Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 204
Filtrar
1.
J Cardiovasc Dev Dis ; 11(6)2024 Jun 03.
Artigo em Inglês | MEDLINE | ID: mdl-38921673

RESUMO

(1) Introduction: Digitalis use in patients with severe heart failure is controversial. We assessed the effects of digitalis therapy on mortality in a large, observational study in recipients of cardiac resynchronization therapy (CRT). (2) Methods: Consecutive patients receiving a CRT-defibrillator in three European tertiary referral centers were enrolled and followed-up for a mean 37 months ± 28 months. Digitalis use was assessed at the time of CRT implantation. A multivariate Cox-regression model and propensity score matching were used to determine all-cause mortality as the primary endpoint. CRT-response (defined as improvement of ≥1 NYHA class), echocardiographic improvement (defined as improvement of LVEF of ≥ 5%) and incidence of ICD shocks and rehospitalization were assessed as secondary endpoints in a subgroup of patients. (3) Results: The study comprised 552 CRT-recipients with standard indications, including 219 patients (40%) treated with digitalis. Compared to patients without digitalis, they had more often atrial fibrillation, poorer LVEF and a higher NYHA class (all p ≤ 0.002). Crude analysis of all-cause mortality demonstrated a similar relative risk of death for patients with and without digitalis (HR = 1.14; 95% CI 0.88-1.5; p = 0.40). After adjustment for independent predictors of mortality, digitalis therapy did not alter the risk for death (adjusted HR = 1.04; 95% CI 0.75-1.45; p = 0.82). Furthermore, in comparison to 286 propensity-score-matched patients, mortality was not affected by digitalis intake (propensity-adjusted HR = 1.11; 95% CI 0.72-1.70; p = 0.64). A CRT-response was predominant in digitalis non-users, concerning both improvement of HF symptoms and LVEF (NYHA p < 0.01; LVEF p < 0.01), while patients on digitalis had more often ventricular tachyarrhythmias requiring ICD shock (p = 0.01); although, rehospitalization for cardiac reasons was significantly lower among digitalis users compared to digitalis non-users (HR = 0.58; 95% C. I. 0.40-0.85; p = 0.01). (4) Conclusions: Digitalis therapy had no effect on mortality, but was associated with a reduced response to CRT and increased susceptibility to ventricular arrhythmias requiring ICD shock treatment. Although, digitalis administration positively altered the likelihood for cardiac rehospitalization during follow-up.

2.
Europace ; 26(6)2024 Jun 03.
Artigo em Inglês | MEDLINE | ID: mdl-38918179

RESUMO

AIMS: Persistent reluctance to perform magnetic resonance imaging (MRI) in patients with abandoned and/or epicardial leads of cardiac implantable electronic devices is related to in vitro studies reporting tip heating. While there is a plethora of data on the safety of MRI in conditional and non-conditional implantable devices, there is a clear lack of safety data in patients with abandoned and/or epicardial leads. METHODS AND RESULTS: Relevant literature was identified in Medline and CINAHL using the key terms 'magnetic resonance imaging' AND 'abandoned leads' OR 'epicardial leads'. Secondary literature and cross-references were supplemented. For reporting guidance, the Preferred Reporting Items for Systematic reviews and Meta-Analyses 2020 was used. International Prospective Register of Systematic Reviews (PROSPERO) registration number 465530. Twenty-one publications with a total of 656 patients with 854 abandoned and/or epicardial leads and 929 MRI scans of different anatomical regions were included. No scan-related major adverse cardiac event was documented, although the possibility of under-reporting of critical events in the literature should be considered. Furthermore, no severe device dysfunction or severe arrhythmia was reported. Mainly transient lead parameter changes were observed in 2.8% in the subgroup of patients with functional epicardial leads. As a possible correlate of myocardial affection, subjective sensations occurred mainly in the subgroup with abandoned epicardial leads (4.0%), but no change in myocardial biomarkers was observed. CONCLUSION: Existing publications did not report any relevant adverse events for MRI in patients with abandoned and/or epicardial leads if performed according to strict safety guidelines. However, a more rigorous risk-benefit calculation should be made for patients with epicardial leads.


