1.
Radiol Phys Technol ; 13(2): 170-176, 2020 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-32361900

RESUMO

A novel traceable point-like 68Ge/68Ga source was developed for calibration of positron emission tomography (PET) scanners. The source was equipped with a spherically symmetric acrylic positron absorber. The physical characteristics of photons emitted from the point-like source were evaluated by Monte Carlo simulation, considering possible geometrical uncertainties. The calibration factor of a clinical PET/CT scanner was evaluated using four manufactured point-like sources as a practical application of the point-like source. The results were consistent with that determined by the conventional cross-calibration method. The traceable point-like 68Ge/68Ga source is expected to be a simple and practical tool for determining the calibration factor and evaluating the physical characteristics of PET scanners.


Assuntos
Radioisótopos de Gálio , Germânio , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/instrumentação , Radioisótopos , Calibragem , Método de Monte Carlo
2.
Appl Radiat Isot ; 134: 89-94, 2018 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-29066214

RESUMO

Possible extended utilization of a 68Ge/68Ga source as a surrogate 18F reference source was studied. Some effects and uncertainties might arise from the difference of constructions between chambers that were used in the source calibration and those practically in use. To extend utilization of the surrogate source, response ratio of real 18F to 68Ge/68Ga sources were determined for three models of chambers. Monte-Carlo simulation using EGS5 code was also carried out to evaluate uncertainties expected. The present result shows that such a surrogate source would adapt to calibration even for chambers have with different construction from the reference chamber used as the determination of 18F equivalent activity of the 68Ge/68Ga surrogate source.

3.
Appl Radiat Isot ; 126: 93-99, 2017 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-28237291

RESUMO

A food inspection service system for home grown products or wild plants collected by individual consumers for self-consumption was implemented in Fukushima in Nov. 2012. About 500 NaI(Tl) scintillation spectrometers were distributed to 300 or more temporary testing laboratories which were set up in public halls or meeting places of the municipalities. The screening method for radiocaesium was adapted to the present inspection service system. The performance of the equipment under field conditions was evaluated using sampled data obtained by temporary testing laboratories. From the present results of evaluation the confidence of these inspections was confirmed. Totally about 550,000 food samples have been tested with a pass rate of 90% or more.


Assuntos
Radioisótopos de Césio/análise , Contaminação Radioativa de Alimentos/análise , Acidente Nuclear de Fukushima , Radiometria/métodos , Animais , Peixes , Inspeção de Alimentos/métodos , Inspeção de Alimentos/normas , Humanos , Japão , Plantas Comestíveis/química , Plantas Comestíveis/crescimento & desenvolvimento , Plantas Comestíveis/efeitos da radiação , Controle de Qualidade , Radiometria/normas , Contagem de Cintilação/métodos , Contagem de Cintilação/normas
4.
Appl Radiat Isot ; 70(9): 1959-63, 2012 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-22424745

RESUMO

Calibrations of instrument efficiency of surface contamination meters are usually made with extended reference sources which are standardized in terms of 2π surface ß-particle emission rates from the source surface including backscattered particles. Extended sources supplied from various metrology institutes or calibration laboratories, but the source-types such as structure, preparation method, backing and covering materials vary between manufacturers. In this work first we show how the calibration results are dependent on the source type. Second, in order to clarify the possible reason of such discrepancy, we examined the isotropy of ß-particle fluences by the use of a proportional counter and also observed the angular dependence of ß-particle spectra by the use of small plastic scintillation spectrometer, where the source mount can rotate relative to the detector window at various obliquities. The discrepancy in the instrument-calibration of surface contamination meters, which are mainly used under the conditions of large source-to-detector geometry, can be explained.


Assuntos
Partículas beta , Radiometria/instrumentação , Radiometria/normas , Desenho de Equipamento , Análise de Falha de Equipamento , Internacionalidade , Doses de Radiação , Padrões de Referência , Valores de Referência