1.
J Trauma Acute Care Surg ; 95(5): 672-678, 2023 11 01.
Artigo em Inglês | MEDLINE | ID: mdl-37478341

RESUMO

BACKGROUND: Uncontrolled hemorrhage is the leading cause of preventable death in combat and civilian trauma. Efficacious hemostatic agents in junctional hemorrhage can quell blood loss and improve survival. We hypothesized that a novel hemostatic foam of starch and chitosan would improve hemostasis, and thereby increase survival in a swine femoral artery hemorrhage model when compared with CombatGauze (CG). METHODS: A novel hemostatic foam of starch and chitosan was created and modified during the study period. Thirty pigs (four excluded) were assigned to treatment using either foam version 1 (FV1, n = 9) or 2 (FV2, n = 8), or (n = 9) in a standard swine femoral artery hemorrhage model. Animals were observed for 150 minutes. Outcomes assessed included hemostasis, survival, posttreatment blood loss, IV fluid volume, and hemodynamic and laboratory trends. RESULTS: Hemostasis prior to 150 minutes was similar with 44.4%, 77.8%, and 50% of swine treated with CG, FV1 and FV2, respectively (Kaplan-Meyer and log-rank test [KM-LR] p > 0.05). Survival to 150 minutes was improved in swine treated with FV1 (100%) compared with CG (55.6%) (KM-LR p = 0.02). Survival was similar between FV1 and FV2 (75%) (KM-LR p > 0.05), and between CG and FV2 (KM-LR p > 0.05). Using mixed model for longitudinal data, mean arterial pressure decreased significantly in CG- and FV2-treated swine, while there was no significant change in mean arterial pressure in FV1-treated swine. Trends in lactic acid, hematocrit, platelets, INR, and thrombelastography were more favorable for FV1 compared with CG. CONCLUSION: In this preclinical study of junctional hemorrhage, survival was improved in swine treated with version 1 of a novel chitosan/starch foam compared with CG. Trends in hemodynamics and laboratory data were also more favorable in the FV1-treated swine. This novel hemostatic foam may be an effective alternative to current hemostatic agents.


Assuntos
Quitosana , Hemostáticos , Suínos , Animais , Hemostáticos/farmacologia , Hemostáticos/uso terapêutico , Artéria Femoral/lesões , Polieletrólitos , Hemorragia/etiologia , Hemostasia , Amido
2.
ASAIO J ; 68(6): 791-799, 2022 06 01.
Artigo em Inglês | MEDLINE | ID: mdl-34860709

RESUMO

Current generation continuous flow assist devices to operate at a fixed speed, which limits preload response and exercise capacity in left ventricular assist device (LVAD) patients. A feedback control system was developed to automatically adjust pump speed based on direct measurements of ventricular loading using a custom cannula tip with an integrated pressure sensor and volume-sensing conductance electrodes. The input to the control system is the integral of the left ventricular (LV) pressure versus conductance loop (PGA) over each cardiac cycle. The feedback control system adjusts pump speed based on the difference between the measured PGA and the desired PGA. The control system and cannula tip were tested in acute ovine studies (n = 5) using the HeartMate II LVAD. The preload response of the control system was evaluated by partially occluding and releasing the inferior vena cava using a vessel loop snare. The cannula tip was integrated onto a custom centrifugal flow LVAD and tested in a 14-day bovine study. The control system adjusted pump support to maintain constant ventricular loading: pump speed increased (decreased) following an increase (decrease) in preload. This study demonstrated in vivo the Starling-like response of an automatic pump control system based on direct measurements of LV loading.


