Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
Minerva Cardioangiol ; 66(4): 361-367, 2018 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-29393600

RESUMO

BACKGROUND: Coronary perforations (CP) have been described as a rare but potentially fatal complication in percutaneous coronary interventions (PCI). Our aim is to compare temporal trends in frequency, management and outcomes of coronary perforations (CP). METHODS: All cases of CP recorded in our prospective institutional percutaneous coronary intervention (PCI) registry from 2003 to 2015 were included. Patients were divided in 2 groups according to the time frame in which the CP occurred: the early period (before 2009, when the chronic total occlusions and primary PCI programs started) and the current period. The primary endpoint was the composite of in-hospital serious adverse events, including final TIMI flow 0-1, cardiac tamponade, emergent cardiac surgery or death. RESULTS: Overall, 88 CP occurred in 17,566 procedures (0.50%). Of these, 17 (0.26%) occurred during the early period and 71 (0.64%) during the current period (P<0.001). CP management differed between groups, with less CP sealed by intracoronary devices in the early period than in the current one (23.5% vs. 47.9%, P=0.068). Moreover, patients with CP during the early period experienced more in-hospital serious adverse events (69% vs. 31% respectively, OR 3.18, 95% CI: 1.07-9.45, P=0.037). CONCLUSIONS: Expansion of indications and complexity of PCI in the current era may be associated with an increased frequency of CP. However, progress in technical and device management of CP have led to an improvement in the prognosis of this feared complication.


Assuntos
Traumatismos Cardíacos/epidemiologia , Traumatismos Cardíacos/terapia , Intervenção Coronária Percutânea/efeitos adversos , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/terapia , Idoso , Feminino , Traumatismos Cardíacos/etiologia , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/prevenção & controle , Estudos Prospectivos , Sistema de Registros , Resultado do Tratamento
2.
Circ Cardiovasc Interv ; 9(10)2016 10.
Artigo em Inglês | MEDLINE | ID: mdl-27702766

RESUMO

BACKGROUND: The main causes of late (>1 month) stent thrombosis (ST) are stent uncoverage, malapposition, and neoatherosclerosis. First-generation drug-eluting stents were associated with higher rate of late ST compared with bare-metal stents (BMS), especially in patients with ST-segment-elevation myocardial infarction. Second-generation everolimus-eluting stents (EES) have shown similar rate of late ST than BMS. The aims of the study are to compare the ratio of uncovered to total struts per cross-section ≥30% and other optical coherence tomographic findings associated with ST between EES and BMS in patients with ST-segment-elevation myocardial infarction at 5 years. METHODS AND RESULTS: One hundred and sixty-nine consecutive event-free patients of the randomized EXAMINATION study (A Clinical Evaluation of Everolimus Eluting Coronary Stents in the Treatment of Patients With ST-Segment Elevation Myocardial Infarction) were screened for optical coherence tomographic imaging at 5 years. Patients with target vessel-related events or life-threatening comorbidities were excluded. Finally, 64 patients (32 EES and 32 BMS) underwent optical coherence tomographic imaging. At 5 years, uncovered struts (4.1% versus 1.0%; P<0.01), length of uncoverage (3.4 versus 1.4 mm; P=0.02), and ratio of uncovered to total struts per cross-section ≥30% (35.5% versus 9.7%; P=0.02) were larger with EES than that with BMS. Malapposed struts (1.2% versus 0.3%; P=0.02) and malapposition length (1.3 versus 0.4 mm; P=0.06) were also larger with EES. Neoatherosclerotic plaques (16.1% versus 25.8%; P=0.35) and macrophage accumulations (19.4% versus 48.4%; P=0.02) were numerically more frequent with BMS. CONCLUSIONS: Despite substantial dropout of patients, the healing pattern in event-free ST-segment-elevation myocardial infarction patients differs between EES and BMS at 5 years. EES presented with larger amount of uncovered and malapposed struts and similar rate of neoatherosclerosis as compared with BMS. The clinical relevance of these findings warrants longer follow-up. CLINICAL TRIAL REGISTRATION: URL: http://www.clinicaltrials.gov. Unique identifier: NCT00828087.


