Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 32
Filtrar
1.
Catheter Cardiovasc Interv ; 87(7): E248-60, 2016 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-26649651

RESUMO

BACKGROUND: Historically, percutaneous coronary intervention (PCI) of bifurcation lesions was associated with worse procedural and clinical outcomes when compared with PCI of non-bifurcation lesions. Newer generation drug-eluting stents (DES) might improve long-term clinical outcomes after bifurcation PCI. METHODS AND RESULTS: The LEADERS trial was a 10-center, assessor-blind, non-inferiority, all-comers trial, randomizing 1,707 patients to treatment with a biolimus A9(TM) -eluting stent (BES) with an abluminal biodegradable polymer or a sirolimus-eluting stent (SES) with a durable polymer (ClinicalTrials.gov Identifier: NCT00389220). Five-year clinical outcomes were compared between patients with and without bifurcation lesions and between BES and SES in the bifurcation lesion subgroup. There were 497 (29%) patients with at least 1 bifurcation lesion (BES = 258; SES = 239). At 5-year follow-up, the composite endpoint of cardiac death, myocardial infarction (MI) and clinically-indicated (CI) target vessel revascularization (TVR) was observed more frequently in the bifurcation group (26.6% vs. 22.4%, P = 0.049). Within the bifurcation lesion subgroup, no differences were observed in (cardiac) death or MI rates between BES and SES. However, CI target lesion revascularization (TLR) (10.1% vs. 15.9%, P = 0.0495), and CI TVR (12.0% vs. 19.2%, P = 0.023) rates were significantly lower in the BES group. Definite/probable stent thrombosis (ST) rate was numerically lower in the BES group (3.1% vs. 5.9%, P = 0.15). Very late (>1 year) definite/probable ST rates trended to be lower with BES (0.4% vs. 3.1%, P = 0.057). CONCLUSIONS: In the treatment of bifurcation lesions, use of BES led to superior long-term efficacy compared with SES. Safety outcomes were comparable between BES and SES, with an observed trend toward a lower rate of very late definite/probable ST between 1 and 5 years with the BES. © 2015 Wiley Periodicals, Inc.


Assuntos
Fármacos Cardiovasculares/administração & dosagem , Doença da Artéria Coronariana/terapia , Stents Farmacológicos , Intervenção Coronária Percutânea/instrumentação , Sirolimo/análogos & derivados , Idoso , Doença da Artéria Coronariana/diagnóstico , Doença da Artéria Coronariana/mortalidade , Trombose Coronária/etiologia , Europa (Continente) , Feminino , Humanos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/etiologia , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/mortalidade , Estudos Prospectivos , Desenho de Prótese , Fatores de Risco , Sirolimo/administração & dosagem , Fatores de Tempo , Resultado do Tratamento
2.
Am J Cardiovasc Dis ; 4(2): 87-99, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-25006536

RESUMO

OBJECTIVES: Few data is available comparing Edwards SAPIEN XT - SXT (Edwards Lifesciences, Irvine, California) with Medtronic CoreValve - CoV (Medtronic Inc., Minneapolis, Minnesota) in patients with severe aortic stenosis undergoing transcatheter aortic valve replacement (TAVR). METHODS: We selected consecutive patients undergoing transfemoral TAVR with SXT or CoV at our Institution. Main outcomes were Valve Academic Research Consortium (VARC)-combined safety endpoints. RESULTS: A total of 100 patients (SXT, n=50 versus CoV, n=50) were analyzed. Both SXT and CoV showed good device success rates (98% versus 90%, p=0.20). SXT versus CoV reduced the occurrence of paravalvular regurgitation after TAVR (26% versus 90%, p<0.0001) though not affecting the rate of moderate/severe regurgitation (p=0.20). SXT versus CoV required less frequently a permanent pacemaker after TAVR (8% versus 38%, p<0.0001). In-hospital major vascular complications (8% versus 4%, p>0.99), life-threatening bleedings (2% versus 4%, p>0.99), stroke (4% versus 6%, p>0.99) and death (6% versus 2%, p>0.99) did not differ between SXT and CoV. However, safety endpoints favored SXT (17% versus 34.6%, p=0.01), due to a numerically higher incidence of ischemic stroke and Acute Kidney Injury Stage 3 after CoV. At multivariate analysis, TAVR with SXT (odds ratio=0.21, 95% confidence intervals [0.05-0.84], p=0.03) was predictive of fewer adverse events. CONCLUSIONS: Transcatheter valve implantation with Edwards SAPIEN XT was associated with lower VARC-combined safety endpoints as compared with Medtronic CoreValve. More extensive cohorts are needed to confirm these results.

3.
JACC Cardiovasc Interv ; 6(8): 777-89, 2013 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-23968698

RESUMO

OBJECTIVES: This study sought to report the final 5 years follow-up of the landmark LEADERS (Limus Eluted From A Durable Versus ERodable Stent Coating) trial. BACKGROUND: The LEADERS trial is the first randomized study to evaluate biodegradable polymer-based drug-eluting stents (DES) against durable polymer DES. METHODS: The LEADERS trial was a 10-center, assessor-blind, noninferiority, "all-comers" trial (N = 1,707). All patients were centrally randomized to treatment with either biodegradable polymer biolimus-eluting stents (BES) (n = 857) or durable polymer sirolimus-eluting stents (SES) (n = 850). The primary endpoint was a composite of cardiac death, myocardial infarction (MI), or clinically indicated target vessel revascularization within 9 months. Secondary endpoints included extending the primary endpoint to 5 years and stent thrombosis (ST) (Academic Research Consortium definition). Analysis was by intention to treat. RESULTS: At 5 years, the BES was noninferior to SES for the primary endpoint (186 [22.3%] vs. 216 [26.1%], rate ratio [RR]: 0.83 [95% confidence interval (CI): 0.68 to 1.02], p for noninferiority <0.0001, p for superiority = 0.069). The BES was associated with a significant reduction in the more comprehensive patient-orientated composite endpoint of all-cause death, any MI, and all-cause revascularization (297 [35.1%] vs. 339 [40.4%], RR: 0.84 [95% CI: 0.71 to 0.98], p for superiority = 0.023). A significant reduction in very late definite ST from 1 to 5 years was evident with the BES (n = 5 [0.7%] vs. n = 19 [2.5%], RR: 0.26 [95% CI: 0.10 to 0.68], p = 0.003), corresponding to a significant reduction in ST-associated clinical events (primary endpoint) over the same time period (n = 3 of 749 vs. n = 14 of 738, RR: 0.20 [95% CI: 0.06 to 0.71], p = 0.005). CONCLUSIONS: The safety benefit of the biodegradable polymer BES, compared with the durable polymer SES, was related to a significant reduction in very late ST (>1 year) and associated composite clinical outcomes. (Limus Eluted From A Durable Versus ERodable Stent Coating [LEADERS] trial; NCT00389220).