Assuntos
Desfibriladores Implantáveis , Imageamento por Ressonância Magnética , Marca-Passo Artificial , Humanos , Imageamento por Ressonância Magnética/efeitos adversos , Segurança do Paciente
3.
Open Heart ; 11(1)2024 Feb 05.
Artigo em Inglês | MEDLINE | ID: mdl-38316493

RESUMO

OBJECTIVES: Assess safety and performance of novel quadripolar preshaped left ventricular (LV) leads: NAVIGO 4LV 2D ('S shaped') and NAVIGO 4LV ARC ('U shaped'). METHODS: Patients indicated for cardiac resynchronisation therapy were enrolled in a multicentre, prospective, controlled study (NAVIGATOR, NCT03279484). Patients were implanted with either a NAVIGO 4LV 2D or ARC lead, and assessed at 10 weeks, 6, 12 and 24 months post-implant. Co-primary safety and performance endpoints were assessed at 10 weeks. Safety endpoint was the patients' rate free from lead-related complications. Performance endpoint was the rate of patients with successful lead performance, defined as LV pacing threshold ≤2.5 V at 0.5 ms on at least one pacing vector, and the absence of phrenic nerve stimulation at the final programmed configuration. Lead-related complications and electrical parameters were monitored throughout study. RESULTS: A NAVIGO 4LV lead was successfully implanted in 211 out of 217 patients (97.2%). The safety endpoint was met, with 100% and 96.1% of patients free from complications for NAVIGO 4LV 2D and ARC, respectively. The performance endpoint was met with 98.1% and 98.9% of patients with a successful lead performance for NAVIGO 4LV 2D and ARC, respectively. Over 12 months, the global complication-free rate for both leads was 97.1% (95% CI: 93.71% to 98.70%), with a mean pacing capture threshold of 1.23 V±0.73 V and a mean impedance of 951 Ω±300.1 Ω. CONCLUSION: A high implantation success rate and low complication rate was reported for the novel NAVIGO 4LV 2D and ARC leads, along with successful performance up to 12 months.


Assuntos
Terapia de Ressincronização Cardíaca , Insuficiência Cardíaca , Humanos , Estudos Prospectivos , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/terapia , Insuficiência Cardíaca/etiologia , Terapia de Ressincronização Cardíaca/efeitos adversos , Dispositivos de Terapia de Ressincronização Cardíaca/efeitos adversos , Eletrodos Implantados/efeitos adversos
6.
Cerebrovasc Dis ; 53(1): 115-124, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-37276846

RESUMO

INTRODUCTION: The World Stroke Organization (WSO) Brain & Heart Task Force developed the Brain & hEart globAl iniTiative (BEAT), a pilot feasibility implementation program to establish clinical collaborations between cardiologists and stroke physicians who work at large healthcare facilities. METHODS: The WSO BEAT pilot project focused on atrial fibrillation (AF) and patent foramen ovale (PFO) detection and management, and poststroke cardiovascular complications known as the stroke-heart syndrome. The program included 10 sites from 8 countries: Brazil, China, Egypt, Germany, Japan, Mexico, Romania, and the USA The primary composite feasibility outcome was the achievement of the following 3 implementation metrics (1) developing site-specific clinical pathways for the diagnosis and management of AF, PFO, and the stroke-heart syndrome; (2) establishing regular Neurocardiology rounds (e.g., monthly); and (3) incorporating a cardiologist to the stroke team. The secondary objectives were (1) to identify implementation challenges to guide a larger program and (2) to describe qualitative improvements. RESULTS: The WSO BEAT pilot feasibility program achieved the prespecified primary composite outcome in 9 of 10 (90%) sites. The most common challenges were the limited access to specific medications (e.g., direct oral anticoagulants) and diagnostic (e.g., prolonged cardiac monitoring) or therapeutic (e.g., PFO closure devices) technologies. The most relevant qualitative improvement was the achievement of a more homogeneous diagnostic and therapeutic approach. CONCLUSION: The WSO BEAT pilot program suggests that developing neurocardiology collaborations is feasible. The long-term sustainability of the WSO BEAT program and its impact on quality of stroke care and clinical outcomes needs to be tested in a larger and longer duration program.


