RESUMO
The simultaneous multielement determination of Pb, Sn, Ni and Cu in aluminium alloys by electrothermal atomic absorption spectrometry (ETAAS) was performed by a quick method using slurry sampling. The metallic colloidal slurries were obtained by an electrical discharge operated in liquid medium. In this work, the effects of aluminium were evaluated and the results show that it causes a strong retention of Pb, Ni and Cu at low pyrolysis temperatures which is overcome by employing high pyrolysis temperatures. Aluminium also significantly improves the thermal stabilisation of Pb and Sn, it being possible to reach pyrolysis temperatures of 1100 and 1300 degrees C, respectively. Such stabilisation indicates that the performance of aluminium as a matrix modifier for Pb is better than that obtained using phosphate and magnesium nitrate without substantial changes of the figures of merit. The effects of aluminium on the atomisation characteristics of the elements and those coming from the simultaneous multielement determination on the figures of merit of the elements are also discussed. In this work, a calibration procedure involving a matrix matching method with aqueous aluminium standards is proposed as a simple and efficient way to solve the inconveniences originated by the aluminium matrix. The proposed method was applied to the simultaneous multielement determination of several aluminium-base alloy standards giving results well within the recommended values.
RESUMO
Se determinó, el contenido de Zn, Cu, Fe, Ca, P y Mg en leche temprana en 72 madres de la ciudad de Caracas. Las muestras fueron colectadas durante tres etapas de lactación: calostro (3 días), transicional (7 días) madura (21 días). Los cambios más marcados en las concentraciones de los elementos estudiados se observan principalmente durante las primeras semanas de lactación, tendiendo a estabilizarse hacia la tercera semana de lactación. El contenido de Zn, Cu, Fe, Ca, P y Mg en leche calostro, fue de 7,1 ñ 2,5 µg/ml, 0,52 ñ 0.15 µg/ml, 0,49 ñ 0,14 µg/ml, 214 ñ 62 µg/ml, 107 ñ 27 µg/ml y 33,3 ñ 5,5 µg/ml. En leche transicional 4,0 ñ 1,0 µg/ml, 0,5 ñ 0,10 µg/ml, 0,38 ñ µg/ml, 292 ñ 62 µg/ml, 213 ñ 36 µg/ml y 30,4 ñ 5,2 µg/ml y en leche madura 2,8 ñ 2,7 µg/ml, 0,47 ñ 0,08 µg/ml, 0,36 ñ 0,09 µg/ml, 224 ñ 49 µg/ml, 175 ñ 35 µg/ml y 25,2 ñ 3,3 µg/ml. Las concentraciones de los elementos traza estudiados (Zn, Fe, Cu) se mantienen dentro de los niveles considerados normales. Los valores de los elementos mayoritarios (Ca, P, Mg) son comparables a los reportados en la bibliografía para otros países. Estos resultados sugieren que el estado nutricional de esta población de madres es adecuado, para satisfacer las demandas del lactante en las primeras etapas de su vida
Assuntos
Humanos , Masculino , Feminino , Pré-Escolar , Cálcio/uso terapêutico , Cobre/uso terapêutico , Fósforo/farmacologia , Ferro/administração & dosagem , Ferro/classificação , Magnésio/administração & dosagem , Magnésio/classificação , Zincum Metallicum/uso terapêuticoRESUMO
Se ha reportado distintos datos sobre oligoelementos, debido a diferencias geográficas, raciales y nutricionales, de allí la importancia de conocer los valores de cada país. En 91 gestantes de un Hospital de Caracas y sus recién nacidos en el momento del parto se les tomó sangre venosa y del cordón umbilical respectivamente. El zinc (Zn) y cobre (Cu) en plasma se obtuvo por espectrofotometría de absorción atómica (varían modelo AA-875) y los parámetros maternos del neonato se correlacionaron. Las madres pertenecían a los estratos III-IV-V de Graffar. El Zn materno fue: Parto: 93,12 ug/dl ñ 22,41 ug/dl y puerperio: 93,24 ug/dl ñ 16,13 ug/dl. Cu materno parto: 304,59 ug/dl ñ 66,25 ug/dl y puerperio: 290,06 ug/dl ñ 47,16 ug/dl. Zn en cordón 131,07 ug/dl ñ 8,00 ugdl y el puerperio fue más bajo Cu en el puerperio 82,88 ug/dl ñ 22,20 ug/dl y en el puerperio aumentó a 108,27 ug/dl. Dieciseis RN presentaron Cu bajo (< 70 ug/dl). La correlación fue negativa entre Zn materno y semanas de gestación (primer cuartil)y entre concentración de Cu (primer cuartil) en sangre del cordón, peso y talla de los neonatos