Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 68
Filtrar
1.
Ann Pharmacother ; 35(4): 409-13, 2001 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-11302401

RESUMO

OBJECTIVE: To describe the serum concentrations of continuous infusion of cefuroxime for postsurgical prophylaxis of sternal wound infection in patients undergoing coronary artery bypass graft (CABG), and to assess the incidence of sternal wound infection in this population. METHODS: This was a prospective, noncomparative trial involving 54 patients undergoing elective CABG surgery. All patients enrolled in the study received cefuroxime 1.5 g as a single intravenous dose 30 minutes preoperatively, followed by a continuous infusion of 3 g every 24 hours until removal of all central venous catheters. RESULTS: Of the 53 evaluable patients, the mean steady-state cefuroxime serum concentration was 21.6 +/- 14.2 microg/mL (range 6.56-59.5). No patient developed a sternal wound infection. The mean treatment duration was 2.58 +/- 2.13 days (range 1-13). The median hospital and intensive care unit lengths of stay were six days and 46 hours, respectively. The average antibiotic cost per day was $32.76. CONCLUSIONS: These preliminary results of continuous infusion of cefuroxime 3 g/d for prophylaxis of sternal wound infections in CABG patients indicate that serum concentrations are highly variable, but reliably above the minimum inhibitory concentration for the common anticipated pathogens in this setting. Further comparative trials in a larger number of patients are necessary before this mode of administration can be routinely advocated for prophylaxis.


Assuntos
Cefuroxima/sangue , Cefalosporinas/sangue , Ponte de Artéria Coronária , Adulto , Idoso , Idoso de 80 Anos ou mais , Cefuroxima/administração & dosagem , Cefuroxima/economia , Cefalosporinas/administração & dosagem , Cefalosporinas/economia , Feminino , Humanos , Infusões Intravenosas , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Infecção da Ferida Cirúrgica/economia , Infecção da Ferida Cirúrgica/epidemiologia , Infecção da Ferida Cirúrgica/prevenção & controle
2.
J Trauma ; 41(3): 558-60, 1996 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-8810985

RESUMO

Massive organized pericardial hematoma secondary to blunt trauma is extremely rare. We report a case of a 69-year-old man referred with refractory ascites who was found to have a 10 x 6 x 8 cm organized pericardial hematoma with hemodynamic characteristics consistent with constrictive pericarditis. The cause was attributed to blunt chest trauma associated with a fall 3 years previously. Excision of the mass and removal of the constricting epicardium relieved his symptomatology. A review of the literature is included.


Assuntos
Cardiopatias/complicações , Hematoma/complicações , Pericardite Constritiva/etiologia , Pericárdio , Acidentes por Quedas , Idoso , Cardiopatias/diagnóstico por imagem , Cardiopatias/etiologia , Hematoma/diagnóstico por imagem , Hematoma/etiologia , Hemodinâmica , Humanos , Masculino , Pericardite Constritiva/diagnóstico por imagem , Pericárdio/diagnóstico por imagem , Radiografia , Ferimentos não Penetrantes/complicações
4.
Clin Nurs Res ; 4(1): 22-37, 1995 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-7703873

RESUMO

Thermodilution cardiac output and cardiac index (CI) require inserting a pulmonary artery catheter, an invasive device associated with many iatrogenic complications. The purpose of this study was to establish the concurrent validity of two noninvasive measures of CI (skin temperature and limb blood flow) by determining their correlation with invasive CI. Twenty-one subjects undergoing coronary artery bypass grafting (CABG) were studied every 2 hours for 8 hours in the immediate postoperative period. Neither limb blood flow (LBF) nor skin temperature at five sites correlated significantly (p < .05) with CI at all five data collection times. Ankle temperature and LBF were significantly correlated with CI at one data collection time. On the basis of the findings of this study, neither skin temperature nor LBF can be used as a noninvasive predictor of CI in the immediate postoperative period following CABG.