Assuntos
Implantes Absorvíveis , Fármacos Cardiovasculares/administração & dosagem , Doença da Artéria Coronariana/terapia , Trombose Coronária/prevenção & controle , Stents Farmacológicos , Intervenção Coronária Percutânea/instrumentação , Polímeros , Sirolimo/análogos & derivados , Idoso , Distribuição de Qui-Quadrado , Doença da Artéria Coronariana/diagnóstico , Doença da Artéria Coronariana/mortalidade , Trombose Coronária/diagnóstico , Trombose Coronária/etiologia , Trombose Coronária/mortalidade , Europa (Continente) , Feminino , Humanos , Análise de Intenção de Tratamento , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/etiologia , Infarto do Miocárdio/mortalidade , Infarto do Miocárdio/prevenção & controle , Razão de Chances , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/mortalidade , Modelos de Riscos Proporcionais , Estudos Prospectivos , Desenho de Prótese , Fatores de Risco , Sirolimo/administração & dosagem , Fatores de Tempo , Resultado do Tratamento
4.
Int J Cardiol ; 166(3): 652-7, 2013 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-22197118

RESUMO

BACKGROUND: TAVI is a novel treatment option for patients at too high risk for surgery. Risk scores for surgical valve replacement failed to accurately predict outcomes after TAVI and alternative risk parameters are lacking so far. OBJECTIVE: We evaluated the CT-derived aortic valve calcification score as a predictor for outcome during and after TAVI. METHODS: Transfemoral TAVI using the CoreValve device was performed in 68 patients, in whom the aortic valve calcium score was determined from preprocedural 64-sclice ECG gated CT-scans. RESULTS: 30-day MACE rate (death, stroke, MI) was 10.3%, 1-year mortality was 11.8%. Using linear regression analysis the aortic valve calcium score was the only significant predictor for 30-day MACE and for 1-year mortality and was also associated with the incidence and severity of post procedural aortic regurgitation (r=0.33, p<0.05). Patients withvalve calcium scores >750 had a significant lower 1-year survival rate compared to patients with scores <750 (58% vs. 98%, p<0.05). The aortic valve calcium score is also inversely associated with the absolute improvement of NYHA-class after TAVI (regression coefficient=-0.43, p<0.02). CONCLUSION: The degree of aortic valve calcification is associated with post procedural aortic regurgitation, procedural complications, 1-year mortality and with the degree of functional improvement of patients who underwent TAVI using the CoreValve device. Due to the fact that the aortic valve calcium score can be determined from CT-datasets that are used for preprocedural planning, this parameter may be incorporated in the general work up and may be used for risk stratification and patient selection.


Assuntos
Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Valva Aórtica/patologia , Calcinose/diagnóstico por imagem , Calcinose/cirurgia , Cateterismo Cardíaco/métodos , Implante de Prótese de Valva Cardíaca/métodos , Índice de Gravidade de Doença , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Feminino , Seguimentos , Humanos , Masculino , Tomografia Computadorizada Multidetectores/métodos , Valor Preditivo dos Testes , Resultado do Tratamento
5.
Lancet ; 378(9807): 1940-8, 2011 Dec 03.
Artigo em Inglês | MEDLINE | ID: mdl-22075451

RESUMO

BACKGROUND: The effectiveness of durable polymer drug-eluting stents comes at the expense of delayed arterial healing and subsequent late adverse events such as stent thrombosis (ST). We report the 4 year follow-up of an assessment of biodegradable polymer-based drug-eluting stents, which aim to improve safety by avoiding the persistent inflammatory stimulus of durable polymers. METHODS: We did a multicentre, assessor-masked, non-inferiority trial. Between Nov 27, 2006, and May 18, 2007, patients aged 18 years or older with coronary artery disease were randomly allocated with a computer-generated sequence to receive either biodegradable polymer biolimus-eluting stents (BES) or durable polymer sirolimus-eluting stents (SES; 1:1 ratio). The primary endpoint was a composite of cardiac death, myocardial infarction, or clinically-indicated target vessel revascularisation (TVR); patients were followed-up for 4 years. Analysis was by intention to treat. This trial is registered with ClinicalTrials.gov, number NCT00389220. FINDINGS: 1707 patients with 2472 lesions were randomly allocated to receive either biodegradable polymer BES (857 patients, 1257 lesions) or durable polymer SES (850 patients, 1215 lesions). At 4 years, biodegradable polymer BES were non-inferior to durable polymer SES for the primary endpoint: 160 (18·7%) patients versus 192 (22·6%) patients (rate ratios [RR] 0·81, 95% CI 0·66-1·00, p for non-inferiority <0·0001, p for superiority=0·050). The RR of definite ST was 0·62 (0·35-1·08, p=0·09), which was largely attributable to a lower risk of very late definite ST between years 1 and 4 in the BES group than in the SES group (RR 0·20, 95% CI 0·06-0·67, p=0·004). Conversely, the RR of definite ST during the first year was 0·99 (0·51-1·95; p=0·98) and the test for interaction between RR of definite ST and time was positive (p(interaction)=0·017). We recorded an interaction with time for events associated with ST but not for other events. For primary endpoint events associated with ST, the RR was 0·86 (0·41-1·80) during the first year and 0·17 (0·04-0·78) during subsequent years (p(interaction)=0·049). INTERPRETATION: Biodegradable polymer BES are non-inferior to durable polymer SES and, by reducing the risk of cardiac events associated with very late ST, might improve long-term clinical outcomes for up to 4 years compared with durable polymer SES. FUNDING: Biosensors Europe SA, Switzerland.


