Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 26
Filtrar
1.
Eur Radiol ; 26(8): 2705-13, 2016 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-26515548

RESUMO

OBJECTIVES: This study was conducted in order to compare a high resolution, non-contrast-enhanced MRA (NATIVE SPACE, NE-MRA) of the pedal vasculature with contrast-enhanced MRA (CE-MRA) and digital subtraction angiography (DSA) in patients with peripheral arterial occlusive disease (PAOD). METHODS: The prospective study consists of 20 PAOD patients. All patients underwent percutaneous transluminal angioplasty or stenting and received MR angiographies the following day. RESULTS: With CE-MRA, 75.7 % of vessel segments showed good, 16.4 % suboptimal and 7.9 % not usable image quality. With NE-MRA, 64.6 % showed good, 18.6 % suboptimal and 16.8 % not usable image quality. CE-MRA showed a sensitivity and negative predictive value of 90 %/95 % regarding significant stenosis (greater than 50 %), and specificity and positive predictive value were 88 %/77 %. Accordingly, sensitivity and negative predictive value for the NE-MRA were 96 %/97 % and specificity and positive predictive value were 80 %/69 % for stenoses greater than 50 %. CONCLUSIONS: The applied NE-MRA technique achieves high diagnostic accuracy even in very small distal arteries of the foot. However, the rate of non-diagnostic vessel segments is considerably higher for NE-MRA than for CE-MRA. NE-MRA is a valuable alternative to CE-MRA in selected patients. KEY POINTS: • Comparison of non-enhanced MRA with contrast-enhanced MRA and DSA as gold standard. • High resolution MRA at 3 T for the depiction of small pedal vessels. • Evaluation of high resolution non-enhanced MRA in PAOD patients.


Assuntos
Angiografia Digital/métodos , Arteriopatias Oclusivas/diagnóstico , Artérias/diagnóstico por imagem , Eletrocardiografia/métodos , Pé/irrigação sanguínea , Angiografia por Ressonância Magnética/métodos , Adulto , Idoso , Arteriopatias Oclusivas/fisiopatologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Estudos Prospectivos , Veias/diagnóstico por imagem
2.
Swiss Med Wkly ; 144: w13913, 2014 Mar 20.
Artigo em Inglês | MEDLINE | ID: mdl-24652665

RESUMO

Transcatheter (or percutaneous) renal denervation is a novel technique developed for the treatment of resistant hypertension. So far, only one randomised controlled trial has been published, which has shown a reduction of office blood pressure. The Swiss Society of Hypertension, the Swiss Society of Cardiology, The Swiss Society of Angiology and the Swiss Society of Interventional Radiology decided to establish recommendations to practicing physicians and specialists for good clinical practice. The eligibility of patients for transcatheter renal denervation needs (1.) confirmation of truly resistant hypertension, (2.) exclusion of secondary forms of hypertension, (3.) a multidisciplinary decision confirming the eligibility, (4.) facilities that guarantee procedural safety and (5.) a long-term follow-up of the patients, if possible in cooperation with a hypertension specialist. These steps are essential until long-term data on safety and efficacy are available.


Assuntos
Hipertensão/cirurgia , Rim/inervação , Simpatectomia , Anti-Hipertensivos/uso terapêutico , Pressão Arterial , Consenso , Resistência a Medicamentos , Humanos , Hipertensão/tratamento farmacológico , Seleção de Pacientes , Suíça , Simpatectomia/efeitos adversos , Simpatectomia/métodos
3.
Semin Musculoskelet Radiol ; 17(4): 396-406, 2013 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-24101180

RESUMO

Within the past 15 years, significant advances in the imaging of multiorgan and complex trauma primarily due to the improvement of cross-sectional imaging have resulted in the optimization of the expedient diagnosis and management of the polytrauma patient. At the forefront, multidetector computed tomography (MDCT) has become the cornerstone of modern emergency departments and trauma centers. In many institutions, MDCT is the de facto diagnostic tool upon trauma activation. In the setting of pelvic imaging, MDCT (with its high spatial resolution and sensitivity as well as short acquisition times) allows for rapid identification and assessment of pelvic hemorrhage leading to faster triage and definitive management. In trauma centers throughout the world, angiography and minimally invasive catheter-based embolization techniques performed by interventional radiologists have become the standard of care for patients with acute pelvic trauma and related multiorgan hemorrhage. In an interdisciplinary setting, embolization may be performed either alone or as an adjunct procedure with open or closed reduction and stabilization techniques. A team-based approach involving multiple disciplines (e.g., radiology, traumatology, orthopedic surgery, intensive care medicine) is crucial to monitor and treat the actively bleeding patient appropriately.


