Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 33
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Occup Health ; 2024 Jul 11.
Artigo em Inglês | MEDLINE | ID: mdl-38990604

RESUMO

OBJECTIVES: Concerning occupational exposure to ortho-phthalaldehyde (OPA) used in washing endoscope probes, the American Conference of Governmental Industrial Hygienists recommends a threshold limit value-ceiling (TLV-C) of 0.1 ppb. To adhere to this extremely low exposure limit, this case study aimed to reduce OPA exposure concentrations of workers during immersion washing of an endoscope probe body. This was achieved by attaching a new duct and hood to the existing ceiling exhaust system. METHODS: The type of hood was determined by calculating and comparing the capture velocity obtained by assuming the exterior or enclosing hood. Additionally, the effect on improving the working environment was tested before and after the installation of the hood by measuring the OPA vapor concentration. RESULTS: The calculated capture velocities of the exterior and enclosing hoods were 0.05 m/s and 0.19 m/s, respectively. Considering the operability, the exterior hood was more appropriate; however, the calculated capture velocity indicated potential inadequacy in meeting the TLV-C requirement, leading to the adoption of the enclosing hood. The OPA vapor concentration in ceiling value measurement taken after enclosing hood implementation was reduced to 0.2 ppb, that is 1/10 of the original concentration. CONCLUSIONS: Although the environmental concentration after the improvement still exceeded the TLV-C of 0.1 ppb, this study's findings indicate that even substances with extremely low occupational exposure limits can be managed with appropriate local exhaust ventilation.

2.
Part Fibre Toxicol ; 19(1): 8, 2022 01 21.
Artigo em Inglês | MEDLINE | ID: mdl-35062982

RESUMO

BACKGROUND: Some organic chemicals are known to cause allergic disorders such as bronchial asthma and hypersensitivity pneumonitis, and it has been considered that they do not cause irreversible pulmonary fibrosis. It has recently been reported, however, that cross-linked acrylic acid-based polymer, an organic chemical, might cause serious interstitial lung diseases, including pulmonary fibrosis. We investigated whether or not intratracheal instillation exposure to cross-linked polyacrylic acid (CL-PAA) can cause lung disorder in rats. METHODS: Male F344 rats were intratracheally instilled with dispersed CL-PAA at low (0.2 mg/rat) and high (1.0 mg/rat) doses, and were sacrificed at 3 days, 1 week, 1 month, 3 months and 6 months after exposure to examine inflammatory and fibrotic responses and related gene expressions in the lungs. Rat lungs exposed to crystalline silica, asbestos (chrysotile), and NiO and CeO2 nanoparticles were used as comparators. RESULTS: Persistent increases in total cell count, neutrophil count and neutrophil percentage, and in the concentration of the cytokine-induced neutrophil chemoattractant (CINC)-1, CINC-2 and C-X-C motif chemokine 5 (CXCL5), which correlated with lung tissue gene expression, were observed in bronchoalveolar lavage fluid (BALF) from 3 days until at least 1 month following CL-PAA intratracheal instillation. Persistent increases in heme oxygenase-1 (HO-1) in the lung tissue were also observed from 3 days to 6 months after exposure. Histopathological findings of the lungs demonstrated that extensive inflammation at 3 days was greater than that in exposure to silica, NiO nanoparticles and CeO2 nanoparticles, and equal to or greater than that in asbestos (chrysotile) exposure, and the inflammation continued until 1 month. Fibrotic changes also progressed after 1 month postexposure. CONCLUSION: Our results suggested that CL-PAA potentially causes strong neutrophil inflammation in the rat and human lung.


