Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Radiol Phys Technol ; 8(1): 125-34, 2015 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-25404493

RESUMO

The applicability of the activation of an NaI scintillator for neutron monitoring at a clinical linac was investigated experimentally. Thermal neutron fluence rates are derived by measurement of the I-128 activity generated in an NaI scintillator irradiated by neutrons; ß-rays from I-128 are detected efficiently by the NaI scintillator. In order to verify the validity of this method for neutron measurement, we irradiated an NaI scintillator at a research reactor, and the neutron fluence rate was estimated. The method was then applied to neutron measurement at a 10-MV linac (Varian Clinac 21EX), and the neutron fluence rate was estimated at the isocenter and at 30 cm from the isocenter. When the scintillator was irradiated directly by high-energy X-rays, the production of I-126 was observed due to photo-nuclear reactions, in addition to the generation of I-128 and Na-24. From the results obtained by these measurements, it was found that the neutron measurement by activation of an NaI scintillator has a great advantage in estimates of a low neutron fluence rate by use of a quick measurement following a short-time irradiation. Also, the future application of this method to quasi real-time monitoring of neutrons during patient treatments at a radiotherapy facility is discussed, as well as the method of evaluation of the neutron dose.


Assuntos
Nêutrons , Fótons , Radioterapia de Alta Energia/instrumentação , Contagem de Cintilação/instrumentação , Contagem de Cintilação/métodos , Iodeto de Sódio/química , Humanos , Método de Monte Carlo , Aceleradores de Partículas , Doses de Radiação , Radioterapia de Alta Energia/métodos , Raios X
2.
Mutat Res ; 696(2): 107-13, 2010 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-20064627

RESUMO

Morphology and function (secretion of thyroid hormone) of human thyroid tissues from Graves' disease patients are well maintained in C57BL/6J-scid mice. Serum level of thyroid hormone was reduced by fission neutrons from the nuclear reactor UTR-KINKI, and changes in thyroid hormone by fission neutrons were bigger than those by low LET radiations, X-rays and (137)Cs gamma-rays, suggesting high relative biological effectiveness (RBE; 6.5) of fission neutrons. Microarray analyses revealed that about 3% of genes showed more than 4-fold change in gene expression in the unexposed thyroid tissues against surgically resected thyroid tissues from the same patient, probably due to the difficult oxygen and nutrient supply shortly after transplantation. Dose-dependent changes in gene expression against unexposed concurrent controls were observed with increasing doses of fission neutrons (0.2-0.6Gy) and (137)Cs gamma-rays (1.0-3.0Gy) and showed high RBE (4.2). Furthermore, there were some specific genes which showed more than 4-fold change in gene expression in all the thyroid tissues exposed to higher doses of radiation, especially neutrons (0.4 and 0.6Gy), but none at lower doses (0.2Gy of neutrons and 1.0 and 2.0Gy of gamma-rays). These genes related to degeneration, regeneration, apoptosis, and transcription, respond specifically and very sensitively to neutron injury in human thyroid tissues. This is the first experimental report that fission neutrons can induce some morphological and functional disorders in human tissues, showing high RBE against gamma-ray exposure. These results are useful to evaluate the risks of fission neutrons and cosmic rays to humans.


Assuntos
Nêutrons/efeitos adversos , Fissão Nuclear , Glândula Tireoide/efeitos da radiação , Animais , Relação Dose-Resposta à Radiação , Raios gama/efeitos adversos , Expressão Gênica/efeitos da radiação , Humanos , Camundongos , Camundongos SCID , Eficiência Biológica Relativa , Glândula Tireoide/transplante , Hormônios Tireóideos/sangue , Hormônios Tireóideos/efeitos da radiação , Transplante Heterólogo
3.
J Radiat Res ; 50(1): 83-7, 2009 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-19218783

RESUMO

Microdosimetry study has been carried out at the education and research mini-reactor of Kinki University (UTR-KINKI) using a tissue equivalent gas proportional counter (TEPC). The microdosimetric single event spectra for 0.5, 1, 2, 3 and 5 microm site sizes were obtained in the lineal energy range from 1 to 1000 keV/microm. Neutron and gamma-ray fractional doses were estimated from the single event spectra. The neutron dose fraction was varied from 35 to 55% for 0.5 to 5 microm site size. The averaged lineal energy, y(D), for each site size was likewise estimated and found to be dependent on the site size. The averaged lineal energy for neutron was slightly larger than that of the fission neutrons from (252)Cf, and the averaged lineal energy for gamma-ray had similar site-size-dependence of 25 keV gamma-rays and 250 kV X-rays. Relative biological effectiveness was found to be 4.1 +/- 0.13 for UTR-KINKI using Tilikidis's 2 Gy-response function. The estimated RBE for UTR-KINKI neutrons is quite close to the previous biological experimental value of 4.3 +/- 0.6 for micronucleated cells in gill cell of Medaka and 4.6 +/- 0.5 for induction of lymphocyte apoptosis in the thymus of ICR mice.