Assuntos
Fibrilação Atrial , Forame Oval Patente , Acidente Vascular Cerebral , Humanos , Projetos Piloto , Fatores de Risco , Cateterismo Cardíaco/efeitos adversos , Acidente Vascular Cerebral/diagnóstico , Acidente Vascular Cerebral/terapia , Acidente Vascular Cerebral/etiologia , Forame Oval Patente/diagnóstico , Forame Oval Patente/diagnóstico por imagem , Fibrilação Atrial/diagnóstico , Prevenção Secundária , Encéfalo , Resultado do Tratamento , Recidiva
7.
Eur Heart J Suppl ; 25(Suppl G): G44-G55, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37970517

RESUMO

Pacing from the right atrial appendage (RAA) prolongs the P wave duration and can induce interatrial and especially left-sided atrio-ventricular dyssynchrony. Pacing from Bachmann's bundle closely reproduces normal physiology and has the potential to avoid the electromechanical dysfunction associated with conventional RAA pacing. Interatrial conduction delay is associated with an increased risk of stroke, heart failure, and death. In addition to a reduction in atrial fibrillation, Bachmann's bundle pacing has emerging applications as a hemodynamic pacing modality. This review outlines the pathophysiology of atrial conduction disturbances and their potential remedies and provides the reader with a practical guide to implementing Bachmann's bundle pacing with an emphasis on the recapitulation of normal electrical and mechanical function.

8.
Herzschrittmacherther Elektrophysiol ; 34(3): 232-239, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37548688

RESUMO

Currently, most evidence assessments in guidelines or health technology assessments (HTAs) rely on the assumption that a randomized controlled trial (RCT) is always the best source of evidence. However, if the outcome in a control group is certain, e.g. death within a short time with an almost 100% chance, or if an event can only occur in the treatment group, there is no need for a randomized control group; the evidence cannot be improved by a control group, nor by an RCT design. If a cause-effect relationship is certain ("primary or direct evidence"), a therapeutic effect can be diluted in the population of an RCT by cross-over, etc. This can lead to serious misinterpretations of the effect. While experts such as the GRADE group or Cochrane institutes recommend using all available evidence, the leading approach in many guidelines and HTAs is assessing "the best available trials", i.e. RCTs. But since RCTs only deliver probabilities of cause-effect relationships, it is not appropriate to demand RCTs for certain effects. A control group can only diminish the net value of a treatment since the outcome in the control group is subtracted from the outcome in the treatment group. Therefore, under identical circumstances, an RCT will always show lower effect rates compared to a single arm study of the same quality, for desired as well as for adverse effects. Considering these inconsistencies in evidence-based medicine interpretation, the evidence pyramid with RCTs at the top is not always a reliable indicator for the best quality of evidence.


Assuntos
Medicina Baseada em Evidências , Humanos , Ensaios Clínicos Controlados Aleatórios como Assunto
9.
Europace ; 25(4): 1249-1276, 2023 04 15.
Artigo em Inglês | MEDLINE | ID: mdl-37061780

RESUMO

There is an increasing proportion of the general population surviving to old age with significant chronic disease, multi-morbidity, and disability. The prevalence of pre-frail state and frailty syndrome increases exponentially with advancing age and is associated with greater morbidity, disability, hospitalization, institutionalization, mortality, and health care resource use. Frailty represents a global problem, making early identification, evaluation, and treatment to prevent the cascade of events leading from functional decline to disability and death, one of the challenges of geriatric and general medicine. Cardiac arrhythmias are common in advancing age, chronic illness, and frailty and include a broad spectrum of rhythm and conduction abnormalities. However, no systematic studies or recommendations on the management of arrhythmias are available specifically for the elderly and frail population, and the uptake of many effective antiarrhythmic therapies in these patients remains the slowest. This European Heart Rhythm Association (EHRA) consensus document focuses on the biology of frailty, common comorbidities, and methods of assessing frailty, in respect to a specific issue of arrhythmias and conduction disease, provide evidence base advice on the management of arrhythmias in patients with frailty syndrome, and identifies knowledge gaps and directions for future research.


