Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 42
Filtrar
1.
J Am Heart Assoc ; 13(14): e033125, 2024 Jul 16.
Artigo em Inglês | MEDLINE | ID: mdl-38979804

RESUMO

BACKGROUND: Mitral regurgitation (MR) is frequent in patients with aortic stenosis (AS). Although primary MR is an established negative prognostic factor, whether different mechanisms of MR have different effects on outcome is currently unknown. The aim of this study was to evaluate the impact of the MR mechanism in patients undergoing transcatheter aortic valve replacement (TAVR). METHODS AND RESULTS: This is a retrospective observational study of patients who underwent TAVR for severe aortic stenosis in a high-volume tertiary care center. Echocardiographic comprehensive MR assessment was performed at baseline and within 3 months post TAVR. The study population was divided into 4 groups according to MR mechanism: Group I: fibro-calcific leaflet degeneration; Group II: prolapse/flail; Group III: ventricular secondary MR (functional MR); and Group IV: atrial functional MR. The study end point was a combination of death from cardiovascular cause and heart failure-related hospitalization. The study population included 427 patients (mean age 81.7±6.5 years; 71% primary MR; 62% ≥moderate MR). At 3-year follow-up, survival free from the composite end point significantly differs according to MR mechanism: it was higher in group IV (atrial functional MR, 96.6%) compared with group I (80.4%, P=0.002) and group II patients (60.7%, P=0.001), and group III (84.8%, P=0.037); patients with MR due to leaflet prolapse showed poorer prognosis compared with patients with functional MR (group III, P=0.023 and group IV, P=0.001) and with group I (P=0.040). Overall, severe MR after TAVR identified patients with poorer prognosis and was significantly more frequent in group II (46.4%, P=0.001). CONCLUSIONS: In patients undergoing TAVR, preprocedural identification of MR mechanism and mechanism provides prognostic insights.


Assuntos
Estenose da Valva Aórtica , Insuficiência da Valva Mitral , Índice de Gravidade de Doença , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Masculino , Feminino , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/complicações , Estenose da Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/mortalidade , Insuficiência da Valva Mitral/cirurgia , Insuficiência da Valva Mitral/fisiopatologia , Insuficiência da Valva Mitral/complicações , Insuficiência da Valva Mitral/diagnóstico por imagem , Estudos Retrospectivos , Idoso de 80 Anos ou mais , Idoso , Resultado do Tratamento , Ecocardiografia , Fatores de Risco , Fatores de Tempo , Valva Aórtica/cirurgia , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia
4.
J Am Soc Echocardiogr ; 37(6): 591-598, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38522488

RESUMO

BACKGROUND: Echocardiographic grading of mitral regurgitation (MR) in mitral valve prolapse (MVP) is challenging. Three-dimensional (3D) vena contracta area (VCA) has been proposed as a valuable method. However, data defining the cutoff values of severity and validation in the subset of patients with MVP are scarce. The aim of this study was to validate the 3D VCA by 3D color-Doppler transesophageal echocardiography (TEE) in patients with MVP and to define the cutoff values of severity grading. The secondary aim was to compare 3D VCA to the effective regurgitant orifice area estimation by proximal isovelocity surface area (EROA-PISA) method. METHODS: A total of 1,138 patients with at least moderate MR who underwent TEE were included. Three-dimensional VCA was measured, and the cutoff value and area under the curve (AUC) for the prediction of severe MR were estimated by receiver operating characteristic curve using a guideline-suggested multiparametric approach as the reference standard. In a subgroup of patients, 3D regurgitant volume (RV) and 3D fraction were calculated from mitral and left ventricular outflow tract stroke volumes to further validate 3D VCA against a 3D volumetric reference standard. RESULTS: The optimal 3D VCA cutoff value for predicting severe MR was 0.45 cm2 (specificity, 0.87; sensitivity, 0.90) with an AUC of 0.95 using a multiparametric approach as reference. Three-dimensional VCA had a good linear correlation with EROA-PISA (r = 0.62, P < .05) with larger values compared to EROA-PISA (0.63 cm2 vs 0.44 cm2, P < .05). A cutoff of 0.50 cm2 (AUC of 0.84; sensitivity, 0.78; specificity, 0.78) predicts an EROA-PISA of 0.40 cm2. Three-dimensional VCA had a good linear correlation with 3D RV (r = 0.56, P < .01), with an AUC of 0.86 to predict a 3D fraction >50%. CONCLUSIONS: The present study suggests 0.45 cm2 as the best cutoff value of 3D VCA to define severe MR in patients with MVP, showing an optimal agreement with the reference standard multiparametric approach and 3D RV.