Assuntos
Velocidade do Fluxo Sanguíneo , Débito Cardíaco , Extremidades/irrigação sanguínea , Temperatura Cutânea , Adulto , Idoso , Pesquisa em Enfermagem Clínica , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Termodiluição
5.
Heart Lung ; 22(2): 112-20, 1993.
Artigo em Inglês | MEDLINE | ID: mdl-8449754

RESUMO

OBJECTIVE: To determine the relationship between the mixed venous oxygen saturation (SvO2) and the cardiac index (CI) in individuals during the first 8 hours after coronary artery bypass grafting. DESIGN: Descriptive with a correlational design. SETTING: Cardiac intensive care unit at a university medical center in the midwestern United States. SUBJECTS: Twenty-one subjects (16 men and 5 women) undergoing coronary artery bypass grafting. OUTCOME MEASURES: SvO2, thermodilution cardiac output and CI measured every 2 hours during the first 8 hours after surgery. INTERVENTION: Elective coronary artery bypass grafting. RESULTS: Significant (p < 0.05) but moderate correlations between SvO2 and CI were found only at 6 and 8 hours after surgery (r = 0.66, p = 0.001; r = 0.44, p = 0.47). Secondary analysis determined that in subjects without lung disease, mixed venous oxygen tension (PvO2) had significant correlation with CI at all data collection times (r = 0.54 to 0.72; p = 0.003 to 0.02). CONCLUSIONS: The results of this study indicate that immediately after coronary artery bypass grafting, SvO2 cannot reliably predict CI. Although statistically significant results were found for the correlation between PvO2 and CI at all data collection times, the correlations were too low to support the use of the PvO2 as a reliable clinical predictor of CI without further study.


Assuntos
Gasometria/normas , Débito Cardíaco , Ponte de Artéria Coronária/enfermagem , Monitorização Fisiológica/normas , Adulto , Idoso , Superfície Corporal , Pesquisa em Enfermagem Clínica , Cuidados Críticos , Feminino , Hemoglobinas/análise , Humanos , Masculino , Pessoa de Meia-Idade , Monitorização Fisiológica/instrumentação , Monitorização Fisiológica/métodos , Consumo de Oxigênio , Período Pós-Operatório , Valor Preditivo dos Testes , Termodiluição , Fatores de Tempo
6.
J Cardiovasc Surg (Torino) ; 32(2): 250-8, 1991.
Artigo em Inglês | MEDLINE | ID: mdl-2019630

RESUMO

The purpose of this study was to evaluate left ventricular (LV) diastolic mechanical properties after induced global ischemia using reliable new methods. The diastolic function of nonoxygenated crystalloid solution (CC sO2) was compared with those of oxygenated crystalloid (CC cO2) and oxygenated fluorocarbon cardioplegic (FC cO2) solutions. Postischemic ventricular performance was studied in 3 equal (no. 7) groups of dogs subjected to 120 minutes of global ischemia induced at an average myocardial temperature of 18.5 +/- 1.4 degrees C. LV diastolic function (chamber and myocardial stiffness) and relaxation (the exponential fall in LV pressure) were evaluated by sonomicrometry and Millar micrometers before ischemia and at 45 and 60 minutes after ischemia. LV chamber and myocardial stiffness in the CC sO2 group was significantly (p less than 0.05) elevated after ischemia, while the CC cO2 and FC cO2 groups did not show increases in LV chamber and myocardial stiffness after ischemia. LV relaxation before and after ischemia was not changed in any group. The myocardial water content of the CC sO2 group was significantly higher than that of the CC cO2 and FC cO2 groups (p less than 0.05). We conclude that (1) the postischemic increase in LV chamber stiffness in the CC sO2 group was dependent not only on the increase in intrinsic myocardial stiffness but also due to an increase in myocardial edema, and (2) there was no correlation between the LV relaxation rate and the leftward shift of diastolic compliance curves in the CC sO2 group.