Assuntos
Fragilidade , Humanos , Idoso , Fragilidade/diagnóstico , Fragilidade/epidemiologia , Fragilidade/terapia , Idoso Fragilizado , Consenso , América Latina , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/epidemiologia , Arritmias Cardíacas/terapia , Doença do Sistema de Condução Cardíaco
10.
Europace ; 25(4): 1208-1236, 2023 04 15.
Artigo em Inglês | MEDLINE | ID: mdl-37061848

RESUMO

Conduction system pacing (CSP) has emerged as a more physiological alternative to right ventricular pacing and is also being used in selected cases for cardiac resynchronization therapy. His bundle pacing was first introduced over two decades ago and its use has risen over the last five years with the advent of tools which have facilitated implantation. Left bundle branch area pacing is more recent but its adoption is growing fast due to a wider target area and excellent electrical parameters. Nevertheless, as with any intervention, proper technique is a prerequisite for safe and effective delivery of therapy. This document aims to standardize the procedure and to provide a framework for physicians who wish to start CSP implantation, or who wish to improve their technique.


Assuntos
Terapia de Ressincronização Cardíaca , Sistema de Condução Cardíaco , Humanos , América Latina , Canadá , Doença do Sistema de Condução Cardíaco , Fascículo Atrioventricular
11.
Europace ; 25(4): 1237-1248, 2023 04 15.
Artigo em Inglês | MEDLINE | ID: mdl-37061850

RESUMO

Conduction system pacing (CSP) has emerged as a more physiological alternative to right ventricular pacing and is also being used in selected cases for cardiac resynchronization therapy. His bundle pacing was first introduced over two decades ago and its use has risen over the last years with the advent of tools which have facilitated implantation. Left bundle branch area pacing is more recent but its adoption is growing fast due to a wider target area and excellent electrical parameters. Nevertheless, as with any intervention, proper technique is a prerequisite for safe and effective delivery of therapy. This document aims to standardize the procedure and to provide a framework for physicians who wish to start CSP implantation, or who wish to improve their technique. A synopsis is provided in this print edition of EP-Europace. The full document may be consulted online, and a 'Key Messages' App can be downloaded from the EHRA website.


Assuntos
Sistema de Condução Cardíaco , Humanos , Canadá , Doença do Sistema de Condução Cardíaco , Ásia
12.
Circulation ; 147(9): 759-767, 2023 02 28.
Artigo em Inglês | MEDLINE | ID: mdl-36848410

RESUMO

The notion that the risk of sudden cardiac death (SCD) in patients with heart failure (HF) is declining seems to be gaining traction. Numerous editorials and commentaries have suggested that SCD, specifically arrhythmic SCD, is no longer a significant risk for patients with HF on guideline-directed medical therapy. In this review, we question whether the risk of SCD has indeed declined in HF trials and in the real world. We also explore whether, despite relative risk reductions, the residual SCD risk after guideline-directed medical therapy still suggests a need for implantable cardioverter defibrillator therapy. Among our arguments is that SCD has not decreased in HF trials, nor in the real world. Moreover, we argue that data from HF trials, which have not adhered to guideline-directed device therapy, do not obviate or justify delays to implantable cardioverter defibrillator therapy. In this context, we underline the challenges of translating the findings of HF randomized, controlled trials of guideline-directed medical therapy to the real world. We also make the case for HF trials that adhere to current guideline-directed device therapy so that we can better understand the role of implantable cardioverter defibrillators in chronic HF.


