Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Diagnostics (Basel) ; 10(1)2020 Jan 13.
Artigo em Inglês | MEDLINE | ID: mdl-31941079

RESUMO

In this paper, we propose an analytical rapid method to estimate the endocardial borders of the left ventricular walls on echocardiographic images for prospective clinical integration. The procedure was created as a diagnostic support tool for the clinician and it is based on the use of the anisotropic generalized Hough transform. Its application is guided by a Gabor-like filtering for the approximate delimitation of the region of interest without the need for computing further anatomical characteristics. The algorithm is applying directly a deformable template on the predetermined filtered region and therefore it is responsive and straightforward implementable. For accuracy considerations, we have employed a support vector machine classifier to determine the confidence level of the automated marking. The clinical tests were performed at the Cardiology Clinic of the County Emergency Hospital Timisoara and they improved the physicians perception in more than 50% of the cases. The report is concluded with medical discussions.

2.
Proc Eur Signal Process Conf EUSIPCO ; 26: 1337-1341, 2018 Dec 03.
Artigo em Inglês | MEDLINE | ID: mdl-30555797

RESUMO

The paper provides a theorem for the characterization of numerical stability of spline-type systems. These systems are generated through shifted copies of a given atom over a time lattice. Also, we reformulate the well known Gabor systems via modulated spline-type systems and we apply the corresponding numerical stability to these systems. The numerical stability is tested for consistency against deformations.

3.
Comput Anal Images Patterns ; 10425: 455-461, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-30547160

RESUMO

This is an experimental paper in which we introduce the possibility to analyze and to synthesize 3D medical images by using multi-variate Gabor frames with Gaussian windows. Our purpose is to apply a space-variant filter-like operation in the space-frequency domain to correct medical images corrupted by different types of acquisitions errors. The Gabor frames are constructed with Gaussian windows sampled on non-separable lattices for a better packing of the space-frequency plane. An implementable solution for 3D-Gabor frames with non-separable lattice is given and numerical tests on simulated data are presented.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...