Assuntos
Soluções Cardioplégicas/farmacologia , Fluorocarbonos/farmacologia , Isquemia/fisiopatologia , Compostos de Potássio , Função Ventricular Esquerda/efeitos dos fármacos , Animais , Soluções Cardioplégicas/química , Diástole/efeitos dos fármacos , Cães , Combinação de Medicamentos , Fluorocarbonos/química , Coração/efeitos dos fármacos , Coração/fisiopatologia , Parada Cardíaca Induzida , Derivados de Hidroxietil Amido , Oxigênio/análise , Potássio/química , Potássio/farmacologia , Função Ventricular Esquerda/fisiologia
7.
J Thorac Cardiovasc Surg ; 100(3): 353-7; discussion 357-9, 1990 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-2104516

RESUMO

Over the 3-year period from Jan. 1, 1986, through Dec. 31, 1988, we have implanted 101 automatic implantable cardioverter-defibrillators into patients with life-threatening ventricular arrhythmias. There were 82 male patients and 19 female patients. The mean age was 58 years with a range of 25 to 82 years. The indication for implantation was ventricular fibrillation in 89 patients and recurrent ventricular tachycardia in 12 patients. Seventy-seven patients had a history of prior myocardial infarction or coronary artery disease, or both. Eighteen patients had nonischemic cardiomyopathy. One patient had a prolonged QT syndrome and five patients had no evidence of preexisting structural heart disease. The mean injection fraction was 37% +/- 17%. Forty-one of the automatic implantable cardioverter-defibrillator implantations were associated with procedures necessitating cardiopulmonary bypass. The hospital mortality rate was 4% and the morbidity rate was 15%. The only statistical difference between those patients who did and did not have postoperative complications was a history of a prior myocardial infarction (90% versus 54%, p less than 0.05). Twenty percent of patients had new-onset postoperative atrial fibrillation after implantation of the device. Eleven percent of patients had sustained ventricular tachycardia postoperatively. Although there was a trend toward a higher complication/death rate in the patients whose automatic implantable cardioverter-defibrillator was inserted in association with cardiopulmonary bypass (24% versus 15%) and the occurrence of new-onset postoperative atrial fibrillation (27% versus 15%), these findings were not statistically significant. Automatic implantable cardioverter-defibrillator implantation with and without concomitant cardiopulmonary bypass is associated with a clinically important morbidity and mortality rate and development of postoperative arrhythmias.


Assuntos
Cardioversão Elétrica , Próteses e Implantes , Taquicardia/mortalidade , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Morbidade , Taquicardia/cirurgia , Taquicardia/terapia
8.
Tohoku J Exp Med ; 161(3): 185-97, 1990 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-2247890

RESUMO

The purpose of this experiment was to compare myocardial protective effect after global ischemia using oxygenated crystalloid (CCcO2) and an oxygenated blood (BCcO2) cardioplegic solutions. Post-ischemic ventricular performance was studied in 2 equal (n = 7) groups of dogs subjected to 120 min of global ischemia induced at average myocardial temperatures of 8 degrees C in the CCcO2 group and 18 degrees C in the BCcO2 group. Left ventricular (LV) function included analysis of LV systolic function (global and regional function), LV diastolic function (chamber and myocardial stiffness) and LV relaxation was measured by sonomicrometry and Millar micrometers. Data were processed with a Dec PDP-11/23 computer. In vitro oxygen content (Vol%) measured 3.2 +/- 1.0 (CCcO2) and 9.5 +/- 0.3 (BCcO2). Percent recoveries of LV global function (LVSP, loop area, % shortening, LV dp/dt, mean VCF and E max) in the CCcO2 group were approximately the same as those in the BCcO2 group. There were no significant differences in LV regional function (loop area and % shortening) after ischemia between the two groups. The chamber and myocardial stiffness after ischemia in the CCcO2 group were almost the same as the baseline values. Values in the BCcO2 group were reduced significantly compared to the baseline level. There were significant differences in post-ischemic chamber and myocardial stiffness between the two groups. Post-ischemic maximum negative LV dp/dt in both groups decreased significantly compared to the baseline values. However, the time constant and diastolic interval after ischemia in both groups were approximately the same as the baseline values. We conclude that there were no significant differences in myocardial protective effect between the CCcO2 and BCcO2 groups, and both methods preserved the ischemic myocardium well.