Assuntos
Coração Auxiliar , Animais , Bovinos , Humanos , Cânula , Ventrículos do Coração , Ovinos , Pressão Ventricular
3.
ASAIO J ; 67(11): 1240-1249, 2021 11 01.
Artigo em Inglês | MEDLINE | ID: mdl-33883510

RESUMO

We have miniaturized and optimized our implantable rotary blood pump developed to provide long-term mechanical right heart support for patients who have failing Fontan circulation. The objective of this study was to evaluate the miniaturized Fontan circulation assist device (mini-FCAD) during 30-day sheep studies (n = 5). A complete right heart bypass was performed and all return flow was supported by the pump. Postoperatively, unfractionated heparin was given to maintain thromboelastography R times of 2× normal. The first two studies were terminated on day 0 and day 4 due to complications. In the final three studies, the animals remained healthy and were electively terminated at 30 ± 2 days. Pump flow was between 5 and 7 lpm, left atrial pressure remained normal, and inlet pressures were between 3 and 18 mm Hg with no incidents of suction. There was no evidence of hemolysis, end organ or pulmonary dysfunction, thromboembolic events, nor thermal damage to the surrounding tissue. Explanted devices from two studies were free of thrombi and in the third study there were unattached thrombi on the SVC inlet of the rotor. The mini-FCAD was successfully tested in vivo as a right heart replacement device demonstrating adequate circulatory support and normal physiologic pulmonary and venous pressures.


Assuntos
Técnica de Fontan , Derivação Cardíaca Direita , Coração Auxiliar , Animais , Técnica de Fontan/efeitos adversos , Coração Auxiliar/efeitos adversos , Hemodinâmica , Heparina , Humanos , Ovinos
4.
Res Vet Sci ; 132: 257-261, 2020 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-32688102

RESUMO

The purpose of this study was to determine the level of agreement between invasive and noninvasive blood pressure measurements in anesthetized, non-surgically manipulated Dorset cross-bred lambs. Twelve healthy female Dorset cross-bred lambs, weighing 37.3 ± 7.4 kg (mean ± SD) underwent isoflurane anesthesia for simultaneous measurement of systolic arterial pressure (SAP), mean arterial pressure (MAP) and diastolic arterial pressure (DAP) from an invasive blood pressure source and a noninvasive oscillometric source (O-NIBP). The femoral artery was catheterized for invasive blood pressure measurements, while noninvasive blood pressure was measured from a cuff placed on the antebrachium. The Bland-Altman method was used to calculate agreement between SAP, MAP and DAP measurements. The bias ± SD between SAP, MAP and DAP measurements was 3.6 ± 12.0, 4.9 ± 9.1 mmHg and 4.1 ± 8.0, respectively. The 95% limits of agreement for SAP, MAP and DAP were - 19.9 to 27.1, -13.0 to 22.8 mmHg, and - 11.7 to 19.9, respectively. Overall, agreement was poor between femoral IBP and O-NIBP monitoring techniques in anesthetized Dorset cross-bred lambs, with O-NIBP underestimating the femoral IBP. Arterial blood pressure should be most accurately measured using an invasive blood pressure monitoring technique in lambs undergoing isoflurane anesthesia.


Assuntos
Monitores de Pressão Arterial/veterinária , Pressão Sanguínea/fisiologia , Ovinos/fisiologia , Anestesia/veterinária , Animais , Determinação da Pressão Arterial/veterinária , Feminino , Isoflurano , Oscilometria/veterinária
5.
Vet Anaesth Analg ; 46(2): 209-213, 2019 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-30744953