Assuntos
Resinas Acrílicas , Pulmão , Animais , Líquido da Lavagem Broncoalveolar , Masculino , Ratos , Ratos Endogâmicos F344
3.
Ind Health ; 59(4): 239-248, 2021 Sep 09.
Artigo em Inglês | MEDLINE | ID: mdl-34261823

RESUMO

Previously, we reported that prenatal exposure to 1-bromopropane (1-BP) causes the accumulation of bromide (Br-) in the brain of rat pups. Here, we aimed to investigate the effects of Br- accumulation in rat pups prenatally exposed to 1-BP vapor. Dam rats were exposed to 1-BP (400 or 700 ppm; 1-BP group) by inhalation, or to NaBr (20 mM; Br- group) in drinking water during gestation days 1-20. We also analyzed pentylenetetrazole (PTZ, 60 mg/kg, ip)-induced behavioral changes in pups prenatally exposed to 1-BP or Br- on postnatal day (PND) 14. PTZ-induced epileptic convulsions were inhibited in both 1-BP (700 ppm) and Br- groups. The inhibition of neuronal excitability induced by Br- was evaluated electrophysiologically using the hippocampal slices obtained from PND14-16 pups. PTZ (2 mM) failed to induce epileptiform discharge in the presence of 1.2 mM Br- in the slices obtained from the control group. However, it induced epileptiform discharge following the removal of Br-, by perfusing artificial cerebrospinal fluid into the slices obtained from the Br- group. Our results indicate that Br- accumulates in the brain of neonatal rat pups prenatally exposed to 1-BP vapor suppressed neuronal excitability.


Assuntos
Brometos , Efeitos Tardios da Exposição Pré-Natal , Animais , Encéfalo , Feminino , Hidrocarbonetos Bromados , Gravidez , Efeitos Tardios da Exposição Pré-Natal/induzido quimicamente , Ratos , Ratos Wistar
4.
J Occup Health ; 62(1): e12135, 2020 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-32715571

RESUMO

OBJECTIVES: Although 1-Bromopropane (1-BP) exposure has been reported to cause neurotoxicity in adult humans and animals, its effects on the development of the central nervous system remain unclear. Recently, we reported delayed developmental neurotoxicity (DNT) upon 1-BP exposure in rats. Here we aimed to study the effect of prenatal 1-BP exposure on the hippocampal excitability in the juvenile offspring. METHODS: Pregnant Wistar rats were exposed to vaporized 1-BP for 20 days (6 h/d) with concentrations of 0 (control), 400, or 700 ppm. Hippocampal slices were prepared from male offspring during postnatal days (PNDs) 13, 14, and 15. Field excitatory postsynaptic potential (fEPSP) and population spike (PS) were recorded simultaneously from the CA1 region. RESULTS: In the exposed groups, the stimulation/response relationships of fEPSP slope and PS amplitude were enhanced more than in the control group at PND 14. Analysis of fEPSP-spike coupling demonstrated increased values of Top and Eslope50 in the exposed groups. Real-time PCR analysis showed a significant increase in the mRNA levels of the adult type Nav 1.1 Na+ channel subunit and the GluR1 glutamate receptor subunit in the hippocampus of the 700 ppm group at PND 14. CONCLUSIONS: Our results provide evidence that prenatal exposure to 1-BP accelerates developmental enhancement of hippocampal excitability in the pups before eye-opening. The current study suggests that our evaluation method of DNT is applicable to the industrial chemical 1-BP.


Assuntos
Região CA1 Hipocampal/efeitos dos fármacos , Excitabilidade Cortical/efeitos dos fármacos , Exposição por Inalação , Lactação , Efeitos Tardios da Exposição Pré-Natal/induzido quimicamente , Animais , Feminino , Hidrocarbonetos Bromados/efeitos adversos , Gravidez , Ratos , Ratos Wistar
5.
J Occup Health ; 62(1): e12139, 2020 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-32713059

