Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Hazard Mater ; 278: 75-81, 2014 Aug 15.
Artigo em Inglês | MEDLINE | ID: mdl-24953938

RESUMO

Five liters of sodium hypochlorite aqueous solution (12 mass%) was poured into 300 L of liquid waste containing ammonium ion of about 1.8 mol/L in a 500 L tank in a plant area; then, two minutes later the solution exploded with a flash on March 30th, 2005. The tank cover, the fluorescent lamp and the air duct were broken by the blast wave. Thus, we have conducted 40 runs of laboratory-scale explosion tests under various conditions (solution concentrations of (NH4)2SO4 and NaClO, temperatures, Pt catalysts, pH, etc.) to investigate the causes for such an explosion. When solutions of ammonium sulfate and sodium hypochlorite are mixed in the presence of platinum black, explosions result. This is ascribable to the formation of explosive nitrogen trichloride (NCl3). In the case where it is necessary to mix these 2 solutions (ammonium sulfate and sodium hypochlorite) in the presence of platinum black, the following conditions would reduce a probability of explosion; the initial concentration of NH4(+) should be less than 3 mol/L and the pH should be higher than 6. The hypochlorite solution (in 1/10 in volume) to be added at room temperature is recommended to be less than 0.6 mol/L.


Assuntos
Sulfato de Amônio/química , Vazamento de Resíduos Químicos , Cloretos/química , Explosões , Compostos de Nitrogênio/química , Platina/química , Hipoclorito de Sódio/química , Cromatografia Gasosa-Espectrometria de Massas , Espectroscopia de Infravermelho com Transformada de Fourier , Resíduos
2.
Nihon Hoshasen Gijutsu Gakkai Zasshi ; 62(4): 513-21, 2006 Apr 20.
Artigo em Japonês | MEDLINE | ID: mdl-16639393

RESUMO

UNLABELLED: The effects of imaging conditions and measures for their improvement were examined with regard to recognition of the effects of contrast on images when T1-weighted imaging with selective fat suppression was applied. METHOD: Luminance at the target region was examined before and after contrast imaging using phantoms assuming pre- and post-imaging conditions. A clinical examination was performed on tumors revealed by breast examination, including those surrounded by mammary gland and by fat tissue. RESULTS: When fat suppression was used and imaging contrast was enhanced, the luminance level of fat tumors with the same structure as the prepared phantoms appeared to be high both before and after contrast imaging, and the effects of contrast were not distinguishable. This observation is attributable to the fact that the imaging conditions before and after contrast imaging were substantially different. To make a comparison between pre- and post-contrast images, it is considered necessary to perform imaging with fixed receiver gain and to apply the same imaging method for pre- and post-contrast images by adjusting post-contrast imaging conditions to those of pre-contrast imaging.


Assuntos
Tecido Adiposo/patologia , Neoplasias da Mama/diagnóstico , Mama/patologia , Aumento da Imagem/métodos , Imageamento por Ressonância Magnética/métodos , Meios de Contraste , Gadolínio DTPA , Humanos , Imagens de Fantasmas
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...