RESUMO

OBJECTIVE: To determine the degree of agreement between arterial and venous blood gases in anesthetized lambs using a point-of-care analyzer. STUDY DESIGN: Prospective experimental study. ANIMALS: A group of 12 female Dorset cross-bred lambs, weighing 37.3 ± 7.4 kg (mean ± standard deviation). METHODS: Lambs were anesthetized with isoflurane for catheterization of the jugular vein and femoral artery, and blood samples were collected simultaneously for analysis of pH, PCO2, PO2, base excess (BE), bicarbonate ( [Formula: see text] ), total carbon dioxide (tCO2), oxygen saturation (SO2), ionized calcium (iCa) and potassium (K+) using the Vet Scan i-STAT handheld analyzer. The Bland-Altman method was used to calculate agreement between arterial and venous measurements. RESULTS: Strong agreement was identified between arterial and venous pH (bias = 0.04; 95% limits of agreement = 0.02-0.06), K+ (bias = -0.1 and 95% limits of agreement = -0.8 to 0.5) and iCa (bias = 0.04; 95% limits of agreement = -0.08 to 0.0003). There was poor agreement for PO2 (bias = 168.0; 95% limits of agreement = 77.4-258.7) and SO2 (bias = 9.1; 95% limits of agreement = 2.8-15.3), as these values were higher in arterial blood than in venous blood. Moderate agreement was present for BE (bias = 1.7; 95% limits of agreement = -2.7 to 6.1), PCO2 (bias = -2.1; 95% limits of agreement = -7.5 to 3.4), [Formula: see text] (bias = 1.1; 95% limits of agreement = -3.1 to 5.3) and tCO2 (bias = 1.0; 95% limits of agreement = -3.3 to 5.3). CONCLUSIONS AND CLINICAL RELEVANCE: Venous blood can be used for the measurement of pH, K+ and iCa in anesthetized Dorset cross-bred lambs. Arterial blood is required for accurate measurement of PO2, SO2, PCO2, [Formula: see text] , tCO2 and BE to assess systemic blood oxygenation and pulmonary function in anesthetized Dorset cross-bred lambs.


Assuntos
Anestesia Geral/veterinária , Gasometria/veterinária , Sistemas Automatizados de Assistência Junto ao Leito , Ovinos/fisiologia , Animais , Animais Recém-Nascidos/sangue , Animais Recém-Nascidos/fisiologia , Dióxido de Carbono/sangue , Feminino , Estudos Prospectivos , Sensibilidade e Especificidade , Ovinos/sangue
6.
ASAIO J ; 65(4): 371-379, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-30681440

RESUMO

Mechanical circulatory support for children under 6 years of age remains a challenge. This article describes the preclinical status and the results of recent animal testing with the Penn State Infant Left Ventricular Assist Device (VAD). The objectives have been to 1) demonstrate acceptably low thromboembolic risk to support Food and Drug Administration approval, 2) challenge the device by using minimal to no anticoagulation in order to identify any design or manufacturing weaknesses, and 3) improve our understanding of device thrombogenicity in the ovine animal model, using multicomponent measurements of the coagulation system and renal ischemia quantification, in order to better correlate animal results with human results.The Infant VAD was implanted as a left VAD (LVAD) in 18-29 kg lambs. Twelve LVAD and five surgical sham animals were electively terminated after approximately 30 or 60 days. Anticoagulation was by unfractionated heparin targeting thromboelastography R times of 2x normal (n = 6) or 1x normal (n = 6) resulting in negligible heparin activity as measured by anti-Xa assay (<0.1 IU/ml). Platelet inhibitors were not used.There were no clinically evident strokes or evidence of end organ dysfunction in any of the 12 electively terminated LVAD studies. The degree of renal ischemic lesions in device animals was not significantly different than that found in five surgical sham studies, demonstrating minimal device thromboembolism.In summary, these results in a challenging animal test protocol support the conclusion that the Penn State Infant VAD has a low thromboembolic risk and may allow lower levels of anticoagulation.


Assuntos
Insuficiência Cardíaca/cirurgia , Coração Auxiliar/efeitos adversos , Tromboembolia/prevenção & controle , Animais , Anticoagulantes/uso terapêutico , Coagulação Sanguínea , Desenho de Equipamento , Feminino , Insuficiência Cardíaca/complicações , Heparina , Humanos , Lactente , Masculino , Modelos Animais , Ovinos , Carneiro Doméstico
7.
J Invest Surg ; 32(8): 706-715, 2019 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-29641275

