Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Intervalo de ano de publicação
1.
BMC Med ; 22(1): 278, 2024 Jul 02.
Artigo em Inglês | MEDLINE | ID: mdl-38956533

RESUMO

BACKGROUND: APRI and FIB-4 scores are used to exclude clinically significant fibrosis (defined as stage ≥ F2) in patients with chronic viral hepatitis. However, the cut-offs for these scores (generated by Youden indices) vary between different patient cohorts. This study aimed to evaluate whether serum dithiothreitol-oxidizing capacity (DOC), i.e., a surrogate test of quiescin sulfhydryl oxidase-1, which is a matrix remodeling enzyme, could be used to non-invasively identify significant fibrosis in patients with various chronic liver diseases (CLDs). METHODS: Diagnostic performance of DOC was compared with APRI and FIB-4 for identifying significant fibrosis. ROC curve analyses were undertaken in: a) two chronic hepatitis B (CHB) cohorts, independently established from hospitals in Wenzhou (n = 208) and Hefei (n = 120); b) a MASLD cohort from Wenzhou hospital (n = 122); and c) a cohort with multiple CLD etiologies (except CHB and MASLD; n = 102), which was identified from patients in both hospitals. Cut-offs were calculated using the Youden index. All CLD patients (n = 552) were then stratified by age for ROC curve analyses and cut-off calculations. RESULTS: Stratified by CLD etiology or age, ROC curve analyses consistently showed that the DOC test was superior to APRI and FIB-4 for discriminating between clinically significant fibrosis and no fibrosis, when APRI and FIB-4 showed poor/modest diagnostic performance (P < 0.05, P < 0.01 and P < 0.001 in 3, 1 and 3 cohort comparisons, respectively). Conversely, the DOC test was equivalent to APRI and FIB-4 when all tests showed moderate/adequate diagnostic performances (P > 0.05 in 11 cohort comparisons). DOC had a significant advantage over APRI or FIB-4 scores for establishing a uniform cut-off independently of age and CLD etiology (coefficients of variation of DOC, APRI and FIB-4 cut-offs were 1.7%, 22.9% and 47.6% in cohorts stratified by CLD etiology, 2.0%, 26.7% and 29.5% in cohorts stratified by age, respectively). The uniform cut-off was 2.13, yielded from all patients examined. Surprisingly, the uniform cut-off was the same as the DOC upper limit of normal with a specificity of 99%, estimated from 275 healthy control individuals. Hence, the uniform cut-off should possess a high negative predictive value for excluding significant fibrosis in primary care settings. A high DOC cut-off with 97.5% specificity could be used for detecting significant fibrosis (≥ F2) with an acceptable positive predictive value (87.1%). CONCLUSIONS: This proof-of-concept study suggests that the DOC test may efficiently rule out and rule in significant liver fibrosis, thereby reducing the numbers of unnecessary liver biopsies. Moreover, the DOC test may be helpful for clinicians to exclude significant liver fibrosis in the general population.


Assuntos
Biomarcadores , Ditiotreitol , Cirrose Hepática , Humanos , Cirrose Hepática/diagnóstico , Cirrose Hepática/sangue , Masculino , Pessoa de Meia-Idade , Biomarcadores/sangue , Feminino , Adulto , Idoso , Oxirredução , Curva ROC , Estudos de Coortes , Oxirredutases atuantes sobre Doadores de Grupo Enxofre/sangue , Estudo de Prova de Conceito
2.
Artigo em Chinês | WPRIM (Pacífico Ocidental) | ID: wpr-1016572