Assuntos
Implantes Absorvíveis , Doença da Artéria Coronariana/terapia , Stents Farmacológicos , Polímeros , Sirolimo/análogos & derivados , Seguimentos , Humanos , Trombose/etiologia
6.
EuroIntervention ; 7(7): 789-95, 2011 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-22027687

RESUMO

AIMS: The current study reports clinical outcomes at three year follow-up of the LEADERS clinical trial which was the first all-comers trial comparing a new generation biodegradable polymer biolimus drug-eluting stent (BES) with the first generation permanent polymer sirolimus-eluting stent (SES). METHODS AND RESULTS: One thousand seven hundred and seven patients were randomised to unrestricted use of BES (n=857) or SES (n=850) in an all-comers population. Three year follow-up was available in 95% of the patients, 812 treated with BES and 809 treated with SES. At three years, BES remains non-inferior to SES for the primary endpoint of major adverse cardiac events (composite of cardiac death, myocardial infarction (MI), or clinically-indicated target vessel revascularisation (CI-TVR) (BES 15.7% versus SES 19%; HR 0.82 CI 0.65-1.03; p=0.09). The MACE Kaplan Meier event curves increasingly diverge with the difference in events increasing from 1.4% to 2.4% and 3.3% at 1, 2 and 3 years, respectively in favour of BES. The rate of cardiac death was non-significantly lower 4.2% versus 5.2% (HR=0.81 CI 0.52-1.26; p=0.34) and the rate of myocardial infarction was equivalent 7.2% versus 7.1% (HR 1.01 CI 0.70-1.44; p=0.97) for BES versus SES, respectively. Thus BES was non-inferior to SES in all the safety endpoints. Clinically-indicated TVR occurred in 9.4% of BES treated patients versus 11.1% of SES treated patients (HR 0.84 CI 0.62-1.13; p=0.25). Rates of definite stent thrombosis were 2.2% for BES and 2.9% for SES (HR 0.78 CI 0.43-1.43; p=0.43), with the event rate increase of 0.2% from one to three years for BES and 0.9% for SES. For patients presenting with ST-elevation myocardial infarction BES was superior to SES in reducing MACE. CONCLUSIONS: The findings of the three year follow-up support the claim that the biodegradable polymer biolimus-eluting stent has equivalent safety and efficacy to permanent polymer sirolimus-eluting stent in an all-comers patient population. Its performance is superior in some subpopulations such as in ST-elevation MI patients and event rates for BES are overall lower than for SES with a trend toward increasing divergence of outcomes over three years.


Assuntos
Implantes Absorvíveis , Angioplastia Coronária com Balão/instrumentação , Fármacos Cardiovasculares/administração & dosagem , Doença da Artéria Coronariana/terapia , Stents Farmacológicos , Polímeros , Sirolimo/análogos & derivados , Idoso , Angioplastia Coronária com Balão/efeitos adversos , Angioplastia Coronária com Balão/mortalidade , Distribuição de Qui-Quadrado , Doença da Artéria Coronariana/mortalidade , Quimioterapia Combinada , Europa (Continente) , Feminino , Humanos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/etiologia , Infarto do Miocárdio/prevenção & controle , Inibidores da Agregação Plaquetária/uso terapêutico , Modelos de Riscos Proporcionais , Desenho de Prótese , Medição de Risco , Fatores de Risco , Sirolimo/administração & dosagem , Trombose/etiologia , Trombose/prevenção & controle , Fatores de Tempo , Resultado do Tratamento
7.
EuroIntervention ; 7(5): 605-13, 2011 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-21930465

RESUMO

BACKGROUND: The SYNTAX score (SXscore) has been shown to be an effective predictor of clinical outcomes in patients undergoing percutaneous coronary intervention (PCI). METHODS AND RESULTS: The SXscore was prospectively collected in 1,397 of the 1,707 patients enrolled in the "all-comers" LEADERS trial (patients post-surgical revascularisation were excluded). Post hoc analysis was performed by stratifying clinical outcomes at two-year follow-up, according to one of three SXscore tertiles: SXlow ≤8 (n=464), 816 (n=461). At two-year follow-up the rate of major adverse cardiovascular events was 18.4%, 12.0% and 9.4% in the SXhigh, SXmid, and SXlow tertile, respectively (HR 1.45; CI 1.21-1.74; p<0.01). There was a significantly higher rate of cardiac death in patients in the highest SXscore tertile (7% SXhigh versus 2.4% SXmid versus 1.8% SXlow; HR 2.22; CI 1.5-3.27; p<0.001). Within the SXhigh tertile the rate of cardiac death was significantly lower in patients treated with the biolimus-eluting stent compared with the sirolimus-eluting stent (4.7% versus 9.6%, HR 0.48; CI 0.23-0.99; p=0.046). CONCLUSIONS: The SXscore when applied to an "all-comers" patient population allows for prospective risk stratification of patients undergoing PCI up to two years follow-up. In addition, the SXscore appears to separate the performance of devices in high risk patient groups.


Assuntos
Angioplastia Coronária com Balão/instrumentação , Fármacos Cardiovasculares/administração & dosagem , Doença da Artéria Coronariana/terapia , Stents Farmacológicos , Cardiopatias/prevenção & controle , Polímeros , Sirolimo/análogos & derivados , Idoso , Angioplastia Coronária com Balão/efeitos adversos , Angioplastia Coronária com Balão/mortalidade , Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico , Doença da Artéria Coronariana/mortalidade , Reestenose Coronária/etiologia , Reestenose Coronária/prevenção & controle , Feminino , Cardiopatias/diagnóstico , Cardiopatias/etiologia , Cardiopatias/mortalidade , Humanos , Masculino , Pessoa de Meia-Idade , Modelos de Riscos Proporcionais , Estudos Prospectivos , Desenho de Prótese , Medição de Risco , Fatores de Risco , Sirolimo/administração & dosagem , Trombose/etiologia , Trombose/prevenção & controle , Fatores de Tempo , Tomografia de Coerência Óptica , Resultado do Tratamento
8.
JACC Cardiovasc Interv ; 4(8): 887-95, 2011 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-21851904