RESUMO

OBJECTIVES: The present study aimed to develop a method for measuring the ceiling level of ortho-phthalaldehyde (OPA) exposure and evaluate the ceiling levels of OPA exposure among health care workers who handle disinfectant solutions containing OPA for the disinfection of endoscopes. METHODS: The study consisted of a preliminary survey and main survey. In the preliminary survey, processes involving high-concentration exposure to OPA were identified by video-exposure monitoring (VEM). In the main survey, the ceiling levels of OPA exposure for high-concentration exposure processes identified from the results of the preliminary survey were determined using a measuring method combining sampling using a 2,4-dinitrophenylhydrazine-silica cartridge and analysis by high-performance liquid chromatography tandem mass spectrometry. RESULTS: In the preliminary survey, seven processes involving high-concentration exposure to OPA were identified by VEM. The duration of each process was short, lasting from 20 seconds to a few minutes. In the main survey, the OPA concentrations for the identified high-concentration exposure processes ranged from 1.18 to 4.49 ppb, which markedly exceeded the threshold limit value ceiling (TLV-C) of 0.1 ppb recommended by the American Conference of Governmental Industrial Hygienists. CONCLUSIONS: The method for measuring the ceiling level of OPA exposure was established using VEM and the highly sensitive method of chemical analysis; and we successfully evaluated the ceiling levels of OPA exposure among health care workers engaged in endoscope disinfection. This approach can also be applied to other chemical substances with recommended TLV-Cs, and important information for reducing exposure can thus be obtained.


Assuntos
Desinfetantes/análise , Endoscópios , Monitoramento Ambiental/métodos , Pessoal de Saúde , Exposição Ocupacional/análise , o-Ftalaldeído/análise , Desinfetantes/efeitos adversos , Contaminação de Equipamentos/prevenção & controle , Humanos , Exposição por Inalação , Inquéritos e Questionários , Gravação em Vídeo , o-Ftalaldeído/efeitos adversos
6.
J Occup Health ; 62(1): e12105, 2020 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-31883172

RESUMO

OBJECTIVES: The purpose of this research was to develop and validate an analytical method for rapid determination of the exposure of workers to ortho-phthalaldehyde (OPA) at the ceiling threshold concentration. METHODS: A 2,4-dinitrophenylhydrazine (DNPH)-silica cartridge was chosen as a sampler. OPA collected by the DNPH-silica cartridge was subsequently extracted with 5 mL of acetonitrile. A 50-µL aliquot of phosphoric acid/acetonitrile solution (2%, v/v) was added to 950 µL of the extraction solution and allowed to stand for 30 minutes at room temperature. This solution was then analyzed by high-performance liquid chromatography tandem mass spectrometry. The basic characteristics of the proposed method, such as recovery, repeatability, limit of quantification, and storage stability of the samples, were examined. RESULTS: The overall recoveries of OPA from OPA-spiked DNPH-silica cartridges were 93.6%-100.1% with relative standard deviations, representing the repeatability, of 1.5%-10.8%. The limit of quantification was 0.165 ng/sample. The recovery of OPA from DNPH-silica cartridges after 5 days of storage in a refrigerator exceeded 95%. CONCLUSIONS: The proposed method enabled the determination of the OPA concentration corresponding to the Threshold Limit Value-Ceiling of 0.1 ppb recommended by the American Conference of Governmental Industrial Hygienists, with a minimum sampling time of 18 seconds (corresponding to a sampling volume of 300 mL at 25°C and 1 atm). Thus, this method will be useful for estimating worker exposures to OPA.


Assuntos
Poluentes Ocupacionais do Ar/análise , Monitoramento Ambiental/métodos , Exposição Ocupacional/análise , Níveis Máximos Permitidos , o-Ftalaldeído/análise , Cromatografia Líquida de Alta Pressão , Humanos , Espectrometria de Massas , Estrutura Molecular , Fenil-Hidrazinas , Dióxido de Silício
7.
J Occup Health ; 60(1): 74-79, 2018 Jan 25.
Artigo em Inglês | MEDLINE | ID: mdl-29093363