Assuntos
Embolização Terapêutica , Fraturas Ósseas/complicações , Fraturas Ósseas/diagnóstico por imagem , Hemorragia/diagnóstico por imagem , Hemorragia/etiologia , Hemorragia/terapia , Pelve/diagnóstico por imagem , Pelve/lesões , Tomografia Computadorizada por Raios X/métodos , Ferimentos não Penetrantes/complicações , Doença Aguda , Angiografia/métodos , Meios de Contraste , Humanos , Imageamento Tridimensional
4.
Cardiovasc Intervent Radiol ; 36(4): 1055-62, 2013 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-23232857

RESUMO

PURPOSE: The present study was designed to evaluate the geometrical accuracy and clinical applicability of a new, free-hand, CT-guided, optical navigation system. METHODS: Fifteen procedures in 14 consecutive patients were retrospectively analyzed. The navigation system was applied for interventional procedures on small target lesions, in cases with long needle paths, narrow access windows, or when an out-of-plane access was expected. Mean lesion volume was 27.9 ml, and mean distance to target measured was 107.5 mm. Eleven of 15 needle trajectories were planned as out-of-plane approaches regarding the axial CT plane. RESULTS: Ninety-one percent of the biopsies were diagnostic. All therapeutic interventions were technically successful. Targeting precision was high with a mean distance of the needle tip from planned target of 1.98 mm. Mean intervention time was 1:12 h. A statistically significant correlation between angular needle deviation and intervention time (p = 0.007), respiratory movement of the target (p = 0.008), and body mass index (p = 0.02) was detected. None of the evaluated parameters correlated significantly with the distance from the needle tip to the planned target. CONCLUSIONS: The application of a navigation system for complex CT-guided procedures provided safe and effective targeting within a reasonable intervention time in our series.


Assuntos
Biópsia Guiada por Imagem/instrumentação , Dispositivos Ópticos , Cirurgia Assistida por Computador/instrumentação , Tomografia Computadorizada por Raios X/métodos , Idoso , Idoso de 80 Anos ou mais , Biópsia por Agulha Fina/métodos , Estudos de Casos e Controles , Desenho de Equipamento , Segurança de Equipamentos , Feminino , Mãos , Humanos , Biópsia Guiada por Imagem/métodos , Masculino , Pessoa de Meia-Idade , Radiografia Intervencionista , Valores de Referência , Estudos Retrospectivos , Sensibilidade e Especificidade , Cirurgia Assistida por Computador/métodos
6.
Cardiovasc Intervent Radiol ; 34(6): 1296-302, 2011 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-21305283

RESUMO

PURPOSE: This study was designed to demonstrate the applicability of a combined needle-based re-entry catheter and "cheese-wire" technique for fenestration of abdominal aortic dissection membranes. METHODS: Four male patients (mean age: 65 years) with acute complicated aortic type B dissections were treated at our institution by fenestrating the abdominal aortic dissection membrane using a hybrid technique. This technique combined an initial membrane puncture with a needle-based re-entry catheter using a transfemoral approach. A guidewire was passed through the re-entry catheter and across the membrane. Using a contralateral transfemoral access, this guidewire was then snared, creating a through-and-through wire access. The membrane was then fenestrated using the cheese-wire maneuver. RESULTS: We successfully performed: (a) membrane puncture; (b) guidewire passage; (c) guidewire snaring; and (d) cheese-wire maneuver in all four cases. After this maneuver, decompression of the false lumen and acceptable arterial inflow into the true lumen was observed in all cases. The dependent visceral arteries were reperfused. In one case, portions of the fenestrated membrane occluded the common iliac artery, which was immediately and successfully stented. In another case, long-standing intestinal hypoperfusion before the fenestration resulted in reperfusion-related shock and intraoperative death of the patient. CONCLUSIONS: The described hybrid approach for fenestration of dissection membranes is technically feasible and may be established as a therapeutic method in cases with a complicated type B dissection.