Assuntos
Soluções Cardioplégicas/farmacologia , Doença das Coronárias/fisiopatologia , Coração/efeitos dos fármacos , Substitutos do Plasma/farmacologia , Animais , Pressão Sanguínea/efeitos dos fármacos , Soluções Cristaloides , Cães , Cardioversão Elétrica , Eletrocardiografia , Coração/fisiologia , Ventrículos do Coração/efeitos dos fármacos , Ventrículos do Coração/fisiopatologia , Hemodinâmica/efeitos dos fármacos , Técnicas In Vitro , Soluções Isotônicas , Temperatura , Preservação de Tecido
9.
Circulation ; 81(4): 1252-9, 1990 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-2317907

RESUMO

A consistently effective transvenous defibrillation system for use in automatic defibrillators could significantly alter the approach to patients at risk of sudden death. Transvenous defibrillation systems that use a right ventricular (RV) electrode only or an RV electrode in combination with a chest patch are relatively inefficient at applying current to the posterolateral left ventricle. An RV electrode combined with a coronary sinus (CS) electrode, however, may improve current distribution to the posterolateral left ventricle. The purpose of this investigation, therefore, was to evaluate the effectiveness and safety of a specially designed transvenous lead system with a CS electrode capable of current delivery to this relatively inaccessible region of the heart. In 20 survivors of cardiac arrest, we determined defibrillation efficacy immediately before defibrillator surgery for monophasic pulses delivered between an RV catheter electrode and a CS catheter electrode system and compared these findings with an RV catheter electrode-thoracic patch defibrillation system. Subsequently, we referenced the efficacy of both transvenous systems to an epicardial patch electrode system at the time of defibrillator implantation. The mean delivered-energy defibrillation threshold for the CS-RV electrode system was 17.5 +/- 7.9 J, which was substantially lower than the RV electrode-thoracic patch system (25.6 +/- 11.4 J, p = 0.0016 [46% more]). Defibrillation threshold voltage was 529 +/- 123 V for the CS-RV electrode system and 647 +/- 164 V (22% more) for the RV electrode-thoracic patch system (p = 0.0013).(ABSTRACT TRUNCATED AT 250 WORDS)


Assuntos
Vasos Coronários , Cardioversão Elétrica/métodos , Limiar Diferencial , Cardioversão Elétrica/instrumentação , Cardioversão Elétrica/normas , Eletrodos , Estudos de Avaliação como Assunto , Feminino , Cardiopatias/terapia , Humanos , Masculino , Pessoa de Meia-Idade , Veias
10.
Am J Physiol ; 257(5 Pt 2): H1534-42, 1989 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-2589508

RESUMO

Multiple paired lesions produced by a train of high-voltage low-charge rectangular pulses (20 A, 30 microsecond) and a train of low-voltage high-charge rectangular pulses (2 A, 300 microsecond) were made to the left ventricular epicardium of 23 dogs to determine the relative influence of voltage and charge delivery on injury of canine myocardium. Both pulsing methods contained equal amounts of energy (15 J) delivered over equal periods of time (100 ms), and both pulsing methods were nonarcing and therefore nonbarotraumatic. The volume of cardiac tissue injury resulting from both types of pulses was then evaluated from planimetered serial histological sections after 1, 10, and 30 days. Over the 30-day period, lesion size progressively decreased to 56% of its original value for the high-voltage low-charge pulse. In contrast, lesion size from the low-voltage high-charge pulse remained relatively constant, decreasing only 12% of its original value. These results indicate that when energy delivery is held constant, voltage, not charge, is the dominant mediator of cell injury. Also, cells subjected to high voltages appear to recover partially over time with significantly less constancy of tissue injury than that seen with low-voltage high-charge pulses.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Eletricidade , Eletrocirurgia , Miocárdio/patologia , Animais , Cães , Eletrocirurgia/métodos , Fatores de Tempo
11.
J Thorac Cardiovasc Surg ; 98(5 Pt 1): 774-82, 1989 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-2811413

