Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Bull Environ Contam Toxicol ; 95(6): 790-5, 2015 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-26395356

RESUMO

Immobilisation of heavy metals in a 30-year old active scrap metal yard soil using three waste materials, namely coconut tree sawdust (CTS), sugarcane bagasse (SB) and eggshell (ES) was investigated. The contaminated soil was amended with amendments at application rates of 0 %, 1 % and 3 % (w/w). The effects of amendments on metal accumulation in water spinach (Ipomoea aquatica) and soil metal bioavailability were studied in a pot experiment. All amendments increased biomass yield and reduced metal accumulation in the plant shoots. The bioconcentration factor and translocation factor values of the metals were in the order of Zn > Cu > Pb. The addition of ES, an alternative source of calcium carbonate (CaCO3), has significantly increased soil pH and resulted in marked reduction in soil metal bioavailability. Therefore, CTS, SB and ES are promising low-cost immobilising agents to restore metal contaminated land.


Assuntos
Metais Pesados/análise , Poluentes do Solo/análise , Solo/química , Resíduos/análise , Animais , Biodegradação Ambiental , Disponibilidade Biológica , Biomassa , Cocos/química , Casca de Ovo/química , Ipomoea/metabolismo , Brotos de Planta/química , Saccharum/química , Poluentes do Solo/química , Zinco
2.
Talanta ; 87: 230-4, 2011 Dec 15.
Artigo em Inglês | MEDLINE | ID: mdl-22099672

RESUMO

A new cobalt(II) ion selective electrode based on palladium(II) dichloro acetylthiophene fenchone azine(I) has been developed. The best membrane composition is found to be 10:60:10:21.1 (I)/PVC/NaTPB/DOP (w/w). The electrode exhibits a Nerstian response in the range of 1.0 × 10(-1)-1.0 × 10(-6)M with a detection limit and slope of 8.0 × 10(-7)M and 29.6 ± 0.2 mV per decade respectively. The response time is within the range of 20-25s and can be used for a period of up to 4 months. The electrode developed reveals good selectivity for cobalt(II) and could be used in pH range of 3-7. The electrode has been successfully used in the determination of cobalt(II) in water samples.


Assuntos
Cobalto/análise , Técnicas Eletroquímicas/instrumentação , Norbornanos/química , Paládio/química , Tiofenos/química , Poluentes Químicos da Água/análise , Canfanos , Eletrodos , Hidrocarbonetos Clorados/química , Íons/análise , Membranas Artificiais , Sensibilidade e Especificidade , Água/análise
3.
Talanta ; 71(1): 452-5, 2007 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-19071326

RESUMO

This paper describes the preparation of and experimentation undertaken by heterogeneous chitosan membrane as ion selective electrode for glutamate ion. The linearity response was obtained in the range of 1.0x10(-5) to 1.0x10(-1)M with a detection limit of 1.0x10(-6)M. The performance of the electrode was found in the pH range of 4.0-8.0 at temperature 25+/-3 degrees C. The response time was at 5-35s and was useful for a period of more than 4 months. The selectivity values towards some anions indicates good selectivity over a number of interfering anions. No significant improvement of membrane performance over additional of plasticizers such as 2-NPOE, BEHA and DOPP. The electrodes gave sufficient Nernstian responses with the exception of membrane with 2-NPOE.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...