Assuntos
Ecocardiografia Tridimensional , Insuficiência da Valva Mitral , Prolapso da Valva Mitral , Índice de Gravidade de Doença , Humanos , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/fisiopatologia , Ecocardiografia Tridimensional/métodos , Feminino , Masculino , Prolapso da Valva Mitral/complicações , Prolapso da Valva Mitral/diagnóstico por imagem , Prolapso da Valva Mitral/fisiopatologia , Pessoa de Meia-Idade , Idoso , Ecocardiografia Transesofagiana/métodos , Ecocardiografia Doppler em Cores/métodos , Reprodutibilidade dos Testes , Valva Mitral/diagnóstico por imagem , Curva ROC , Estudos Retrospectivos
6.
Int J Cardiol ; 389: 131188, 2023 10 15.
Artigo em Inglês | MEDLINE | ID: mdl-37453454

RESUMO

BACKGROUND: LAAO is an emerging option for thromboembolic event prevention in patients with NVAF. We previously reported data on comparison between LAAO and DOAC at two-year follow-up in NVAF patients at HBR (HAS-BLED ≥3). AIMS: Limited data are available on long term follow-up. We aimed to evaluate the efficacy and safety of DOACs versus LAAO indication after 5 years. METHODS: We enrolled 193 HBR treated with LAAO and 189 HBR patients with DOACs. At baseline, LAAO group had higher HAS-BLED (4.2 vs 3.3, p < 0.001) and lower CHADS-VASc (4.3 vs. 4.7, p = 0.005). After 1:1 PSM, 192 patients were included (LAAO n = 96; DOACs n = 96). RESULTS: At 5-year follow-up the rate of the combined safety and effectiveness endpoint (ISTH major bleeding and thromboembolic events) was significantly higher in LAAO group (p = 0.042), driven by a higher number of thromboembolic events (p = 0.047). The rate of ISTH-major bleeding events was similar (p = 0.221). After PSM no significant difference in the primary effectiveness (LAAO 13.3% vs DOACs 9.5%, p = 0.357) and safety endpoint (LAAO 7.5% vs DOACs 7.5%; p = 0.918) were evident. Overall bleeding rate was significantly higher in DOACs group (25.0% vs 13.7%, p = 0.048), while a non-significant higher number of TIA was reported in LAAO group (5.4% vs 1.1%, p = 0.098). All-cause and cardiovascular mortality were higher in LAAO group at both unmatched and matched analysis. CONCLUSION: We confirmed safety and effectiveness of both DOAC and LAAO in NVAF patients at HBR, with no significant differences in thromboembolic events or major bleeding were at 5-year follow-up. The observed increased mortality after LAAO warrants further investigations in RCTs.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Acidente Vascular Cerebral , Tromboembolia , Humanos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/tratamento farmacológico , Fibrilação Atrial/cirurgia , Acidente Vascular Cerebral/epidemiologia , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/prevenção & controle , Apêndice Atrial/cirurgia , Hemorragia/induzido quimicamente , Anticoagulantes/efeitos adversos , Tromboembolia/epidemiologia , Tromboembolia/etiologia , Tromboembolia/prevenção & controle , Resultado do Tratamento
7.
Front Cardiovasc Med ; 10: 1172005, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37383696

RESUMO

Background: Percutaneous left atrial appendage occlusion (LAAO) presents many technical complex features, and it is often performed under the intraprocedural surveillance of a product specialist (PS). Our aim is to assess whether LAAO is equally safe and effective when performed in high-volume centers without PS support. Methods: Intraprocedural results and long-term outcome were retrospectively assessed in 247 patients who underwent LAAO without intraprocedural PS monitoring between January 2013 and January 2022 at three different hospitals. This cohort was then matched to a population who underwent LAAO with PS surveillance. The primary end point was all-cause mortality at 1 year. The secondary end point was a composite of cardiovascular mortality plus nonfatal ischemic stroke occurrence at 1 year. Results: Of the 247 study patients, procedural success was achieved in 243 patients (98.4%), with only 1 (0.4%) intraprocedural death. After matching, we did not identify any significant difference between the two groups in terms of procedural time (70 ± 19 min vs. 81 ± 30 min, p = 0.106), procedural success (98.4% vs. 96.7%, p = 0.242), and procedure-related ischemic stroke (0.8% vs. 1.2%, p = 0.653). Compared to the matched cohort, a significant higher dosage of contrast was used during procedures without specialist supervision (98 ± 19 vs. 43 ± 21, p < 0.001), but this was not associated with a higher postprocedural acute kidney injury occurrence (0.8% vs. 0.4%, p = 0.56). At 1 year, the primary and the secondary endpoints occurred in 21 (9%) and 11 (4%) of our cohort, respectively. Kaplan-Meier curves showed no significant difference in both primary (p = 0.85) and secondary (p = 0.74) endpoint occurrence according to intraprocedural PS monitoring. Conclusions: Our results show that LAAO, despite the absence of intraprocedural PS monitoring, remains a long-term safe and effective procedure, when performed in high-volume centers.