RESUMO

@#Pediatric malocclusion is common in dentistry. Some children with malocclusion combined with obstructive sleep apnea-hypopnea syndrome (OSAHS) often fail to receive appropriate treatment due to a lack of multidisciplinary diagnosis and treatment. It can cause abnormal ventilation during sleep, affecting the central nervous system and cardiovascular development and even causing neurological and behavioral problems. Pediatric OSAHS is caused by the narrowing of the upper respiratory tract, characterized by specific facial bone characteristics and neuromuscular factors and correlated with malocclusion. Due to its diverse clinical manifestations and etiology, the diagnosis and treatment of pediatric OSAHS require an interdisciplinary, personalized, and specialized approach. Questionnaires and physical examinations can be used for preliminary screening. Moreover, children's stomatology and otorhinolaryngology examinations are the basis for disease diagnosis. Polysomnography (PSG) is currently the direct diagnostic method. There are various treatment methods for OSAHS in children, and for OSAHS caused by adenoid tonsil hypertrophy, adenoidectomy and tonsillectomy are the main treatments. Othodontic treatment including mandibular advancement and rapid maxillary expansion et al is also effective for OSAHS in children with malocclusion. Currently, there is limited research on the correlation between childhood malocclusion and OSAHS, and multidisciplinary combination therapy may improve the cure rate, but there is a lack of sufficient evidence. In the future, the pathogenesis of OSAHS should be further elucidated, and research on multidisciplinary combination therapy should be promoted to achieve early intervention and treatment for potential and existing patients.

3.
J Clin Endocrinol Metab ; 109(6): 1540-1549, 2024 May 17.
Artigo em Inglês | MEDLINE | ID: mdl-38124275

RESUMO

CONTEXT: There is limited data on the clinical significance of metabolic hyperferritinemia (MHF) based on the most recent consensus. OBJECTIVE: We aimed to validate the clinical outcomes of MHF in the general population and patients with biopsy-proven metabolic dysfunction-associated fatty liver disease (MAFLD). METHODS: The NHANES database and PERSONS cohort were included. MHF was defined as elevated serum ferritin with metabolic dysfunction (MD) and stratified into different grades according to ferritin (grade 1: 200 [females]/300 [males]-550 ng/mL; grade 2: 550-1000 ng/mL; grade 3: >1000 ng/mL). The clinical outcomes, including all-cause death, comorbidities, and liver histology, were compared between non-MHF and MHF in adjusted models. RESULTS: In NHANES, compared with non-MHF with MD, MHF was related to higher risks of advanced fibrosis (P = .036), elevated albumin-creatinine ratio (UACR, P = .001), and sarcopenia (P = .013). Although the association between all grades of MHF and mortality was insignificant (P = .122), grades 2/3 was associated with increased mortality (P = .029). When comparing with non-MHF without MD, the harmful effects of MHF were more significant in mortality (P < .001), elevated UACR (P < .001), cardiovascular disease (P = .028), and sarcopenia (P < .001). In the PERSONS cohort, MHF was associated with more advanced grades of steatosis (P < .001), lobular inflammation (P < .001), advanced fibrosis (P = .017), and more severe hepatocellular iron deposition (P < .001). CONCLUSION: Both in the general population and in at-risk individuals with MAFLD, MHF was related with poorer clinical outcomes.


Assuntos
Ferritinas , Hiperferritinemia , Humanos , Feminino , Masculino , Pessoa de Meia-Idade , Adulto , Estudos de Coortes , Hiperferritinemia/sangue , Hiperferritinemia/diagnóstico , Ferritinas/sangue , Consenso , Inquéritos Nutricionais , Idoso , Prognóstico
4.
Rev Sci Instrum ; 84(6): 063106, 2013 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-23822332

RESUMO

To prepare for projects such as the Large Hadron Collider upgrade, International Thermonuclear Experimental Reactor and Demonstration reactor, it is important to form a clear understanding of stress-strain properties of the materials that make up superconducting magnets. Thus, we have been studying the mechanical properties of superconducting wires using neutron diffraction measurements. To simulate operational conditions such as temperature, stress, and strain, we developed a cryogenic load frame for stress-strain measurements of materials using a neutron diffractometer at Japan Proton Accelerator Research Complex (J-PARC) Takumi beam line. The maximum load that can be applied to a sample using an external driving machine is 50 kN. Using a Gifford-MacMahon cryocooler, samples can be measured down to temperatures below 10 K when loaded. In the present paper, we describe the details of the cryogenic load frame with its test results by using type-304 stainless steel wire.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...