Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 51
Filtrar
1.
Eur J Cardiothorac Surg ; 65(5)2024 May 03.
Artigo em Inglês | MEDLINE | ID: mdl-38710669

RESUMO

OBJECTIVES: The objective of this analysis was to assess the normal haemodynamic performance of contemporary surgical aortic valves at 1 year postimplant in patients undergoing surgical aortic valve replacement for significant valvular dysfunction. By pooling data from 4 multicentre studies, this study will contribute to a better understanding of the effectiveness of surgical aortic valve replacement procedures, aiding clinicians and researchers in making informed decisions regarding valve selection and patient management. METHODS: Echocardiograms were assessed by a single core laboratory. Effective orifice area, dimensionless velocity index, mean aortic gradient, peak aortic velocity and stroke volume were evaluated. RESULTS: The cohort included 2958 patients. Baseline age in the studies ranged from 70.1 ± 9.0 to 83.3 ± 6.4 years, and Society of Thoracic Surgeons risk of mortality was 1.9 ± 0.7 to 7.5 ± 3.4%. Twenty patients who had received a valve model implanted in fewer than 10 cases were excluded. Ten valve models (all tissue valves; n = 2938 patients) were analysed. At 1 year, population mean effective orifice area ranged from 1.46 ± 0.34 to 2.12 ± 0.59 cm2, and dimensionless velocity index, from 0.39 ± 0.07 to 0.56 ± 0.15. The mean gradient ranged from 8.6 ± 3.4 to 16.1 ± 6.2 mmHg with peak aortic velocity of 1.96 ± 0.39 to 2.65 ± 0.47 m/s. Stroke volume was 75.3 ± 19.6 to 89.8 ± 24.3 ml. CONCLUSIONS: This pooled cohort is the largest to date of contemporary surgical aortic valves with echocardiograms analysed by a single core lab. Overall haemodynamic performance at 1 year ranged from good to excellent. These data can serve as a benchmark for other studies and may be useful to evaluate the performance of bioprosthetic surgical valves over time. CLINICAL TRIAL REGISTRATION NUMBER: NCT02088554, NCT02701283, NCT01586910 and NCT01531374.


Assuntos
Valva Aórtica , Bioprótese , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Hemodinâmica , Humanos , Hemodinâmica/fisiologia , Valva Aórtica/cirurgia , Valva Aórtica/diagnóstico por imagem , Idoso , Feminino , Masculino , Idoso de 80 Anos ou mais , Implante de Prótese de Valva Cardíaca/métodos , Ecocardiografia , Pessoa de Meia-Idade , Desenho de Prótese
2.
Intern Med ; 2024 Mar 25.
Artigo em Inglês | MEDLINE | ID: mdl-38522908

RESUMO

A 70-year-old woman with anti-aminoacyl-tRNA synthetase (ARS) antibody-positive interstitial lung disease (ARS-ILD) received daily medications and regular cyclophosphamide cycles for recurring exacerbations. Approximately four years after immunosuppression initiation, the patient was admitted for progressive dyspnea on exertion. Chest computed tomography (CT) findings were suggestive of acute exacerbation. Despite intensified immunosuppressive treatment, the radiographic findings worsened, and serum Krebs von den Lungen-6 (KL-6) levels increased. A bronchoalveolar lavage fluid (BALF) examination revealed amorphous globules and alveolar macrophages with eosinophilic granules. Owing to negative anti-GM-CSF antibody tests, a diagnosis of secondary pulmonary alveolar proteinosis (PAP) was established.

3.
J Infect Chemother ; 30(8): 815-819, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38272261

RESUMO

This study aimed to clarify other diseases claimed simultaneously with acute upper respiratory infection (URI), antibiotic prescriptions, and examinations associated with infectious diseases in pediatric patients with acute URI insurance claims at otorhinolaryngology outpatient visits. Pediatric patients who visited an otolaryngology department between 2019 and 2021 and were definitively diagnosed with URI were selected using a large Japanese medical claims database. Patient backgrounds, antibiotic use, and examinations were descriptively evaluated. In total, 8010 patients were included in the analysis. The median number (interquartile range) of diseases claimed in the same month as acute URI was 4 (3-6). Only 519 (6.5 %) patients were claimed as acute URI alone. Regardless of the prescription of antibiotics, the most commonly redundantly claimed disease in these patients was allergic rhinitis, followed by acute bronchitis, acute sinusitis, and earwax impaction. The frequently prescribed antibiotics were third-generation cephalosporins, macrolides, and penicillins with extended-spectrum, including amoxicillin which was recommended by the Japanese manual; the proportion of patients with examinations was low (2.9-21.7 %). Among patients with acute URI, diagnoses requiring antibiotics were also claimed; therefore, when evaluating acute URI using the Japanese medical claims database, care must be taken in patient selection. Moreover, the implementation rate of examinations necessary for diagnosis was low, so there is an urgent need to develop an environment where examinations can be conducted in outpatient settings.