Assuntos
Aneurisma da Aorta Abdominal/cirurgia , Dissecção Aórtica/cirurgia , Artéria Femoral , Agulhas , Dissecção Aórtica/diagnóstico por imagem , Angiografia , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Fluoroscopia , Humanos , Masculino , Pessoa de Meia-Idade , Punções , Tomografia Computadorizada por Raios X
7.
Eur J Radiol ; 80(3): e410-5, 2011 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-20951520

RESUMO

PURPOSE: We hypothesized that bone SPECT combined with multiplanar reconstructed CT can identify and target the pain-inducing focus in the foot and can be used to successfully guide anaesthetic infiltrations. Therefore we prospectively investigated feasibility and predictive value of bone SPECT/CT for image guided diagnostic infiltrations in patients with chronic foot pain. METHODS: All patients received a standardized bone SPECT/CT of both feet. The scintigraphically most active structures were subsequently infiltrated with local anaesthetics under CT-guidance. The pre- and post-infiltration pain intensity was measured using the visual analogue scale (VAS). Then, we assessed (i) the agreement on pain originating structures determined by standard clinical assessment versus SPECT/CT and (ii) the predictive value of SPECT-CT in groups with and without agreement. RESULTS: 27 of 30 participants reported a pain reduction on VAS of 50% or more, resulting in a response rate of 90%. When assessing the agreement on pain initiating structures determined by standard clinical assessment versus SPECT/CT, we found a disagreement in 16 of 30 (53%) cases. Particularly, disagreement appeared in all 9 participants with symptoms located in the mid-foot (100%). In participants with hind-foot pathology, disagreement was found in 7 of 21 cases (33%). CONCLUSION: The present study shows the feasibility of 99mTc-DPD-SPECT/CT guided infiltration of osseous structures of patients with chronic foot pain. 99mTc-DPD-SPECT/CT had a higher predictive value on the clinical outcome than the clinical assessment. In the clinical setting 99mTc-DPD-SPECT/CT might overrule the clinical assessment in case of disagreement on the target lesion.


Assuntos
Artralgia/diagnóstico , Artralgia/tratamento farmacológico , Bupivacaína/administração & dosagem , Diagnóstico por Computador/métodos , Difosfonatos , Compostos de Organotecnécio , Radiografia Intervencionista/métodos , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Adulto , Idoso , Anestésicos Locais/administração & dosagem , Articulação do Tornozelo/diagnóstico por imagem , Estudos de Coortes , Feminino , Humanos , Injeções Intralesionais , Masculino , Pessoa de Meia-Idade , Prognóstico , Estudos Prospectivos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Técnica de Subtração , Tomografia Computadorizada por Raios X/métodos , Resultado do Tratamento , Adulto Jovem
9.
Mol Ther ; 18(3): 651-9, 2010 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-19935776

RESUMO

Recombinant vaccinia virus (rVV) encoding tumor-associated antigens (TAAs) and adhesion or costimulatory molecules may represent important immunogenic reagents for cancer immunotherapy. Recently, intranodal (IN) antigen administration was suggested to be more immunogenic than intradermal (ID) vaccination. However, IN rVV administration has not been attempted so far. We used a rVV encoding gp100(280-288), Melan-A/MART-1(27-35) and tyrosinase(1-9) HLA-A0201 restricted epitopes and CD80 and CD86 costimulatory molecules in stage III and IV melanoma patients in a phase 1/2 trial. Of 15 patients initiating treatment, including two cycles of IN immunization, each comprising one rVV administration and three recall injections of the corresponding peptides, accompanied by subcutaneous granulocyte macrophage-colony stimulating factor supplementation, five withdrew due to progressing disease. Of 10 remaining patients seven showed evidence of induction of cytotoxic T lymphocytes (CTLs) directed against at least one epitope under investigation, as detectable by limiting dilution analysis (LDA) of specific precursors and multimer staining. Adverse reactions were mild (National Cancer Institute (NCI) grade 1-2) and mainly represented by fever, skin rashes, and pruritus. These data indicate that IN administration of rVV encoding melanoma-associated epitopes and costimulatory molecules is safe and immunogenic.


Assuntos
Antígenos de Neoplasias/metabolismo , Imunização/métodos , Melanoma/patologia , Melanoma/terapia , Vaccinia virus/metabolismo , Adulto , Idoso , Idoso de 80 Anos ou mais , Vacinas Anticâncer/uso terapêutico , Progressão da Doença , Epitopos/química , Feminino , Fator Estimulador de Colônias de Granulócitos e Macrófagos/metabolismo , Humanos , Linfonodos/patologia , Masculino , Pessoa de Meia-Idade , Metástase Neoplásica , Linfócitos T Citotóxicos/metabolismo
10.
Cardiovasc Intervent Radiol ; 33(1): 209-12, 2010 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-19214626

RESUMO

A 72-year-old man was referred to our department with an incidentally diagnosed bronchogenic carcinoma of the right upper lobe. Positron emission tomography (PET) combined with computed tomography (PET-CT) revealed an unexpected hot spot in the ventral wall of the infrarenal segment of the inferior vena cava (IVC). Diagnostic biopsy of this lesion was performed under CT guidance with semiautomated 20G fine-needle aspiration (FNA) through a 19G coaxial needle. Cytology revealed few carcinoma cells, which led to the remarkable diagnosis of a distant metastasis to the IVC wall. Both the immediate postinterventional CT control and the further surveillance period of the patient were unremarkable; in particular, no signs of bleeding complications were detected. We conclude that coaxial FNA of an IVC wall lesion is technically feasible and may even help diagnose distant metastasis.


