1.
Yakugaku Zasshi ; 134(1): 119-25, 2014.
Artigo em Japonês | MEDLINE | ID: mdl-24389624

RESUMO

A method for the simple and reliable determination of triazolam and midazolam in human plasma using gas chromatography with microelectron capture detection has been developed. Samples (0.5 mL of plasma) were prepared using a simple solvent extraction with 3% isoamyl alcohol/benzene in the presence of NaOH. Two microlitres of the extract were injected onto the capillary column ((5%-phenyl)-methylpolysiloxane). The method was found to be valid in terms of selectivity, linearity, precision, accuracy, and recovery over the concentration range of 0.2 to 20 ng/mL for triazolam, and from 0.5 to 200 ng/mL for midazolam, respectively. Intra- and inter-day precisions determined at three concentrations were from 4.1 to 9.3% for triazolam and from 2.9 to 13.0% for midazolam. The accuracies were within 17.7% for triazolam and within 13.0% for midazolam. This proposed method was successfully applied to a pharmacokinetic study of triazolam or midazolam in healthy volunteers.


Assuntos
Cromatografia Gasosa/métodos , Midazolam/sangue , Triazolam/sangue , Elétrons , Humanos , Solventes/química
2.
Artigo em Inglês | MEDLINE | ID: mdl-22889991

RESUMO

A new method of analysis has been developed and validated for the determination of plasma celiprolol concentration. Plasma samples (1 ml) were pre-purified by solid-phase extraction with Bond Elut C18. The separation was achieved with XBridge C18 column (150 mm × 3.0mm i.d., 3.5 µm) at 35 °C using a mixture of acetonitrile and 10mM ammonium acetate buffer (pH 10.5) (34:66, v/v) under isocratic conditions at a flow rate of 0.4 ml/min. The peak was detected using a fluorescence detector at excitation 250 nm and emission 482 nm. Retention times for the internal standard (acebutolol) and celiprolol were 4.2 min and 6.3 min, respectively. Calibration curves were linear over the range of 1.0-1000 ng/ml (r>0.999), with a limit of quantification at 1.0 ng/ml. Intra- and inter-assay precision (relative standard deviation) were less than 13.3% and the accuracy (relative error) was -5.1% to 11.5% at four different concentrations. This proposed method was successfully applied to a study of pharmacokinetic interactions between celiprolol and apple juice in humans.


Assuntos
Celiprolol/sangue , Cromatografia Líquida de Alta Pressão/métodos , Espectrometria de Fluorescência/métodos , Área Sob a Curva , Bebidas , Celiprolol/química , Celiprolol/farmacocinética , Estabilidade de Medicamentos , Frutas , Interações Ervas-Drogas , Humanos , Modelos Lineares , Malus , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Extração em Fase Sólida/métodos