Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Radiol Prot ; 44(2)2024 Jun 10.
Artigo em Inglês | MEDLINE | ID: mdl-38692264

RESUMO

The role of18F-fluoro-deoxy-glucose in positron emission tomography (PET) imaging is well established in diagnosis and management of cancer patients. Installations of on-site self-shielded mini cyclotrons are increasing. The Dose on Demand Biomarker Generator BG-75 was installed at Metaxa Cancer Hospital, Greece, in May 2021 and is the first hospital-based PET radiopharmaceutical cyclotron in the country. Personnel expected external exposure was established during commissioning; internal exposure is not expected. Personnel dose was estimated with two methods: survey meter measurements in various locations combined with the time spent in each location, and direct measurement using electronic personal dosemeters. Gamma and neutron radiation readings outside the cyclotron vault were at background levels. Inside the cyclotron vault, the highest recorded radiation readings by the target were 18µSv h-1for both gammas and neutrons with cyclotron in operational mode; at one meter, the values were 5µSv h-1and 4µSv h-1, respectively. The annual expected whole body dose per cyclotron operator is 0.6 mSv, and the respective extremity dose 16 mSv. The annual expected whole body and extremity dose for the radiochemist is 0.3 mSv and 25 mSv, respectively. The respective annual dose estimates for the medical physicists are < 1 mSv. The expected personnel doses are well below the regulatory limits and local as low as reasonably achievable (ALARA) levels. With experience and a robust ALARA program, personnel exposure could be further reduced.


Assuntos
Ciclotrons , Exposição Ocupacional , Tomografia por Emissão de Pósitrons , Doses de Radiação , Compostos Radiofarmacêuticos , Grécia , Humanos , Exposição Ocupacional/análise , Compostos Radiofarmacêuticos/análise , Proteção Radiológica , Monitoramento de Radiação/métodos
2.
Radiat Prot Dosimetry ; 167(4): 542-51, 2015 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-25431487

RESUMO

The contribution of radionuclide therapies (RNTs) to effective patient treatment is widely appreciated. The administration of high doses has necessitated investigating the potential radiation hazard to caregivers from patients undergoing RNTs. This work aimed to review the literature regarding measured effective doses to caregivers from such patients. The main selection criterion was the presence of real radiation exposure measurements. The results were categorised according to the treatment protocol and dose parameters. Analysis of the collected data demonstrated that the measured effective dose values were within the dose constraints defined by the International Commission on Radiological Protection, provided that the radiation protection instructions were followed by both patients and caregivers. In conclusion, the radiation risk for caregivers was almost negligible. In this context, treatments could be administered more often on an outpatient basis, once cost-effectiveness criteria were established and radiation protection training and procedures were appropriately applied.


Assuntos
Cuidadores , Doenças Profissionais/etiologia , Exposição à Radiação/efeitos adversos , Lesões por Radiação/etiologia , Humanos , Doenças Profissionais/prevenção & controle , Doses de Radiação , Lesões por Radiação/prevenção & controle , Proteção Radiológica , Espalhamento de Radiação
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...