Assuntos
Desfibriladores Implantáveis , Insuficiência Cardíaca , Humanos , Insuficiência Cardíaca/complicações , Insuficiência Cardíaca/terapia , Morte Súbita Cardíaca/epidemiologia , Morte Súbita Cardíaca/etiologia , Morte Súbita Cardíaca/prevenção & controle
13.
Europace ; 25(3): 1077-1086, 2023 03 30.
Artigo em Inglês | MEDLINE | ID: mdl-36352513

RESUMO

Guidelines recommend patients undergoing a first pacemaker implant who have even mild left ventricular (LV) impairment should receive biventricular or conduction system pacing (CSP). There is no corresponding recommendation for patients who already have a pacemaker. We conducted a meta-analysis of randomized controlled trials (RCTs) and observational studies assessing device upgrades. The primary outcome was the echocardiographic change in LV ejection fraction (LVEF). Six RCTs (randomizing 161 patients) and 47 observational studies (2644 patients) assessing the efficacy of upgrade to biventricular pacing were eligible for analysis. Eight observational studies recruiting 217 patients of CSP upgrade were also eligible. Fourteen additional studies contributed data on complications (25 412 patients). Randomized controlled trials of biventricular pacing upgrade showed LVEF improvement of +8.4% from 35.5% and observational studies: +8.4% from 25.7%. Observational studies of left bundle branch area pacing upgrade showed +11.1% improvement from 39.0% and observational studies of His bundle pacing upgrade showed +12.7% improvement from 36.0%. New York Heart Association class decreased by -0.4, -0.8, -1.0, and -1.2, respectively. Randomized controlled trials of biventricular upgrade found improvement in Minnesota Heart Failure Score (-6.9 points) and peak oxygen uptake (+1.1 mL/kg/min). This was also seen in observational studies of biventricular upgrades (-19.67 points and +2.63 mL/kg/min, respectively). In studies of the biventricular upgrade, complication rates averaged 2% for pneumothorax, 1.4% for tamponade, and 3.7% for infection over 24 months of mean follow-up. Lead-related complications occurred in 3.3% of biventricular upgrades and 1.8% of CSP upgrades. Randomized controlled trials show significant physiological and symptomatic benefits of upgrading pacemakers to biventricular pacing. Observational studies show similar effects between biventricular pacing upgrade and CSP upgrade.


Assuntos
Terapia de Ressincronização Cardíaca , Insuficiência Cardíaca , Marca-Passo Artificial , Disfunção Ventricular Esquerda , Humanos , Terapia de Ressincronização Cardíaca/efeitos adversos , Estimulação Cardíaca Artificial/efeitos adversos , Doença do Sistema de Condução Cardíaco/terapia , Sistema de Condução Cardíaco , Função Ventricular Esquerda , Volume Sistólico/fisiologia , Resultado do Tratamento , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/terapia
15.
Herzschrittmacherther Elektrophysiol ; 33(4): 446-449, 2022 Dec.
Artigo em Alemão | MEDLINE | ID: mdl-36283993

RESUMO

In a subset of patients with pacemaker models Assurity® and Endurity® (Abbott, Sylmar, California, USA; worldwide outside the USA approximately 83,000 devices), a mistake during production may have occurred resulting in insufficient adhesion between the pulse generator header and device housing which in turn may allow moisture to enter the header. This may cause loss of telemetry, switch to back-up mode, reduced battery longevity, or in worst case loss of pacing. Until June 2022, these malfunctions were reported for 128 devices worldwide (0.15%); no permanent harm to patients due to this issue has been reported. The nucleus of the AGEP suggests the following recommendations: (1) Patients with a device under safety advisory should be informed. (2) The risks for the patient in case of loss of stimulation should be assessed. Patients should be categorized into "likely pacemaker-dependent" (e.g., indication permanent atrioventricular [AV] block, no intrinsic rhythm at the last follow-up, percentage of ventricular pacing in the device memory > 90%), "unknown", or "likely not pacemaker-dependent" (e.g., indication sick sinus syndrome, intrinsic rhythm > 50 bpm at the last follow-up, percentage of ventricular pacing in the device memory < 1%). (3) In likely pacemaker-non-dependent patients, information about this issue should be provided together with an unchanged follow-up or a follow-up with shortened intervals (e.g., every 3 months) and/or remote monitoring. (4) In patients with unknown risk if stimulation failure occurs, at least follow-up intervals should be shortened to, for example, 3 months and/or remote monitoring should be initialized. In addition, risks and benefits of a device exchange should be weighed against each other. (5) In patients who are likely pacemaker-dependent, device exchange is recommended.