RESUMO

To assess the severity and duration of new organic brain dysfunction after cardiac operations, we used an extensive battery of neuropsychologic tests to evaluate 65 patients undergoing coronary artery bypass grafting and 25 patients undergoing intracardiac operations with cardiopulmonary bypass. Patients were tested the day before the operation, before discharge from the hospital, and approximately 7 months later. Compared to 47 nonsurgical control subjects tested at comparable time intervals, surgical subjects showed generalized impairment of neuropsychologic abilities near the time of discharge from the hospital. At follow-up testing, there was no evidence of residual impairment among the surgically treated patients as a whole. In fact, they showed greater improvement compared to initial test scores than did control subjects. However, performance of 10 patients (11%) declined on half of the neuropsychologic variables between preoperative and follow-up testing. Neurobehavioral outcome was not related to the type of operation (coronary bypass versus intracardiac), to factors of cardiopulmonary bypass (duration, aortic occlusion time, hypotension, arterial carbon dioxide tension, minimum hematocrit value, minimum temperature). The only predictor of negative outcome was advanced age. We conclude that, although neurobehavioral impairment is common during hospitalization after cardiac operations, the prognosis for eventual full recovery is favorable, although less so among the elderly.


Assuntos
Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Ponte de Artéria Coronária/efeitos adversos , Transtornos Neurocognitivos/etiologia , Ansiedade/etiologia , Ponte Cardiopulmonar , Depressão/etiologia , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Transtornos Neurocognitivos/diagnóstico , Testes Neuropsicológicos , Estudos Prospectivos
12.
J Am Coll Cardiol ; 14(3): 728-33, 1989 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-2768721

RESUMO

Biphasic waveforms have been suggested as a superior waveform for ventricular defibrillation. To test this premise, a prospective randomized intraoperative evaluation of defibrillation efficacy of monophasic and biphasic waveform pulses was performed in 22 survivors of out of hospital ventricular fibrillation who were undergoing cardiac surgery for implantation of an automatic defibrillator. The initial waveform used in a patient for defibrillation testing, either monophasic or biphasic, was randomly selected. Subsequently, each patient served as his or her own control for defibrillation testing of the other waveform. The defibrillation threshold was defined as the lowest pulse amplitude that would effectively terminate ventricular fibrillation with a single discharge delivered 10 s after initiation of an episode of ventricular fibrillation induced with alternating current. Each defibrillation pulse was recorded oscilloscopically, and defibrillation pulse voltage, current, resistance and stored energy were measured. Fifteen (68%) of the 22 patients had a lower defibrillation threshold with the biphasic pulse, 3 (14%) had a lower threshold with the monophasic pulse and 4 (18%) had equal defibrillation thresholds (within 1.0 J) regardless of waveform. The mean leading edge defibrillation threshold voltage was 317 +/- 105 V when the monophasic pulse was used and 267 +/- 102 V (16% less) when the biphasic pulse was used (p = 0.008). Mean leading edge defibrillation threshold current was 7.9 +/- 3.7 A when the monophasic pulse was used and 6.8 +/- 3.8 A (14% less) when the biphasic pulse was used (p = 0.051).(ABSTRACT TRUNCATED AT 250 WORDS)


Assuntos
Cardioversão Elétrica/métodos , Fibrilação Ventricular/terapia , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Distribuição Aleatória
13.
J Am Coll Cardiol ; 14(1): 165-71, 1989 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-2738261