Assuntos
Antibacterianos , Bases de Dados Factuais , Infecções Respiratórias , Humanos , Japão/epidemiologia , Infecções Respiratórias/tratamento farmacológico , Infecções Respiratórias/diagnóstico , Infecções Respiratórias/epidemiologia , Criança , Feminino , Masculino , Pré-Escolar , Antibacterianos/uso terapêutico , Bases de Dados Factuais/estatística & dados numéricos , Lactente , Doença Aguda , Otolaringologia/estatística & dados numéricos , Adolescente , Encaminhamento e Consulta/estatística & dados numéricos , Sinusite/tratamento farmacológico , Revisão da Utilização de Seguros/estatística & dados numéricos , Bronquite/tratamento farmacológico , Bronquite/diagnóstico , População do Leste Asiático
4.
NPJ Digit Med ; 7(1): 4, 2024 Jan 06.
Artigo em Inglês | MEDLINE | ID: mdl-38182738

RESUMO

Assessment of left ventricular diastolic function plays a major role in the diagnosis and prognosis of cardiac diseases, including heart failure with preserved ejection fraction. We aimed to develop an artificial intelligence (AI)-enabled electrocardiogram (ECG) model to identify echocardiographically determined diastolic dysfunction and increased filling pressure. We trained, validated, and tested an AI-enabled ECG in 98,736, 21,963, and 98,763 patients, respectively, who had an ECG and echocardiographic diastolic function assessment within 14 days with no exclusion criteria. It was also tested in 55,248 patients with indeterminate diastolic function by echocardiography. The model was evaluated using the area under the curve (AUC) of the receiver operating characteristic curve, and its prognostic performance was compared to echocardiography. The AUC for detecting increased filling pressure was 0.911. The AUCs to identify diastolic dysfunction grades ≥1, ≥2, and 3 were 0.847, 0.911, and 0.943, respectively. During a median follow-up of 5.9 years, 20,223 (20.5%) died. Patients with increased filling pressure predicted by AI-ECG had higher mortality than those with normal filling pressure, after adjusting for age, sex, and comorbidities in the test group (hazard ratio (HR) 1.7, 95% CI 1.645-1.757) similar to echocardiography and in the indeterminate group (HR 1.34, 95% CI 1.298-1.383). An AI-enabled ECG identifies increased filling pressure and diastolic function grades with a good prognostic value similar to echocardiography. AI-ECG is a simple and promising tool to enhance the detection of diseases associated with diastolic dysfunction and increased diastolic filling pressure.

5.
J Vet Med Sci ; 86(2): 224-227, 2024 Feb 15.
Artigo em Inglês | MEDLINE | ID: mdl-38233130

RESUMO

In a windowless poultry house raising layer chickens in Kanagawa prefecture, Japan, a slight increase in the mortality of chickens and a decrease in egg production were observed. Necropsy revealed numerous tapeworms and proglottids in chicken intestines. Histopathologically, gut-associated lymphoid tissues were observed in the lamina propria of the jejunum; however, no significant changes were observed in the other organs. Numerous hide beetles, Dermestes maculatus DeGeer, intermediate hosts of Raillietina cesticillus, were observed in the poultry house. Following a decline in beetle numbers, egg production increased and chicken mortality decreased. The life cycle of a tapeworm was easily established in a closed space, such as a windowless house, which led to severe infections.


