Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Vasc Access ; : 11297298231199505, 2023 Nov 29.
Artigo em Inglês | MEDLINE | ID: mdl-38018777

RESUMO

INTRODUCTION: Intraprocedural tip control techniques are critical during central venous catheter placement. According to international guidelines (INS 2021), intracavitary electrocardiography is the first method of choice to verify it; when this technique is not feasible, it is considered acceptable to use a contrast-enhanced ultrasound-based tip location method, commonly known as "bubble-test" as an effective alternative. OBJECTIVE: To assess whether the length of the vascular catheter can alter the time between the injection of the contrast media and its appearance at the catheter tip and the injection duration. Differences between operators stratified according to experience were evaluated as secondary endpoints. METHODS: A bench study was conducted using an extracorporeal circuit. For each catheter length (60, 40, and 20 cm), three injections were obtained by each of the five operators with different levels of experience for a total of 45 measurements. Differences among operators were evaluated using ANOVA, and the impact of catheter length and operator expertise on times was assessed using repeated measurement models. RESULTS: Hub-to-tip times of 247.33 ms (SD 168.82), 166 ms (SD 95.46), 138 ms (SD 54.48), and injection duration of 1620 ms (SD 748.58), 1614 ms (SD 570.95), 1566 ms (SD 302.83) were observed for 60, 40, 20 cm catheter length, respectively. A significant time variability between operators was observed. Moreover, moving from 60 to 20 cm, hub-to-tip time was significantly longer for 60 cm devices (p = 0.0124), while little differences were observed for injection duration. CONCLUSIONS: Catheter length can change both the time between the injection of the contrast media and its appearance at the catheter tip and the injection duration. Hub-to-tip times obtained with 20 and 40 cm and overall injection duration did not differ significantly; skilled personnel could substantially reduce both values analyzed in this study.

2.
Diagn Interv Imaging ; 104(6): 297-306, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-36813659

RESUMO

PURPOSE: The purpose of this study was to analyze the imaging features of extraskeletal osteosarcomas (ESOS) on computed tomography (CT) and magnetic resonance imaging (MRI) and to investigate their associations with overall survival (OS) using uni- and multivariable survival analyses. MATERIALS AND METHODS: This two-center retrospective study included all consecutive adult patients between 2008 and 2021 with histopathologically-proven ESOS who underwent pre-treatment CT and/or MRI. Clinical and histological characteristics, ESOS presentation on CT and MRI, treatment and outcomes were reported. Survival analyses were performed using Kaplan-Meier analysis and Cox regressions. Associations between imaging features and OS were searched using uni- and multivariable analyses. RESULTS: Fifty-four patients were included (30/54 [56%] men, median age: 67.5 years). Twenty-four died of ESOS (median OS: 18 months). ESOS were mostly deep-seated (46/54, 85%) in the lower limb (27/54, 50%) with a median size of 95 mm (interquartile range: 64, 142; range: 21-289 mm). Mineralization was seen on 26/42 (62%) patients, mainly gross-amorphous (18/26; 69%). ESOS were generally highly heterogeneous on T2-weighted images (38/48; 79%) and contrast-enhanced (CE) T1-weighted images (29/40; 72%), with necrosis (39/40; 97%), well-defined or focally infiltrative margins (39/47; 83%), with moderate peritumoral edema (39/47; 83%) and rim-like peripheral enhancement (17/40; 42%). Size, location, mineralization on CT, signal intensity heterogeneity on T1-, T2- and CE-T1-weighted images and hemorragic signal on MRI were associated with poorer OS (range of log-rank P = 0.0069-0.0485). At multivariable analysis, hemorragic signal and signal intensity heterogeneity on T2-weighted images remained predictive for poorer OS (hazard ratio [HR] = 2.68, P = 0.0299; HR = 9.85, P = 0.0262, respectively) CONCLUSION: ESOS typically presents as mineralized heterogeneous and necrotic soft tissue tumor with a possible rim-like enhancement and limited peritumoral abnormalities. MRI may help estimate outcome of patients with ESOS.


Assuntos
Neoplasias Ósseas , Osteossarcoma , Neoplasias de Tecidos Moles , Adulto , Masculino , Humanos , Idoso , Feminino , Estudos Retrospectivos , Osteossarcoma/diagnóstico por imagem , Osteossarcoma/terapia , Neoplasias de Tecidos Moles/patologia , Tomografia Computadorizada por Raios X , Imageamento por Ressonância Magnética/métodos , Neoplasias Ósseas/diagnóstico por imagem , Neoplasias Ósseas/terapia
3.
Diagnostics (Basel) ; 12(4)2022 Apr 02.
Artigo em Inglês | MEDLINE | ID: mdl-35453939

RESUMO

Liver iron overload is defined as an accumulation of the chemical element Fe in the hepatic parenchyma that exceeds the normal storage. When iron accumulates, it can be toxic for the liver by producing inflammation and cell damage. This can potentially lead to cirrhosis and hepatocellular carcinoma, as well as to other liver lesions depending on the underlying condition associated to liver iron overload. The correct assessment of liver iron storage is pivotal to drive the best treatment and prevent complication. Nowadays, magnetic resonance imaging (MRI) is the best non-invasive modality to detect and quantify liver iron overload. However, due to its superparamagnetic properties, iron provides a natural source of contrast enhancement that can make challenging the differential diagnosis between different focal liver lesions (FLLs). To date, a fully comprehensive description of MRI features of liver lesions commonly found in iron-overloaded liver is lacking in the literature. Through an extensive review of the published literature, we aim to summarize the MRI signal intensity and enhancement pattern of the most common FLLs that can occur in liver iron overload.

4.
Early Hum Dev ; 90 Suppl 2: S47-9, 2014 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-25220128

RESUMO

Systemic infection is a major cause of mortality and morbidity among premature neonates. In this fragile population, the immaturity of the innate immune response relates inversely to gestational age and is one of the determinants of susceptibility to infections. Antibiotic therapy, even when appropriately and timely instituted, may fail to prevent death or significant sequelae. The quest for additional strategies is still open; in this scenario, the supplementation with exogenous immunoglobulins represents an attractive additional strategy of defence. As current data are conflicting, we provide a critical appraisal with a focus on IgM enriched immunoglobulins preparations.


Assuntos
Imunoglobulina M/imunologia , Imunoterapia , Sepse/imunologia , Humanos , Imunoglobulina M/uso terapêutico , Imunoglobulinas Intravenosas/uso terapêutico , Recém-Nascido , Sepse/terapia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...