RESUMO

Sixteen out-of-hospital survivors of ventricular fibrillation underwent a prospective, randomized, intraoperative comparison of sequential pulse and single pulse defibrillation with use of two distinct electrode systems and waveform shapes currently available for clinical use. Defibrillation was tested alternately with either the single pulse or the sequential pulse system 10 s into an episode of ventricular fibrillation. Sequential pulse defibrillation was performed with two 4 ms truncated exponential pulses of constant duration delivered to three equally spaced oval epicardial patch electrodes composed of concentric coils. The posterior left ventricular electrode served as the common cathode. The first anode was over the anterior right ventricle and the second anode was over the anterior left ventricle. Single pulse defibrillation was performed with the standard intracardiac defibrillation system with use of a single truncated exponential pulse with a fixed 65% tilt delivered across two rectangular, wire mesh epicardial patch electrodes positioned over the anterior right ventricle and posterolateral left ventricle. During defibrillation threshold determination, voltage and current waveforms were recorded and used to determine pulsing resistance and delivered and stored energy. Average defibrillation threshold leading edge voltage for the single pulse technique was 273 +/- 101 V compared with 246 +/- 67 V (11% less) for the sequential pulse technique (p = 0.136). Defibrillation threshold leading edge current for the single pulse technique was 6.7 +/- 2.5 A compared with 5.2 +/- 1.7 A (29% less) for the sequential pulse method (p = 0.005). The defibrillation threshold delivered energy was 5.6 +/- 4.0 J for the single pulse technique and 3.5 +/- 1.8 J (38% less) for the sequential pulse technique (p = 0.021).(ABSTRACT TRUNCATED AT 250 WORDS)


Assuntos
Cardioversão Elétrica/métodos , Fibrilação Ventricular/terapia , Adulto , Idoso , Condutividade Elétrica , Cardioversão Elétrica/instrumentação , Eletrodos , Estudos de Avaliação como Assunto , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Distribuição Aleatória
14.
J Thorac Cardiovasc Surg ; 98(1): 63-71; discussion 71-2, 1989 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-2739427

RESUMO

Atrioventricular node reentry tachycardia is a common type of supraventricular tachycardia. Rarely is it incapacitating and refractory to drug therapy, but when it is, the only option in therapy until recently has been atrioventricular node ablation or antitachycardia pacemaker insertion. The purpose of this paper is to review the case histories of four patients in whom we have surgically abolished atrioventricular node reentrant tachycardia while intentionally preserving atrioventricular node conduction. All four patients had atrioventricular node reentrant tachycardia confirmed by electrophysiologic study as diagnosed by established criteria. One patient had a left posterior atrioventricular accessory pathway, in addition to atrioventricular node reentrant tachycardia. All patients underwent intraoperative epicardial and endocardial mapping. Direct surgical dissection of the atrioventricular node node was performed in all four patients during normothermic cardiopulmonary bypass. Early and late postoperative electrophysiologic studies were used to evaluate the success of the surgical dissection. None of the patients had any evidence of dual atrioventricular node pathways or spontaneous or inducible atrioventricular node reentrant tachycardia postoperatively. At last follow-up (15 weeks to 21 months postoperatively), all patients were free from arrhythmias and cardiac medications, all were in normal sinus rhythm, and all had a subjectively improved life-style. This technique of direct surgical dissection of the atrioventricular node during normothermic cardiopulmonary bypass has allowed for complete cure of atrioventricular node reentrant tachycardia, while maintaining normal atrioventricular node function in these four patients.


Assuntos
Taquicardia por Reentrada no Nó Atrioventricular/cirurgia , Taquicardia Supraventricular/cirurgia , Adulto , Eletrocardiografia , Eletrofisiologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Prognóstico , Taquicardia por Reentrada no Nó Atrioventricular/fisiopatologia
15.
Circulation ; 79(6 Pt 2): I73-8, 1989 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-2785879

RESUMO

Seven hundred ninety-three patients had coronary artery bypass graft (CABG) surgery within 30 days after acute myocardial infarction (AMI) between August 1982 and July 1987. Hospital mortality was 5.7%. Age, surgical priority, prior CABG surgery, congestive heart failure (CHF), and type of AMI were associated with increased hospital mortality by logistic regression analysis of nine independent variables. When the analysis was carried out separately for men and women, the same predictive variables were identified for men, but only surgical priority and age were predictive of operative mortality for women. Elective CABG surgery can be carried out at low risk following AMI in stable patients regardless of the interval between AMI and surgery. Patients who undergo urgent or emergency surgery and those who have CHF, Q wave infarction, or a history of prior AMI are at increased risk.