Assuntos
Cestoides , Infecções por Cestoides , Doenças das Aves Domésticas , Animais , Galinhas , Aves Domésticas , Infecções por Cestoides/veterinária
6.
Eur Heart J Digit Health ; 4(3): 196-206, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-37265870

RESUMO

Aims: An artificial intelligence-enabled electrocardiogram (AI-ECG) is a promising tool to detect patients with aortic stenosis (AS) before developing symptoms. However, functional, structural, or haemodynamic components reflected in AI-ECG responsible for its detection are unknown. Methods and results: The AI-ECG model that was developed at Mayo Clinic using a convolutional neural network to identify patients with moderate-severe AS was applied. In patients used as the testing group, the correlation between the AI-ECG probability of AS and echocardiographic parameters was investigated. This study included 102 926 patients (63.0 ± 16.3 years, 52% male), and 28 464 (27.7%) were identified as AS positive by AI-ECG. Older age, atrial fibrillation, hypertension, diabetes, coronary artery disease, and heart failure were more common in the positive AI-ECG group than in the negative group (P < 0.001). The AI-ECG was correlated with aortic valve area (ρ = -0.48, R2 = 0.20), peak velocity (ρ = 0.22, R2 = 0.08), and mean pressure gradient (ρ = 0.35, R2 = 0.08). The AI-ECG also correlated with left ventricular (LV) mass index (ρ = 0.36, R2 = 0.13), E/e' (ρ = 0.36, R2 = 0.12), and left atrium volume index (ρ = 0.42, R2 = 0.12). Neither LV ejection fraction nor stroke volume index had a significant correlation with the AI-ECG. Age correlated with the AI-ECG (ρ = 0.46, R2 = 0.22) and its correlation with echocardiography parameters was similar to that of the AI-ECG. Conclusion: A combination of AS severity, diastolic dysfunction, and LV hypertrophy is reflected in the AI-ECG to detect AS. There seems to be a gradation of the cardiac anatomical/functional features in the model and its identification process of AS is multifactorial.

7.
Open Heart ; 10(1)2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-37173100

RESUMO

OBJECTIVE: To evaluate whether transcatheter or surgical aortic valve replacement (TAVR or SAVR) affects clinical and haemodynamic outcomes in symptomatic patients with moderately-severe aortic stenosis (AS). METHODS: Echocardiographic evidence of severe AS for enrolment in the Evolut Low Risk trial was based on site-reported measurements. For this post hoc analysis, core laboratory measurements identified patients with symptomatic moderately-severe AS (1.0

Assuntos
Estenose da Valva Aórtica , Implante de Prótese de Valva Cardíaca , Humanos , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Implante de Prótese de Valva Cardíaca/efeitos adversos , Qualidade de Vida , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/etiologia , Resultado do Tratamento
8.
J Am Coll Cardiol ; 81(17): 1663-1674, 2023 05 02.
Artigo em Inglês | MEDLINE | ID: mdl-36882136

RESUMO

BACKGROUND: Randomized data comparing outcomes of transcatheter aortic valve replacement (TAVR) with surgery in low-surgical risk patients at time points beyond 2 years is limited. This presents an unknown for physicians striving to educate patients as part of a shared decision-making process. OBJECTIVES: The authors evaluated 3-year clinical and echocardiographic outcomes from the Evolut Low Risk trial. METHODS: Low-risk patients were randomized to TAVR with a self-expanding, supra-annular valve or surgery. The primary endpoint of all-cause mortality or disabling stroke and several secondary endpoints were assessed at 3 years. RESULTS: There were 1,414 attempted implantations (730 TAVR; 684 surgery). Patients had a mean age of 74 years and 35% were women. At 3 years, the primary endpoint occurred in 7.4% of TAVR patients and 10.4% of surgery patients (HR: 0.70; 95% CI: 0.49-1.00; P = 0.051). The difference between treatment arms for all-cause mortality or disabling stroke remained broadly consistent over time: -1.8% at year 1; -2.0% at year 2; and -2.9% at year 3. The incidence of mild paravalvular regurgitation (20.3% TAVR vs 2.5% surgery) and pacemaker placement (23.2% TAVR vs 9.1% surgery; P < 0.001) were lower in the surgery group. Rates of moderate or greater paravalvular regurgitation for both groups were <1% and not significantly different. Patients who underwent TAVR had significantly improved valve hemodynamics (mean gradient 9.1 mm Hg TAVR vs 12.1 mm Hg surgery; P < 0.001) at 3 years. CONCLUSIONS: Within the Evolut Low Risk study, TAVR at 3 years showed durable benefits compared with surgery with respect to all-cause mortality or disabling stroke. (Medtronic Evolut Transcatheter Aortic Valve Replacement in Low Risk Patients; NCT02701283).


