Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Clin Ophthalmol ; 16: 2955-2968, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36071724

RESUMO

Purpose: To evaluate 3-year safety and efficacy of two second-generation trabecular micro-bypass stents. (iStent inject ®) with phacoemulsification. Materials and Methods: This multicenter retrospective study of iStent inject implantation with phacoemulsification included data from eight surgeons across Australia. Eyes with cataract and mild to advanced glaucoma [predominantly primary open-angle (POAG), primary angle closure (PAC), or normal-tension (NTG) glaucoma] or ocular hypertension (OHT) were included. Study assessments included intraocular pressure (IOP); number of ocular hypotensive medications; proportions of eyes with 0, 1, 2, or ≥3 IOP-lowering medications; IOP ≤15 mmHg or ≤18 mmHg; visual fields (VF); retinal nerve fiber layer thickness (RNFL); central corneal thickness (CCT); intraoperative complications; adverse events; and secondary surgeries. Results: A total of 273 eyes underwent surgery and had 36-month follow-up. At 36 months versus preoperative, mean IOP decreased by 15.5% (16.4±4.6 mmHg to 13.9±3.5 mmHg; p<0.001), and 70.3% of eyes achieved IOP of ≤15 mmHg (versus 49.1% preoperatively; p<0.001). The mean medication burden decreased by 68.5% (from 1.51±1.17 to 0.48±0.89 medications; p<0.001); 71.4% of eyes were medication-free (versus 21.6% preoperatively; p<0.001), while 6.2% of eyes were on ≥3 medications (versus 22.3% preoperatively; p<0.001); 96.3% of eyes maintained or reduced medications vs preoperative. Significant IOP and medication reductions occurred across glaucoma subtypes (POAG, PAC, NTG, OHT): 13-22% for IOP (p<0.05 for all) and 42-94% for medication (p<0.05 for all). Favorable safety included few adverse events; stable VF, RNFL, and CCT; and filtering surgery in only 8 eyes (2.9%) over 3 years. Conclusion: In this multicenter cohort from 8 surgeons across Australia, significant IOP and medication reductions were sustained through 3 years after iStent inject implantation with phacoemulsification. Results were favorable across different glaucoma subtypes (including POAG, PAC, NTG, OHT), severities, and surgeons, thereby underscoring the real-world relevance and efficacy of iStent inject implantation for glaucoma treatment.

2.
Clin Ophthalmol ; 14: 3507-3517, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-33149544

RESUMO

PURPOSE: This multicenter study evaluated 2-year effectiveness and safety following implantation of two second-generation trabecular micro-bypass stents (iStent inject ®) with phacoemulsification. MATERIALS AND METHODS: This was a retrospective study of iStent inject implantation with phacoemulsification by nine surgeons across Australia. Eyes had mild to advanced glaucoma (predominantly primary open-angle/POAG, appositional angle-closure/ACG, or normal-tension/NTG) or ocular hypertension (OHT), and cataract. Evaluations included intraocular pressure (IOP); medications; proportions of eyes with 0 or ≥2 medications, reduced/stable medications versus preoperative, and IOP ≤15 mmHg; visual acuity; cup-to-disc ratio (CDR); visual fields (VF); adverse events; and secondary surgery. RESULTS: A total of 340 eyes underwent surgery and had 24-month follow-up data. At 24 months, mean IOP decreased by 16% from 16.4±4.7 mmHg preoperatively to 13.7±3.1 mmHg (p<0.001), and 77% of eyes achieved IOP of ≤15 mmHg versus 49% preoperatively (p<0.001). Mean number of medications decreased by 67% to 0.49±0.95 versus 1.49±1.20 preoperatively (p<0.001), with 74% of eyes medication-free versus 25% preoperatively (p<0.001), and 14% of eyes on ≥2 medications versus 46% preoperatively (p<0.001). Medication burden was reduced or stable in 98% of eyes versus preoperative. Stratified analyses showed significant IOP and medication reductions across glaucoma subtypes (POAG, ACG, NTG, OHT): 13-22% for IOP (p<0.01 for all) and 62-100% for medication (p<0.001 for all). Favorable safety included few adverse events; stable CDR, VF, and visual acuity; and filtering surgery in only 8 eyes (2.4%) over 2 years. CONCLUSION: This 340-eye multicenter dataset provides robust evidence of the safety and efficacy of iStent inject implantation with phacoemulsification, with significant and sustained IOP and medication reductions through 2 years. Results were similarly favorable across glaucoma subtypes (including POAG, ACG, NTG, OHT) and were attained across various glaucoma severities, clinical sites, and surgeons, highlighting the real-world versatility and utility of this treatment modality.