RESUMO

Purpose/Aim: In prey species, such as sheep, clinical signs of postoperative pain can manifest in subtle ways or may be concealed entirely. Previous publications describing pain assessment in ruminants focus on lameness and flock behavior, often in a farm environment. These indicators of pain may be difficult to assess in sheep housed in biomedical research settings. We have developed a novel pain scoring system for sheep undergoing thoracotomy for implantation of ventricular assist devices that are permanently housed in modified stanchions. Materials and Methods: The pain scoring system includes ruminant-specific behavioral signs of pain in addition to objective measurements that can be readily evaluated in a biomedical research setting. A numerical score is generated by the evaluator for each category. A decision tree is utilized to help guide further action following the generation of a cumulative score by the evaluator. A total score of 0-2 requires no intervention, 3-9 requires the consideration of additional analgesic administration, and a pain score ≥ 10 warrants the consideration of additional multimodal analgesia. Results: A novel pain scoring system and decision tree specifically designed for sheep undergoing thoracotomy in a biomedical research environment was developed and successfully utilized. Out of 102 postoperative pain scores measured, 86 scores were <2. There were 17/102 postoperative pain scores ≥3, which typically resulted in the administration of supplemental rescue analgesia in the immediate postoperative period. Conclusions: A novel pain scoring system was developed and utilized in a biomedical research environment for evaluating postoperative pain in sheep undergoing thoracotomy for implantation of a ventricular assist device. Further studies are necessary to validate the reliability of this novel pain scoring system.


Assuntos
Técnicas de Observação do Comportamento/métodos , Medição da Dor/métodos , Dor Pós-Operatória/diagnóstico , Implantação de Prótese/efeitos adversos , Toracotomia/efeitos adversos , Animais , Comportamento Animal/fisiologia , Árvores de Decisões , Modelos Animais de Doenças , Coração Auxiliar , Humanos , Dor Pós-Operatória/etiologia , Dor Pós-Operatória/fisiopatologia , Reprodutibilidade dos Testes , Ovinos
8.
ASAIO J ; 65(4): 318-323, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-29757760

RESUMO

The lack of direct measurement of left ventricular unloading is a significant impediment to the development of an automatic speed control system for continuous-flow left ventricular assist devices (cf-LVADs). We have developed an inlet cannula tip for cf-LVADs with integrated electrodes for volume sensing based on conductance. Four platinum-iridium ring electrodes were installed into grooves on a cannula body constructed from polyetheretherketone (PEEK). A sinusoidal current excitation waveform (250 µA pk-pk, 50 kHz) was applied across one pair of electrodes, and the conductance-dependent voltage was sensed across the second pair of electrodes. The conductance catheter was tested in an acute ovine model (n = 3) in conjunction with the HeartMate II rotary blood pump to provide circulatory support and unload the ventricle. Echocardiography was used to measure ventricular size during pump support for verification for the conductance measurements. The conductance measurements correlated linearly with the echocardiography dimension measurements more than the full range of pump support from minimum support to suction. This cannula tip will enable the development of automatic control systems to optimize pump support based on a real-time measurement of ventricular size.


Assuntos
Cânula , Eletrodos Implantados , Ventrículos do Coração/fisiopatologia , Coração Auxiliar , Animais , Desenho de Equipamento , Ovinos
9.
ASAIO J ; 65(6): 593-600, 2019 08.
Artigo em Inglês | MEDLINE | ID: mdl-30299303

RESUMO

An implantable rotary blood pump was developed to provide long-term mechanical right heart support for patients who have failing Fontan circulation. The objective of this study was to evaluate the pump in vivo in a 30 day sheep study. Pump speed was set at 3,900 rpm for the duration of the study, and pump power was between 4.3 and 4.6 W. The pump inlet pressures for the superior vena cava (SVC) and inferior vena cava (IVC) were 14 ± 15 and 11 ± 15 mm Hg, respectively, over the duration of the study. Hematocrit remained stable at 30% ± 4%. Partial thromboplastin time (PTT) steadily increased from 30 s preoperatively to a high of 59 s on postoperative day 20, while prothrombin time (PT) remained at 20 ± 2 s for the duration of the study. The implantation and postoperative recovery were successful, and the animal demonstrated normal physiologic pulmonary and venous pressures and cardiac output. On pump inspection, the IVC and SVC inlets were completely clear of any deposits, but there were small thrombi (approximately 0.5 mm diameter) between each of the three rotor blades and along 20% of the parting line of the two volute halves. A complete right heart bypass was performed, postoperative recovery was successful, and the pump demonstrated adequate circulatory support and normal physiologic pulmonary and venous pressures. This study was the first successful test of a right heart replacement device in a chronic animal study.