Assuntos
Insuficiência da Valva Aórtica , Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Acidente Vascular Cerebral , Substituição da Valva Aórtica Transcateter , Humanos , Feminino , Idoso , Masculino , Valva Aórtica/cirurgia , Insuficiência da Valva Aórtica/cirurgia , Fatores de Risco , Resultado do Tratamento , Estudos Prospectivos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Próteses Valvulares Cardíacas/efeitos adversos , Acidente Vascular Cerebral/epidemiologia , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/cirurgia
9.
JAMA Cardiol ; 8(2): 111-119, 2023 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-36515976

RESUMO

Importance: The frequency and clinical importance of structural valve deterioration (SVD) in patients undergoing self-expanding transcatheter aortic valve implantation (TAVI) or surgery is poorly understood. Objective: To evaluate the 5-year incidence, clinical outcomes, and predictors of hemodynamic SVD in patients undergoing self-expanding TAVI or surgery. Design, Setting, and Participants: This post hoc analysis pooled data from the CoreValve US High Risk Pivotal (n = 615) and SURTAVI (n = 1484) randomized clinical trials (RCTs); it was supplemented by the CoreValve Extreme Risk Pivotal trial (n = 485) and CoreValve Continued Access Study (n = 2178). Patients with severe aortic valve stenosis deemed to be at intermediate or increased risk of 30-day surgical mortality were included. Data were collected from December 2010 to June 2016, and data were analyzed from December 2021 to October 2022. Interventions: Patients were randomized to self-expanding TAVI or surgery in the RCTs or underwent self-expanding TAVI for clinical indications in the nonrandomized studies. Main Outcomes and Measures: The primary end point was the incidence of SVD through 5 years (from the RCTs). Factors associated with SVD and its association with clinical outcomes were evaluated for the pooled RCT and non-RCT population. SVD was defined as (1) an increase in mean gradient of 10 mm Hg or greater from discharge or at 30 days to last echocardiography with a final mean gradient of 20 mm Hg or greater or (2) new-onset moderate or severe intraprosthetic aortic regurgitation or an increase of 1 grade or more. Results: Of 4762 included patients, 2605 (54.7%) were male, and the mean (SD) age was 82.1 (7.4) years. A total of 2099 RCT patients, including 1128 who received TAVI and 971 who received surgery, and 2663 non-RCT patients who received TAVI were included. The cumulative incidence of SVD treating death as a competing risk was lower in patients undergoing TAVI than surgery (TAVI, 2.20%; surgery, 4.38%; hazard ratio [HR], 0.46; 95% CI, 0.27-0.78; P = .004). This lower risk was most pronounced in patients with smaller annuli (23 mm diameter or smaller; TAVI, 1.32%; surgery, 5.84%; HR, 0.21; 95% CI, 0.06-0.73; P = .02). SVD was associated with increased 5-year all-cause mortality (HR, 2.03; 95% CI, 1.46-2.82; P < .001), cardiovascular mortality (HR, 1.86; 95% CI, 1.20-2.90; P = .006), and valve disease or worsening heart failure hospitalizations (HR, 2.17; 95% CI, 1.23-3.84; P = .008). Predictors of SVD were developed from multivariate analysis. Conclusions and Relevance: This study found a lower rate of SVD in patients undergoing self-expanding TAVI vs surgery at 5 years. Doppler echocardiography was a valuable tool to detect SVD, which was associated with worse clinical outcomes. Trial Registration: ClinicalTrials.gov Identifiers: NCT01240902, NCT01586910, and NCT01531374.


Assuntos
Estenose da Valva Aórtica , Implante de Prótese de Valva Cardíaca , Substituição da Valva Aórtica Transcateter , Masculino , Humanos , Idoso de 80 Anos ou mais , Feminino , Valva Aórtica/cirurgia , Resultado do Tratamento , Substituição da Valva Aórtica Transcateter/efeitos adversos
10.
Korean Circ J ; 52(10): 721-736, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-36217595

RESUMO

Aortic stenosis (AS) is one of the most common valvular heart diseases and the number of patients with AS is expected to increase globally as the older population is growing fast. Since the majority of patients are elderly, AS is no longer a simple valvular heart disease of left ventricular outflow obstruction but is accompanied by other cardiac and comorbid conditions. Because of the significant variations of the disease, identifying patients at high risk and even earlier detection of patients with AS before developing symptomatic severe AS is becoming increasingly important. With the proven of efficacy and safety of transcatheter aortic valve replacement (TAVR) in the severe AS population, there is a growing interest in applying TAVR in those with less than severe AS. A medical therapy to reduce or prevent the progression in AS is actively investigated by several randomized control trials. In this review, we will summarize the most recent findings in AS and discuss potential future management strategies of patients with AS.

