and 35.2% for HRP2-only and HRP2-combination RDTs, respectively, compared to 96.0 and 92.5% for wild-type parasites. Eight of nine Pf-LDH RDTs detected all clinical, double-deleted samples at 2,000 parasites/µL. CONCLUSIONS: The pan-LDH-only RDTs evaluated performed well. Performance of Pf-LDH-detecting RDTs against wild-type P. falciparum does not necessarily predict performance against pfhrp2-deleted parasites. Furthermore, many, but not all HRP2-based RDTs, detect pfhrp2-negative/pfhrp3-positive samples, with implications for the HRP2-based RDT screening approach for detection and surveillance of HRP2-negative parasites.


Assuntos
Antígenos de Protozoários/genética , Testes Diagnósticos de Rotina/estatística & dados numéricos , Deleção de Genes , Malária Falciparum/diagnóstico , Plasmodium falciparum/genética , Proteínas de Protozoários/genética , Malária Falciparum/epidemiologia
7.
Malar J ; 19(1): 324, 2020 Sep 04.
Artigo em Inglês | MEDLINE | ID: mdl-32887612

RESUMO

Microscopy performed on stained films of peripheral blood for detection, identification and quantification of malaria parasites is an essential reference standard for clinical trials of drugs, vaccines and diagnostic tests for malaria. The value of data from such research is greatly enhanced if this reference standard is consistent across time and geography. Adherence to common standards and practices is a prerequisite to achieve this. The rationale for proposed research standards and procedures for the preparation, staining and microscopic examination of blood films for malaria parasites is presented here with the aim of improving the consistency and reliability of malaria microscopy performed in such studies. These standards constitute the core of a quality management system for clinical research studies employing microscopy as a reference standard. They can be used as the basis for the design of training and proficiency testing programmes as well as for procedures and quality assurance of malaria microscopy in clinical research.


Assuntos
Malária/parasitologia , Microscopia/métodos , Testes Diagnósticos de Rotina/métodos , Testes Diagnósticos de Rotina/normas , Humanos , Ensaio de Proficiência Laboratorial/métodos , Ensaio de Proficiência Laboratorial/normas , Microscopia/normas , Controle de Qualidade , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Coloração e Rotulagem/métodos , Coloração e Rotulagem/normas
8.
Am J Trop Med Hyg ; 103(4): 1549-1552, 2020 10.
Artigo em Inglês | MEDLINE | ID: mdl-32748776

RESUMO

Plasmodium vivax is co-endemic with Plasmodium falciparum in Peru, and optimum management requires distinguishing these two species in the blood of patients. For the differential identification of P. vivax and other Plasmodium spp., the LoopampTM Malaria Pan Detection Kit in combination with the Loopamp Malaria Pv Detection Kit (Eiken Chemical Co. Ltd., Tokyo, Japan) was used to evaluate 559 whole blood samples collected in 2017 from febrile patients with suspected malaria attending different health facilities in the Loreto region. The Loopamp Malaria Pan Detection Kit showed a sensitivity of 87.7% (95% CI: 83.5-91.9) and a specificity of 94.4% (95% CI: 91.9-96.9) and good agreement with PCR (Cohen's kappa 0.8266, 95% CI: 0.7792-0.874). By comparison, the Loopamp Malaria Pv Detection Kit showed a similar sensitivity (84.4%, 95% CI: 79.0-89.7) and specificity (92.4%, 95% CI: 89.7-95.0) and substantial agreement with PCR (Cohen's kappa: 0.7661, 95% CI: 0.7088-0.8234).


Assuntos
Malária Vivax/diagnóstico , Malária/diagnóstico , Plasmodium vivax/isolamento & purificação , Plasmodium/isolamento & purificação , Febre , Humanos , Malária/parasitologia , Malária Vivax/parasitologia , Técnicas de Amplificação de Ácido Nucleico , Peru , Plasmodium/genética , Plasmodium vivax/genética , Reação em Cadeia da Polimerase , Sensibilidade e Especificidade
9.
Malar J ; 19(1): 247, 2020 Jul 13.
Artigo em Inglês | MEDLINE | ID: mdl-32660630

