Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Intervalo de ano de publicação
1.
J Arthroplasty ; 36(9): 3275-3281, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-34088569

RESUMO

BACKGROUND: Two methods for detecting synovial fluids alpha defensins are available: the enzyme-linked immunosorbent assay and the lateral flow test. For both, the proper role and accuracy remain uncertain. The purpose of this study was to assess the accuracy of the matrix-assisted laser desorption/ionization time of flight mass spectrometry (MALDI-TOF MS) for alpha defensin detection in synovial fluids of patients with total knee arthroplasty/total hip arthroplasty failures. The hypothesis was that the alpha defensin measurement through MALDI-TOF MS assay could be a high sensitive and specific test for periprosthetic joint infections (PJI) diagnosis as compared with Musculoskeletal Infection Society (MSIS) criteria. METHODS: The study included 138 patients. The 2018 MSIS criteria were used to diagnose PJIs. Synovial fluids were assessed for routinely synovial fluid tests and alpha defensin measurement through MALDI-TOF MS. Sensitivity, specificity, overall diagnostic accuracy, positive and negative predictive values, receiver operator curves, and area under the curve were calculated. RESULTS: As per the 2018 MSIS criteria, 59 PJIs (43%) and 79 aseptic failures (57%) were diagnosed. The MALDI-TOF MS assay showed an overall accuracy of 94.9%. The sensitivity was 93%, the specificity was 96%, the positive predictive value was 95%, and the negative predictive value was 95%. Receiver operator curves analysis demonstrates an area under the curve of 0.95 (P < .001). CONCLUSION: The MALDI-TOF MS assay showed high sensitivity and specificity for alpha defensin detection in case of total knee arthroplasty/total hip arthroplasty failures. The advantages of the technology, such as the few milliliters of sample needed, the rapidity of obtaining results, and the cost-effectiveness of the procedure could make the MALDI-TOF MS alpha defensin assay a useful and widespread test in clinical practice.


Assuntos
Artrite Infecciosa , Infecções Relacionadas à Prótese , alfa-Defensinas , Biomarcadores , Humanos , Infecções Relacionadas à Prótese/diagnóstico , Sensibilidade e Especificidade , Líquido Sinovial
2.
Preprint em Inglês | medRxiv | ID: ppmedrxiv-20229062

RESUMO

BackgroundThere are conflicting results about the duration of antibodies induced by SARS-CoV-2, but several studies show a rapid decay in a few months after infection. To evaluate antibody decline, we re-evaluated the presence of anti-SARS-CoV-2 antibodies among individuals found seropositive in a first population survey conducted 4 months before. MethodsAll individuals above ten years of age resident in 5 municipalities of the Autonomous Province of Trento, northern Italy, who resulted IgG positive for anti-SARS-CoV-2 nucleocapsid (NC) antibodies in a serosurvey conducted on May 2020 were retested after 4 months. Anti-SARS-CoV-2 antibodies were detected using the Abbott SARS-CoV-2 IgG assay (Abbott Diagnostics, USA) detecting anti-NC antibodies. Samples that gave a negative result were re-tested using the same test plus Liaison SARS-CoV-2 IgG assay (DiaSorin, Italy) to assess anti-spike (S) S1/S2 IgG antibodies. Seroprevalence was calculated as the proportion of positive people on the total number of tested. A neutralizing assay was performed on a subgroup of formerly positives sera using fifty-percent tissue culture infective dose (TCID50) as endpoint dilution to produce a cytopathic effect in 50% of inoculated Vero E6 cells culture. In all the analyses a p value < 0.05 were considered statistically significant. Statistical analysis was performed by STATA version 16.1 (STATA Corp., College Station, Texas, USA). FindingsOverall, 1159 out of 1402 initially anti-NC seropositive participants were enrolled in the study. Of them, 480 (41.1%) became seronegative for anti-NC IgG antibodies. When 479 negative sera were tested for anti-S IgG, 373 samples (77.9%) resulted positives. A functional neutralization assay was performed on 106 sera showing high concordance with anti-S antibodies positivity. InterpretationA decline of anti-NC IgG values was recorded 4 months after the first evaluation. Worth of note, a high proportion of anti-NC seronegative individuals were positive for anti-spike IgG antibodies, which appear to persist longer and to better correlate with neutralization activity.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...