8.
J Arrhythm ; 39(3): 395-404, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-37324751

RESUMO

Background: The role of left atrial appendage occlusion (LAAO) for atrial fibrillation patients that during oral anticoagulant therapy (OAC) suffer from ischemic events or present LAA sludge, and the best postinterventional anticoagulant regimen, need to be defined. We present our experience with a hybrid approach of LAAO+ lifelong OAC therapy in this cohort of patients. Methods: Out of 425 patients treated with LAAO, 102 underwent LAAO because, despite OAC, suffered from ischemic events or presented with LAA sludge. Patients without high bleeding risk were discharged with the aim of maintaining lifelong OAC. This cohort was then matched to a population who underwent LAAO in primary ischemic events prevention. The primary endpoint was the composite of all-cause death and major adverse cardiovascular events consisting of ischemic stroke, systemic embolism (SE), and major bleeding. Results: Procedural success was 98%, and 70% of patients were discharged with anticoagulant therapy. After a median follow-up of 47.2 months, the primary endpoint occurred in 27 patients (26%). At multivariate analyses, coronary artery disease (OR 5.1, CI 1.89-14.27, p = .003) and OAC at discharge (OR 0.29, CI 0.11-0.80, p = .017) were associated with the primary endpoint. After propensity score matching, no significant difference was found in the survival free from the primary endpoint according to the indication for LAAO (p = .19). Conclusions: In this high-ischemic risk cohort, LAAO + OAC seem a long-term safe and effective therapeutical approach, with no difference in the survival free from the primary endpoint according to the indication for LAAO in a matched cohort.

9.
Echocardiography ; 40(8): 775-783, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37351556

RESUMO

AIM: we sought to test the inter-center reproducibility of 16 echo laboratories involved in the EACVI-Afib Echo Europe. METHODS: This was done on a dedicated setting of 10 patients with sinus rhythm (SR) and 10 with persistent atrial fibrillation (AF), collected by the Principal Investigator. Images and loops of echo-exams were stored and made available for labs. The tested measurements included main echo-Doppler parameters, global longitudinal strain (GLS) and peak atrial longitudinal strain (PALS). RESULTS: Single measures interclass correlation coefficients (ICCs) of left ventricular mass and ejection fraction were suboptimal in both patients with SR and AF. Among diastolic parameters, ICCs of deceleration time were poor, in particular in AF (=.50). ICCs of left atrial size and function, besides optimal in AF, showed an acceptable despite moderate concordance in SR. ICC of GLS was .81 and .78 in SR and AF respectively. ICCs of PALS were suitable but lower in 4-chamber than in 2-chamber view. By depicting the boxplot of the 16 laboratories, GLS distribution was completely homogeneous in SR, whereas GLS of AF and PALS of both SR and AF presented a limited number of outliers. GLS mean ± SE of the 16 labs was 19.7 ± .36 (95% CI: 18.8-20.4) in SR and 16.5 ± .29 (95% CI: 15.9-17.1) in AF, whereas PALS mean ± SE was 43.8 ± .70 (95% CI: 42.3-45.3) and 10.2 ± .32 (95% CI: 9.5-10.9) respectively. CONCLUSION: While the utilization of some standard-echo variables should be discouraged in registries, the application of GLS and PALS could be largely promoted because their superior reproducibility, even in AF.