RESUMO

BACKGROUND: The production and use of malaria rapid diagnostic tests (RDTs) has risen dramatically over the past 20 years. In view of weak or non-existing in vitro diagnostics (IVD) regulations and post-marketing surveillance (PMS) systems in malaria endemic countries, the World Health Organization, later joined by the Foundation for Innovative New Diagnostics, established an independent, centralized performance evaluation and Lot Testing (LT) programme to safeguard against poor quality of RDTs being distributed through the public health sector of malaria endemic countries. RDT performances and manufacturer quality management systems have evolved over the past decade raising questions about the future need for a centralized LT programme. RESULTS: Between 2007 and 2017, 6056 lots have been evaluated, representing approximately 1.6 Billion RDTs. A total of 69 lots (1.1%) failed the quality control. Of these failures, 26 were detected at receipt of the RDT lot in the LT laboratory, representing an estimated 7.9 million poor quality RDTs, and LT requesters were advised that RDTs were not of sufficient quality for use in patient management. Forty-three were detected after long-term storage in the laboratory, of which 24 (56%) were found to be due to a major issue with insufficient buffer volume in single use buffer vials, others predominantly showing loss of sensitivity. The annual cost of running the programme, based on expenses recorded in years 2014-2016, an estimated volume of 700 lots per year and including replenishment of quality control samples, was estimated at US$ 178,500 ($US 255 per lot tested). CONCLUSIONS: Despite the clear benefits of the centralized LT programme and its low cost compared with the potential costs of each country establishing its own PMS system for RDTs, funding concerns have made its future beyond 2020 uncertain. In order to manage the risks of misdiagnosis due to low quality RDTs, and to ensure the continued safety and reliability of malaria case management, there is a need to ensure that an effective and implementable approach to RDT quality control continues to be available to programmes in endemic countries.


Assuntos
Testes Diagnósticos de Rotina/normas , Malária/diagnóstico , Controle de Qualidade , Testes Diagnósticos de Rotina/economia , Reprodutibilidade dos Testes
10.
BMJ Glob Health ; 5(5)2020 05.
Artigo em Inglês | MEDLINE | ID: mdl-32467355

RESUMO

C reactive protein (CRP), a marker for the presence of an inflammatory process, is the most extensively studied marker for distinguishing bacterial from non-bacterial infections in febrile patients. A point-of-care test for bacterial infections would be of particular use in low-resource settings where other laboratory diagnostics are not always available, antimicrobial resistance rates are high and bacterial infections such as pneumonia are a leading cause of death. This document summarises evidence on CRP testing for bacterial infections in low-income and middle-income countries (LMICs). With a push for universal health coverage and prevention of antimicrobial resistance, it is important to understand if CRP might be able to do the job. The use of CRP polarised the global health community and the aim of this document is to summarise the 'good and the bad' of CRP in multiple settings in LMICs. In brief, the literature that was reviewed suggests that CRP testing may be beneficial in low-resource settings to improve rational antibiotic use for febrile patients, but the positive predictive value is insufficient to allow it to be used alone as a single tool. CRP testing may be best used as part of a panel of diagnostic tests and algorithms. Further studies in low-resource settings, particularly with regard to impact on antibiotic prescribing and cost-effectiveness of CRP testing, are warranted.


Assuntos
Infecções Bacterianas , Proteína C-Reativa , Antibacterianos/uso terapêutico , Infecções Bacterianas/diagnóstico , Infecções Bacterianas/tratamento farmacológico , Biomarcadores , Proteína C-Reativa/análise , Febre/diagnóstico , Febre/tratamento farmacológico , Humanos
11.
Malar J ; 19(1): 129, 2020 Mar 30.
Artigo em Inglês | MEDLINE | ID: mdl-32228615

