Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Thorac Cardiovasc Surg ; 69(4): 362-365, 2021 06.
Artigo em Inglês | MEDLINE | ID: mdl-32898891

RESUMO

The frozen elephant trunk (FET) procedure enables easier replacement of the entire aortic arch because it does not require reaching the distal part of the left subclavian artery (LSCA). However, it requires additional management for reconstruction of the LSCA, which is associated with bleeding events. However, the fenestrated FET technique confers a risk of endoleakage from the fenestration site. We report our unique novel technique in which the proximal side of the hybrid stent graft is cut into V-shape around the subclavian artery and sutured continuously around the orifice of the subclavian artery during aortic stump fixation.


Assuntos
Aorta Torácica/cirurgia , Aneurisma da Aorta Torácica/cirurgia , Dissecção Aórtica/cirurgia , Implante de Prótese Vascular , Procedimentos Endovasculares , Artéria Subclávia/cirurgia , Técnicas de Sutura , Idoso , Dissecção Aórtica/diagnóstico por imagem , Aorta Torácica/diagnóstico por imagem , Aneurisma da Aorta Torácica/diagnóstico por imagem , Prótese Vascular , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/instrumentação , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/instrumentação , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Desenho de Prótese , Stents , Artéria Subclávia/diagnóstico por imagem , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...