Assuntos
Técnica de Fontan , Derivação Cardíaca Direita/métodos , Animais , Circulação Assistida , Técnica de Fontan/instrumentação , Derivação Cardíaca Direita/instrumentação , Hemodinâmica/fisiologia , Masculino , Ovinos , Veia Cava Inferior/fisiopatologia , Veia Cava Superior/fisiopatologia
10.
J Am Assoc Lab Anim Sci ; 58(1): 21-29, 2019 01 01.
Artigo em Inglês | MEDLINE | ID: mdl-30538007

RESUMO

Urinary biomarkers are used increasingly for sensitive prediction of kidney injury in preclinical and clinical studies. Given the frequent requirement of anesthesia in various animal models of disease, it is important to define the effects of anesthesia on kidney injury biomarkers to guide the appropriate selection of anesthetic agents and to avoid potential confounders in the interpretation of data. Therefore, we performed a prospective study using male C57BL/6J mice (n = 45) exposed to a single anesthetic episode to determine the effects several common anesthesia regimens on the urinary excretion of 2 commonly used kidney injury biomarkers: hepatitis A virus cellular receptor 1 (HAVCR1, also known as KIM1) and lipocalin 2 (LCN2, also known as NGAL). We evaluated 3 injectable regimens (ketamine-xylazine, tiletamine-zolazepam, and pentobarbital) and 2 inhalational agents (isoflurane and sevoflurane). Concentrations of HAVCR1 and LCN2 in urine collected at various time points after anesthesia were measured by using ELISA. Administration of ketamine-xylazine resulted in a significant increase in HAVCR1 levels at 6 h after anesthesia but a decrease in LCN2 levels compared with baseline. LCN2 levels steadily increased over the first 24 h after inhalant anesthesia, with a significant increase at 24 h after sevoflurane. These results suggest that injectable anesthesia had early effects on HAVCR1 and LCN2 levels, whereas inhalational agents increased these biomarkers over prolonged time.


Assuntos
Anestesia Geral/veterinária , Anestésicos/administração & dosagem , Receptor Celular 1 do Vírus da Hepatite A/metabolismo , Lipocalina-2/urina , Anestesia Geral/efeitos adversos , Anestésicos/efeitos adversos , Animais , Biomarcadores/urina , Regulação da Expressão Gênica/efeitos dos fármacos , Rim/efeitos dos fármacos , Ciência dos Animais de Laboratório , Masculino , Camundongos , Camundongos Endogâmicos C57BL , Estudos Prospectivos
11.
Artif Organs ; 42(9): 918-921, 2018 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-29660857

RESUMO

The objective of this study was to compare the effects of nonpulsatile and ECG-synchronized pulsatile extracorporeal life support on coronary and carotid blood flow velocities using transthoracic echocardiography and vascular ultrasound, respectively. Nine adult swine were randomly separated into nonpulsatile (NP, n = 5) and pulsatile (P, N = 4) groups and placed on ECLS for 24 h using an i-cor ECLS system. Noninvasive transthoracic images of the left and right coronary artery and the left carotid artery were acquired at the pre-ECLS (baseline), 30 min, 3, 6, 9, 12, and 24 h on-ECLS stages. The mean diastolic velocity of the left and right coronary arteries in the NP group significantly decreased after 24 h on ECLS compared to the baseline and 30 min ECLS stages (P < 0.05). There was no statistical difference in the mean diastolic velocity of the coronary arteries in the P group at 30 min, 3-, 6-, 9-, 12-, and 24-h ECLS compared to baseline. The P group showed a smaller decrease in the mean diastolic velocity of coronary arteries between the 30-min ECLS and 3-, 6-, 9-, 13-, 24-h ECLS stages compared to the NP group. The diastolic velocity of the left carotid artery in the NP group significantly decreased during 24-h ECLS compared to the P group (P < 0.05). An ECG-synchronized pulsatile ECLS system appeared to maintain coronary and carotid artery diastolic velocities better than conventional nonpulsatile ECLS. Further investigation of the perfusion modes during ECLS is warranted.