RESUMO

BACKGROUND: The World Health Organization (WHO) recommends parasite-based diagnosis of malaria. In recent years, there has been surge in the use of various kinds of nucleic-acid amplification based tests (NAATs) for detection and identification of Plasmodium spp. to support clinical care in high-resource settings and clinical and epidemiological research worldwide. However, these tests are not without challenges, including lack (or limited use) of standards and lack of reproducibility, due in part to variation in protocols amongst laboratories. Therefore, there is a need for rigorous quality control, including a robust external quality assessment (EQA) scheme targeted towards malaria NAATs. To this effect, the WHO Global Malaria Programme worked with the UK National External Quality Assessment Scheme (UK NEQAS) Parasitology and with technical experts to launch a global NAAT EQA scheme in January 2017. METHODS: Panels of NAAT EQA specimens containing five major species of human-infecting Plasmodium at various parasite concentrations and negative samples were created in lyophilized blood (LB) and dried blood spot (DBS) formats. Two distributions per year were sent, containing five LB and five DBS specimens. Samples were tested and validated by six expert referee laboratories prior to distribution. Between 37 and 45 laboratories participated in each distribution and submitted results using the online submission portal of UK NEQAS. Participants were scored based on their laboratory's stated capacity to identify Plasmodium species, and individual laboratory reports were sent which included performance comparison with anonymized peers. RESULTS: Analysis of the first three distributions revealed that the factors that most significantly affected performance were sample format (DBS vs LB), species and parasite density, while laboratory location and the reported methodology used (type of nucleic acid extraction, amplification, or DNA vs RNA target) did not significantly affect performance. Referee laboratories performed better than non-referee laboratories. CONCLUSIONS: Globally, malaria NAAT assays now inform a range of clinical, epidemiological and research investigations. EQA schemes offer a way for laboratories to assess and improve their performance, which is critical to safeguarding the reliability of data and diagnoses especially in situations where various NAAT methodologies and protocols are in use.


Assuntos
Testes Diagnósticos de Rotina/estatística & dados numéricos , Malária/diagnóstico , Técnicas de Amplificação de Ácido Nucleico/estatística & dados numéricos , Plasmodium/isolamento & purificação , Garantia da Qualidade dos Cuidados de Saúde/estatística & dados numéricos , Humanos , Controle de Qualidade , Reprodutibilidade dos Testes , Organização Mundial da Saúde
12.
Malar J ; 19(1): 12, 2020 Jan 09.
Artigo em Inglês | MEDLINE | ID: mdl-31918718

RESUMO

BACKGROUND: Malaria diagnostics by rapid diagnostic test (RDT) relies primarily on the qualitative detection of Plasmodium falciparum histidine-rich protein 2 (PfHRP2) and Plasmodium spp lactate dehydrogenase (pLDH). As novel RDTs with increased sensitivity are being developed and implemented as point of care diagnostics, highly sensitive laboratory-based assays are needed for evaluating RDT performance. Here, a quantitative suspension array technology (qSAT) was developed, validated and applied for the simultaneous detection of PfHRP2 and pLDH in a variety of biological samples (whole blood, plasma and dried blood spots) from individuals living in different endemic countries. RESULTS: The qSAT was specific for the target antigens, with analytical ranges of 6.8 to 762.8 pg/ml for PfHRP2 and 78.1 to 17076.6 pg/ml for P. falciparum LDH (Pf-LDH). The assay detected Plasmodium vivax LDH (Pv-LDH) at a lower sensitivity than Pf-LDH (analytical range of 1093.20 to 187288.5 pg/ml). Both PfHRP2 and pLDH levels determined using the qSAT showed to positively correlate with parasite densities determined by quantitative PCR (Spearman r = 0.59 and 0.75, respectively) as well as microscopy (Spearman r = 0.40 and 0.75, respectively), suggesting the assay to be a good predictor of parasite density. CONCLUSION: This immunoassay can be used as a reference test for the detection and quantification of PfHRP2 and pLDH, and could serve for external validation of RDT performance, to determine antigen persistence after parasite clearance, as well as a complementary tool to assess malaria burden in endemic settings.


Assuntos
Antígenos de Protozoários/sangue , L-Lactato Desidrogenase/sangue , Malária Falciparum/diagnóstico , Malária Vivax/diagnóstico , Proteínas de Protozoários/sangue , Adolescente , Adulto , África , Animais , Biotina , Calibragem , Criança , Estudos Transversais , Feminino , Sequenciamento de Nucleotídeos em Larga Escala/métodos , Humanos , Malária Falciparum/sangue , Malária Vivax/sangue , Camundongos , Microesferas , Parasitemia/sangue , Parasitemia/diagnóstico , Gravidez , Reação em Cadeia da Polimerase em Tempo Real , América do Sul , Espanha , Adulto Jovem
13.
Malar J ; 18(1): 387, 2019 Dec 02.
Artigo em Inglês | MEDLINE | ID: mdl-31791354