RESUMO

OBJECTIVES: This study sought to investigate safety and efficacy of biolimus-eluting stents (BES) with biodegradable polymer as compared with sirolimus-eluting stents (SES) with durable polymer through 2 years of follow-up. BACKGROUND: BES with a biodegradable polymer provide similar efficacy and safety as SES with a durable polymer at 9 months. Clinical outcomes beyond the period of biodegradation of the polymer used for drug release and after discontinuation of dual antiplatelet therapy are of particular interest. METHODS: A total of 1,707 patients were randomized to unrestricted use of BES (n = 857) or SES (n = 850) in an all-comers patient population. RESULTS: At 2 years, BES remained noninferior compared with SES for the primary endpoint, which was a composite of cardiac death, myocardial infarction, or clinically indicated target vessel revascularization (BES 12.8% vs. SES 15.2%, hazard ratio [HR]: 0.84, 95% confidence interval [CI]: 0.65 to 1.08, p(noninferiority) < 0.0001, p(superiority) = 0.18). Rates of cardiac death (3.2% vs. 3.9%, HR: 0.81, 95% CI: 0.49 to 1.35, p = 0.42), myocardial infarction (6.3% vs. 5.6%, HR: 1.12, 95% CI: 0.76 to 1.65, p = 0.56), and clinically indicated target vessel revascularization (7.5% vs. 8.6%, HR: 0.86, 95% CI: 0.62 to 1.20, p = 0.38) were similar for BES and SES. The rate of definite stent thrombosis through 2 years was 2.2% for BES and 2.5% for SES (p = 0.73). For the period between 1 and 2 years, event rates for definite stent thrombosis were 0.2% for BES and 0.5% for SES (p = 0.42). After discontinuation of dual antiplatelet therapy, no very late definite stent thrombosis occurred in the BES group. CONCLUSIONS: At 2 years of follow-up, the unrestricted use of BES with a biodegradable polymer maintained a similar safety and efficacy profile as SES with a durable polymer. (Limus Eluted From a Durable Versus Erodable Stent Coating [LEADERS]; NCT00389220).


Assuntos
Implantes Absorvíveis , Angioplastia Coronária com Balão/instrumentação , Fármacos Cardiovasculares/administração & dosagem , Doença da Artéria Coronariana/terapia , Stents Farmacológicos , Sirolimo/análogos & derivados , Idoso , Angioplastia Coronária com Balão/efeitos adversos , Angioplastia Coronária com Balão/mortalidade , Distribuição de Qui-Quadrado , Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/mortalidade , Quimioterapia Combinada , Europa (Continente) , Feminino , Seguimentos , Humanos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/etiologia , Inibidores da Agregação Plaquetária/uso terapêutico , Modelos de Riscos Proporcionais , Desenho de Prótese , Medição de Risco , Fatores de Risco , Sirolimo/administração & dosagem , Taxa de Sobrevida , Trombose/etiologia , Fatores de Tempo , Resultado do Tratamento
9.
J Am Coll Cardiol ; 57(22): 2221-32, 2011 May 31.
Artigo em Inglês | MEDLINE | ID: mdl-21616282

RESUMO

OBJECTIVES: The aim of this study was to investigate the impact of patient and lesion complexity on outcomes with newer-generation zotarolimus-eluting stents (ZES) and everolimus-eluting stents (EES). BACKGROUND: Clinical and angiographic outcomes of newer-generation stents have not been described among complex patients. METHODS: Patients enrolled in the RESOLUTE All Comers trial (A Randomized Comparison of a Zotarolimus-Eluting Stent With an Everolimus-Eluting Stent for Percutaneous Coronary Intervention) were stratified into "complex" and "simple." RESULTS: Of 2,292 patients, 1,520 (66.3%) were complex and treated with ZES (n = 764) or EES (n = 756). Event rates were higher among complex patients, and results did not differ between ZES and EES, regardless of complexity. At 1 year, target lesion failure was 8.9% in ZES- and 9.7% in EES-treated complex patients (p = 0.66) and 6.8% in ZES- and 5.7% in EES-treated simple patients (p = 0.55). Rates of cardiac death (1.3% vs. 2.2%, p = 0.24), target-vessel myocardial infarction (4.3% vs. 4.4%, p = 0.90), and clinically indicated target lesion revascularization (4.4% vs. 4.0%, p = 0.80) were similar for both stent types among complex patients. Definite or probable stent thrombosis occurred in 20 (1.3%) complex patients with no difference between ZES (1.7%) and EES (0.9%, p = 0.26). Angiographic follow-up showed similar results for ZES and EES in terms of in-stent percentage diameter stenosis (22.2 ± 15.4% vs. 21.4 ± 15.8%, p = 0.67) and in-segment binary restenosis (6.6% vs. 8.0%, p = 0.82) in the complex group. CONCLUSIONS: In this all-comers randomized trial, major adverse cardiovascular events were more frequent among complex than simple patients. The newer-generation ZES and EES proved to be safe and effective, regardless of complexity, with similar clinical and angiographic outcomes for both stent types through 1 year. (RESOLUTE-III All Comers Trial: A Randomized Comparison of a Zotarolimus-Eluting Stent With an Everolimus-Eluting Stent for Percutaneous Coronary Intervention; NCT00617084).


Assuntos
Angioplastia Coronária com Balão , Stents Farmacológicos , Imunossupressores/administração & dosagem , Isquemia Miocárdica/terapia , Sirolimo/análogos & derivados , Síndrome Coronariana Aguda/terapia , Idoso , Angiografia Coronária , Doença da Artéria Coronariana/terapia , Estenose Coronária/terapia , Everolimo , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/terapia , Sirolimo/administração & dosagem , Resultado do Tratamento
10.
JACC Cardiovasc Interv ; 4(4): 432-41, 2011 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-21511223

RESUMO

OBJECTIVES: This study assessed the ability of the SYNTAX score (SXscore) to stratify risk in patients treated with percutaneous coronary intervention (PCI) using zotarolimus-eluting or everolimus-eluting stents. BACKGROUND: The SXscore can identify patients treated with PCI who are at highest risk of adverse events. METHODS: The SXscore was calculated prospectively in 2,033 of the 2,292 patients enrolled in the RESOLUTE All Comers study (RESOLUTE III All Comers Trial: A Randomized Comparison of a Zotarolimus-Eluting Stent With an Everolimus-Eluting Stent for Percutaneous Coronary Intervention). Clinical outcomes in terms of a patient-oriented composite endpoint (POCE) of all-cause death, myocardial infarction (MI), and repeat revascularization; the individual components of POCE; target lesion failure (TLF) (a composite of cardiac death, target-vessel MI, and clinically driven target lesion revascularization); and stent thrombosis were subsequently stratified according to SXscore tertiles: SXscore(LOW) ≤ 9 (n = 698), 9 17 (n = 659). RESULTS: At 12-month follow-up, rates of POCE, MI, repeat revascularization, TLF, and the composite of death/MI were all significantly higher in patients in the highest SXscore tercile. Rates of stent thrombosis were all highest in the SXscore(HIGH) tertile (p > 0.05). After multivariate adjustment, the SXscore was identified as an independent predictor of POCE, MI, repeat revascularization, and TLF (p < 0.05 for all). At 12-month follow-up, the SXscore, ACEF score, and Clinical SXscore had C-statistics of 0.57, 0.78, and 0.67, respectively, for mortality and of 0.62, 0.56, 0.63, respectively, for POCE. No significant between-stent differences were observed for TLF or POCE in any of the SXscore tertiles. CONCLUSIONS: The SYNTAX score is able to stratify risk amongst an all-comers population treated with PCI with second-generation drug-eluting stents (DES); however, improvements can be made with the inclusion of clinical variables. (RESOLUTE III All Comers Trial: A Randomized Comparison of a Zotarolimus-Eluting Stent With an Everolimus-Eluting Stent for Percutaneous Coronary Intervention; NCT00617084).