RESUMO

OBJECTIVES: Neurotoxicity of 1-bromopropane (1-BP) has been reported in occupational exposure, but whether the chemical exerts developmental neurotoxicity is unknown. We studied the effects of prenatal 1-BP exposure on neuronal excitability in rat offspring. METHODS: We exposed dams to 1-BP (700 ppm, 6 h a day for 20 days) and examined hippocampal slices obtained from the male offspring at 2, 5, 8, and 13 weeks of age. We measured the stimulation/response (S/R) relationship and paired-pulse ratios (PPRs) of the population spike (PS) at the interpulse intervals (IPIs) of 5 and 10 ms in the CA1 subfield. RESULTS: Prenatal 1-BP exposure enhanced S/R relationships of PS at 2 weeks of age; however, the enhancement diminished at 5 weeks of age until it reached control levels. Prenatal 1-BP exposure decreased PPRs of PS at 2 weeks of age. After sexual maturation, however, the PPRs of PS increased at 5-ms IPI in rats aged 8 and 13 weeks. CONCLUSIONS: Our findings indicate that prenatal 1-BP exposure in dams can cause delayed adverse effects on excitability of pyramidal cells in the hippocampal CA1 subfield of offspring.


Assuntos
Região CA1 Hipocampal/efeitos dos fármacos , Excitabilidade Cortical/efeitos dos fármacos , Síndromes Neurotóxicas/fisiopatologia , Efeitos Tardios da Exposição Pré-Natal/fisiopatologia , Animais , Feminino , Hidrocarbonetos Bromados/toxicidade , Masculino , Síndromes Neurotóxicas/etiologia , Gravidez , Efeitos Tardios da Exposição Pré-Natal/induzido quimicamente , Ratos , Ratos Wistar
8.
J UOEH ; 38(4): 305-309, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27980313

RESUMO

Decomposition characteristics of toluene vapor by titanium dioxide photocatalyst and zeolite that are prepared by thermal spraying on an aluminum fiber filter (photocatalyst filter) were investigated. Toluene vapor was injected into a small chamber made of stainless steel, and an air cleaner equipped with the photocatalyst filter was operated. The vapor concentration in the chamber decreased exponentially. The decreasing rate of toluene vapor in the chamber depended on the initial toluene concentration, and the higher the initial vapor concentration was, the lower the decreasing rate was obtained. The decreasing rate was constant during each decomposition experiment, although the concentration decreased with time. To investigate the effect of zeolite on the reduction of the vapor concentration, we compared the decreasing rates of toluene vapor by photocatalyst filters with and without zeolite.The decreasing rate of toluene concentration using the filter without zeolite was larger than that with zeolite. The reason for this would be that photocatalyst decomposed toluene not only in air but also adsorbed in zeolite.


Assuntos
Alumínio/química , Processos Fotoquímicos , Titânio/química , Tolueno/química , Zeolitas/química , Volatilização
10.
J Occup Health ; 58(3): 241-6, 2016 Jun 16.
Artigo em Inglês | MEDLINE | ID: mdl-27108641

RESUMO

OBJECTIVE: Inhaled 1-bromopropane decomposes easily and releases bromine ion. However, the kinetics and transfer of bromine ion into the next generation have not been clarified. In this work, the kinetics of bromine ion transfer to the next generation was investigated by using cross-fostering analysis and a one-compartment model. METHODS: Pregnant Wistar rats were exposed to 700 ppm of 1-bromopropane vapor for 6 h per day during gestation days (GDs) 1-20. After birth, cross-fostering was performed between mother exposure groups and mother control groups, and the pups were subdivided into the following four groups: exposure group, postnatal exposure group, gestation exposure group, and control group. Bromine ion concentrations in the brain were measured temporally. RESULTS: Bromine ion concentrations in mother rats were lower than those in virgin rats, and the concentrations in fetuses were higher than those in mothers on GD20. In the postnatal period, the concentrations in the gestation exposure group decreased with time, and the biological half-life was 3.1 days. Conversely, bromine ion concentration in the postnatal exposure group increased until postnatal day 4 and then decreased. This tendency was also observed in the exposure group. A one-compartment model was applied to analyze the behavior of bromine ion concentration in the brain. By taking into account the increase of body weight and change in the bromine ion uptake rate in pups, the bromine ion concentrations in the brains of the rats could be estimated with acceptable precision.