3.
Clin Ophthalmol ; 14: 517-524, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32158184

RESUMO

PURPOSE: Simultaneous cataract and glaucoma surgery has traditionally been challenging for the anterior segment surgeon. The introduction of minimally invasive glaucoma surgery (MIGS) in conjunction with cataract surgery appears safe and effective in lowering intraocular pressure. Although a significant visual impact leading from the combined procedure is unexpected, we aim to describe the refractive outcomes in a cohort of patients undergoing simultaneous cataract removal and iStent inject and discuss the potential implications of combined surgery in patients with co-existent glaucoma. PATIENTS AND METHODS: This is a retrospective consecutive case series inclusive of patients undergoing combined femtosecond laser-assisted cataract surgery and the insertion of two trabecular micro-bypass stents (iStent inject). Visual acuity, refraction and astigmatic vector analysis were collated and analysed from the preoperative and 4 weeks postoperative visits. RESULTS: One hundred and six eyes of 89 patients from 2 surgeons were included in the original cohort. The mean absolute difference from target refraction was 0.36 ± 0.25D. 73.9% of eyes were within ± 0.5D of the refractive target and 98.9% of eyes were within ± 1.00D. 73.8% of eyes had 0.5D or less residual refractive astigmatism following the procedure. CONCLUSION: We present a novel cohort of glaucoma patients undergoing combined trabecular micro-bypass stents (iStent inject) and cataract surgery achieving excellent refractive outcomes. The results of this study indicate that this second-generation device is refractively neutral.

4.
Clin Ophthalmol ; 13: 491-499, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-30936680

RESUMO

PURPOSE: To assess the utility and safety of implanting two second-generation trabecular micro-bypass stents following cataract surgery in eyes with mild to advanced glaucoma or ocular hypertension (OHT). PATIENTS AND METHODS: Retrospective study of iStent®inject trabecular micro-bypass implantation with cataract surgery by five surgeons at five sites in Australia. Eyes had mild to advanced glaucoma (predominantly primary open-angle, appositional angle-closure, or pseudoexfoliative glaucoma) or OHT and cataract requiring surgery. Effectiveness measures included intraocular pressure (IOP); medication burden; and proportions of eyes with no medications, ≥2 medications, stable or decreased medications vs preoperative, and IOP ≤18 mmHg. Safety measures included visual acuity, cup-to-disc ratio (CDR), visual field (VF), complications, adverse events, and secondary surgical interventions. Patients have been followed for 12 months, and follow-up is ongoing. RESULTS: Of the 290 total eyes that underwent surgery, 165 eyes had 12-month outcomes at the time of data collection and are included in this report. In these eyes, mean Month 12 IOP reduced by 23.2% from 18.27±5.41 mmHg preoperatively to 14.04±2.98 mmHg (P<0.001), with 95.8% of eyes achieving Month 12 IOP of ≤18 mmHg vs 60.6% preoperatively. Mean number of medications at 12 months decreased by 71.5%, 0.47±0.95 vs 1.65±1.28 preoperatively; 76.4% of eyes were on zero medications vs 17.6% preoperatively (P<0.001); 14.5% of eyes were on ≥2 medications vs 46.7% preoperatively (P<0.001); and 98.2% of eyes maintained or reduced medications vs their preoperative regimen. Favorable safety included no stent-related intraoperative complications; limited and transient postoperative adverse events; and stable CDR, VF, and visual acuity. Three eyes with more advanced disease underwent additional glaucoma surgeries. CONCLUSION: iStent inject implantation with cataract surgery significantly and safely reduced medications and IOP in eyes with various types and severities of glaucoma within a multicenter, multi-provider, real-life setting.