RESUMO

Malaria rapid diagnostic tests (RDTs) emerged in the early 1990s into largely unregulated markets, and uncertain field performance was a major concern for the acceptance of tests for malaria case management. This, combined with the need to guide procurement decisions of UN agencies and WHO Member States, led to the creation of an independent, internationally coordinated RDT evaluation programme aiming to provide comparative performance data of commercially available RDTs. Products were assessed against Plasmodium falciparum and Plasmodium vivax samples diluted to two densities, along with malaria-negative samples from healthy individuals, and from people with immunological abnormalities or non-malarial infections. Three measures were established as indicators of performance, (i) panel detection score (PDS) determined against low density panels prepared from P. falciparum and P. vivax wild-type samples, (ii) false positive rate, and (iii) invalid rate, and minimum criteria defined. Over eight rounds of the programme, 332 products were tested. Between Rounds 1 and 8, substantial improvements were seen in all performance measures. The number of products meeting all criteria increased from 26.8% (11/41) in Round 1, to 79.4% (27/34) in Round 8. While products submitted to further evaluation rounds under compulsory re-testing did not show improvement, those voluntarily resubmitted showed significant increases in P. falciparum (p = 0.002) and P. vivax PDS (p < 0.001), with more products meeting the criteria upon re-testing. Through this programme, the differentiation of products based on comparative performance, combined with policy changes has been influential in the acceptance of malaria RDTs as a case-management tool, enabling a policy of parasite-based diagnosis prior to treatment. Publication of product testing results has produced a transparent market allowing users and procurers to clearly identify appropriate products for their situation, and could form a model for introduction of other, broad-scale diagnostics.


Assuntos
Testes Diagnósticos de Rotina/estatística & dados numéricos , Malária Falciparum/diagnóstico , Malária Vivax/diagnóstico , Organização Mundial da Saúde , Humanos , Plasmodium falciparum/isolamento & purificação , Plasmodium vivax/isolamento & purificação , Sensibilidade e Especificidade
14.
Am J Trop Med Hyg ; 99(3): 797-804, 2018 09.
Artigo em Inglês | MEDLINE | ID: mdl-30014818

RESUMO

Devices to safely transfer fixed amounts of finger prick blood to rapid diagnostic tests (RDTs) pose a significant challenge, especially in non-laboratory settings. Following the success of an "inverted cup device" for transfer of 5 µL blood, a prototype with a conical cup shape was developed for transfer of 20 µL blood, the amount needed for human immunodeficiency virus or human African trypanosomiasis (HAT) RDTs. This study determined the volume of blood transferred by this new blood transfer device (BTD) and compared its ease of use, safety, and acceptability with that of a plastic pipette when used by health workers (HWs) for HAT RDTs in northwestern Uganda. After a half-day training, 48 HWs had used the two BTDs with at least 10 patients. The conical cup BTD effectively transferred a mean of 22.76 µL of blood (standard deviation 3.31 µL). A significantly higher proportion of HWs were able to collect the full amount of blood using the conical cup BTD, as compared with the pipette (92.4% versus 74.2%, P < 0.001). In HW questionnaires, the conical cup BTD scored higher than the pipette in various aspects of ease of use and safety. In addition, HWs preferred the conical cup BTD (79%), indicating that it was easy to handle, made work faster, and increased their confidence in front of the patient. These findings suggest that the design of the conical cup BTD may be adapted for RDTs requiring 20 µL of blood to facilitate safe and accurate blood transfer.


Assuntos
Coleta de Amostras Sanguíneas/instrumentação , Coleta de Amostras Sanguíneas/métodos , Testes Sorológicos/métodos , Segurança do Sangue , Testes Diagnósticos de Rotina , Pessoal de Saúde , Humanos , Reprodutibilidade dos Testes
15.
PLoS One ; 13(5): e0197395, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29758050

RESUMO

BACKGROUND: Malaria rapid diagnostic tests (RDTs) can produce false positive (FP) results in patients with human African trypanosomiasis and rheumatoid factor (RF), but specificity against other infectious agents and immunological factors is largely unknown. Low diagnostic specificity caused by cross-reactivity may lead to over-estimates of the number of malaria cases and over-use of antimalarial drugs, at the cost of not diagnosing and treating the true underlying condition. METHODS: Data from the WHO Malaria RDT Product Testing Programme was analysed to assess FP rates of 221 RDTs against four infectious agents (Chagas, dengue, Leishmaniasis and Schistosomiasis) and four immunological factors (anti-nuclear antibody, human anti-mouse antibody (HAMA), RF and rapid plasma regain). Only RDTs with a FP rate against clean negative samples less than 10% were included. Paired t-tests were used to compare product-specific FP rates on clean negative samples and samples containing non-Plasmodium infectious agents and immunological factors. RESULTS: Forty (18%) RDTs showed no FP results against any tested infectious agent or immunological factor. In the remaining RDTs significant and clinically relevant increases in FP rates were observed for samples containing HAMA and RF (P<0.001). There were significant correlations between product-matched FP rates for RF and HAMA on all RDT test bands (P<0.001), and FP rates for each infectious agent and immunological factor were also correlated between test bands of combination RDTs (P≤0.002). CONCLUSIONS: False positive results against non-Plasmodium infectious agents and immunological factors does not appear to be a universal property of malaria RDTs. However, since many malaria RDTs have elevated FP rates against HAMA and RF positive samples practitioners may need to consider the possibility of false positive results for malaria in patients with conditions that stimulate HAMA or RF.


