Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Avicenna J Med ; 13(3): 182-186, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-37799184

RESUMO

Background Aim of this study is to investigate whether end-tidal carbon dioxide (ETCO 2 ) values can be used instead of partial pressure of carbon dioxide (PaCO 2 ) values in guiding treatment, and determining treatment benefits in patients that received a pre-diagnosis of chronic obstructive pulmonary disease (COPD) exacerbation at the emergency department. Methods This observational prospective study was conducted with patients who presented to the emergency department with the complaint of shortness of breath and were diagnosed with COPD exacerbation. ETCO 2 was measured with the sidestream method during blood gas analysis in patients with indications for this analysis. Measurements were repeated at hour 1 after treatment. Results The study included a total of 121 cases. There was a positive correlation between the PaCO 2 and ETCO 2 values measured before and after treatment ( r = 0.736, p < 0.01 and r = 0.883, p < 0.01, respectively). High ETCO 2 values were accompanied by high PaCO 2 values. When the measurements before and after treatment were evaluated using the Bland-Altman method, most of the result were within the limits of agreement (-4.9 and +31.4/- 2.6 and +9.4), with mean differences being calculated as 13.2 and 8.4, respectively. Conclusions Although ETCO 2 and PaCO 2 were statistically consistent according to the results of our study, due to the high averages of differences between these two parameters, the ETCO 2 value has limited clinical use in COPD cases compared to PaCO 2 . However, high ETCO 2 values may indicate that noninvasive mechanical ventilation should be included in the treatment of COPD cases without waiting for the results of blood gas analysis, and they can also be when needed for inpatient treatment.

2.
Kaohsiung J Med Sci ; 31(8): 432-6, 2015 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-26228283

RESUMO

Diagnosis and measuring the level of increase in intracranial pressure (ICP) is critical, especially for the management of trauma patients in the emergency department and intensive care unit. However, measurements are operator-dependent as in all of the sonographic diagnoses. The aim of this study is to assess the operator variations in the measurement of optic nerve sheath diameter (ONSD). There were four emergency medicine specialists involved in the study. Each had at least 1 year of experience of ultrasound scans and performed at least 25 prior ocular scans examining the ONSD. Two measurements were made 1 week apart from both axial and longitudinal planes. Sixty healthy adults were involved in the study and every investigator obtained four measurements from each. Intra-interobserver reliabilities were tested. The investigators performed 60 ocular ultrasounds on individual healthy adults and obtained two measurements in axial and longitudinal planes 1 week apart. Therefore, 960 measurements were analyzed. The levels of compatibilities for most of the measurements were found at acceptable levels statistically. However, it is not possible to say that there was a perfect compatibility among the sonographers according to the previously conducted reliability studies of ultrasound measurements. According to our results, it is hard to say that sonographic measurement of the ONSD is a highly reliable method both in longitudinal and transverse planes.


Assuntos
Nervo Óptico/diagnóstico por imagem , Ultrassom/métodos , Adulto , Humanos , Masculino , Variações Dependentes do Observador , Nervo Óptico/patologia , Reprodutibilidade dos Testes , Ultrassonografia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...