Assuntos
Vasos Coronários/diagnóstico por imagem , Stents Farmacológicos , Metais , Intervenção Coronária Percutânea/instrumentação , Infarto do Miocárdio com Supradesnível do Segmento ST/diagnóstico por imagem , Infarto do Miocárdio com Supradesnível do Segmento ST/terapia , Stents , Tomografia de Coerência Óptica , Idoso , Angiografia Coronária , Trombose Coronária/diagnóstico por imagem , Trombose Coronária/etiologia , Intervalo Livre de Doença , Feminino , Humanos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Neointima , Pacientes Desistentes do Tratamento , Intervenção Coronária Percutânea/efeitos adversos , Placa Aterosclerótica , Valor Preditivo dos Testes , Desenho de Prótese , Fatores de Tempo , Resultado do Tratamento
3.
Am J Cardiol ; 117(6): 906-17, 2016 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-26874547

RESUMO

The potential of bioresorbable vascular scaffold (BVS) technology has been demonstrated in first-in-man studies with up to 5-year follow-up. This study sought to investigate the 1-year outcomes of the BVS, for the treatment of chronic total occlusions (CTOs), using various imaging techniques. Thirty-five true CTO lesions treated with BVS were included in this prospective study. Scaffolds were deployed after mandatory predilation and intravascular ultrasound analysis. Optical coherence tomography was performed after BVS implantation and at 10 to 12 months. Multislice computed tomography was performed at baseline and at 6 to 8 months. Mean patient age was 61 ± 10 years. The most frequent vessel treated was the right coronary artery (46%). Lesions were classified as intermediate (49%) or difficult/very difficult (26%) according to the Japanese CTO complexity score. Predilation was performed in 100% of lesions, using cutting balloons in 71% of these. The total scaffold length implanted per lesion was of 52 ± 23 mm. All scaffolds were delivered and deployed successfully. Postdilation was undertaken in 63%. By multislice computed tomography at 6 months, we observed 2 cases of asymptomatic scaffold restenosis, subsequently confirmed by angiography. At 12 months, no scaffold thrombosis or major adverse cardiac events were reported. The optical coherence tomography at follow-up showed that 94% of struts were well apposed and covered (5% of uncovered struts and 1% of nonapposed struts), and only 0.6% of struts were nonapposed and uncovered. In conclusion, 1-year results suggest that BVS for CTO is associated with excellent clinical and imaging outcomes. Accurate percutaneous coronary BVS technique might have enabled these promising results.


Assuntos
Doença da Artéria Coronariana/diagnóstico , Doença da Artéria Coronariana/terapia , Vasos Coronários/patologia , Stents Farmacológicos , Alicerces Teciduais , Idoso , Angiografia , Fármacos Cardiovasculares/farmacologia , Doença Crônica , Everolimo/farmacologia , Seguimentos , Humanos , Pessoa de Meia-Idade , Tomografia Computadorizada Multidetectores/métodos , Valor Preditivo dos Testes , Estudos Prospectivos , Sensibilidade e Especificidade , Espanha , Tomografia de Coerência Óptica/métodos , Resultado do Tratamento
4.
Vasc Health Risk Manag ; 11: 533-9, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26425097

RESUMO

Atheromatous and thrombotic embolization during percutaneous coronary revascularization is a feared complication that may cause impaired myocardial reperfusion even with a patent epicardial vessel. The MGuard stent is a cobalt chromium bare metal stent with a porous net attached to its outer surface that has been designed to prevent thrombus fragmentation and distal embolization during stent implantation. This review summarizes the available evidence supporting the use of the MGuard stent in different scenarios such as lesions with high thrombus burden, saphenous vein graft interventions, coronary perforations, or carotid lesions.


Assuntos
Doença da Artéria Coronariana/terapia , Trombose Coronária/terapia , Dispositivos de Proteção Embólica , Embolia/prevenção & controle , Infarto do Miocárdio/terapia , Intervenção Coronária Percutânea/instrumentação , Stents , Animais , Ligas de Cromo , Angiografia Coronária , Doença da Artéria Coronariana/complicações , Doença da Artéria Coronariana/diagnóstico , Trombose Coronária/complicações , Trombose Coronária/diagnóstico , Embolia/diagnóstico , Embolia/etiologia , Humanos , Infarto do Miocárdio/complicações , Infarto do Miocárdio/diagnóstico , Intervenção Coronária Percutânea/efeitos adversos , Desenho de Prótese , Fatores de Risco , Propriedades de Superfície , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...