Assuntos
Doença de Chagas/diagnóstico , Dengue/diagnóstico , Testes Diagnósticos de Rotina/métodos , Leishmaniose/diagnóstico , Malária/diagnóstico , Esquistossomose/diagnóstico , Antígenos de Protozoários/sangue , Doença de Chagas/parasitologia , Dengue/parasitologia , Reações Falso-Positivas , Humanos , Sistema Imunitário , Leishmaniose/parasitologia , Plasmodium vivax , Reprodutibilidade dos Testes , Esquistossomose/parasitologia , Sensibilidade e Especificidade
16.
Malar J ; 17(1): 29, 2018 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-29334955

RESUMO

BACKGROUND: Malaria rapid diagnostic tests (RDTs) are becoming widely adopted for case management at community level. However, reports and anecdotal observations indicate that the blood transfer step poses a significant challenge to many users. This study sought to evaluate the inverted cup device in the hands of health workers in everyday clinical practice, in comparison with the plastic pipette, and to determine the volume accuracy of the device made of a lower-cost plastic. METHODS: The volume accuracy of inverted cup devices made of two plastics, PMMA and SBC, was compared by transferring blood 150 times onto filter paper and comparing the blood spot areas with those produced by 20 reference transfers with a calibrated micropipette. The ease of use, safety and acceptability of the inverted cup device and the pipette were evaluated by 50 health workers in Nigeria. Observations were recorded on pre-designed questionnaires, by the health workers themselves and by trained observers. Focus group discussions were also conducted. RESULTS: The volume accuracy assessment showed that the device made from the low-cost material (SBC) delivered a more accurate volume (mean 5.4 µL, SD 0.48 µL, range 4.5-7.0 µL) than the PMMA device (mean 5.9 µL, SD 0.48 µL, range 4.9-7.2 µL). The observational evaluation demonstrated that the inverted cup device performed better than the pipette in all aspects, e.g. higher proportions of health workers achieved successful blood collection (96%, vs. 66%), transfer of the required blood volume (90%, vs. 58%), and blood deposit without any loss (95%, vs. 50%). Majority of health workers also considered it' very easy' to use (81%),'very appropriate' for everyday use (78%), and 50% of them reported that it was their preferred BTD. CONCLUSIONS: The good volume accuracy and high acceptability of the inverted cup device shown in this study, along with observed ease of use and safety in hands of health workers, further strengthens prior findings which demonstrated its higher accuracy as compared with other BTDs in a laboratory setting. Altogether, these studies suggest that the inverted cup device should replace other types of devices for use in day-to-day malaria diagnosis with RDTs.


Assuntos
Competência Clínica/estatística & dados numéricos , Agentes Comunitários de Saúde/estatística & dados numéricos , Testes Diagnósticos de Rotina/métodos , Malária/diagnóstico , Testes Diagnósticos de Rotina/estatística & dados numéricos , Grupos Focais , Humanos , Nigéria
17.
Malar J ; 16(1): 196, 2017 05 15.
Artigo em Inglês | MEDLINE | ID: mdl-28506275