Assuntos
Fibrilação Atrial , Humanos , Reprodutibilidade dos Testes , Ecocardiografia/métodos , Átrios do Coração/diagnóstico por imagem , Sistema de Registros
10.
Int J Cardiol ; 387: 131135, 2023 09 15.
Artigo em Inglês | MEDLINE | ID: mdl-37364718

RESUMO

BACKGROUND: To evaluate the long-term clinical outcome of a cohort of patients suffering from moderate tricuspid regurgitation (TR), regardless of its etiology. METHODS: Clinical and echocardiographic follow-up were assessed in 250 patients diagnosed with moderate TR between January 2016 and July 2020. TR progression at follow-up was defined as TR grade increase to at least severe. The primary endpoint was all-cause death; secondary endpoints were cardiovascular (CV) death and the composite of heart failure (HF) hospitalization plus tricuspid valve (TV) intervention. RESULTS: After a median follow-up of 3.6 years, TR progression occurred in 84 patients (34%). At multivariate analyses, atrial fibrillation (AF, OR 1.81, CI 1.01-3.29, p = 0.045) and right ventricular end-diastolic diameter (RVEDD, OR 2.19, CI 1.26-3.78, p = 0.005) were independent predictors of TR progression. The primary endpoint occurred in 59 patients (24%) and was significantly more frequent in the group with TR progression (p = 0.009). At multivariate analyses, chronic kideney disease (OR 2.80, CI 1.30-6.03, p = 0.009), left ventricular ejection fraction (OR 0.97, CI 0.94-0.99, p = 0.041) and TR progression (OR 2.32, CI 1.31-4.12, p = 0.004) were independent predictors of the primary outcome. Moreover, both the secondary endpoints of CV death and HF hospitalization plus TV intervention were more frequent in the TR progression group (p = 0.001 and p < 0.001, respectively). CONCLUSIONS: Moderate TR progresses in a significant proportion of patients over a long-term follow-up, leading to a worse prognosis. TR progression is an independent determinant of hard clinical events and AF and RVEDD are associated with TR progression.


Assuntos
Insuficiência Cardíaca , Insuficiência da Valva Tricúspide , Humanos , Insuficiência da Valva Tricúspide/diagnóstico por imagem , Volume Sistólico , Função Ventricular Esquerda , Estudos Retrospectivos , Insuficiência Cardíaca/diagnóstico por imagem , Insuficiência Cardíaca/complicações , Doença Crônica , Progressão da Doença
11.
J Am Soc Echocardiogr ; 36(10): 1083-1091, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-37307939

RESUMO

BACKGROUND: Contrast-enhanced computed tomography is the reference-standard imaging technique to assess left atrial appendage (LAA) morphology. The aim of this study was to evaluate the accuracy and reliability of two-dimensional and new three-dimensional (3D) transesophageal echocardiographic rendering modalities in assessing LAA morphology. METHODS: Seventy consecutive patients who underwent both computed tomography and transesophageal echocardiography (TEE) were retrospectively enrolled. The traditional LAA morphology classification system (LAAcs; chicken wing, cauliflower, cactus, and windsock) and a new simplified LAAcs based on the LAA bend angle were used for the analysis. LAA morphology was independently assessed by two trained readers using three different modalities: two-dimensional TEE, 3D TEE with multiplanar reconstruction, and a new 3D transesophageal echocardiographic rendering modality with improved transparency (Glass). The new LAAcs and traditional LAAcs were compared in terms of intra- and interrater reliability. RESULTS: With the new LAAcs, two-dimensional TEE was fairly accurate in identifying LAA morphology (κ = 0.43, P < .05), with moderate interrater (κ = 0.50, P < .05) and substantial intrarater (κ = 0.65, P < .005) agreement. Three-dimensional TEE showed higher accuracy and reliability: 3D TEE with multiplanar reconstruction had almost perfect accuracy (κ = 0.85, P < .001) and substantial (κ = 0.79, P < .001) interrater reliability, while 3D TEE with Glass had substantial accuracy (κ = 0.70, P < .001) and almost perfect (κ = 0.84, P < .001) interrater reliability. Intrarater agreement was almost perfect for both 3D transesophageal echocardiographic modalities (κ = 0.85, P < .001). Accuracy was considerably lower when the traditional LAAcs was used, with 3D TEE with Glass being the most reliable technique (κ = 0.75, P < .05). The new LAAcs showed higher inter- and intrarater reliability compared with the traditional LAAcs (interrater, κ = 0.85 vs κ = 0.49; intrarater, κ = 0.94 vs κ = 0.68; P < .05). CONCLUSIONS: Three-dimensional TEE is an accurate, reliable, and feasible alternative to computed tomography in assessing LAA morphology with the new LAAcs. The new LAAcs shows higher reliability rates than the traditional one.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Humanos , Ecocardiografia Transesofagiana/métodos , Reprodutibilidade dos Testes , Estudos Retrospectivos , Tomografia Computadorizada por Raios X
12.
Eur Heart J Suppl ; 25(Suppl C): C189-C199, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-37125282