Assuntos
Exposição por Inalação/análise , Íons/análise , Troca Materno-Fetal , Animais , Peso Corporal , Feminino , Hidrocarbonetos Bromados/farmacocinética , Gravidez , Ratos , Ratos Wistar , Volatilização
11.
J UOEH ; 38(1): 9-16, 2016 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-26972940

RESUMO

Equilibrated vapor concentrations at 25°C of the tetrachloroethylene-chlorobenzene system were obtained in the presence of air to establish a method for estimating vapor concentrations in work environments where multicomponent organic solvents are used. The experimental data were correlated by introducing activity coefficients calculated by the UNIFAC (Universal Quasichemical Functional Group Activity Coefficient) model. There were four interaction parameters between groups in this solution system, and three had already been determined.However, the fourth parameter--the interaction parameter between ACCl and Cl-(C=C) groups--remains unknown. Therefore, this parameter was determined by a nonlinear least-squares method to obtain the best fit for the experimental data. The calculated values were found to be in good agreement with the experimental values.


Assuntos
Poluentes Ocupacionais do Ar/análise , Clorobenzenos/análise , Exposição Ocupacional/análise , Tetracloroetileno/análise , Modelos Teóricos , Solventes , Temperatura , Volatilização
12.
Ind Health ; 54(1): 42-9, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-26320726

RESUMO

Many volatile organic compounds (VOCs) used in work places are neurotoxic. However, it has been difficult to study the cellular mechanisms induced by a direct exposure to neurons because of their high volatility. The objective of this study was to establish a stable system for exposing brain slices to VOCs. With a conventional recording system for brain slices, it is not possible to keep a constant bath concentration of relatively highly volatile solvents, e.g. 1-bromopropane (1-BP). Here we report a new exposure system for VOCs that we developed in which a high concentration of oxygen is dissolved to a perfused medium applying a gas-liquid equilibrium, and in which the tubing is made of Teflon, non adsorptive material. Using our system, the bath concentration of the perfused 1-BP remained stable for at least 2 h in the slice chamber. Both 6.4 and 2.2 mM of 1-BP did not change the paired-pulse response, but fully suppressed long-term potentiation in the dentate gyrus (DG) of hippocampal slices obtained from rats, suggesting that 1-BP decreases synaptic plasticity in the DG at the concentrations tested. Our new system can be applicable for investigating the underlying mechanisms of the neurotoxicity of VOCs at the cellular level.


Assuntos
Giro Denteado/efeitos dos fármacos , Sinapses/efeitos dos fármacos , Compostos Orgânicos Voláteis/toxicidade , Animais , Cultura em Câmaras de Difusão , Hidrocarbonetos Bromados/análise , Hidrocarbonetos Bromados/toxicidade , Masculino , Plasticidade Neuronal/efeitos dos fármacos , Transição de Fase , Ratos , Técnicas de Cultura de Tecidos , Compostos Orgânicos Voláteis/análise
13.
J UOEH ; 37(4): 255-61, 2015 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-26667193

RESUMO

1-Bromopropane (1-BP) is used in degreasing solvents and spray adhesives. The adverse effects of 1-BP have been reported in human cases and adult animal models, and its developmental toxicity has also been reported, but its effects on developmental neurotoxicity have not been investigated in detail. We evaluated the effects in rat pups of prenatal exposure to 1-BP on behaviors such as scratching and wet dog shakes (WDS), which were induced by injection of kainate (KA). Pregnant Wistar rats were exposed to vaporized 1-BP with 700 ppm from gestation day 1 to day 20 (6 h/day). KA at doses of 0.1, 0.5, and 2.0 mg/kg were intraperitoneally injected into a control group and a 1-BP-exposed group of pups on postnatal day 14. There was no significant difference in scratching between the control and the prenatally 1-BP-exposed groups, while suppression of the occurrence ratio of WDS was observed at the low dose of 0.1 mg/kg of KA in the prenatally 1-BP-exposed pups. Our results suggest that prenatal exposure to 1-BP affects neurobehavioral responses in the juvenile period.


