Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Vestn Khir Im I I Grek ; 163(5): 14-9, 2004.
Artigo em Russo | MEDLINE | ID: mdl-15651688

RESUMO

The work presents results of comparative investigations of the integral hydrodynamic characteristics of the best for today domestic mechanical heart valve (MHV) Medinzh-2 (MI-2) and the turn-disk domestic MHV--LIKS-2, EMIKS (E) and foreign MHV--Medtronic-Hall, Bjork-Shiley (BS), Sorin (SO) and bicuspid valves--St. Jude Medical (SJ), Carbomedics in the stationary and in the pulsatile flows. It was found that according to the main hydrodynamic characteristics including the outlet flow structure, MHV MI-2 was substantially superior to MHV E, BS and SO, and by certain characteristics it approximated to the best foreign MHV SJ. Like all mechanical heart valves, the valve MI-2 disturbs the uniformity of the inlet flow and forms a complex non-stationary flow with detached zones, areas of great shear stresses, with vortex structures of different types, and hence the task of hydrodynamic optimization of its construction is thought to become actual. The comparison of clinical parameters of work of the valve MI-2 with its hydrodynamic characteristics confirms its high hemodynamic effectiveness and thrombo-resistance in patients at long-term periods of follow-up, taking into account the adequate correction of disbalance of hemostasis.


Assuntos
Próteses Valvulares Cardíacas , Valva Mitral , Hemorreologia , Modelos Cardiovasculares
2.
Vestn Khir Im I I Grek ; 163(5): 25-30, 2004.
Artigo em Russo | MEDLINE | ID: mdl-15651690

RESUMO

A comparative investigation of biomechanical and hydrodynamic characteristics of stentless and stented bioprostheses was carried out. It was demonstrated that stentless bioprostheses are functionally superior to stented ones. The differences between biomechanics and hydrodynamics of the examined stentless bioprostheses "BioLab", "AB-Mono-Kemerovo" and DD2 and stented bioprostheses "Wessex", "KemCor" and "Bionox-2" were shown.


Assuntos
Valva Aórtica , Bioprótese , Próteses Valvulares Cardíacas , Stents , Hemorreologia , Maleabilidade
3.
Vestn Khir Im I I Grek ; 160(5): 45-51, 2001.
Artigo em Russo | MEDLINE | ID: mdl-11836999

RESUMO

A comparative analysis of experiments with biomechanics and hydrodynamic stentless xenografts implanted into the subcoronary position with completely (n = 7) and partially (n = 7) scalloped sinuses was made. The implantation was performed into the human aortic root complexes in vitro. Factors of the influence on biomechanical and hydrodynamic performances of xenografts before and after implantation have been established. Subcoronary implantation of stentless bioprostheses with the completely scalloped sinuses proved to result in better flow and biomechanical characteristics than the implantation technique with the saved noncoronary sinus.


Assuntos
Valva Aórtica , Bioprótese , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Animais , Fenômenos Biomecânicos , Humanos , Desenho de Prótese , Suínos , Transplante Heterólogo
4.
Vestn Khir Im I I Grek ; 159(4): 20-5, 2000.
Artigo em Russo | MEDLINE | ID: mdl-11011396

RESUMO

A comparative analysis of geometrical, biomechanical and hydrodynamic characteristics of the valve-aortic complexes taken from humans of different age has shown a determining role of distensibility of the aortic root in the functioning of valve cusps. An alteration of geometrical relationships of elements of the aortic root, its less distensibility, worse biomechanical and hydrodynamic characteristics of the aortic valve in humans older than 50-60 years of age is established.


Assuntos
Aorta Torácica/fisiologia , Valva Aórtica/fisiologia , Adulto , Fatores Etários , Idoso , Fenômenos Biomecânicos , Hemodinâmica , Humanos , Pessoa de Meia-Idade , Fatores de Tempo
5.
Vestn Khir Im I I Grek ; 157(1): 10-6, 1998.
Artigo em Russo | MEDLINE | ID: mdl-9611307

RESUMO

The use of an original device developed by the authors which was introduced in the blood flow in experiments in dogs has confirmed the presence of coiled blood flow in different parts of the aorta. The rate, direction and angle of coiling were calculated. The results obtained suggest that the fact of coiling the blood flow should be taken into account when constructing new models of artificial valves of the heart in order to decrease the energy value of the cardiac output, to prevent injury of the formed elements of blood and thrombogenesis.


Assuntos
Aorta/fisiologia , Próteses Valvulares Cardíacas , Função Ventricular Esquerda/fisiologia , Animais , Velocidade do Fluxo Sanguíneo , Débito Cardíaco , Cães , Próteses Valvulares Cardíacas/efeitos adversos , Modelos Biológicos , Desenho de Prótese , Fluxo Sanguíneo Regional , Trombose/prevenção & controle
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...