RESUMO

Treatments for structural heart diseases (SHD) have been considerably evolved by the widespread of transcatheter approach in the last decades. The progression of transcatheter treatments for SHD was feasible due to the improvement of devices and the advances in imaging techniques. In this setting, the cardiovascular imaging is pivotal not only for the diagnosis but even for the treatment of SHD. With the aim of fulfilling these tasks, a multimodality imaging approach with new imaging tools for pre-procedural planning, intra-procedural guidance, and follow-up of SHD was developed. This review will describe the current state-of-the-art imaging techniques for the most common percutaneous interventions as well as the new imaging tools. The imaging approaches will be addressed describing the use in pre-procedural planning, intra-procedural guidance, and follow-up.

13.
Eur Heart J Cardiovasc Imaging ; 24(11): 1509-1517, 2023 10 27.
Artigo em Inglês | MEDLINE | ID: mdl-37194460

RESUMO

AIMS: To evaluate the prognostic impact of pre-procedural right ventricular longitudinal strain (RVLS) in patients with secondary mitral regurgitation (SMR) undergoing transcatheter edge-to-edge repair (TEER) in comparison with conventional echocardiographic parameters of RV function. METHODS AND RESULTS: This is a retrospective study including 142 patients with SMR undergoing TEER at two Italian centres. At 1-year follow-up 45 patients reached the composite endpoint of all-cause death or heart failure hospitalization. The best cut-off value of RV free-wall longitudinal strain (RVFWLS) to predict outcome was -18% [sensitivity 72%, specificity of 71%, area under curve (AUC) 0.78, P < 0.001], whereas the best cut-off value of RV global longitudinal strain (RVGLS) was -15% (sensitivity 56%, specificity 76%, AUC 0.69, P < 0.001). Prognostic performance was suboptimal for tricuspid annular plane systolic excursion, Doppler tissue imaging-derived tricuspid lateral annular systolic velocity and fractional area change (FAC). Cumulative survival free from events was lower in patients with RVFWLS ≥ -18% vs. RVFWLS < -18% (44.0% vs. 85.4%; < 0.001) as well as in patients with RVGLS ≥ -15% vs. RVGLS < -15% (54.9% vs. 81.7%; P < 0.001). At multivariable analysis FAC, RVGLS and RVFWLS were independent predictors of events. The identified cut-off of RVFWLS and RVGLS both resulted independently associated with outcomes. CONCLUSION: RVLS is a useful and reliable tool to identify patients with SMR undergoing TEER at high risk of mortality and HF hospitalization, on top of other clinical and echocardiographic parameters, with RVFWLS offering the best prognostic performance.


Assuntos
Insuficiência da Valva Mitral , Disfunção Ventricular Direita , Humanos , Prognóstico , Estudos Retrospectivos , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/cirurgia , Insuficiência da Valva Mitral/complicações , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Valor Preditivo dos Testes
14.
Int J Cardiol ; 384: 55-61, 2023 08 01.
Artigo em Inglês | MEDLINE | ID: mdl-37149007

RESUMO

BACKGROUND: In terms of pathophysiology, tricuspid regurgitation (TR), right ventricular function and pulmonary artery pressure are linked to each other. Our aim was to analyze whether the echocardiography-derived right ventricular free wall longitudinal strain/pulmonary artery systolic pressures (RVFWLS/PASP) ratio can improve risk stratification in patients with severe tricuspid regurgitation (TR). METHODS: In this single-center retrospective study, 250 consecutive patients with severe TR were enrolled from December 2015 to December 2018. Baseline clinical and echocardiographic parameters were collected. Echocardiography-derived TAPSE/PASP and RVFWLS/PASP were evaluated. The primary endpoint was all-cause mortality. RESULTS: Out of 250 consecutive patients, 171 meet inclusion criteria. Patients were predominantly female, with several cardiovascular risk factors and comorbidities. RVFWLS/PASP ≤0.34%/mmHg (AUC 0.68, p < 0.001, sensitivity 70%, specificity 67%) was associated with baseline clinical RV heart failure (p = 0.03). After univariate and multivariate analyses, RVFWLS/PASP, but not TAPSE/PASP, independently correlated with all-cause mortality (HR 0.004, p = 0.02). Patients with RVFWLS/PASP >0.26%/mmHg (AUC 0.74, p < 0.001, sensitivity 77%, specificity 52%) showed higher survival rates (p = 0.02). In addition at 24 months follow-up, the Kaplan-Meyer curves showed patients with RVFWLS >14% & RVFWLS/PASP >0.26%/mmHg had the best survival rate compared to patients without. CONCLUSION: RVFWLS/PASP is independently associated with baseline RV heart failure and poor long-term prognosis in patients with severe TR.