Assuntos
Comportamento Animal/efeitos dos fármacos , Discinesia Induzida por Medicamentos/etiologia , Exposição por Inalação/efeitos adversos , Ácido Caínico/efeitos adversos , Transtornos Mentais/induzido quimicamente , Efeitos Tardios da Exposição Pré-Natal/induzido quimicamente , Animais , Feminino , Hidrocarbonetos Bromados/efeitos adversos , Hidrocarbonetos Bromados/metabolismo , Hidrocarbonetos Bromados/toxicidade , Masculino , Troca Materno-Fetal , Gravidez , Ratos Wistar
14.
J Occup Health ; 57(1): 13-9, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25422129

RESUMO

OBJECTIVE: Sensor characteristics and performance of three real-time monitors for volatile organic compounds (VOC monitor) equipped with a photo ionization detector (PID), a sensor using the interference enhanced reflection (IER) method and a semiconductor gas sensor were investigated for 52 organic solvent vapors designated as class 1 and class 2 of organic solvents by the Ordinance of Organic Solvent Poisoning Prevention in Japan. METHODS: Test vapors were prepared by injecting each liquid solvent into a 50 l Tedlar® bag and perfectly vaporizing it. The vapor concentration was from one-tenth to twice the administrative control level for all solvents. The vapor concentration was measured with the monitors and a gas chromatograph equipped with a flame ionization detector simultaneously, and the values were compared. RESULTS: The monitor with the PID sensor could measure many organic vapors, but it could not detect some vapors with high ionization potential. The IER sensor could also detect many vapors, but a linear response was not obtained for some vapors. A semiconductor sensor could detect methanol that could not be detected by PID and IER sensors. CONCLUSIONS: Working environment measurement of organic vapors by real-time monitors may be possible, but sensor characteristics and their limitations should be known.


Assuntos
Monitoramento Ambiental/métodos , Compostos Orgânicos Voláteis/análise , Poluição do Ar em Ambientes Fechados/análise , Cromatografia Gasosa , Ionização de Chama , Gases/análise , Humanos , Japão , Exposição Ocupacional/prevenção & controle , Solventes/classificação , Volatilização
15.
Sangyo Eiseigaku Zasshi ; 56(6): 237-44, 2014.
Artigo em Japonês | MEDLINE | ID: mdl-25212434

RESUMO

OBJECTIVE: Bacteria on the facepiece of a dust respirator were measured just after use and after 24-hours storage at a room temperature after being worn, and bacteria disinfection methods other than ethanol were examined. METHODS: The existence of bacteria on a facepiece of a mask that had been worn for about one hour in a laboratory was investigated. In order to eliminate bacteria before use on the next day, five methods of bacteria disinfection were investigated: wiping with a facial tissue impregnated with ethanol as a control; wiping with a facial tissue wetted with tap water; wiping with a dry facial tissue after wiping with one wetted with tap water; wiping with a dry facial tissue after wiping with one wetted with distilled water; and wiping with a dry facial tissue two times. The tests were carried out using silicone rubber sheets plated with bacteria collected from human skin. The disinfection methods that were as effective as facial paper wetted with ethanol, were then assayed on the facepiece of the dust respirator. RESULTS: Bacteria were detected on the facepiece immediately after it had been worn. Bacteria were also detected on the facepiece after it had been stored at 25°C for 24-hours after being worn. The methods of wiping with a dry facial tissue after wiping with either tap water or distilled water were almost as statistically effective as wiping with ethanol wetted facial paper. Bacteria on the facepiece were decreased by wiping with a dry facial tissue after wiping with one wetted with tap water. DISCUSSION: Colonies of bacteria were detected on a facepiece that had been stored 24 hours after being worn, which suggests that bacteria disinfection just after a respirator has been worn should be recommended. It is very important that the water on the facepiece should be removed after wiping with a wet facial tissue.


