Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Am Coll Radiol ; 21(4): 624-632, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37336431

RESUMO

BACKGROUND: Previously we reported a manual method of measuring thoracic vertebral bone mineral density (BMD) using quantitative CT in noncontrast cardiac CT scans used for coronary artery calcium (CAC) scoring. In this report, we present validation studies of an artificial intelligence-based automated BMD measurement (AutoBMD) that recently received FDA approval as an opportunistic add-on to CAC scans. METHODS: A deep learning model was trained to detect vertebral bodies. Subsequently, signal processing techniques were developed to detect intervertebral discs and the trabecular components of the vertebral body. The model was trained using 132 CAC scans comprising 7,649 slices. To validate AutoBMD, we used 5,785 cases of manual BMD measurements previously reported from CAC scans in the Multi-Ethnic Study of Atherosclerosis. RESULTS: Mean ± SD for AutoBMD and manual BMD were 166.1 ± 47.9 mg/cc and 163.1 ± 46 mg/cc, respectively (P = .006). Multi-Ethnic Study of Atherosclerosis cases were 47.5% male and 52.5% female, with age 62.2 ± 10.3. A strong correlation was found between AutoBMD and manual measurements (R = 0.85, P < .0001). Accuracy, sensitivity, specificity, positive predictive value and negative predictive value for AutoBMD-based detection of osteoporosis were 99.6%, 96.7%, 97.7%, 99.7% and 99.8%, respectively. AutoBMD averaged 15 seconds per report versus 5.5 min for manual measurements (P < .0001). CONCLUSIONS: AutoBMD is an FDA-approved, artificial intelligence-enabled opportunistic tool that reports BMD with Z-scores and T-scores and accurately detects osteoporosis and osteopenia in CAC scans, demonstrating results comparable to manual measurements. No extra cost of scanning and no extra radiation to patients, plus the high prevalence of asymptomatic osteoporosis, make AutoBMD a promising candidate to enhance patient care.


Assuntos
Aterosclerose , Osteoporose , Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Idoso , Densidade Óssea , Cálcio , Vasos Coronários , Inteligência Artificial , Tomografia Computadorizada por Raios X/métodos , Osteoporose/diagnóstico por imagem , Absorciometria de Fóton
2.
Eur J Radiol Open ; 10: 100492, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37214544

RESUMO

Rationale and objectives: We previously reported a novel manual method for measuring bone mineral density (BMD) in coronary artery calcium (CAC) scans and validated our method against Dual X-Ray Absorptiometry (DEXA). Furthermore, we have developed and validated an artificial intelligence (AI) based automated BMD (AutoBMD) measurement as an opportunistic add-on to CAC scans that recently received FDA approval. In this report, we present evidence of equivalency between AutoBMD measurements in cardiac vs lung CT scans. Materials and methods: AI models were trained using 132 cases with 7649 (3 mm) slices for CAC, and 37 cases with 21918 (0.5 mm) slices for lung scans. To validate AutoBMD against manual measurements, we used 6776 cases of BMD measured manually on CAC scans in the Multi-Ethnic Study of Atherosclerosis (MESA). We then used 165 additional cases from Harbor UCLA Lundquist Institute to compare AutoBMD in patients who underwent both cardiac and lung scans on the same day. Results: Mean±SD for age was 69 ± 9.4 years with 52.4% male. AutoBMD in lung and cardiac scans, and manual BMD in cardiac scans were 153.7 ± 43.9, 155.1 ± 44.4, and 163.6 ± 45.3 g/cm3, respectively (p = 0.09). Bland-Altman agreement analysis between AutoBMD lung and cardiac scans resulted in 1.37 g/cm3 mean differences. Pearson correlation coefficient between lung and cardiac AutoBMD was R2 = 0.95 (p < 0.0001). Conclusion: Opportunistic BMD measurement using AutoBMD in CAC and lung cancer screening scans is promising and yields similar results. No extra radiation plus the high prevalence of asymptomatic osteoporosis makes AutoBMD an ideal screening tool for osteopenia and osteoporosis in CT scans done for other reasons.

3.
Neurol Clin ; 36(1): 119-133, 2018 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-29157393

RESUMO

In the past several decades, MRI has become an indispensable tool in the field of multiple sclerosis (MS) for clinicians and researchers. However, the MS field still faces several challenges. This review focuses on 2 current areas of difficulty: 1) discriminating MS from other diseases when the clinical history and imaging features are atypical or nonspecific, and 2) the lack of quantitative imaging metrics with which to follow MS patients over time in clinical practice. This review highlights promising MRI and postprocessing techniques that have potential applications in these areas. With further study, these tools could be usefully integrated into clinical care.


Assuntos
Imageamento por Ressonância Magnética/métodos , Esclerose Múltipla/diagnóstico por imagem , Neuroimagem/métodos , Humanos
4.
Artigo em Inglês | MEDLINE | ID: mdl-22256215

RESUMO

Intra-operative brain deformation (brain shift) limits the accuracy of image-guided neuro-surgery systems. Ultrasound imaging as a simple, fast and being real time has become an alternative to MR imaging which is an expensive system for brain shift calculation. The main challenges due to speckle noise and artifacts in US images, is to perform an accurate and fast registration of Us images with pre-operative MR images. In this paper an efficient point based registration method based on the alignment of probability density functions called Coherent Point Drift (CPD) is implemented and compared to the conventional ICP method. To perform this, a brain phantom that allows simulating the brain deformation is made. As the results of our phantom study confirm the CPD method clearly outperforms the ICP algorithm for brain shift calculation. Also the result proves that using intra-operative US has led to recover almost 80% of displacement in the region of interest.


Assuntos
Encéfalo/cirurgia , Ecoencefalografia/métodos , Processamento de Imagem Assistida por Computador/métodos , Cuidados Intraoperatórios/métodos , Imageamento por Ressonância Magnética/métodos , Imagens de Fantasmas , Algoritmos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...