Assuntos
Biópsia por Agulha Fina/métodos , Carcinoma Broncogênico/diagnóstico , Carcinoma Broncogênico/secundário , Neoplasias Pulmonares/patologia , Neoplasias Vasculares/patologia , Neoplasias Vasculares/secundário , Veia Cava Inferior/diagnóstico por imagem , Veia Cava Inferior/patologia , Idoso , Carcinoma Broncogênico/etiologia , Carcinoma Broncogênico/patologia , Humanos , Achados Incidentais , Neoplasias Pulmonares/diagnóstico , Neoplasias Pulmonares/etiologia , Masculino , Escleroderma Sistêmico/complicações , Tomografia Computadorizada por Raios X , Neoplasias Vasculares/etiologia
11.
World J Surg ; 33(11): 2477-89, 2009 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-19693630

RESUMO

BACKGROUND: The manifestations associated with non-survival after multiple trauma may vary importantly between countries and institutions. The aim of the present study was to assess the quality of performance by comparing actual mortality rates to the literature. METHODS: The study involved evaluation of a prospective consecutive multiple trauma cohort (injury severity score, ISS > 16) primarily admitted to a university hospital. Univariate and multivariate testing of routine parameters and scores, such as the Trauma and Injury Severity Score (TRISS), was used to determine their predictive powers for mortality. RESULTS: The 30-day mortality of 22.8% (n = 54) exactly matched predicted TRISS versions of Champion or the Major Trauma Outcome Study for our 237 multiple trauma patients (42.8 +/- 20.9 years; ISS 29.5 +/- 11.5). Univariate analysis revealed significant differences between survivors and non-survivors when compared for age, ISS, Glasgow coma scale (GCS), pulse oximeter saturation (SapO2), hemoglobin, prothrombin time, and lactate. In multivariate analysis, age, ISS, and GCS (P < 0.001 each) functioned as major independent prognostic parameters of both 24 h and 30-day mortality. Various TRISS versions hardly differed in their precision (area under the curve [AUC] 0.83-0.84), but they did differ considerably in their level of requirement, with the TRISS using newer National Trauma Data Bank coefficients (NTDB-TRISS) offering the highest target benchmark (predicted mortality 13%, Z value -5.7) in the prediction of 30-day mortality. CONCLUSIONS: Because of the current lack of a single, internationally accepted scoring system for the prediction of mortality after multiple trauma, the comparison of outcomes between medical centers remains unreliable. To achieve effective quality control, a practical benchmarking model, such as the TRISS-NTDB, should be used worldwide.


Assuntos
Benchmarking , Traumatismo Múltiplo/mortalidade , Centros de Traumatologia , Adulto , Feminino , Hospitais Universitários , Humanos , Masculino , Pessoa de Meia-Idade , Suíça , Índices de Gravidade do Trauma , Adulto Jovem
12.
Artigo em Inglês | MEDLINE | ID: mdl-19431070

RESUMO

The purpose of this study was to demonstrate first magnetic resonance (MR)-guided stenting of iliac and supraaortic arteries using a polyetheretherketone-based (PEEK) MR-compatible guide wire. In vitro and animal experiments were performed in a short magnet wide-bore scanner (1.5 Tesla, Espree, Siemens Healthcare, Erlangen, Germany). For all experiments, a 0.035'' MR-compatible guide wire prototoype was used. This wire had a compound core of PEEK with reinforcing fibres, a soft and atraumatic tip and a hydrophilic coating. For its passive visualization, paramagnetic markings were attached. All experiments were performed through a vascular introducer sheath under MR-guidance. In vitro repetitive selective over the wire catheterizations of either the right carotid artery and the left subclavian artery were performed. In vivo, selective catheterization and over-the-wire stenting of the brachiocephalic trunk and the left subclavian artery were performed. The common iliac arteries were catheterized retrogradely (left) and cross-over (right). Angioplasty and stenting were performed over-the-wire. All procedures were successful. Visibility of the PEEK-based guide-wire was rated good in vitro and acceptable in vivo. Guide wire pushability and endovascular device support were good. The PEEK-based MR-compatible guide wire is well visible and usable under MR-guidance. It supports over-the-wire treatment of iliac arteries and supraaortic arteries.