11.
Molecules ; 27(15)2022 Aug 02.
Artigo em Inglês | MEDLINE | ID: mdl-35956880

RESUMO

A new ground triplet biradical 2',4',6'-triisopropylbiphenyl-3,5-diyl bis(tert-butyl nitroxide) (iPr3BPBN) was prepared and characterized by means of room-temperature ESR spectroscopy displaying a zero-field splitting pattern together with a half-field signal. Complex formation with gadolinium(III) 1,1,1,5,5,5-hexafluoropentane-2,4-dionate (hfac) afforded a macrocycle [{Gd(hfac)3(µ-iPr3BPBN)}2]. As the X-ray crystallographic analysis clarified, the biradical serves as a bridging ligand, giving a 16-membered ring, where each nitroxide radical oxygen atom is directly bonded to a Gd3+ ion. The magnetic study revealed that the iPr3BPBN bridge behaved as a practically triplet biradical and that the Gd3+-radical magnetic coupling was weakly ferromagnetic. The exchange parameters were estimated as 2jrad-rad/kB > 300 K and 2JGd-rad/kB = 1.2 K in the H = −2J S1•S2 convention. The DFT calculation based on the atomic coordinates clarified the ground triplet nature in metal-free iPr3BPBN and the enhanced triplet character upon coordination. The calculation also suggests that ferromagnetic coupling would be favorable when the Gd-O-N-C(sp2) torsion comes around 100°. The present results are compatible with the proposed magneto-structure relationship on the nitroxide-Gd compounds.


Assuntos
Gadolínio , Cristalografia por Raios X , Espectroscopia de Ressonância de Spin Eletrônica , Gadolínio/química , Íons , Modelos Moleculares
13.
JACC Cardiovasc Imaging ; 15(7): 1175-1189, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-35798393

RESUMO

BACKGROUND: The current criteria for aortic stenosis (AS) severity have not incorporated sex-related differences. OBJECTIVES: The authors investigated sex-related serial changes in left ventricular (LV) structure/function and hemodynamics in AS. METHODS: Serial echocardiograms of patients with severe AS (time 0; aortic valve area [AVA] ≤1 cm2) and ≥1 previous echocardiogram were compared between sexes. RESULTS: Of 927 patients (time 0: AVA 0.87 ± 0.11 cm2, peak velocity 4.03 ± 0.65 m/s, mean Doppler systolic pressure gradient [MG] 40.6 ± 13.1 mm Hg), 393 (42%) were women. Women had smaller body surface area (BSA) (1.77 ± 0.22 m2 vs 2.03 ± 0.20 m2; P < 0.001), lower stroke volume (SV) (81.1 ± 17.2 mL vs 88.3 ± 18.6 mL; P < 0.001), and more frequent low-gradient severe AS (n = 196 [50%] vs n = 181 [34%]; P < 0.001). Women consistently had smaller AVA, indexed AVA (AVAi), peak velocity, and MG than men. The difference in aortic valve gradient lessened when AVAi ≤0.6 cm2/m2 was applied as severe AS (n = 694, women 43%, AVA 0.95 ± 0.17 cm2, AVAi 0.50 ± 0.07 cm2/m2). Peak velocity (3.83 ± 0.66 m/s) and MG (36.5 ± 13.2 mm Hg) were lower based on AVAi severity criteria compared to those based on AVA. Men had a lower left ventricular ejection fraction (LVEF) (55.8% ± 14.8% vs 61.1% ± 11.7%; P < 0.001) and greater reduction in SV (-13.3 ± 19.6 mL vs -7.4 ± 16.4 mL; P < 0.001) as AS progressed from moderate to severe. Concentric LV hypertrophy was more common and E/e' higher in women (21.2 ± 10.9 vs 18.8 ± 9.1; P < 0.001). SV, LVEF, AVA, peak velocity, and MG became precipitously worse when AVA reached 1.2 cm2 in both sexes. CONCLUSIONS: Smaller BSA in women yields lower SV, resulting in lower aortic valve gradient than men. Indexed parameters by BSA are thus important in sex-related differences of aortic valve hemodynamics, but AVAi ≤0.6 cm2/m2 includes individuals with moderate AS. Elevated filling pressure is more common in women. Men experience a larger reduction in SV and LVEF as AS progresses. The definition of AS severity may require different criteria between sexes.