Assuntos
Velocidade do Fluxo Sanguíneo/fisiologia , Pressão Sanguínea/fisiologia , Artérias Carótidas/fisiologia , Vasos Coronários/fisiologia , Oxigenação por Membrana Extracorpórea/métodos , Fluxo Sanguíneo Regional/fisiologia , Animais , Hemodinâmica/fisiologia , Modelos Animais , Fluxo Pulsátil/fisiologia , Suínos , Resistência Vascular/fisiologia
13.
Vet Anaesth Analg ; 44(1): 133-137, 2017 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-27374253

RESUMO

OBJECTIVE: To describe an ultrasound-guided approach for venous and arterial vascular access and catheterization in anesthetized adult Yorkshire cross-bred pigs. STUDY DESIGN: Prospective experimental study. ANIMALS: Ten adult female Yorkshire cross-bred pigs, weighing 78.4 ± 5.6 kg (mean ± standard deviation). METHODS: Using ultrasound guidance and the Seldinger technique, a 7 Fr, 20 cm triple-lumen central venous catheter was placed in the external jugular vein and an 18 gauge, 16 cm catheter was placed in the femoral artery. The success rate of catheterization and the incidence of catheter patency over 24 hours of general anesthesia were recorded. RESULTS: Catheterization of the external jugular vein was successful in 10 out of 10 pigs and catheterization of the femoral artery was successful in eight out of 10 pigs. A surgical dissection technique on the femoral artery was performed in two pigs. Venous and arterial catheter patency was maintained in all pigs over the 24 hour study period. CONCLUSIONS AND CLINICAL RELEVANCE: Ultrasound guidance resulted in success rates of 100% for catheterization of the external jugular vein and 80% for catheterization of the femoral artery in anesthetized adult Yorkshire cross-bred pigs. This technique is a noninvasive, easily performed alternative to surgical exposure of the vessels in large pigs undergoing surgical instrumentation for biomedical device testing.


Assuntos
Cateterismo Venoso Central/veterinária , Artéria Femoral , Veias Jugulares , Ultrassonografia de Intervenção/veterinária , Anestesia/veterinária , Animais , Cateterismo , Cateterismo Venoso Central/métodos , Feminino , Estudos Prospectivos , Suínos , Ultrassonografia
15.
Artif Organs ; 39(7): E90-E101, 2015 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-25866125

RESUMO

The primary objective of this study was to evaluate a novel electrocardiogram (ECG)-synchronized pulsatile extracorporeal life support (ECLS) system for adult partial mechanical circulatory support for adequate quality of pulsatility and enhanced hemodynamic energy generation in an in vivo animal model. The secondary aim was to assess end-organ protection during nonpulsatile versus synchronized pulsatile flow mode. Ten adult swine were randomly divided into a nonpulsatile group (NP, n = 5) and pulsatile group (P, n = 5), and placed on ECLS for 24 h using an i-cor system consisting of an i-cor diagonal pump, an iLA membrane ventilator, an 18 Fr femoral arterial cannula and a 23/25 Fr femoral venous cannula. Trials were conducted at a flow rate of 2.5 L/min using nonpulsatile or pulsatile mode (with assist ratio 1:1). Real-time pressure and flow data were recorded using a custom-based data acquisition system. To the best of our knowledge, the oxygenator and circuit pressure drops were the lowest for any available system in both groups. The ECG-synchronized i-cor ECLS system was able to trigger pulsatile flow in the porcine model. After 24-h ECLS, energy equivalent pressure, surplus hemodynamic energy, and total hemodynamic energy at preoxygenator and prearterial cannula sites were significantly higher in the P group than those in the NP group (P < 0.05). Urine output was higher in P versus NP (3379 ± 443 mL vs. NP, 2598 ± 1012 mL), and the P group seemed to require less inotropic support, but both did not reach statistical significances (P > 0.05). The novel i-cor system performed well in the nonpulsatile and ECG-synchronized pulsatile mode in an adult animal ECLS model. The iLA membrane oxygenator had an extremely lower transmembrane pressure gradient and excellent gas exchange capability. Our findings suggest that ECG-triggered pulsatile ECLS provides superior end-organ protection with improved renal function and systemic vascular tone.