RESUMO

BACKGROUND: Malaria rapid diagnostic tests (RDTs) play a critical role in malaria case management, and assurance of quality is a key factor to promote good adherence to test results. Since 2007, the World Health Organization (WHO) and the Foundation for Innovative New Diagnostics (FIND) have coordinated a Malaria RDT Evaluation Programme, comprising a pre-purchase performance evaluation (product testing, PT) and a pre-distribution quality control of lots (lot testing, LT), the former being the basis of WHO recommendations for RDT procurement. Comprehensive information on malaria RDTs sold worldwide based on manufacturers' data and linked to independent performance data is currently not available, and detailed knowledge of procurement practices remains limited. METHODS: The use of the PT/LT Programme results as well as procurement and lot verification practices were assessed through a large-scale survey, gathering product-specific RDT sales and procurement data (2011-14 period) from a total of 32 manufacturers, 12 procurers and 68 National Malaria Control Programmes (NMCPs). RESULTS: Manufacturers' reports showed that RDT sales had more than doubled over the four years, and confirmed a trend towards increased compliance with the WHO procurement criteria (from 83% in 2011 to 93% in 2014). Country-level reports indicated that 74% of NMCPs procured only 'WHO-compliant' RDT products, although procurers' transactions datasets revealed a surprisingly frequent overlap of different products and even product types (e.g., Plasmodium falciparum-only and Plasmodium-pan) in the same year and country (60 and 46% of countries, respectively). Importantly, the proportion of 'non-complying' (i.e., PT low scored or not evaluated) products was found to be higher in the private health care sector than in the public sector (32% vs 5%), and increasing over time (from 22% of private sector sales in 2011 to 39% in 2014). An estimated 70% of the RDT market was covered by the LT programme. The opinion about the PT/LT Programmes was positive overall, and quality of RDTs as per the PT Programme was rated as the number one procurement criteria. CONCLUSIONS: This survey provided in-depth information on RDT sales and procurement dynamics, including the largely unstudied private sector, and demonstrated how the WHO-FIND Programme has positively influenced procurement practices in the public sector.


Assuntos
Testes Diagnósticos de Rotina/economia , Testes Diagnósticos de Rotina/estatística & dados numéricos , Malária/diagnóstico , Comércio/economia , Testes Diagnósticos de Rotina/métodos , Humanos , Setor Privado , Setor Público , Controle de Qualidade , Organização Mundial da Saúde
18.
Malar J ; 16(1): 160, 2017 04 20.
Artigo em Inglês | MEDLINE | ID: mdl-28427428

RESUMO

BACKGROUND: Use of antigen-detecting malaria rapid diagnostic tests (RDTs) has increased exponentially over the last decade. WHO's Global Malaria Programme, FIND, and other collaborators have established a quality assurance scheme to guide product selection, lot verification, transport, storage, and training procedures. Recent concerns over the quality of buffer packaging and test accessories suggest a need to include these items in product assessments. This paper describes quality problems with buffer and accessories encountered in a project promoting private sector RDT use in five African countries and suggests steps to avoid or more rapidly identify and resolve such problems. METHODS: Private provider complaints about RDT buffer vials and kit accessories were collected during supervisory visits, and a standard assessment process was developed. Using 100 tests drawn from six different lots produced by two manufacturers, lab technicians visually assessed alcohol swab packaging, blood transfer device (BTD) usability, and buffer appearance, then calculated mean blood volume from 10 BTD transfers and mean buffer volume from 10 individual buffer vials. WHO guided complaint reporting and follow-up with manufacturers. RESULTS: Supervisory visits confirmed user reports of dry alcohol swabs, poorly functioning BTDs, and non-uniform volumes of buffer. Lot testing revealed further evidence of quality problems, leading one manufacturer to replace buffer vials and accessories for 40,000 RDTs. In December 2014, WHO issued an Information Notice for Users regarding variable buffer volumes in single-use vials and recommended against procurement of these products until defects were addressed. DISCUSSION: Though not necessarily comprehensive or generalizable, the findings presented here highlight the need for extending quality assessment to all malaria RDT test kit contents. Defects such as those described in this paper could reduce test accuracy and increase probability of invalid, false positive, or false negative results. Such deficiencies could undermine provider confidence in RDTs, prompting a return to presumptive treatment or reliance on poor quality microscopy. In partial response to this experience, WHO, FIND, and other project partners have developed guidance on documenting, troubleshooting, reporting, and resolving such problems when they occur.