Assuntos
Estenose da Valva Aórtica , Caracteres Sexuais , Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/diagnóstico por imagem , Constrição Patológica , Feminino , Hemodinâmica , Humanos , Masculino , Valor Preditivo dos Testes , Índice de Gravidade de Doença , Volume Sistólico , Função Ventricular Esquerda , Remodelação Ventricular
14.
Inorg Chem ; 61(28): 10619-10623, 2022 Jul 18.
Artigo em Inglês | MEDLINE | ID: mdl-35775974

RESUMO

Complex formation of 5-tert-butyl-1,3-phenylene bis(tert-butyl nitroxide) and rare-earth (RE) metal ions gave a linear chain where each nitroxide O atom is directly bonded to the RE ion. The bridge was proven to be a ground triplet molecule in the complexes. A hysteresis loop was recorded below 2.8 K as a single-chain magnet for the RE = Tb derivative.

15.
Sci Rep ; 12(1): 10466, 2022 06 30.
Artigo em Inglês | MEDLINE | ID: mdl-35773436

RESUMO

Immune checkpoint blockade (ICB) treatment improves the prognosis of several types of solid tumors, however, responsiveness to ICB therapy remains low in pancreatic ductal adenocarcinoma (PDACs), which has a rich tumor microenvironment (TME). The TME is composed of various stromal cells, including cancer-associated fibroblasts (CAFs), which contribute to the establishment of an immunosuppressive microenvironment. The cyclic GMP-AMP synthase (cGAS)-stimulator of interferon genes (STING) pathway is an innate immune pathway that results in the upregulation of immune cell recruiting-cytokines and anti-tumor efficacy. In this study, we aimed to investigate the impact of cGAS-STING expression and the presence of CAFs upon immune cell infiltration in PDACs. cGAS and STING co-expressing PDAC cases showed favorable survival, with many cytotoxic CD8 + T cell infiltrations from the stromal component adjacent to the cancer cells toward cancer cells, but not in cGAS-STING signaling defected PDAC cases. The signatures of tumor-restrain CAFs were expressed in tumors with cGAS-STING signaling. Finally, transwell co-culture experiments demonstrated that immune cell infiltration was impeded by the presence of CAFs, but not by activation of cGAS-STING signaling. In conclusion, pro-infiltration signals, such as cGAS-STING, and characterization of CAFs are crucial in defeating CAF barricades and encouraging immune cell infiltration in PDACs.


Assuntos
Fibroblastos Associados a Câncer , Carcinoma Ductal Pancreático , Proteínas de Membrana , Nucleotidiltransferases , Neoplasias Pancreáticas , Fibroblastos Associados a Câncer/metabolismo , Fibroblastos Associados a Câncer/patologia , Carcinoma Ductal Pancreático/metabolismo , Carcinoma Ductal Pancreático/patologia , Humanos , Proteínas de Membrana/metabolismo , Nucleotidiltransferases/metabolismo , Neoplasias Pancreáticas/metabolismo , Neoplasias Pancreáticas/patologia , Transdução de Sinais , Microambiente Tumoral
16.
J Infect Chemother ; 28(9): 1266-1272, 2022 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-35606308

RESUMO

INTRODUCTION: Reimbursements for pharmacist interventions and infectious disease teams have recently been introduced in Japan. Arbekacin (ABK) is used to treat pneumonia and sepsis caused by methicillin-resistant Staphylococcus aureus, and therapeutic drug monitoring (TDM) is recommended. This study aimed to clarify the trend in TDM implementation for ABK over time and the factors associated with TDM implementation using a claims database. METHODS: Data of patients aged ≥15 years who received ABK for ≥3 consecutive days between 2010 and 2019 were extracted from a large Japanese medical claims database. The proportion of reimbursements claimed for TDM, pharmacist interventions, and the setup of infectious disease teams for each year were calculated. The factors associated with TDM implementation were identified using multivariate logistic regression analysis. RESULTS: The proportion of TDM implementation for ABK increased by 9.1% from 2010 to 2019, but it remained less than 40% throughout this period. The proportion of TDM implementation was higher in patients who claimed reimbursements for pharmacist interventions than in patients who did not. Logistic regression analysis showed that the stationing of pharmacists in wards and long-term ABK treatment were significantly associated with TDM implementation. CONCLUSIONS: From 2010 to 2019, the proportion of TDM implementation for ABK was significantly low. Moreover, the factors associated with TDM implementation were clarified. An environment wherein pharmacists can help implement TDM for patients receiving ABK would be beneficial.