Assuntos
Biologia/instrumentação , Técnicas de Cultura de Células/instrumentação , Medicina Nuclear/educação , Reatores Nucleares , Radiometria/instrumentação , Pesquisa/instrumentação , Técnicas de Cultura de Tecidos/instrumentação , Desenho de Equipamento , Análise de Falha de Equipamento , Miniaturização , Radiometria/métodos , Técnicas de Cultura de Tecidos/métodos
4.
Transfusion ; 49(3): 585-95, 2009 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-19192255

RESUMO

BACKGROUND: The aim was to considerably enhance the sensitivity of hepatitis B virus (HBV) surface antigen (HBsAg) detection and investigate whether the window period for HBV detection could be reduced. STUDY DESIGN AND METHODS: A high-sensitivity chemiluminescent enzyme immunoassay (CLEIA) was developed for quantitative HBsAg detection by a combination of monoclonal antibodies, each one for a specific epitope of HBsAg, and by improving the conjugation technique. The sensitivity of the assay was compared with that of the existing chemiluminescent immunoassay (CLIA). Commercially available seroconversion panels and samples of HBV-infected chimpanzees were tested with the developed prototype to assess whether the window period for HBsAg detection could be reduced to that for DNA detection. RESULTS: Compared to the existing CLIA, the CLEIA prototype detected HBsAg with approximately 230-fold higher sensitivity and showed a reduced window period. HBsAg detection by the CLEIA prototype and HBV DNA detection by polymerase chain reaction (PCR) occurred simultaneously. The mean time for the CLEIA prototype to first detect HBsAg was approximately 17.4 days less than that for the existing systems. Further, CLEIA prototype enabled HBsAg detection even in anti-HBs-positive seroconversion samples. In the inoculated chimpanzees the HBsAg and HBV DNA became detectable simultaneously and concentrations increased in parallel, whereas HBsAg remained detectable longer than HBV DNA in the declining phase of viremia. CONCLUSION: The CLEIA prototype yielded results comparable with those of HBV DNA PCR. This novel high-sensitivity assay may be useful for early detection of HBV infection and monitoring patients with a history of infection.


Assuntos
DNA Viral/genética , Antígenos de Superfície da Hepatite B/genética , Antígenos de Superfície da Hepatite B/imunologia , Hepatite B/imunologia , Hepatite B/virologia , Imunoensaio/métodos , Animais , DNA Viral/metabolismo , Hepatite B/metabolismo , Antígenos de Superfície da Hepatite B/metabolismo , Técnicas de Diluição do Indicador , Camundongos , Camundongos Endogâmicos BALB C , Modelos Biológicos , Pan troglodytes , Especificidade por Substrato , Fatores de Tempo
5.
Appl Radiat Isot ; 65(9): 1037-40, 2007 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-17566749

RESUMO

A dosimetry study of mice irradiation at the Kinki University nuclear reactor (UTR-KINKI) has been carried out. Neutron and gamma-ray doses at the irradiation port in the presence of 0, 1, 2, 4 and 6 mice were measured using the paired chamber method. The results show that neutron dose is reduced with increasing numbers of mice. In the six-mice irradiation condition, neutron dose is about 15% smaller compared to a case where no mice were placed in the irradiation port. To investigate the distortion of the neutron spectrum during mice irradiation at UTR-KINKI, a Monte Carlo calculation using the MCNP4C code has been carried out. The measured variation in dose with respect to the total mouse mass was closely reproduced by the calculation results for neutron and gamma-ray dose. Distortion of the neutron spectrum was observed to occur between 1 keV and 1 MeV.


Assuntos
Nêutrons , Reatores Nucleares , Animais , Camundongos , Dosagem Radioterapêutica
7.
J Radiat Res ; 43(4): 381-6, 2002 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-12674202

RESUMO

The energy spectrum of fission neutrons in the biological irradiation field of the Kinki University reactor, UTR-KINKI, has been determined by a multi-foil activation analysis coupled with artificial neural network techniques and a Au-foil activation method. The mean neutron energy was estimated to be 1.26 +/- 0.05 MeV from the experimentally determined spectrum. Based on this energy value and other information, the neutron dose rate was estimated to be 19.7 +/- 1.4 cGy/hr. Since this dose rate agrees with that measured by a pair of ionizing chambers (21.4 cGy/hr), we conclude that the mean neutron energy could be estimated with reasonable accuracy in the irradiation field of UTR-KINKI.


Assuntos
Nêutrons , Reatores Nucleares , Radiometria , Japão , Fissão Nuclear
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...