Assuntos
Cetonas , Imagem por Ressonância Magnética Intervencionista/métodos , Polietilenoglicóis , Stents , Angioplastia/métodos , Animais , Aorta/cirurgia , Benzofenonas , Materiais Biocompatíveis , Tronco Braquiocefálico/cirurgia , Cateterismo Cardíaco/instrumentação , Cateterismo Cardíaco/métodos , Desenho de Equipamento , Feminino , Artéria Ilíaca/cirurgia , Polímeros , Artéria Subclávia/cirurgia , Suínos
13.
Invest Radiol ; 44(4): 234-41, 2009 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-19252440

RESUMO

OBJECTIVES: Demonstrate the usability of a new polyetheretherketone (PEEK)-based MR-compatible guidewire for renal artery catheterization, angioplasty, and stenting under MR-guidance using MR-visible markers, in vitro and in vivo. MATERIAL AND METHODS: The new 0.035'' guidewire with fiber-reinforced PEEK core, a soft tip, and a hydrophilic coating was used. Paramagnetic markings were coated on the wire and nonbraided catheters for passive visualization. Bending stiffness of the guidewire was compared with available hydrophilic guidewires (Terumo Glidewire Stiff and Standard). A human aortic silicon phantom and 2 pigs were used. The study was animal care and use approved by the committee. Under MR-guidance, renal arteries were catheterized, balloon angioplasty was performed, and balloon expandable renal artery stents were deployed in vivo. Post mortem autopsy was performed. Guidewire visibility, pushability, steerability, and device-support capabilities of the marked guidewire were qualitatively assessed. Procedure times were recorded. RESULTS: Bending stiffness of the new PEEK-based wire was comparable with Standard Glidewire. In vitro and in vivo guidewire guidance, catheter configuration, renal artery catheterization, and balloon angioplasty were successful. In pigs, stent deployments were successful in both renal arteries. Autopsy revealed acceptable stent positioning. Guidewire visibility through applied markers was acceptable. Steerability, pushability, and device support were good in vitro and in vivo. CONCLUSIONS: The PEEK-based guide allows percutaneous MR-guided renal artery angioplasty and stenting with sufficient visibility, good steerability, pushability, and device support.


Assuntos
Angioplastia/métodos , Cetonas , Imagem por Ressonância Magnética Intervencionista/métodos , Imagens de Fantasmas , Polietilenoglicóis , Obstrução da Artéria Renal/cirurgia , Stents , Animais , Benzofenonas , Humanos , Polímeros , Suínos
14.
AJR Am J Roentgenol ; 192(3): 775-84, 2009 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-19234277

RESUMO

OBJECTIVE: The purpose of this study was to prospectively evaluate first-pass i.v. gadofosveset-enhanced MR angiography in patients with peripheral arterial occlusive disease for visualization of the pedal arteries and stenosis or occlusion of those arteries with intraarterial digital subtraction angiography as the reference standard. SUBJECTS AND METHODS: Twenty patients with peripheral arterial occlusive disease (nine women, 11 men; age-range 58-83 years) were prospectively enrolled. Gadofosveset first-pass contrast-enhanced MR angiography was performed with a 1.5-T system, a dedicated foot coil, and cuff compression to the calf. Arterial segments were assessed for degree of arterial stenosis, arterial visibility, diagnostic utility, and venous contamination. Detection of vessel stenosis or occlusion was evaluated in comparison with findings at digital subtraction angiography. The unpaired Student's t test was used to test arterial visibility with the two techniques. RESULTS: First-pass MR angiography with gadofosveset had good diagnostic utility in 83.9% of all segments and no venous contamination in 96.8% of all segments. There was no difference between the performance of intraarterial digital subtraction angiography and that of i.v. contrast-enhanced MR angiography in arterial visibility overall (p = 0.245) or in subgroup analysis of surgical arterial bypass targets (p = 0.202). The overall sensitivity, specificity, and accuracy of i.v. gadofosveset-enhanced MR angiography for characterization of clinically significant stenosis and occlusion were 91.4%, 96.1%, and 93.9%. In the subgroup analysis, the sensitivity, specificity, and accuracy were 85.5%, 96.5%, and 92.1%. CONCLUSION: Gadofosveset-enhanced MR angiography of the pedal arteries in patients with peripheral arterial occlusive disease has arterial visibility equal to that of digital subtraction angiography and facilitates depiction of clinically significant stenosis and occlusion.