Assuntos
Antígenos de Protozoários/análise , Soluções Tampão , Testes Diagnósticos de Rotina/métodos , Malária/diagnóstico , Embalagem de Produtos/normas , Kit de Reagentes para Diagnóstico/normas , África , Humanos , Setor Privado
19.
PLoS One ; 10(7): e0131576, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26151448

RESUMO

A number of studies have analyzed the performance of malaria rapid diagnostic tests (RDTs) in Colombia with discrepancies in performance being attributed to a combination of factors such as parasite levels, interpretation of RDT results and/or the handling and storage of RDT kits. However, some of the inconsistencies observed with results from Plasmodium falciparum histidine-rich protein 2 (PfHRP2)-based RDTs could also be explained by the deletion of the gene that encodes the protein, pfhrp2, and its structural homolog, pfhrp3, in some parasite isolates. Given that pfhrp2- and pfhrp3-negative P. falciparum isolates have been detected in the neighboring Peruvian and Brazilian Amazon regions, we hypothesized that parasites with deletions of pfhrp2 and pfhrp3 may also be present in Colombia. In this study we tested 100 historical samples collected between 1999 and 2009 from six Departments in Colombia for the presence of pfhrp2, pfhrp3 and their flanking genes. Seven neutral microsatellites were also used to determine the genetic background of these parasites. In total 18 of 100 parasite isolates were found to have deleted pfhrp2, a majority of which (14 of 18) were collected from Amazonas Department, which borders Peru and Brazil. pfhrp3 deletions were found in 52 of the 100 samples collected from all regions of the country. pfhrp2 flanking genes PF3D7_0831900 and PF3D7_0831700 were deleted in 22 of 100 and in 1 of 100 samples, respectively. pfhrp3 flanking genes PF3D7_1372100 and PF3D7_1372400 were missing in 55 of 100 and in 57 of 100 samples. Structure analysis of microsatellite data indicated that Colombian samples tested in this study belonged to four clusters and they segregated mostly based on their geographic region. Most of the pfhrp2-deleted parasites were assigned to a single cluster and originated from Amazonas Department although a few pfhrp2-negative parasites originated from the other three clusters. The presence of a high proportion of pfhrp2-negative isolates in the Colombian Amazon may have implications for the use of PfHRP2-based RDTs in the region and may explain inconsistencies observed when PfHRP2-based tests and assays are performed.


Assuntos
Antígenos de Protozoários/genética , Deleção de Genes , Plasmodium falciparum/genética , Proteínas de Protozoários/genética , Antígenos de Protozoários/metabolismo , Colômbia/epidemiologia , DNA de Protozoário/análise , DNA de Protozoário/genética , Testes Diagnósticos de Rotina , Eletroforese em Gel de Ágar , Genótipo , Geografia , Humanos , Malária Falciparum/diagnóstico , Malária Falciparum/epidemiologia , Malária Falciparum/parasitologia , Plasmodium falciparum/metabolismo , Reação em Cadeia da Polimerase , Proteínas de Protozoários/metabolismo
20.
Malar J ; 14: 115, 2015 Mar 18.
Artigo em Inglês | MEDLINE | ID: mdl-25889624

RESUMO

BACKGROUND: Malaria rapid diagnostic tests (RDTs) are appropriate for case management, but persistent antigenaemia is a concern for HRP2-detecting RDTs in endemic areas. It has been suggested that pan-pLDH test bands on combination RDTs could be used to distinguish persistent antigenaemia from active Plasmodium falciparum infection, however this assumes all active infections produce positive results on both bands of RDTs, an assertion that has not been demonstrated. METHODS: In this study, data generated during the WHO-FIND product testing programme for malaria RDTs was reviewed to investigate the reactivity of individual test bands against P. falciparum in 18 combination RDTs. Each product was tested against multiple wild-type P. falciparum only samples. Antigen levels were measured by quantitative ELISA for HRP2, pLDH and aldolase. RESULTS: When tested against P. falciparum samples at 200 parasites/µL, 92% of RDTs were positive; 57% of these on both the P. falciparum and pan bands, while 43% were positive on the P. falciparum band only. There was a relationship between antigen concentration and band positivity; ≥4 ng/mL of HRP2 produced positive results in more than 95% of P. falciparum bands, while ≥45 ng/mL of pLDH was required for at least 90% of pan bands to be positive. CONCLUSIONS: In active P. falciparum infections it is common for combination RDTs to return a positive HRP2 band combined with a negative pan-pLDH band, and when both bands are positive, often the pan band is faint. Thus active infections could be missed if the presence of a HRP2 band in the absence of a pan band is interpreted as being caused solely by persistent antigenaemia.


Assuntos
Antígenos de Protozoários/sangue , Testes Diagnósticos de Rotina/métodos , Malária Falciparum/diagnóstico , Plasmodium falciparum/isolamento & purificação , Testes Diagnósticos de Rotina/normas
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...