Assuntos
Oxigenação por Membrana Extracorpórea , Hemodinâmica , Sistemas de Manutenção da Vida , Animais , Eletrocardiografia , Desenho de Equipamento , Oxigenação por Membrana Extracorpórea/instrumentação , Feminino , Sistemas de Manutenção da Vida/instrumentação , Modelos Animais , Polienos/química , Fluxo Pulsátil , Suínos
16.
J Zoo Wildl Med ; 45(3): 638-41, 2014 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-25314833

RESUMO

A 1-yr-old female Canada lynx (Lynx canadensis) presented for sudden onset of rapidly progressive bilateral pelvic limb paralysis. The lynx was chemically immobilized to perform a physical examination but expired shortly thereafter. On postmortem radiographs, there were myriad small irregular, round-to-spherical gas densities within the skeletal muscle of the right thigh and epaxial musculature. At gross necropsy, the muscles of the right thigh, right lateral abdominal wall, and epaxial region were emphysematous and necrohemorrhagic, with subcutaneous and muscular crepitant swelling. Multiple skin puncture wounds, consistent with bites, were present over the affected tissues. Clostridium septicum was isolated in pure anaerobic culture from the musculature of the right hind limb. Histopathologic examination confirmed the diagnosis of acute, severe necrohemorrhagic and gangrenous myositis and cellulitis. Gram stains demonstrated large gram-positive bacilli with subterminal spores. This is the first known documented case of C. septicum myonecrosis in a nondomestic felid.


Assuntos
Infecções por Clostridium/veterinária , Clostridium septicum , Lynx , Doenças Musculares/veterinária , Animais , Infecções por Clostridium/microbiologia , Infecções por Clostridium/patologia , Evolução Fatal , Feminino , Doenças Musculares/microbiologia
17.
J Am Assoc Lab Anim Sci ; 53(6): 675-83, 2014 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-25650975

RESUMO

Butorphanol and buprenorphine are common analgesics used in laboratory mice. Inadvertent attenuation of the antinociceptive effects of these analgesics via the administration of an anesthetic reversal agent could result in postprocedural pain and distress, with subsequent negative effects on animal welfare, study outcomes, and regulatory compliance. This study was undertaken to determine whether atipamezole reverses ketamine-dexmedetomidine anesthesia and alters the antinociceptive effects of butorphanol and buprenorphine in female C57BL/6J mice. Atipamezole reliably reversed the anesthetic effects of ketamine-dexmedetomidine, and mice were ambulatory 17.4 ± 30.6 min after administration of the α2-adrenoreceptor antagonist. Atipamezole alone had no significant effect on tail-flick latency and did not alter the antinociceptive properties of butorphanol or low-dose (0.05 mg/kg) or high-dose (0.1 mg/kg) buprenorphine in female C57BL/6J mice. After reversal of ketamine-dexmedetomidine anesthesia, tail-flick latency at 30, 60, and 150 min after analgesic treatment differed significantly between mice treated with atipamezole alone and those given atipamezole followed by butorphanol or high-dose buprenorphine. These results suggest that the analgesic effects of butorphanol and buprenorphine are not affected by atipamezole. Buprenorphine (0.1 mg/kg) administered 30 min prior to or at the time of anesthesia resulted in a greater magnitude of antinociception after antagonism of anesthesia than when given at the time of reversal. Given these results, we recommend the use of ketamine-dexmedetomidine anesthesia with buprenorphine administered either preemptively or at the time of anesthetic induction to provide a defined period of surgical anesthesia that is effectively reversed by atipamezole.


Assuntos
Antagonistas de Receptores Adrenérgicos alfa 2/administração & dosagem , Anestesia/veterinária , Imidazóis/administração & dosagem , Camundongos , Analgésicos/administração & dosagem , Anestésicos/administração & dosagem , Animais , Buprenorfina/administração & dosagem , Butorfanol/administração & dosagem , Dexmedetomidina/administração & dosagem , Feminino , Ketamina/administração & dosagem , Camundongos Endogâmicos C57BL
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...