Assuntos
Angiografia Digital/métodos , Arteriopatias Oclusivas/diagnóstico , Pé/irrigação sanguínea , Angiografia por Ressonância Magnética/métodos , Doenças Vasculares Periféricas/diagnóstico , Idoso , Idoso de 80 Anos ou mais , Arteriopatias Oclusivas/diagnóstico por imagem , Meios de Contraste , Feminino , Pé/diagnóstico por imagem , Humanos , Interpretação de Imagem Assistida por Computador , Iohexol/análogos & derivados , Masculino , Pessoa de Meia-Idade , Doenças Vasculares Periféricas/diagnóstico por imagem , Valor Preditivo dos Testes , Estudos Prospectivos , Sensibilidade e Especificidade
15.
J Digit Imaging ; 22(5): 473-82, 2009 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-17885790

RESUMO

BACKGROUND: Orthopedic trauma care relies on two-dimensional radiograms both before and during the operation. Understanding the three-dimensional nature of complex fractures on plain radiograms is challenging. Modern fluoroscopes can acquire three-dimensional volume datasets even during an operation, but the device limitations constrain the acquired volume to a cube of only 12-cm edge. However, viewing the surrounding intact structures is important to comprehend the fracture in its context. We suggest merging a fluoroscope's volume scan into a generic bone model to form a composite full-length 3D bone model. METHODS: Materials consisted of one cadaver bone and 20 three-dimensional surface models of human femora. Radiograms and computed tomography scans were taken before and after applying a controlled fracture to the bone. A 3D scan of the fracture was acquired using a mobile fluoroscope (Siemens Siremobil). The fracture was fitted into the generic bone models by rigid registration using a modified least-squares algorithm. Registration precision was determined and a clinical appraisal of the composite models obtained. RESULTS: Twenty composite bone models were generated. Average registration precision was 2.0 mm (range 1.6 to 2.6). Average processing time on a laptop computer was 35 s (range 20 to 55). Comparing synthesized radiograms with the actual radiograms of the fractured bone yielded clinically satisfactory results. CONCLUSION: A three-dimensional full-length representation of a fractured bone can reliably be synthesized from a short scan of the patient's fracture and a generic bone model. This patient-specific model can subsequently be used for teaching, surgical operation planning, and intraoperative visualization purposes.


Assuntos
Fêmur/diagnóstico por imagem , Fraturas Ósseas/diagnóstico por imagem , Imageamento Tridimensional/métodos , Modelos Anatômicos , Cadáver , Estudos de Viabilidade , Feminino , Humanos , Cuidados Pré-Operatórios/métodos , Reprodutibilidade dos Testes , Ensino/métodos , Tomografia Computadorizada por Raios X/métodos
16.
Cardiovasc Intervent Radiol ; 32(3): 514-21, 2009 May.
Artigo em Inglês | MEDLINE | ID: mdl-19115070

RESUMO

The purpose of this study was to demonstrate feasibility of percutaneous transluminal aortic stenting and cava filter placement under magnetic resonance imaging (MRI) guidance exclusively using a polyetheretherketone (PEEK)-based MRI-compatible guidewire. Percutaneous transluminal aortic stenting and cava filter placement were performed in 3 domestic swine. Procedures were performed under MRI-guidance in an open-bore 1.5-T scanner. The applied 0.035-inch guidewire has a PEEK core reinforced by fibres, floppy tip, hydrophilic coating, and paramagnetic markings for passive visualization. Through an 11F sheath, the guidewire was advanced into the abdominal (swine 1) or thoracic aorta (swine 2), and the stents were deployed. The guidewire was advanced into the inferior vena cava (swine 3), and the cava filter was deployed. Postmortem autopsy was performed. Procedural success, guidewire visibility, pushability, and stent support were qualitatively assessed by consensus. Procedure times were documented. Guidewire guidance into the abdominal and thoracic aortas and the inferior vena cava was successful. Stent deployments were successful in the abdominal (swine 1) and thoracic (swine 2) segments of the descending aorta. Cava filter positioning and deployment was successful. Autopsy documented good stent and filter positioning. Guidewire visibility through applied markers was rated acceptable for aortic stenting and good for venous filter placement. Steerability, pushability, and device support were good. The PEEK-based guidewire allows either percutaneous MRI-guided aortic stenting in the thoracic and abdominal segments of the descending aorta and filter placement in the inferior vena cava with acceptable to good device visibility and offers good steerability, pushability, and device support.