Assuntos
Angioplastia Coronária com Balão/efeitos adversos , Angioplastia Coronária com Balão/instrumentação , Fármacos Cardiovasculares/administração & dosagem , Doença da Artéria Coronariana/terapia , Stents Farmacológicos , Indicadores Básicos de Saúde , Sirolimo/análogos & derivados , Idoso , Angioplastia Coronária com Balão/mortalidade , Doença da Artéria Coronariana/mortalidade , Reestenose Coronária/etiologia , Reestenose Coronária/mortalidade , Europa (Continente) , Everolimo , Feminino , Humanos , Israel , Estimativa de Kaplan-Meier , Modelos Lineares , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/etiologia , Infarto do Miocárdio/mortalidade , Valor Preditivo dos Testes , Modelos de Riscos Proporcionais , Estudos Prospectivos , Desenho de Prótese , Medição de Risco , Fatores de Risco , Sirolimo/administração & dosagem , Taxa de Sobrevida , Fatores de Tempo , Resultado do Tratamento
11.
EuroIntervention ; 6(8): 928-35, 2011 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-21330239

RESUMO

AIMS: This study investigated the differences in clinical outcomes between patients with bifurcation lesions (BL) treated with a biolimus-eluting stent (BES) with a biodegradable polymer, and a sirolimus-eluting stent (SES) with a durable polymer. METHODS AND RESULTS: The clinical outcomes were assessed in the 497 patients (BES 258, SES 239) enrolled in the multicentre, randomised LEADERS trial who underwent treatment of ≥1 BL (total=534 BL). At 12-months follow-up there was no significant difference in the primary endpoint of MACE, a composite of cardiac death, myocardial infarction and clinically indicated target vessel revascularisation (BES 12.8% vs. SES 16.3%, p=0.31). Patients treated with BES had comparable rates of cardiac death (BES 2.7% vs. SES 2.9%, p=1.00), numerically higher rates of myocardial infarction (BES 8.9% vs. SES 5.4%, p=0.17), and significantly lower rates of clinically indicated target vessel revascularisation (4.3% vs. 11.3%, p=0.004) when compared to those treated with SES. The rate of stent thrombosis at 12-months was 4.3% and 3.8% for BES and SES, respectively (p=0.82). CONCLUSIONS: In the treatment of BL the use of BES lead to superior efficacy and comparable safety compared to SES.


Assuntos
Implantes Absorvíveis , Angioplastia Coronária com Balão , Doença da Artéria Coronariana/terapia , Stents Farmacológicos , Sirolimo/análogos & derivados , Sirolimo/uso terapêutico , Implantes Absorvíveis/efeitos adversos , Síndrome Coronariana Aguda/mortalidade , Síndrome Coronariana Aguda/terapia , Idoso , Angioplastia Coronária com Balão/mortalidade , Doença da Artéria Coronariana/mortalidade , Stents Farmacológicos/efeitos adversos , Feminino , Seguimentos , Humanos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/mortalidade , Infarto do Miocárdio/terapia , Polímeros/efeitos adversos , Resultado do Tratamento
12.
Circ Cardiovasc Interv ; 4(1): 47-56, 2011 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-21205944

RESUMO

BACKGROUND: The age, creatinine, and ejection fraction (ACEF) score (age/left ventricular ejection fraction+1 if creatinine >2.0 mg/dL) has been established as an effective predictor of clinical outcomes in patients undergoing elective coronary artery bypass surgery; however, its utility in "all-comer" patients undergoing percutaneous coronary intervention is yet unexplored. METHODS AND RESULTS: The ACEF score was calculated for 1208 of the 1707 patients enrolled in the LEADERS trial. Post hoc analysis was performed by stratifying clinical outcomes at the 1-year follow-up according to ACEF score tertiles: ACEF(low) ≤1.0225, 1.0225< ACEF(mid) ≤1.277, and ACEF(high) >1.277. At 1-year follow-up, there was a significantly lower number of patients with major adverse cardiac event-free survival in the highest tertile of the ACEF score (ACEF(low)=92.1%, ACEF(mid)=89.5%, and ACEF(high)=86.1%; P=0.0218). Cardiac death was less frequent in ACEF(low) than in ACEF(mid) and ACEF(high) (0.7% vs 2.2% vs 4.5%; hazard ratio=2.22, P=0.002) patients. Rates of myocardial infarction were significantly higher in patients with a high ACEF score (6.7% for ACEF(high) vs 5.2% for ACEF(mid) and 2.5% for ACEF(low); hazard ratio=1.6, P=0.006). Clinically driven target-vessel revascularization also tended to be higher in the ACEF(high) group, but the difference among the 3 groups did not reach statistical significance. The rate of composite definite, possible, and probable stent thrombosis was also higher in the ACEF(high) group (ACEF(low)=1.2%, ACEF(mid)=3.5%, and ACEF(high)=6.2%; hazard ratio=2.04, P<0.001). CONCLUSIONS: ACEF score may be a simple way to stratify risk of events in patients treated with percutaneous coronary intervention with respect to mortality and risk of myocardial infarction.


