Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Health Phys ; 105(5 Suppl 3): S199-208, 2013 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-24077079

RESUMO

University of Pittsburgh Medical Center (UPMC) installed an Emergency Department Notification System (EDNS) in one of its hospitals. The system, manufactured by Thermo Fisher Scientific (Thermo Fisher Scientific, Inc., 81 Wyman Street, Waltham, MA 02454), consists of four NaI(Tl) scintillation detectors, a 2.5 L PVT gamma counter, a 512 channels multi-channel analyzer, a system controller, and a database-monitoring server. We evaluated a portable Interceptor Interceptor™ hand-held detector (Thermo Fisher Scientific, Inc., 81 Wyman Street, Waltham, MA 02454) as part of the system for potential ambulancebased early detection and warning unit. We present the minimum detectable activity, distance, and isotope identification success rates along with the change in detector response to various radioisotope sources placed in a Rando® humanoid phantom. (The Phantom Laboratory. P.O. Box 511, Salem, NY 12865-0511 USA). The present paper reports these results.


Assuntos
Monitoramento de Radiação/métodos , Liberação Nociva de Radioativos , Centros Médicos Acadêmicos/organização & administração , Emergências , Humanos , Pennsylvania , Monitoramento de Radiação/instrumentação , Radioisótopos/análise , Radiometria
2.
Health Phys ; 100 Suppl 2: S71-8, 2011 May.
Artigo em Inglês | MEDLINE | ID: mdl-21451311

RESUMO

Recently, University of Pittsburgh Medical Center (UPMC) Cancer Centers has installed an Emergency Department Notification System (EDNS) in one of its hospitals. This system, manufactured by Thermo Fisher Scientific (Thermo Fisher Scientific, Inc., 81 Wyman Street, Waltham, MA 02454), was designed to discriminate non-medical radioactive isotopes from medical radioactive isotopes routinely used in nuclear medicine and radiation treatments. It is modular in nature and consists of four NaI(Tl) scintillation detectors, a 512 channels multi-channel analyzer, a system controller, and a database-monitoring server. A series of tests were carried out to evaluate the performance characteristics of this system using a variety of radioactive sources of varying activities. These included measurements of minimum detectable activity, detector response distance to various source activities, detector response to different speeds of a moving radioisotope, and single and multiple radioisotope identification and classification. Measured results show that the system is capable of identifying radioactive sources of nominal activity 0.13 MBq (3.5 µCi) and higher in a relatively short period of time (<11.1 s). The database-monitoring server could send an alarm signal to appropriate personnel when the analysis of the results indicated the presence of a non-medical or threat radioisotope. The present paper reports these results.


Assuntos
Hospitais , Proteção Radiológica/instrumentação , Proteção Radiológica/métodos , Radioisótopos/efeitos adversos , Radioisótopos/análise , Serviço Hospitalar de Emergência , Física Médica , Humanos , Incidentes com Feridos em Massa , Pennsylvania , Proteção Radiológica/estatística & dados numéricos , Radioisótopos/classificação , Radiometria/instrumentação , Radiometria/estatística & dados numéricos , Terrorismo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...