MAGMA ; 36(5): 737-747, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-36723689

RESUMO

OBJECTIVE: We introduce a non-invasive MR-Acoustic Radiation Force Imaging (ARFI)-based elastography method that provides both the local shear modulus and temperature maps for the monitoring of High Intensity Focused Ultrasound (HIFU) therapy. MATERIALS AND METHODS: To take tissue anisotropy into account, the local shear modulus µ is determined in selected radial directions around the focal spot by fitting the phase profiles to a linear viscoelastic model, including tissue-specific mechanical relaxation time τ. MR-ARFI was evaluated on a calibrated phantom, then applied to the monitoring of HIFU in a gel phantom, ex vivo and in vivo porcine muscle tissue, in parallel with MR-thermometry. RESULTS: As expected, the shear modulus polar maps reflected the isotropy of phantoms and the anisotropy of muscle. In the HIFU monitoring experiments, both the shear modulus polar map and the thermometry map were updated with every pair of MR-ARFI phase images acquired with opposite MR-ARFI-encoding. The shear modulus was found to decrease (phantom and ex vivo) or increase (in vivo) during heating, before remaining steady during the cooling phase. The mechanical relaxation time, estimated pre- and post-HIFU, was found to vary in muscle tissue. DISCUSSION: MR-ARFI allowed for monitoring of viscoelasticity changes around the HIFU focal spot even in anisotropic muscle tissue.


Assuntos
Ablação por Ultrassom Focalizado de Alta Intensidade , Imageamento por Ressonância Magnética , Animais , Suínos , Anisotropia , Imageamento por Ressonância Magnética/métodos , Ablação por Ultrassom Focalizado de Alta Intensidade/métodos , Espectroscopia de Ressonância Magnética , Acústica
2.
Phys Med Biol ; 68(3)2023 Jan 24.
Artigo em Inglês | MEDLINE | ID: mdl-36595333

RESUMO

Objective.The aim of the paper is to propose an all-in-one method based on magnetic resonance-supersonic shear wave imaging (MR-SSI) and proton resonance frequency shift (PRFS) to monitor high intensity focused ultrasound (HIFU) thermal ablations.Approach.Mechanical properties have been shown to be related to tissue damage induced by thermal ablations. Monitoring elasticity in addition to temperature changes may help in ensuring the efficacy and the accuracy of HIFU therapies. For this purpose, an MR-SSI method has been developed where the ultrasonic transducer is used for both mechanical wave generation and thermal ablation. Transient quasi-planar shear waves are generated using the acoustic radiation force, and their propagation is monitored in motion-sensitized phase MR images. Using a single-shot gradient-echo echo-planar-imaging sequence, MR images can be acquired at a sufficiently high temporal resolution to provide an update of PRFS thermometry and MR-SSI elastography maps in real time.Main results.The proposed method was first validated on a calibrated elasticity phantom, in which both the possibility to detect inclusions with different stiffness and repeatability were demonstrated. The standard deviation between the 8 performed measurements was 2% on the background of the phantom and 11%, at most, on the inclusions. A second experiment consisted in performing a HIFU heating in a gelatin phantom. The temperature increase was estimated to be 9 °C and the shear modulus was found to decrease from 2.9 to 1.8 kPa, reflecting the gel softening around the HIFU focus, whereas it remained steady in non-heated areas.Significance.The proposed MR-SSI technique allows monitoring HIFU ablations using thermometry and elastography simultaneously, without the need for an additional external mechanical exciter such as those used in MR elastography.


Assuntos
Técnicas de Imagem por Elasticidade , Tratamento por Ondas de Choque Extracorpóreas , Ablação por Ultrassom Focalizado de Alta Intensidade , Termometria , Técnicas de Imagem por Elasticidade/métodos , Termometria/métodos , Elasticidade , Ultrassom , Imageamento por Ressonância Magnética/métodos , Ablação por Ultrassom Focalizado de Alta Intensidade/métodos