Assuntos
Dibecacina , Staphylococcus aureus Resistente à Meticilina , Aminoglicosídeos , Antibacterianos/uso terapêutico , Dibecacina/análogos & derivados , Dibecacina/uso terapêutico , Monitoramento de Medicamentos , Humanos , Japão
17.
JACC Cardiovasc Interv ; 15(5): 511-522, 2022 03 14.
Artigo em Inglês | MEDLINE | ID: mdl-35272776

RESUMO

OBJECTIVES: The aim of this study was to compare 1-year outcomes after transcatheter aortic valve replacement (TAVR) in low surgical risk patients with bicuspid aortic stenosis to patients with tricuspid aortic stenosis. BACKGROUND: The pivotal TAVR trials excluded patients with bicuspid aortic valves. The Low Risk Bicuspid Study 30-day primary endpoint of death or disabling stroke was 1.3%. METHODS: The Low Risk Bicuspid Study is a prospective, single-arm, TAVR trial that enrolled patients from 25 U.S. sites. A screening committee confirmed bicuspid anatomy and valve classification on computed tomography using the Sievers classification. Valve sizing was by annular measurements. An independent clinical events committee adjudicated all serious adverse events, and an independent core laboratory assessed all echocardiograms. The 150 patients from the Low Risk Bicuspid Study were propensity matched to the TAVR patients in the randomized Evolut Low Risk Trial using the 1:1 5- to-1-digit greedy method, resulting in 145 pairs. RESULTS: All-cause mortality or disabling stroke at 1 year was 1.4% in the bicuspid and 2.8% in the tricuspid group (P = 0.413). A pacemaker was implanted in 16.6% of bicuspid and 17.9% of tricuspid patients (P = 0.741). The effective orifice area was similar between groups at 1 year (2.2 ± 0.7 cm2 vs 2.3 ± 0.6 cm2, P = 0.677) as was the mean gradient (8.7 ± 3.9 mm Hg vs 8.5 ± 3.1 mm Hg, P = 0.754). Fewer patients in the bicuspid group had mild or worse paravalvular leak (21.3% vs 42.6%, P < 0.001). CONCLUSIONS: There were no significant differences in clinical or forward flow hemodynamic outcomes between the propensity-matched groups at 1 year.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/etiologia , Estenose da Valva Aórtica/cirurgia , Humanos , Estudos Prospectivos , Risco , Resultado do Tratamento
18.
Int J Mol Sci ; 23(2)2022 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-35055113

RESUMO

Methionine (Met) is considered the most toxic amino acid in mammals. Here, we investigated biochemical and behavioral impacts of ad libitum one-week feeding of high-Met diets on mice. Adult male mice were fed the standard rodent diet that contained 0.44% Met (1×) or a diet containing 16 graded Met doses (1.2×-13×). High-Met diets for one-week induced a dose-dependent decrease in body weight and an increase in serum Met levels with a 2.55 mM peak (versus basal 53 µM) on the 12×Met diet. Total homocysteine (Hcy) levels were also upregulated while concentrations of other amino acids were almost maintained in serum. Similarly, levels of Met and Hcy (but not the other amino acids) were highly elevated in the cerebrospinal fluids of mice on the 10×Met diet; the Met levels were much higher than Hcy and the others. In a series of behavioral tests, mice on the 10×Met diet displayed increased anxiety and decreased traveled distances in an open-field test, increased activity to escape from water soaking and tail hanging, and normal learning/memory activity in a Y-maze test, which were reflections of negative/positive symptoms and normal cognitive function, respectively. These results indicate that high-Met ad libitum feeding even for a week can induce bipolar disorder-like disease models in mice.