Assuntos
Bactérias/isolamento & purificação , Desinfecção/métodos , Poeira , Máscaras/microbiologia , Dispositivos de Proteção Respiratória/microbiologia , Contagem de Colônia Microbiana , Etanol , Humanos , Masculino , Pele/microbiologia , Temperatura , Fatores de Tempo , Água
16.
J UOEH ; 35(4): 267-72, 2013 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-24334693

RESUMO

Performance and sensor characteristics of a monitor for volatile organic compounds (VOC monitor) using the interference enhanced reflection (IER) method were investigated for 52 organic solvent vapors that are designated as class 1 and class 2 organic solvents by the Ordinance of Organic Solvent Poisoning Prevention in Japan. Test vapors were prepared by injecting 1 to 3 µl of liquid solvent into a 20 l Tedlar(®) bag and perfectly vaporizing them. The vapor concentration was simultaneously measured with the monitor and a gas chromatograph (GC) equipped with flame ionization detector, and both values were compared. The monitor could detect all the solvent vapors that we used. Linear response was obtained between the concentration measured by the monitor and those by the GC. The monitor could detect 1/10 of the administrative control level for 37 of 52 solvent vapors, including toluene and xylenes. For 15 vapors, on the other hand, the monitor could not be used for the working environment measurement because the sensor response was low or the regression lines did not pass through the origin.


Assuntos
Técnicas de Química Analítica/métodos , Compostos Orgânicos Voláteis/análise , Cromatografia Gasosa , Sistemas Computacionais , Monitoramento Ambiental/métodos , Ionização de Chama , Solventes/análise , Local de Trabalho
17.
Environ Health Prev Med ; 18(4): 285-92, 2013 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-23184473

RESUMO

OBJECTIVE: Real time monitoring of total volatile organic compounds (TVOC) in rooms of Japanese university buildings was carried out to understand the temporal changes in actual indoor air quality. METHODS: The TVOC concentrations in seven different rooms, consisting of a lecture room, a seminar room, three laboratories, a computer room and a library, were monitored continuously for 24 h via a personal VOC monitor equipped with a semiconductor gas sensor. An active sampling-thermal desorption method using stainless steel tubes packed with Tenax-TA was also carried out simultaneously to verify the usability of the monitor. RESULTS: The TVOC concentrations measured by the personal VOC monitor were closely correlated with those measured by the active sampling method. The TVOC concentration in all rooms was generally low during the day and increased during the night. This concentration change corresponded to the ventilation cycle in the building. During the day, the TVOC concentration was generally lower than the provisional target criterion (advisable value) of indoor air quality in Japan (400 µg/m³). During the night, however, it exceeded this criterion in several rooms, especially during the summer season. CONCLUSION: The real-time monitor using a semiconductor gas sensor can provide useful data on changes in the TVOC concentration in indoor air with high sensitivity.