Assuntos
Aorta/cirurgia , Imagem por Ressonância Magnética Intervencionista/instrumentação , Imagem por Ressonância Magnética Intervencionista/métodos , Stents , Filtros de Veia Cava , Animais , Benzofenonas , Desenho de Equipamento , Estudos de Viabilidade , Cetonas , Polietilenoglicóis , Polímeros , Suínos
17.
Eur Radiol ; 19(2): 509-15, 2009 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-18795296

RESUMO

The purpose was to evaluate the effect of percutaneous transluminal angioplasty (PTA) of the superficial femoral artery (SFA) on the blood oxygenation level-dependent (BOLD) signal change in the calf musculature of patients with intermittent claudication. Ten patients (mean age, 63.4+/-11.6 years) with symptomatic peripheral arterial occlusive disease (PAOD) caused by SFA stenoses were investigated before and after PTA. Patients underwent BOLD-MRI 1 day before and 6 weeks after PTA. A T2*-weighted single-shot multi-echo echo-planar MR-imaging technique was applied. The BOLD measurements were acquired at mid-calf level during reactive hyperaemia at 1.5 T. This transient hyperperfusion of the muscle tissue was provoked by suprasystolic cuff compression. Key parameters describing the BOLD signal curve included maximum T2* (T2*(max)), time-to-peak to reach T2*(max) (TTP) and T2* end value (EV) after 600 s of hyperemia. Paired t-tests were applied for statistic comparison. Between baseline and post-PTA, T2*(max) increased from 11.1+/-3.6% to 12.3+/-3.8% (p=0.51), TTP decreased from 48.5+/-20.8 s to 35.3+/-11.6 s (p=0.11) and EV decreased from 6.1+/-6.4% to 5.0+/-4.2% (p=0.69). In conclusion, BOLD-MRI reveals changes of the key parameters T2*(max), TTP, and EV after successful PTA of the calf muscles during reactive hyperaemia.


Assuntos
Angioplastia com Balão/métodos , Aterosclerose/patologia , Imageamento por Ressonância Magnética/métodos , Músculos/patologia , Doenças Vasculares Periféricas/diagnóstico , Doenças Vasculares Periféricas/patologia , Idoso , Angiografia Digital/métodos , Aterosclerose/diagnóstico , Feminino , Humanos , Perna (Membro)/irrigação sanguínea , Masculino , Pessoa de Meia-Idade , Perfusão , Fatores de Risco , Fatores de Tempo
18.
Eur Radiol ; 18(4): 645-57, 2008 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-18071710

RESUMO

The magnetic resonance (MR) guidance of endovascular interventions is probably one of the greatest challenges of clinical MR research. MR angiography is not only an imaging tool for the vasculature but can also simultaneously depict high tissue contrast, including the differentiation of the vascular wall and perivascular tissues, as well as vascular function. Several hurdles had to be overcome to allow MR guidance for endovascular interventions. MR hardware and sequence design had to be developed to achieve acceptable patient access and to allow real-time or near real-time imaging. The development of interventional devices, both applicable and safe for MR imaging (MRI), was also mandatory. The subject of this review is to summarize the latest developments in real-time MRI hardware, MRI, visualization tools, interventional devices, endovascular tracking techniques, actual applications and safety issues.


Assuntos
Angiografia por Ressonância Magnética/métodos , Imagem por Ressonância Magnética Intervencionista/métodos , Doenças Vasculares/terapia , Angioplastia/métodos , Animais , Prótese Vascular , Meios de Contraste/administração & dosagem , Desenho de Equipamento , Humanos , Aumento da Imagem/métodos , Angiografia por Ressonância Magnética/instrumentação , Imagem por Ressonância Magnética Intervencionista/instrumentação , Stents
19.
Eur J Radiol ; 66(3): 519-25, 2008 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-17658713