Assuntos
Angioplastia Coronária com Balão/mortalidade , Doença da Artéria Coronariana/terapia , Creatinina/sangue , Volume Sistólico , Fatores Etários , Idoso , Angioplastia Coronária com Balão/efeitos adversos , Doença da Artéria Coronariana/sangue , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Medição de Risco
13.
Clin Res Cardiol ; 99(12): 809-15, 2010 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-20596714

RESUMO

OBJECTIVE: To compare characteristics and outcome of patients with re-stenoses after prior carotid artery stenting (CAS) treated with repeat carotid interventions (Re-CI) with CAS for de novo lesions. BACKGROUND: The treatment of re-stenosis is a major problem in vascular interventions. Patients with re-stenoses after prior CAS treated with Re-CI are not well defined. METHODS: We analyzed data from the prospective ALKK CAS Registry. RESULTS: Out of 3,817 CAS procedures 95 were intended in 93 patients (2.5%) for a restenosis after prior CAS and 3,722 CAS in 3,655 patients (97.5%) for a de novo stenosis. There was no difference in age (p = 0.302) or distribution of gender (p = 0.545) between the two groups. Patients treated for a restenosis after CAS were less likely to be treated for a symptomatic lesion (22.7 vs. 40.1%, p = 0.001). Coronary heart disease (p = 0.017), peripheral arterial disease (p < 0.001) as well as diabetes mellitus (p = 0.004) were more prevalent in the restenosis group. Lesions were less complicated in restenosis patients, with less ulcers (7.4 vs. 19.9%, p = 0.003) and less severe calcifications (7.4 vs. 23.6%, p < 0.001). The intended interventions were more often not performed in the Re-CI group (9.5 vs. 3.3%; p = 0.001). In-hospital, the stroke or death rate was 0% in the Re-CI group as compared to 3.1% in the de novo group (p = 0.115). CONCLUSIONS: Patients treated with Re-CI for repeat stenoses after prior CAS represent 2.5% of current CAS patients. Although representing a subgroup with more concomitant diseases, Re-CI seems to be associated with lower event rates as compared to CAS for de novo lesions.


Assuntos
Estenose das Carótidas/cirurgia , Stents , Idoso , Estenose das Carótidas/patologia , Doença das Coronárias/epidemiologia , Diabetes Mellitus/epidemiologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Doença Arterial Periférica/epidemiologia , Recidiva , Sistema de Registros , Estudos Retrospectivos , Acidente Vascular Cerebral/epidemiologia , Resultado do Tratamento
14.
J Am Coll Cardiol ; 56(4): 272-7, 2010 Jul 20.
Artigo em Inglês | MEDLINE | ID: mdl-20633818

RESUMO

OBJECTIVES: We aimed to assess the predictive value of the SYNTAX score (SXscore) for major adverse cardiac events in the all-comers population of the LEADERS (Limus Eluted from A Durable versus ERodable Stent coating) trial. BACKGROUND: The SXscore has been shown to be an effective predictor of clinical outcomes in patients with multivessel disease undergoing percutaneous coronary intervention. METHODS: The SXscore was prospectively collected in 1,397 of the 1,707 patients enrolled in the LEADERS trial (patients after surgical revascularization were excluded). Post hoc analysis was performed by stratifying clinical outcomes at 1-year follow-up, according to 1 of 3 SXscore tertiles. RESULTS: The 1,397 patients were divided into tertiles based on the SXscore in the following fashion: SXscore8 and 16 (SXhigh) (n=461). At 1-year follow-up, there was a significantly lower number of patients with major cardiac event-free survival in the highest tertile of SXscore (SXlow=92.2%, SXmid=91.1%, and SXhigh=84.6%; p<0.001). Death occurred in 1.5% of SXlow patients, 2.1% of SXmid patients, and 5.6% of SXhigh patients (hazard ratio [HR]: 1.97, 95% confidence interval [CI]: 1.29 to 3.01; p=0.002). The myocardial infarction rate tended to be higher in the SXhigh group. Target vessel revascularization was 11.3% in the SXhigh group compared with 6.3% and 7.8% in the SXlow and SXmid groups, respectively (HR: 1.38, 95% CI: 1.1 to 1.75; p=0.006). Composite of cardiac death, myocardial infarction, and clinically indicated target vessel revascularization was 7.8%, 8.9%, and 15.4% in the SXlow, SXmid, and SXhigh groups, respectively (HR: 1.47, 95% CI: 1.19 to 1.81; p<0.001). CONCLUSIONS: The SXscore, when applied to an all-comers patient population treated with drug-eluting stents, may allow prospective risk stratification of patients undergoing percutaneous coronary intervention. (LEADERS Trial Limus Eluted From A Durable Versus ERodable Stent Coating; NCT00389220).


Assuntos
Stents Farmacológicos , Infarto do Miocárdio/diagnóstico por imagem , Infarto do Miocárdio/tratamento farmacológico , Vigilância da População/métodos , Índice de Gravidade de Doença , Idoso , Stents Farmacológicos/efeitos adversos , Stents Farmacológicos/normas , Feminino , Seguimentos , Humanos , Masculino , Estudos Prospectivos , Radiografia , Valores de Referência , Medição de Risco
15.
N Engl J Med ; 363(2): 136-46, 2010 Jul 08.
Artigo em Inglês | MEDLINE | ID: mdl-20554978

RESUMO

BACKGROUND: New-generation coronary stents that release zotarolimus or everolimus have been shown to reduce the risk of restenosis. However, it is unclear whether there are differences in efficacy and safety between the two types of stents on the basis of prospectively adjudicated end points endorsed by the Food and Drug Administration. METHODS: In this multicenter, noninferiority trial with minimal exclusion criteria, we randomly assigned 2292 patients to undergo treatment with coronary stents releasing either zotarolimus or everolimus. Twenty percent of patients were randomly selected for repeat angiography at 13 months. The primary end point was target-lesion failure, defined as a composite of death from cardiac causes, any myocardial infarction (not clearly attributable to a nontarget vessel), or clinically indicated target-lesion revascularization within 12 months. The secondary angiographic end point was the extent of in-stent stenosis at 13 months. RESULTS: At least one off-label criterion for stent placement was present in 66% of patients. The zotarolimus-eluting stent was noninferior to the everolimus-eluting stent with respect to the primary end point, which occurred in 8.2% and 8.3% of patients, respectively (P<0.001 for noninferiority). There were no significant between-group differences in the rate of death from cardiac causes, any myocardial infarction, or revascularization. The rate of stent thrombosis was 2.3% in the zotarolimus-stent group and 1.5% in the everolimus-stent group (P=0.17). The zotarolimus-eluting stent was also noninferior regarding the degree (+/-SD) of in-stent stenosis (21.65+/-14.42% for zotarolimus vs. 19.76+/-14.64% for everolimus, P=0.04 for noninferiority). In-stent late lumen loss was 0.27+/-0.43 mm in the zotarolimus-stent group versus 0.19+/-0.40 mm in the everolimus-stent group (P=0.08). There were no significant between-group differences in the rate of adverse events. CONCLUSIONS: At 13 months, the new-generation zotarolimus-eluting stent was found to be noninferior to the everolimus-eluting stent in a population of patients who had minimal exclusion criteria. (ClinicalTrials.gov number, NCT00617084.)