Assuntos
Bloqueio Atrioventricular , Marca-Passo Artificial , Humanos , Síndrome do Nó Sinusal , Marca-Passo Artificial/efeitos adversos , Bloqueio Atrioventricular/terapia , Eletrofisiologia Cardíaca , Ventrículos do Coração , Estimulação Cardíaca Artificial/métodos
18.
Heart Fail Rev ; 27(6): 2165-2176, 2022 11.
Artigo em Inglês | MEDLINE | ID: mdl-35670890

RESUMO

Cardiac resynchronization therapy (CRT) may improve not only impaired left ventricular contractility but can also induce reverse remodeling of native conduction system. Measurement of intrinsic QRS complex width during follow-up is the simplest method to assess reverse electrical remodeling (RER). We aimed to provide a literature review and meta-analysis on incidence and impact of RER and its association with mechanical remodeling. A systematic review and random-effect meta-analysis of studies reporting data on RER was performed. A total of 16 studies were included in this meta-analysis with 930 patients undergoing CRT (mean age 64.0 years, 64.1% males). The weighted mean incidence of RER was 42%. Reverse mechanical remodeling assessed by echocardiography was more frequently observed in patients with RER compared to patients without RER (75.7% vs. 46.6%; odds ratio [OR] 3.7, 95% confidence interval [CI] 2.24-6.09, p < 0.01). Mechanical responders had a mean iQRS shortening of 7.7 ms, while mechanical non-responders experienced a mean widening of iQRS by 5.2 ms (p < 0.01). Clinical improvement was more frequent in patients with RER vs. patients without RER (82.9% vs. 49.0%; OR 5.26; 95% CI 2.92-9.48; p < 0.01). No significant difference in all-cause mortality between patients with and without RER was found. Mean difference between baseline intrinsic QRS and post-implantation paced QRS was significant in patients with later RER (21.2 ms, 95% CI 9.4-32.9, p < 0.01), but not in patients without RER (6.6 ms, 95% CI -2.2-15.4, p = 0.14). Gender, initial left bundle block morphology and heart failure etiology were found not to be predictive for RER. Our meta-analysis demonstrates that shortening of iQRS duration is a common finding during follow-up of patients undergoing CRT and is associated with mechanical reverse remodeling and clinical improvement. Clinical Trial Registration: Prospero Database-CRD42021253336.


Assuntos
Terapia de Ressincronização Cardíaca , Insuficiência Cardíaca , Terapia de Ressincronização Cardíaca/métodos , Eletrocardiografia/métodos , Feminino , Sistema de Condução Cardíaco , Humanos , Masculino , Pessoa de Meia-Idade , Resultado do Tratamento , Remodelação Ventricular
20.
Herzschrittmacherther Elektrophysiol ; 33(3): 319-326, 2022 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-35763099

RESUMO

To understand the position of a pacing lead in the right ventricle and to correctly interpret fluoroscopy and intracardiac signals, good anatomical knowledge is required. The right ventricle can be separated into an inlet, an outlet, and an apical compartment. The inlet and outlet are separated by the septomarginal trabeculae, while the apex is situated below the moderator band. A lead position in the right ventricular apex is less desirable, last but not least due to the thin myocardial wall. Many leads supposed to be implanted in the apex are in fact fixed rather within the trabeculae in the inlet, which are sometimes difficult to pass. In the right ventricular outflow tract (RVOT), the free wall is easier to reach than the septal due to the fact that the RVOT wraps around the septum. A mid-septal position close to the moderator band is relatively simple to achieve and due to the vicinity of the right bundle branch may produce a narrower paced QRS complex. Special and detailed knowledge is necessary for His bundle and left bundle branch pacing.


Assuntos
Ventrículos do Coração , Septo Interventricular , Estimulação Cardíaca Artificial , Eletrocardiografia , Sistema de Condução Cardíaco , Ventrículos do Coração/cirurgia , Humanos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...