Assuntos
Ponte de Artéria Coronária , Infarto do Miocárdio/cirurgia , Adulto , Idoso , Idoso de 80 Anos ou mais , Ponte de Artéria Coronária/mortalidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Análise de Regressão , Fatores de Risco , Fatores de Tempo
16.
J Am Coll Cardiol ; 13(6): 1362-6, 1989 May.
Artigo em Inglês | MEDLINE | ID: mdl-2703617

RESUMO

The effect of ventricular fibrillation duration in humans on defibrillation efficacy as it pertains to the time of intervention of an automatic implantable defibrillator is unknown. If a difference in defibrillation efficacy exists in the early period after ventricular fibrillation onset, it may affect algorithms used by antiarrhythmic devices for arrhythmia detection and therapy. Therefore, a prospective, randomized evaluation was performed of the effect of ventricular fibrillation durations of 10 s and 20 s on defibrillation thresholds in 10 survivors of sudden cardiac arrest undergoing implantation of an automatic cardioverter defibrillator. The initial duration of ventricular fibrillation was chosen randomly. Subsequently, each patient served as his or her own control for the alternate duration of ventricular fibrillation to that chosen initially. The mean leading edge defibrillation threshold voltage was 411 +/- 114 V when ventricular fibrillation persisted for 10 s and 419 +/- 125 V when it persisted for 20 s (p = 0.73). The mean defibrillation threshold current was 11.4 +/- 2.8 A when ventricular fibrillation persisted for 10 s and 11.4 +/- 3.2 A when it persisted for 20 s (p = 0.97). The delivered energy defibrillation threshold was 11.5 +/- 5.9 J when ventricular fibrillation persisted for 10 s and 12.0 +/- 6.9 J when it persisted for 20 s (p = 0.67). These findings show that the defibrillation threshold does not change between 10 and 20 s of ventricular fibrillation in out-of-hospital survivors of cardiac arrest at the time of surgical implantation of an automatic defibrillator. The data may have influence on the programming of defibrillator detection algorithms.


Assuntos
Cardioversão Elétrica/instrumentação , Fibrilação Ventricular/terapia , Algoritmos , Cardioversão Elétrica/métodos , Eletrodos Implantados , Feminino , Humanos , Cuidados Intraoperatórios , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Distribuição Aleatória , Fatores de Tempo
17.
Am J Cardiol ; 63(7): 433-7, 1989 Feb 15.
Artigo em Inglês | MEDLINE | ID: mdl-2916427

RESUMO

The effect of electrode polarity on defibrillation thresholds in humans is unknown. This prospective, randomized evaluation of electrode polarity on defibrillation thresholds was performed in 21 survivors of ventricular fibrillation (VF) undergoing cardiac surgery. Defibrillation was always performed with 2 identical large rectangular, wire mesh electrodes positioned over the anterior wall of the right ventricle and the posterolateral wall of the left ventricle. The initial electrode polarity for the left ventricular (LV) electrode was chosen randomly for determination of the defibrillation threshold. Subsequently, electrode polarity was reversed. The defibrillation threshold was defined as the lowest pulse amplitude that would effectively terminate VF with a single discharge delivered 10 seconds after initiation of an episode of VF with alternating current. For each defibrillation pulse, voltage, current, resistance and delivered energy were recorded. Of the 21 patients, 15 (71%) had a lower defibrillation threshold when the LV electrode was positive, 2 patients (10%) had a lower defibrillation threshold when the LV electrode was negative and 4 patients (19%) had equal defibrillation thresholds (within 0.5 J) regardless of polarity. The mean leading edge defibrillation threshold voltage was 370 +/- 88 volts when the LV electrode was negative and 320 +/- 109 volts (14% less) when the LV electrode was positive (p = 0.014). Mean leading edge defibrillation threshold current was 9.3 +/- 3.1 amps when the LV electrode was negative compared to 7.7 +/- 3.1 amps (17% less) when the LV electrode was positive (p = 0.0033). There were no differences in resistance with the 2 configurations.(ABSTRACT TRUNCATED AT 250 WORDS)


Assuntos
Cardioversão Elétrica/instrumentação , Adulto , Idoso , Condutividade Elétrica , Eletrodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Fibrilação Ventricular/terapia
18.
Am J Cardiol ; 62(10 Pt 1): 718-22, 1988 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-3421171