Assuntos
Insuficiência Cardíaca , Hipertensão Pulmonar , Insuficiência da Valva Tricúspide , Disfunção Ventricular Direita , Humanos , Feminino , Masculino , Prognóstico , Insuficiência da Valva Tricúspide/diagnóstico por imagem , Pressão Sanguínea , Ecocardiografia Doppler , Estudos Retrospectivos , Função Ventricular Direita/fisiologia , Artéria Pulmonar/diagnóstico por imagem
15.
Eur Heart J Cardiovasc Imaging ; 24(7): 887-896, 2023 06 21.
Artigo em Inglês | MEDLINE | ID: mdl-36916015

RESUMO

AIMS: Transcatheter aortic valve implantation (TAVI) is the treatment of choice for high-risk patients with severe aortic stenosis (AS). A portion of TAVI recipients has no long-term clinical benefit, and myocardial fibrosis may contribute to unfavourable outcomes. We aimed to assess the prognostic value of an interstitial fibrosis marker, extracellular volume fraction (ECV), measured at planning computed tomography (CT) before TAVI. METHODS AND RESULTS: From October 2020 to July 2021, 159 consecutive patients undergoing TAVI planning CT were prospectively enroled. ECV was calculated as the ratio of myocardium and blood pool differential attenuations before and 5 min after contrast administration, pondered for haematocrit. A composite endpoint including heart failure hospitalization (HFH) and death was collected by telehealth or in-person follow-up visits in the 113 patients constituting the final study population. Cox proportional hazards model was used to assess association between ECV and the composite endpoint.Median follow-up was 13 (11-15) months. The composite endpoint occurred in 23/113 (20%) patients. These patients had lower aortic valve mean pressure gradient [39 (29-48) vs. 46 (40-54) mmHg, P = 0.002] and left ventricular and right ventricular ejection fraction [51 (37-69) vs. 66 (54-74)%, P = 0.014; 45 (31-53) vs. 49 (44-55)%, P = 0.010] and higher ECV [31.5 (26.9-34.3) vs. 27.8 (25.3-30.2)%, P = 0.006]. At multivariable Cox analysis, ECV higher than 31.3% was associated to increased risk of death or HFH at follow-up (hazard ratio = 5.92, 95% confidence interval 2.37-14.75, P < 0.001). CONCLUSION: In this prospective observational cohort study, ECV measured at TAVI planning CT predicts the composite endpoint (HFH or death) in high-risk severe AS patients.


Assuntos
Estenose da Valva Aórtica , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Volume Sistólico , Resultado do Tratamento , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Estudos Prospectivos , Função Ventricular Direita , Prognóstico , Valva Aórtica/cirurgia , Fibrose , Tomografia Computadorizada por Raios X , Tomografia , Função Ventricular Esquerda
16.
Eur Heart J Cardiovasc Imaging ; 24(8): 1043-1051, 2023 07 24.
Artigo em Inglês | MEDLINE | ID: mdl-36797650