RESUMO

PURPOSE: To evaluate the diagnostic value of contrast-enhanced intra-arterial 3D-MR-angiography (IA-MRA) of the infra-popliteal arteries in an open-bore magnet. Number, severity of arterial lesions, and artefacts were compared to routinely performed intra-arterial digital-subtraction angiography (IA-DSA) in patients suffering from symptomatic peripheral arterial occlusive disease (PAOD). MATERIAL AND METHODS: Fifteen patients admitted for PAOD underwent percutaneous transluminal angioplasty (PTA) by IA-DSA. After PTA, IA-MRA of the infra-popliteal station was performed on an open-bore 1.5T MR-scanner applying a low dose intra-arterial contrast-enhanced 3D-gradient-echo-MRA with gadopentate dimeglumine. The reading was performed by three blinded readers distinguishing moderate (< or =50%), significant stenoses (51-99%) and vessel occlusions. Imaging artefacts were recorded and binary classified as not disturbing or compromising the observation of the arterial tree. RESULTS: Overall IA-DSA revealed 36 moderate stenoses (< or =50%), 38 significant stenoses (51-99%), and 10 vessel occlusions. For the detection of significant stenoses and occlusions, the overall sensitivity, specificity, positive predictive value, negative predictive value and accuracy of IA-MRA were 96%, 83%, 88%, 94% and 90%. The only observed artefact was venous overlay in four stations. The readout was not hampered in any case. CONCLUSION: Intra-arterial contrast-enhanced 3D-gradient-echo-MRA on an open-bore MR-scanner offers an acceptable diagnostic accuracy in diagnosing peripheral arterial occlusive disease in the infra-popliteal region and correlates well with DSA.


Assuntos
Angiografia Digital , Arteriopatias Oclusivas/diagnóstico , Perna (Membro)/irrigação sanguínea , Angiografia por Ressonância Magnética/instrumentação , Doenças Vasculares Periféricas/diagnóstico , Artéria Poplítea , Idoso , Idoso de 80 Anos ou mais , Angioplastia com Balão , Arteriopatias Oclusivas/diagnóstico por imagem , Arteriopatias Oclusivas/terapia , Artefatos , Meios de Contraste , Feminino , Gadolínio DTPA , Humanos , Imageamento Tridimensional , Masculino , Pessoa de Meia-Idade , Doenças Vasculares Periféricas/diagnóstico por imagem , Doenças Vasculares Periféricas/terapia , Valor Preditivo dos Testes , Estudos Prospectivos , Sensibilidade e Especificidade , Resultado do Tratamento
20.
Radiology ; 239(3): 901-8, 2006 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-16641335

RESUMO

PURPOSE: To prospectively evaluate the accuracy of intraarterial magnetic resonance (MR) angiography in the depiction of significant stenoses and occlusions, with intraarterial digital subtraction angiography (DSA) serving as the reference standard. MATERIALS AND METHODS: Approval of the local ethics committee and informed consent were obtained. Twenty patients (11 men; nine women; age range, 48-86 years; mean age, 69.5 years+/-11.2 [standard deviation]) with symptomatic peripheral arterial occlusive disease (PAOD) were prospectively enrolled. After percutaneous transluminal angioplasty (PTA), intraarterial MR angiography was performed in the thigh and the calf with a 1.5-T MR imager in two consecutive runs. Intraarterial MR angiography was performed with a low-dose injection protocol (ie, two 20-mL injections of a 50-mmol gadolinium-based contrast agent). Moderate stenoses (luminal narrowing50%) or vessel occlusions; 95% confidence intervals (CIs) were calculated for sensitivity and specificity. RESULTS: Intraarterial DSA revealed 78 moderate stenoses, 57 significant stenoses, and 28 occlusions. Sensitivity, specificity, and accuracy of intraarterial MR angiography in the characterization of significant stenoses or occlusions were 92% (95% CI: 72%, 99%), 94% (95% CI: 82%, 98%), and 93%, respectively, in femoropopliteal arteries and 93% (95% CI: 83%, 98%), 71% (95% CI: 51%, 86%), and 86%, respectively, in infrapopliteal arteries. The main artifact observed with intraarterial MR angiography was venous contamination (12%). CONCLUSION: Intraarterial MR angiography is an accurate method used to depict significant stenoses and occlusions in lower extremity arteries with a low-dose injection protocol.


Assuntos
Angiografia Digital/métodos , Arteriopatias Oclusivas/diagnóstico , Angiografia por Ressonância Magnética/métodos , Doenças Vasculares Periféricas/diagnóstico , Idoso , Idoso de 80 Anos ou mais , Angioplastia com Balão , Arteriopatias Oclusivas/diagnóstico por imagem , Artefatos , Constrição Patológica/diagnóstico , Constrição Patológica/diagnóstico por imagem , Meios de Contraste , Feminino , Artéria Femoral/patologia , Gadolínio DTPA , Humanos , Processamento de Imagem Assistida por Computador/métodos , Perna (Membro)/irrigação sanguínea , Masculino , Pessoa de Meia-Idade , Doenças Vasculares Periféricas/diagnóstico por imagem , Artéria Poplítea/patologia , Valor Preditivo dos Testes , Estudos Prospectivos , Sensibilidade e Especificidade , Coxa da Perna/irrigação sanguínea
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...