Assuntos
Poluentes Atmosféricos/análise , Poluição do Ar em Ambientes Fechados/análise , Monitoramento Ambiental/métodos , Compostos Orgânicos Voláteis/análise , Monitoramento Ambiental/instrumentação , Japão , Estações do Ano , Semicondutores , Fatores de Tempo , Universidades
18.
J UOEH ; 34(4): 363-8, 2012 Dec 01.
Artigo em Japonês | MEDLINE | ID: mdl-23270260

RESUMO

Measurements of organic solvents in the work environment are carried out by either direct sampling using plastic bags/gas chromatography, solid sorbent adsorption using charcoal tubes/gas chromatography, or by a direct reading method using detector tubes. However, these methods cannot always measure the work environment accurately because the concentration of hazardous materials changes from time to time, and from space to space. In this study, the sensor characteristics of a real time monitor using a photoionization detector that can monitor vapor concentration continuously were investigated for 52 organic solvent vapors that are required to be measured in the work environment by the Ordinance of Organic Solvent Poisoning Prevention in Japan. The sensitivity of the monitor was high for the solvents with low ionization potential. However, the sensitivity for the solvents with high ionization potential was low, and the sensor could not detected 7 solvents. Calibration of the sensor using a standard gas was desirable before being used for measurement because the sensitivity of the sensor was variable.


Assuntos
Poluição do Ar em Ambientes Fechados/análise , Técnicas de Química Analítica/instrumentação , Monitoramento Ambiental/instrumentação , Solventes/análise , Sistemas Computacionais , Local de Trabalho
19.
J UOEH ; 33(4): 331-6, 2011 Dec 01.
Artigo em Japonês | MEDLINE | ID: mdl-22259838

RESUMO

The hood performance of a local exhaust ventilation system is determined by the capture velocity and the air flow rate. The equation proposed by Dalla Valle has been widely used to speculate this relationship. However, Dalla Valle used different formulae for slot and plain opening (rectangular) hoods, and the calculated values near the boundary between the slot and plain opening by these formulae do not always match each other. In this study, we measured capture velocity of four hoods by changing the distance from the hood face for different aspect ratios. We also tried to develop an empirical formula to express a relationship that could be applied to both types of hoods. As a result, it was found that the relationship between air velocity in front of exterior hoods and air flow rate could be expressed as the sum of two exponential functions with distance. In addition, when the hood aspect ratio was less than 9 the values of the capture velocity calculated by the proposed equation were in good agreement with the experimental ones.


Assuntos
Movimentos do Ar , Desenho de Equipamento/métodos , Ventilação/instrumentação
20.
J Occup Health ; 52(2): 125-31, 2010.
Artigo em Inglês | MEDLINE | ID: mdl-20179378

RESUMO

OBJECTIVES: Thermal reconditioning characteristics of organic vapors from a respirator cartridge were studied by introducing humid air into a cartridge that had adsorbed organic vapors in order to develop a thermal reconditioning method. METHODS: Five different organic vapors (methanol, 2-propanol, acetone, dichloromethane and methyl acetate), most of which have relatively weak adsorption affinity to charcoal, were used in this study. Adsorption was carried out at a temperature of 25 degrees C. The relative humidity of the adsorption air with organic vapor was 50%. When the vapor concentration in the downstream of the respirator exceeded the breakthrough concentration, that is, the occupational exposure limits in Japan, the vapor supply was stopped. Then, desorption was started by introducing clean humid air from opposite side of the cartridge under a heated condition. When the desorbed vapor concentration fell below the limit of quantification, desorption process was ended and the next adsorption cycle was started after the temperature had returned to room temperature. This adsorption - desorption cycle was repeated more than three times. The desorption temperature was 65 degrees C and the relative humidity of desorption air was 20%, 50% or 70% at 25 degrees C. RESULTS: When the relative humidity was 20%, the breakthrough times of regenerated cartridges were shorter than that of a new one, but no difference was observed in the breakthrough curves when the relative humidity was greater than 50%. CONCLUSION: The results suggest that the thermal reconditioning of respirator cartridges using humid air is possible for these vapors.


Assuntos
Adsorção , Gases/análise , Umidade , Solventes , Termodinâmica , Ventiladores Mecânicos/normas , Carvão Vegetal , Humanos , Japão , Intoxicação/prevenção & controle , Equipamentos de Proteção , Dispositivos de Proteção Respiratória , Solventes/intoxicação , Volatilização
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...