Assuntos
Transtorno Bipolar/psicologia , Homocisteína/sangue , Metionina/efeitos adversos , Aminoácidos/sangue , Aminoácidos/líquido cefalorraquidiano , Animais , Transtorno Bipolar/sangue , Transtorno Bipolar/líquido cefalorraquidiano , Transtorno Bipolar/induzido quimicamente , Modelos Animais de Doenças , Esquema de Medicação , Homocisteína/líquido cefalorraquidiano , Masculino , Metionina/sangue , Metionina/líquido cefalorraquidiano , Camundongos , Teste de Campo Aberto/efeitos dos fármacos , Regulação para Cima
19.
Catheter Cardiovasc Interv ; 99(1): 171-178, 2022 01 01.
Artigo em Inglês | MEDLINE | ID: mdl-34331844

RESUMO

OBJECTIVES: The Evolut R FORWARD study confirmed safety and effectivenesss of the Evolut R THV in routine clinical practice out to 1 year. Herein, we report the final 3-year clinical follow up of the FORWARD study. BACKGROUND: Transcatheter aortic valve replacement (TAVR) is a proven alternative to surgery in elderly patients with symptomatic severe aortic stenosis. Long-term clinical outcome data with the Evolut R platform are scarce. METHODS: FORWARD is a prospective multicenter observational study that evaluated the Evolut R system in routine clinical practice at 53 centres. Eligible patients had symptomatic native aortic valve stenosis or failed surgical aortic bioprosthesis and elevated operative risk per Heart-Team assessment. TAVR was attempted in 1039 patients. RESULTS: Mean age was 81.8 ± 6.2 years, 64.9% were women, STS score was 5.5 ± 4.5% and 34.2% were frail. Rates of all-cause mortality and disabling stroke were 24.8% and 4.8% at 3 years. Early need for a new pacemaker implantation after TAVR (all-cause mortality: with new PPI; 21.0% vs. without; 22.8%, p = 0.55) and the presence of > trace paravalvular regurgitation (all-cause mortality: no or trace; 22.0% vs. ≥ mild; 25.5%, p = 0.29) did not affect survival. Between 1 and 3 years incidence rates of valve related intervention, endocarditis and clinically relevant valve thrombosis were low. CONCLUSIONS: The Evolut R valve maintained a favorable safety profile through 3 years in routine clinical practice. Rates of transcatheter heart valve-related adverse events were low.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Feminino , Humanos , Estudos Prospectivos , Desenho de Prótese , Fatores de Risco , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
20.
Europace ; 24(5): 835-844, 2022 05 03.
Artigo em Inglês | MEDLINE | ID: mdl-34734227

RESUMO

AIMS: To evaluate the benefit of speckle tracking radial strain imaging (STRSI)-guided left ventricular (LV) lead (LVL) positioning in cardiac resynchronization therapy (CRT) in patients (pts) with ischaemic cardiomyopathy with CRT indication. METHODS AND RESULTS: We conducted a prospective randomized controlled trial. Patients were enrolled in nine centres with 2:1 randomization into two groups (guided vs. control). Patients underwent STRSI to identify the optimal LV position from six LV segments at midventricular level. Implantation via STRSI was attempted for recommended segment in the guided group only. Follow-up included echocardiography (6 months) and clinical evaluation (6 and 12 months). The primary endpoint was comparison % reduction in LV end-systolic volume at 6 months with baseline. Secondary endpoints included hospitalizations for heart failure and death, and improvement in additional echocardiographic measurements and quality of life score. A total of 172 patients (115 guided vs. 57 control) were enrolled. In the guided group, 60% of the implanted LV leads were adjudicated to be successfully located at the recommended segment, whereas in the control group 44% reached the best STRSI determined segment. There was no difference between the groups in any of the primary or secondary endpoints at 6 and 12 months. CONCLUSION: Our findings suggest that echo-guided implantation of an LV lead using STRSI does not improve the clinical or echocardiographic response compared with conventional implantation.


Assuntos
Terapia de Ressincronização Cardíaca , Cardiomiopatias , Insuficiência Cardíaca , Isquemia Miocárdica , Terapia de Ressincronização Cardíaca/efeitos adversos , Terapia de Ressincronização Cardíaca/métodos , Dispositivos de Terapia de Ressincronização Cardíaca , Cardiomiopatias/diagnóstico por imagem , Cardiomiopatias/terapia , Insuficiência Cardíaca/diagnóstico por imagem , Insuficiência Cardíaca/terapia , Ventrículos do Coração , Humanos , Isquemia Miocárdica/complicações , Isquemia Miocárdica/diagnóstico por imagem , Isquemia Miocárdica/terapia , Estudos Prospectivos , Qualidade de Vida , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...