RESUMO

The effect of initially ineffective defibrillation pulses on subsequent defibrillation success is not known. Therefore, the voltage, current and energy at the defibrillation threshold were compared with the defibrillation rescue pulse voltage, current and energy that terminated ventricular fibrillation when an ineffective pulse just below the defibrillation threshold had been used initially. This lower amplitude ineffective pulse was termed a "subdefibrillation threshold" pulse. The pulse that restored sinus rhythm after the subdefibrillation threshold pulse was delivered was termed the "subdefibrillation threshold rescue pulse." This comparison was undertaken, intraoperatively, in 14 out-of-hospital cardiac arrest survivors using a sequential-pulse catheter-patch defibrillation system. Each of the 14 patients required higher voltage, current, delivered energy and stored energy for defibrillation with the subdefibrillation threshold rescue pulse than with the defibrillation threshold pulse. The defibrillation threshold voltage was 451 +/- 127 volts compared with a subdefibrillation threshold rescue voltage of 585 +/- 147 volts (p less than 0.00002). The defibrillation threshold current was 5.5 +/- 2.4 amps compared with a subdefibrillation threshold rescue current of 7.2 +/- 2.7 amps (p less than 0.00001). Delivered and stored energies were 10.9 +/- 7.4 and 12.3 +/- 7.2J, respectively, for the defibrillation threshold pulse and were 17.6 +/- 9.4 J (p less than 0.00002) and 20.5 +/- 9.3 J (p less than 0.00005), respectively, for the subdefibrillation threshold rescue pulse. It is concluded that the risk of requiring considerably higher energies than anticipated for defibrillation must be incurred, should defibrillation fail because of an initially insufficient defibrillation pulse.(ABSTRACT TRUNCATED AT 250 WORDS)


Assuntos
Cardioversão Elétrica/efeitos adversos , Parada Cardíaca/fisiopatologia , Fibrilação Ventricular/fisiopatologia , Adulto , Idoso , Cardioversão Elétrica/métodos , Estudos de Avaliação como Assunto , Feminino , Parada Cardíaca/terapia , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Fibrilação Ventricular/terapia
20.
Circ Res ; 63(2): 409-14, 1988 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-3396159

RESUMO

Voltage waveform breakdown is characteristic of barotraumatic shock-wave generation during electrical catheter ablation of cardiac arrhythmias. The purpose of this investigation was to avoid barotrauma by defining, in vitro, the limits of pulse amplitude and pulse width for rectangular constant-current pulses that do not result in voltage breakdown and subsequently to determine what pulsing frequency is safe for use when high-energy trains of pulses are used. Electric pulses were delivered with a variable waveform modulator with a wide dynamic range and bandwidth capable of delivering pulses of 30-10,000-mu sec duration with amplitudes of up to 25 A. Cathodal pulses were delivered to a 6F catheter immersed in fresh anticoagulated bovine blood warmed to 37 degrees C to stimulate the milieu of a catheter in the chambers of the human heart. The maximum pulse amplitude that could be delivered without incurring voltage waveform breakdown varied inversely with pulse duration. Pulses of 30 mu sec broke down at currents above 24 A (2,500 V). Pulses of 10,000-mu sec duration broke down at 1 A (250 V). The maximum safely delivered energy for a single pulse was 2.5 J for pulses of 80-120 mu sec. Peak power for single pulses was maximum at 50-55 kW with 30-50-mu sec pulses. Charge delivery for single pulses was maximized at 9 mC with long, 10,000-mu sec duration pulses. To deliver an electrical pulse with energy significantly greater than 2.5 J without incurring voltage breakdown, trains of pulses were delivered where each pulse in the train had previously been shown to be free of voltage breakdown.(ABSTRACT TRUNCATED AT 250 WORDS)


Assuntos
Cateterismo Cardíaco , Cardioversão Elétrica/métodos , Animais , Bovinos/sangue , Eletricidade , Fenômenos Físicos , Física
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...