RESUMO

AIMS: The procedural planning of transcatheter mitral valve replacement (TMVR) requires a specific imaging assessment to establish patient eligibility. Computed tomography (CT) is considered the reference method. In this setting, data regarding the role of transoesophageal echocardiography (TOE) are lacking. We evaluated the feasibility and reliability of a comprehensive 3D-TOE screening in TMVR candidates. METHODS AND RESULTS: We performed a retrospective observational study including 72 consecutive patients who underwent a pre-procedural CT and 3D-TOE for TMVR evaluation. The measurements of mitral annulus (MA), length of anterior mitral leaflet (AML), native left ventricular outflow tract (LVOT), and predicted neo-LVOT acquired with CT and 3D-TOE were compared using a novel semi-automated software for post processing analysis (3 mensio Structural Heart 10.1-3mSH, Pie Medical Imaging, Bilthoven, Netherlands). The final suitability decision was given by the valve manufacturer based on CT measurements and clinical conditions. Among 72 patients screened, all patients had adequate image quality for 3D-TOE analysis. 3D-TOE and CT measurements for AML length (r = 0.97), MA area (r = 0.90), perimeter (r = 0.68), anteroposterior (r = 0.88), and posteromedial-anterolateral (r = 0.74) diameters were found highly correlated, as well as for native LVOT (r = 0.86) and predicted neo-LVOT areas (r = 0.96) (all P-values <0.0001). An almost perfect agreement between CT and 3DTOE was found in assessing the eligibility for TMVR implantation (Cohen kappa 0.83, P < 0.001). CONCLUSION: 3D-TOE appraisements showed good correlations with CT measurements and high accuracy to predict TMVR screening success.


Assuntos
Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Leucemia Mieloide Aguda , Insuficiência da Valva Mitral , Obstrução do Fluxo Ventricular Externo , Humanos , Valva Mitral/diagnóstico por imagem , Implante de Prótese de Valva Cardíaca/métodos , Ecocardiografia Transesofagiana , Reprodutibilidade dos Testes , Estudos de Viabilidade , Resultado do Tratamento , Cateterismo Cardíaco/métodos , Insuficiência da Valva Mitral/cirurgia
17.
J Heart Lung Transplant ; 42(4): 451-455, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36682892

RESUMO

Intra-Aortic Balloon Pump (IABP) efficacy is critically affected by the inflation/deflation timing. Balloon deflation may cause a sucking effect, and a steal phenomenon on carotid flow. Delaying IABP deflation reduces the degree of this flow reversal, but at the same time exposes patients to the risk of increased proto-systolic afterload with detrimental effects on the LV. The purpose of this study was to investigate the effects of a delayed IABP deflation timing on cerebral blood flow and LV hemodynamics, by means of simultaneous carotid artery ultrasonography, trans-thoracic echocardiography and central aortic pressure analysis. Delaying IABP deflation trigger to the beginning of QRS effectively increased the cerebral blood flow by 20%, mostly by reducing the reverse component flow caused by the diastolic balloon deflation. Extending the deflation to the early systole was safe and favourably impacted on cardiac mechanics, increasing CO by 15% without prolonging LV isovolumetric contraction and ejection phases.


Assuntos
Artérias Carótidas , Circulação Cerebrovascular , Ventrículos do Coração , Balão Intra-Aórtico , Humanos , Ecocardiografia , Coração/diagnóstico por imagem , Coração/fisiopatologia , Coração Auxiliar , Hemodinâmica , Balão Intra-Aórtico/métodos , Fatores de Tempo , Artérias Carótidas/diagnóstico por imagem , Artérias Carótidas/fisiopatologia , Circulação Cerebrovascular/fisiologia , Pressão Arterial/fisiologia , Ventrículos do Coração/fisiopatologia
18.
Am J Cardiol ; 190: 25-31, 2023 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-36543077

RESUMO

During transcatheter edge-to-edge repair (TEER), the reduction of functional mitral regurgitation (FMR) severity, compared with baseline evaluation, is not uncommon. Because the procedural strategies are mainly guided by the location and severity of the regurgitant jets, intraprocedural downgrading (ID) of regurgitation severity could affect the procedural strategy and the results. The aim of this study was to evaluate the prevalence of ID during TEER and to compare early and midterm outcomes in patients with and without ID. All patients with moderate-to-severe or severe FMR who underwent TEER in San Raffaele Hospital between 2018 and 2020 were evaluated in this single-center, retrospective study. ID was defined as mild (1+) or moderate (2+) regurgitation degree during intraprocedural evaluation. The outcomes, assessed at discharge and at 2 years of follow-up, were all-cause mortality, heart failure hospitalization, and recurrence of mitral regurgitation >2+. The final study cohort included 55 patients: 42% presented with ID. At discharge, 85.5% of patients achieved regurgitation reduction to 2+ or less: 100% in patients with ID versus 75% in patients without ID, p <0.009. At 2 years, no significant difference in the incidence of all-cause mortality, heart failure hospitalization, and the recurrence of mitral regurgitation >2+ between patients with ID or without ID was found. In conclusion, ID is frequent during TEER in FMR. No baseline characteristics were found to identify this group of patients. In patients with ID, the combination of live intraprocedural imaging and baseline ambulatory assessment of regurgitant jets seems effective in the procedural guiding to achieve a successful and durable mitral repair.