Assuntos
Doença das Coronárias/terapia , Stents Farmacológicos , Infarto do Miocárdio/terapia , Sirolimo/análogos & derivados , Idoso , Angiografia Coronária , Doença das Coronárias/mortalidade , Reestenose Coronária , Stents Farmacológicos/efeitos adversos , Everolimo , Feminino , Humanos , Análise de Intenção de Tratamento , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/epidemiologia , Desenho de Prótese , Retratamento , Sirolimo/administração & dosagem , Falha de Tratamento
16.
EuroIntervention ; 6(2): 233-9, 2010 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-20562074

RESUMO

AIMS: This study reports the 12-month clinical outcomes of the LEADERS clinical trial which compared a biolimus eluting stent with a biodegradable polymer (BES) to a sirolimus eluting stent with a durable polymer (SES). METHODS AND RESULTS: The multicentre LEADERS trial employed an all-comers approach to recruit 1,707 patients who were randomised to treatment with either BES (n=857) or SES (n=850) in a non-inferiority design. The primary clinical endpoint of this study was a composite of cardiac death, myocardial infarction and clinical-indicated target vessel revascularisation. Follow-up was obtained in 97.6% of patients. At 12 months, BES remained non-inferior compared to SES for the primary endpoint (BES 10.6% vs. SES 12.0%, HR:0.88, 95% CI:0.66-1.17, p=0.37). Rates of cardiac death (2.1% vs. 2.7%, HR:0.77, 95% CI:0.42-1.44, p=0.42), MI (5.8% vs. 4.6%, HR:1.27, 95% CI:0.84-1.94, p=0.26) and clinically-indicated target vessel revascularisation (5.8% vs. 7.1%, HR:0.82, 95%CI:0.56-1.19, p=0.29) were similar for BES and SES. Similarly, there was no difference in the incidence of definite stent thrombosis at 12 months. CONCLUSIONS: These findings support the safety and efficacy of the BES stent with a biodegradable polymer at 12-month clinical follow-up, and suggest it is a suitable alternative to the SES stent with a durable polymer.


Assuntos
Stents Farmacológicos , Sirolimo/análogos & derivados , Sirolimo/administração & dosagem , Implantes Absorvíveis , Feminino , Seguimentos , Humanos , Ácido Láctico , Masculino , Pessoa de Meia-Idade , Poliésteres , Polímeros , Estudos Prospectivos , Fatores de Tempo , Resultado do Tratamento
17.
Am J Cardiol ; 105(4): 475-9, 2010 Feb 15.
Artigo em Inglês | MEDLINE | ID: mdl-20152241

RESUMO

The aim of this analysis was to assess the effect of body mass index (BMI) on 1-year outcomes in patients enrolled in a contemporary percutaneous coronary intervention trial comparing a sirolimus-eluting stent with a durable polymer to a biolimus-eluting stent with a biodegradable polymer. A total of 1,707 patients who underwent percutaneous coronary intervention were randomized to treatment with either biolimus-eluting stents (n = 857) or sirolimus-eluting stents (n = 850). Patients were assigned to 1 of 3 groups according to BMI: normal (<25 kg/m(2)), overweight (25 to 30 kg/m(2)), or obese (>30 kg/m(2)). At 1 year, the incidence of the composite of cardiac death, myocardial infarction, and clinically justified target vessel revascularization was assessed. In addition, rates of clinically justified target lesion revascularization and stent thrombosis were assessed. Cox proportional-hazards analysis, adjusted for clinical differences, was used to develop models for 1-year mortality. Forty-five percent of the patients (n = 770) were overweight, 26% (n = 434) were obese, and 29% (n = 497) had normal BMIs. At 1-year follow-up, the cumulative rate of cardiac death, myocardial infarction, and clinically justified target vessel revascularization was significantly higher in the obese group (8.7% in normal-weight, 11.3% in overweight, and 14.5% in obese patients, p = 0.01). BMI (hazard ratio 1.47, 95% confidence interval 1.02 to 2.14, p = 0.04) was an independent predictor of stent thrombosis. Stent type had no impact on the composite of cardiac death, myocardial infarction, and clinically justified target vessel revascularization at 1 year in the 3 BMI groups (hazard ratio 1.08, 95% confidence interval 0.63 to 1.83, p = 0.73). In conclusion, BMI was an independent predictor of major adverse cardiac events at 1-year clinical follow-up. The higher incidence of stent thrombosis in the obese group may suggest the need for a weight-adjusted dose of clopidogrel.


Assuntos
Angioplastia Coronária com Balão , Índice de Massa Corporal , Stents Farmacológicos , Imunossupressores/administração & dosagem , Infarto do Miocárdio/terapia , Sirolimo/análogos & derivados , Sirolimo/administração & dosagem , Idoso , Angioplastia Coronária com Balão/mortalidade , Intervalos de Confiança , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/mortalidade , Países Baixos , Obesidade/complicações , Razão de Chances , Sobrepeso/complicações , Valor Preditivo dos Testes , Modelos de Riscos Proporcionais , Fatores de Risco , Análise de Sobrevida , Resultado do Tratamento
18.
EuroIntervention ; 5(3): 310-7, 2009 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-19736154

RESUMO

AIMS: Lesion length remains a predictor of target lesion revascularisation and results of long lesion stenting remain poor. Sirolimus-eluting stents have been shown to perform better than paclitaxel eluting stents in long lesions. In this substudy of the LEADERS trial, we compared the performance of biolimus biodegradable polymer (BES) and sirolimus permanent polymer stents (SES) in long lesions. METHODS AND RESULTS: A total of 1,707 'all-comer' patients were randomly allocated to treatment with BES and SES. A stratified analysis of angiographic and clinical outcomes at nine months and one year, respectively was performed for vessels with lesion length <20 mm versus >20 mm (as measured by quantitative angiography).Of 1,707 patients, 592 BES patients with 831 lesions and 619 SES patients with 876 lesions had only short lesions treated. One hundred and fifty-three BES patients with 166 lesions and 151 SES patients with 162 lesions had long lesions. There were no significant differences in baseline clinical characteristics, except for higher number of patients with long lesions presenting with acute myocardial infarction in both stent groups. Long lesions tended to have lower MLD and greater percent diameter stenosis at baseline than short lesions. Late loss was greater for long lesions than short lesions. There was no statistically significant difference in late loss between BES and SES stents (0.32+/-0.69 vs 0.24+/-0.57, p=0.59). Binary in-segment restenosis was present in 23.2% versus 13.1% of long lesions treated with BES and SES, respectively (p=0.042). In patients with long lesions, the overall MACE rate was similar for BES and SES (17% vs 14.6%; p=0.62). There was a trend towards higher overall TLR rate with BES (12.4 % vs 6.0%; HR=2.06; p=0.07) and clinically driven TLR (10.5% vs 5.3%: HR 1.94; p=0.13). Rates of definite stent thrombosis were 3.3% in the long lesion group and 1.3-1.7 % in the short lesion group. CONCLUSIONS: BES and SES appear similar with respect to MACE in long lesions in this "all-comer" patient population. However, long lesions tended to have a higher rate of binary in-segment restenosis and TLR following BES than SES treatment.


