Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Artigo em Inglês | MEDLINE | ID: mdl-38955627

RESUMO

BACKGROUND: There is limited data on cardiac output in patients with small aortic annuli undergoing trans-catheter aortic valve implantation (TAVI) according to the implanted platform of balloon-expandable (BEV) compared to self-expanding valves (SEV). METHODS: This is a retrospective analysis of consecutive patients with severe aortic stenosis and small annuli who underwent successful TAVI. Cardiac output was measured using echocardiography within 4 weeks following TAVI. Data were recorded and analysed by an experienced operator who was not aware of the type of the implanted valve. RESULTS: 138 patients were included in the analysis, of whom 57 % underwent TAVI with BEV. Clinical and echocardiographic characteristics were comparable between the two platforms, except for more frequent previous cardiac surgery and smaller indexed aortic valve in the BEV group. There was no relationship between computed tomography-derived aortic annulus area and cardiac output post TAVI. When compared to patients who underwent TAVI with BEV, those with SEV had larger cardiac output [mean difference - 0.50 l/min, 95 % CI (-0.99, -0.01)] and cardiac index [mean difference - 0.20 l/min/m2, 95 % CI (-0.47, 0.07)], although the latter did not reach statistical significance. Unlike patients with small body surface area, in those with large body surface area both cardiac output and cardiac index were statistically larger in patients who underwent SEV compared to BEV. CONCLUSION: Cardiac output, as measured by echocardiography, was larger in patients with small annuli who underwent TAVI procedure with SEV compared to BEV. Such difference was more evident in patients with large body surface area.

2.
Heart Lung Circ ; 32(12): 1489-1499, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37993343

RESUMO

BACKGROUND: Transvalvular flow rate (TFR) represents a better reflection of transvalvular flow than the stroke volume index (SVi), and has recently emerged as a useful prognostic tool in patients undergoing surgical aortic valve replacement. There is a paucity of data investigating the role of TFR and its relationship with other clinical or echocardiographic factors in patients undergoing transcatheter aortic valve implantation (TAVI). METHOD: This was a retrospective single-centre study of 629 consecutive patients who underwent TAVI between March 2009 and September 2020. Pre-TAVI low TFR was defined as <200 c/s. The primary study end point was all-cause mortality. RESULTS: Low TFR was observed in 41.8% (263/629) of included patients and was associated with increasing age, low body surface area, hypertension, diabetes, atrial fibrillation, left ventricular (LV) dysfunction, and significant mitral regurgitation. LV function status and severity of aortic valve disease were independent predictors of low TFR. Low TFR was significantly associated with long-term all-cause mortality even after adjustment for other risk factors (adjusted hazard ratio [aHR] 1.44; 95% confidence interval [CI] 1.02-2.03; p=0.038). When data were stratified according to SVi, low TFR was an independent predictor of long-term all-cause mortality in patients with normal SVi (aHR 1.98; 95% CI 1.06-3.69; p=0.032) but not in patients with low SVi (HR 1.23; 95% CI 0.71-2.11; p=0.46; p=0.016 for interaction). CONCLUSIONS: Low TFR is common in patients undergoing TAVI and is an independent predictor of all-cause mortality, particularly in patients with normal SVi.


Assuntos
Estenose da Valva Aórtica , Substituição da Valva Aórtica Transcateter , Disfunção Ventricular Esquerda , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/complicações , Estudos Retrospectivos , Resultado do Tratamento , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Função Ventricular Esquerda , Volume Sistólico , Índice de Gravidade de Doença
3.
Echocardiography ; 37(12): 2163-2167, 2020 12.
Artigo em Inglês | MEDLINE | ID: mdl-33219574

RESUMO

Inadvertent endocardial lead malposition is recognized as a rare incident which is usually underreported and if recognized during implantation can be easily corrected. This phenomenon is caused by the ventricular lead unintentionally crossing a pre-existing patent foremen ovale, septal defects (atrial or ventricular) or directly from the aorta via an accidental subclavian puncture resulting in the lead implanting into the left ventricle. While this is a rare occurrence we report, the incidental finding of pacemaker lead malposition during a routine follow-up transthoracic echocardiogram and the benefits of three-dimensional transesophageal echocardiography in this patient prior to lead extraction.


Assuntos
Ventrículos do Coração , Marca-Passo Artificial , Ecocardiografia , Ecocardiografia Transesofagiana , Átrios do Coração , Ventrículos do Coração/diagnóstico por imagem , Humanos , Marca-Passo Artificial/efeitos adversos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...