Assuntos
Anestesia , Insuficiência Cardíaca , Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Mitral , Humanos , Insuficiência da Valva Mitral/epidemiologia , Insuficiência da Valva Mitral/cirurgia , Estudos Retrospectivos , Insuficiência Cardíaca/epidemiologia , Hospitalização , Vômito , Resultado do Tratamento , Cateterismo Cardíaco
19.
Am Heart J ; 255: 94-105, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-36272451

RESUMO

BACKGROUND: Several electrocardiogram (ECG) criteria have been proposed to predict the location of the culprit occlusion in specific subsets of patients presenting with ST-segment elevation myocardial infarction (STEMI). The aim of this study was to develop, through an independent validation of currently available criteria, a comprehensive and easy-to-use ECG algorithm, and to test its diagnostic performance in real-world clinical practice. METHODS: We analyzed ECG and angiographic data from 419 consecutive STEMI patients submitted to primary percutaneous coronary intervention over a one-year period, dividing the overall population into derivation (314 patients) and validation (105 patients) cohorts. In the derivation cohort, we tested >60 previously published ECG criteria, using the decision-tree analysis to develop the algorithm that would best predict the infarct-related artery (IRA) and its occlusion level. We further assessed the new algorithm diagnostic performance in the validation cohort. RESULTS: In the derivation cohort, the algorithm correctly predicted the IRA in 88% of cases and both the IRA and its occlusion level (proximal vs mid-distal) in 71% of cases. When applied to the validation cohort, the algorithm resulted in 88% and 67% diagnostic accuracies, respectively. In a real-world comparative test, the algorithm performed significantly better than expert physicians in identifying the site of the culprit occlusion (P = .026 vs best cardiologist and P < .001 vs best emergency medicine doctor). CONCLUSIONS: Derived from an extensive literature review, this comprehensive and easy-to-use ECG algorithm can accurately predict the IRA and its occlusion level in all-comers STEMI patients.


Assuntos
Oclusão Coronária , Infarto do Miocárdio , Intervenção Coronária Percutânea , Infarto do Miocárdio com Supradesnível do Segmento ST , Humanos , Oclusão Coronária/complicações , Oclusão Coronária/diagnóstico , Angiografia Coronária , Infarto do Miocárdio/diagnóstico , Eletrocardiografia/métodos , Infarto do Miocárdio com Supradesnível do Segmento ST/diagnóstico
20.
Cardiovasc Revasc Med ; 43: 1-6, 2022 10.
Artigo em Inglês | MEDLINE | ID: mdl-35690553

RESUMO

BACKGROUND: Transcatheter aortic valve implant (TAVI) is gaining momentum in the treatment of severe, symptomatic aortic valve stenosis, and its indication is expanding to lower surgical risk individuals, who are generally younger and have a long life expectancy. Therefore, transcatheter bioprostheses durability appears of critical importance. Aim of the present study is to evaluate mid-term outcomes of TAVI in a high-volume single center cohort. METHODS: We analyzed all consecutive patients (n = 408) who underwent transfemoral TAVI at a single, high-volume center, between 2007 and 2014. Study objectives were all-cause death and bioprosthetic valve failure (BVF) at long term follow-up. Structural valve deterioration (SVD), BVF and valve-related death were defined according to current international standards. Follow-up was performed by in person visit and transthoracic echocardiography, which was obtained only in a minority of patients, or phone call as per patient preference. RESULTS: At a median follow-up of 1821 days, overall mortality was 64.5%, with cardiovascular disease accounting for roughly half of total deaths. Valve-related deaths occurred in 10 patients. Seventeen patients were diagnosed with BVF, and 15 required repeat intervention. Moderate and severe SVD were observed in 10 and 7 patients, respectively. In the subgroup of patients with echocardiographic mid-term follow-up (n = 76), no significant increase of transprosthetic gradients nor increase of significant regurgitation was detected. CONCLUSION: In the present unselected, all-comers cohort, TAVI bioprostheses appeared to have excellent durability at long-term follow-up.


Assuntos
Estenose da Valva Aórtica , Bioprótese , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Humanos , Desenho de Prótese , Falha de Prótese , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...