Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Diabetes Res ; 2021: 5544599, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34195292

RESUMO

OBJECTIVES: To evaluate the utility of fetal abdominal wall thickness (AWT) for predicting intrapartum complications amongst mothers with pregestational type 2 diabetes. METHODS: This was a historical cohort study of pregnant mothers with pregestational type 2 diabetes delivering at a Canadian tertiary-care center between January 1, 2014, and December 31, 2018. Delivery records were reviewed to collect information about demographics and peripartum complications. Stored fetal ultrasound images from 36 weeks' gestation were reviewed to collect fetal biometry and postprocessing measurement of AWT performed in a standardized fashion by 2 blinded and independent observers. The relationship between fetal AWT was then correlated with risk of intrapartum complications including emergency Caesarean section (CS) and shoulder dystocia. RESULTS: 216 pregnant women with type 2 diabetes had planned vaginal deliveries and were eligible for inclusion. Mean maternal age was 31.3 years, and almost all were overweight or obese at the time of delivery (96.8%). Overall, the incidence of shoulder dystocia and emergency intrapartum CS was 7.4% and 17.6%, respectively. There was no difference in mean fetal AWT between those having a spontaneous vaginal delivery (8.2 mm (95% CI 7.9-8.5)) and those needing emergency intrapartum CS (8.1 mm (95% CI 7.4-8.8); p = 0.71) or shoulder dystocia (8.7 mm (95% CI 7.9-9.5); p = 0.23). There was strong interobserver correlation of AWT measurements (r = 0.838; p < 0.00001). The strongest association with intrapartum complications was birthweight (p = 0.003): with birthweight > 4000 grams, the relative risk of shoulder dystocia or CS is 2.75 (95% CI 1.74-4.36; p < 0.001). CONCLUSIONS: There was no obvious benefit of AWT measurement at 36 weeks for predicting shoulder dystocia or intrapartum CS amongst women with type 2 diabetes in our population. The strongest predictor of intrapartum complications remained birthweight, and so studies for improving estimation of fetal weight and evaluating the role of intrapartum ultrasound for predicting risk of delivery complications are still needed.


Assuntos
Parede Abdominal/diagnóstico por imagem , Cesárea/estatística & dados numéricos , Diabetes Mellitus Tipo 2/epidemiologia , Feto/diagnóstico por imagem , Gravidez em Diabéticas/epidemiologia , Distocia do Ombro/epidemiologia , Adulto , Peso ao Nascer , Estudos de Coortes , Emergências , Feminino , Macrossomia Fetal/epidemiologia , Idade Gestacional , Humanos , Manitoba/epidemiologia , Gravidez , Ultrassonografia Pré-Natal
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...