6.
Ann Clin Microbiol Antimicrob ; 5: 24, 2006 Oct 02.
Artigo em Inglês | MEDLINE | ID: mdl-17014707

RESUMO

BACKGROUND: Brucellosis is an endemic disease present in many countries worldwide, but it is rare in Europe and North America. Nevertheless brucella is included in the bacteria potentially used for bioterrorism. The aim of this study was the investigation of the antibiotic susceptibility profile of brucella isolates from areas of the eastern Mediterranean where it has been endemic. METHODS: The susceptibilities of 74 Brucella melitensis isolates derived from clinical samples (57) and animal products (17) were tested in vitro. The strains originate from Crete (59), Cyprus (10), and Syria (5). MICs of tetracycline, rifampicin, streptomycin, gentamicin, norfloxacin, ciprofloxacin, levofloxacin, trimethoprim/sulfamethoxazole, ampicillin, amoxicillin/clavulanic acid, and erythromycin were detected by E-test method. The NCCLS criteria for slow growing bacteria were considered to interpret the results. RESULTS: All the isolates were susceptible to tetracycline, streptomycin, gentamicin, ciprofloxacin, norfloxacin, and levofloxacin. Two isolates presented reduced susceptibility to rifampicin (MIC value: 1.5 mg/l) and eight to SXT (MIC values: 0.75-1.5 mg/l). Erythromycin had the highest (4 mg/l) MIC90value and both norfloxacin and erythromycin the highest (1.5 mg/l) MIC50 value. CONCLUSION: Brucella isolates remain susceptible in vitro to most antibiotics used for treatment of brucellosis. The establishment of a standardized antibiotic susceptibility method for Brucella spp would be useful for resistance determination in these bacteria and possible evaluation of bioterorism risks.


Assuntos
Antibacterianos/farmacologia , Brucella melitensis/efeitos dos fármacos , Brucelose/microbiologia , Animais , Brucella melitensis/isolamento & purificação , Chipre , Farmacorresistência Bacteriana , Doenças das Cabras/microbiologia , Cabras , Grécia , Humanos , Testes de Sensibilidade Microbiana , Leite/microbiologia , Ovinos , Doenças dos Ovinos/microbiologia , Síria
7.
J Clin Microbiol ; 41(7): 3317-9, 2003 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-12843081

RESUMO

Three different spotted-fever group rickettsiae-Rickettsia conorii, R. massiliae, and R. rhipicephali-were detected and identified by PCR-restriction fragment length polymorphism analysis in Rhipicephalus ticks collected from domestic animals in the Fokida region of Greece, where a high seroprevalence of antibodies to R. conorii was previously demonstrated. The infection rate of ticks was 1.6%. Moreover, R. conorii was isolated from one Rhipicephalus sanguineus tick.


Assuntos
Reação em Cadeia da Polimerase/métodos , Polimorfismo de Fragmento de Restrição , Rickettsia conorii , Rickettsia conorii/classificação , Rickettsia conorii/isolamento & purificação , Carrapatos/microbiologia , Animais , Animais Domésticos/parasitologia , Técnicas de Tipagem Bacteriana , Chlorocebus aethiops , DNA Bacteriano/análise , Grécia , Rickettsia conorii/genética , Rickettsia conorii/crescimento & desenvolvimento , Infestações por Carrapato/parasitologia , Carrapatos/classificação , Células Vero
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...