Assuntos
Implantes Absorvíveis , Angioplastia Coronária com Balão/instrumentação , Fármacos Cardiovasculares/administração & dosagem , Estenose Coronária/terapia , Stents Farmacológicos , Infarto do Miocárdio/terapia , Polímeros , Sirolimo/análogos & derivados , Idoso , Angioplastia Coronária com Balão/efeitos adversos , Angiografia Coronária , Reestenose Coronária/etiologia , Estenose Coronária/complicações , Estenose Coronária/diagnóstico por imagem , Europa (Continente) , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/diagnóstico por imagem , Infarto do Miocárdio/etiologia , Modelos de Riscos Proporcionais , Desenho de Prótese , Medição de Risco , Sirolimo/administração & dosagem , Trombose/etiologia , Fatores de Tempo , Resultado do Tratamento
19.
JACC Cardiovasc Interv ; 2(9): 861-70, 2009 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-19778775

RESUMO

OBJECTIVES: We assessed the impact of vessel size on outcomes of stenting with biolimus-eluting degradable polymer stent (BES) and sirolimus-eluting permanent polymer stent (SES) within a randomized multicenter trial (LEADERS). BACKGROUND: Stenting of small vessels might be associated with higher rates of adverse events. METHODS: "All-comer" patients (n = 1,707) were randomized to BES and SES. Post-hoc-stratified analysis of angiographic and clinical outcomes at 9 months and 1 year, respectively, was performed for vessels with reference diameter 2.75 mm. RESULTS: Of 1,707 patients, 429 patients in the BES group with 576 lesions and 434 patients in the SES group with 557 lesions had only small vessels treated (50.6% of the patient cohort). In patients with small vessels there was no significant difference in overall major adverse cardiac events (MACE) rate (12.1% vs. 11.8%; p = 0.89) or target lesion revascularization (TLR) rate (9.6% vs. 7.4%; p = 0.26) between BES and SES. The MACE and TLR rates in the small-vessel patient population were higher than in the large-vessel population. The TLR rate was 9.6% versus 2.6%, and MACE rate was 12.1% versus 7.1% for small versus large vessels in the BES arm (TLR: hazard ratio [HR] = 3.724, p = 0.0013; MACE: HR = 1.720, p = 0.0412). In the SES arm, TLR was 7.4% versus 5.1%, and MACE was 11.8% versus 10.3% in small versus large vessels (TLR: HR = 1.435, p = 0.2594; MACE: HR = 1.149, p = 0.5546). CONCLUSIONS: Prevalence of small vessel disease is high in an "all-comer" population with higher TLR and MACE rates. The BES and SES seem equivalent in treatment outcomes of small vessels in this "all-comer" patient population.


Assuntos
Implantes Absorvíveis , Angioplastia Coronária com Balão/instrumentação , Fármacos Cardiovasculares/administração & dosagem , Angiografia Coronária , Estenose Coronária/terapia , Stents Farmacológicos , Polímeros , Sirolimo/análogos & derivados , Idoso , Angioplastia Coronária com Balão/efeitos adversos , Reestenose Coronária/diagnóstico por imagem , Reestenose Coronária/etiologia , Estenose Coronária/diagnóstico por imagem , Europa (Continente) , Feminino , Humanos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Modelos de Riscos Proporcionais , Desenho de Prótese , Medição de Risco , Índice de Gravidade de Doença , Sirolimo/administração & dosagem , Trombose/diagnóstico por imagem , Trombose/etiologia , Fatores de Tempo , Resultado do Tratamento
20.
Am J Cardiol ; 104(5): 725-31, 2009 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-19699352

RESUMO

Data on the safety of carotid artery stenting (CAS) in a large number of unselected patients with contralateral occlusion and significant ipsilateral stenosis are less known. Accordingly, we evaluated 3,137 patients undergoing CAS who were enrolled in a German Registry from 2000 to 2008 and compared the clinical features and in-hospital outcomes of those with and without contralateral carotid occlusion. Contralateral carotid occlusion was present in 191 patients (6.1%) undergoing CAS. Despite the similar age of the patients with and without contralateral carotid occlusion, those with contralateral occlusion had a greater prevalence of co-morbidities, complex carotid stenosis, and greater number of focal neurologic lesions on the contralateral side. The incidence of in-hospital events, including death (1.0% vs 0.5%), ipsilateral major stroke (1.1% vs 1.1%), death or major ipsilateral stroke (1.6% vs 1.4%), ipsilateral transient ischemic attack (2.7% vs 2.5%), myocardial infarction (0.0% vs 0.1%), and reintervention (0.5% vs 1.1%), was low and was not significantly different between those with and without contralateral occlusion (p >0.05 for all comparisons). Among patients with carotid occlusion, major ipsilateral stroke (2.2%), death (2.2%), and a combination of these 2 events (3.3%) were observed exclusively in symptomatic patients with no event in asymptomatic patients. In conclusion, our data from a large number of patients undergoing CAS in a recent contemporary community-based practice attests to the low risk of periprocedural events among patients with contralateral carotid occlusion supporting CAS as an attractive option for the treatment of these patients.


Assuntos
Angioplastia com Balão , Estenose das Carótidas/terapia , Stents , Estenose das Carótidas/epidemiologia , Estenose das Carótidas/mortalidade , Estenose das Carótidas/patologia , Comorbidade , Doença da Artéria Coronariana/epidemiologia , Alemanha , Mortalidade Hospitalar , Humanos , Ataque Isquêmico Transitório/epidemiologia , Doenças Vasculares Periféricas/epidemiologia , Sistema de Registros , Acidente Vascular Cerebral/epidemiologia , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...